Loading...
HomeMy WebLinkAbout1665 Ellington Road (4) TO THE BUHDING INSPECTOR of 1) APPLICATION FOR PLAN EXAMINATION AND TO" OF S4VTH WI1rDS4R,COI�iN. BUILDING PERMIT IMPORTANT — Applicant to complete all items in sections: 1, R, III, IV, and IX. O ZONING • AT (LOCATION) 7- 7- DISTRICT LOCATION (NO.) STREET) OF BETWEEN AND BUILDING (CROSS STREET) (CROSS STREET) LOT SUBDIVISION LOT BLOCK SIZE N II. TYPE AND COST OF BUILDING — All applicants complete Parts A — D ;0 A. TYPE OF IMPROVEMENT D. PROPOSED USE - For"Wrecking" most recent use m 1 ❑ New building Residential Nonresidential 2❑ Addition(It residential, enter number 12❑ One family 18 ❑ Amusement, recreational new housing units added, i/any, in Part D, 13) 13❑ Two or more family - Enter 19❑ Church, other religious n number of units- - - - - 20❑ Industrial 3 ❑ Alteration (See 2 above) � 14❑ Transient hotel, motel, 21 ❑ Parking garage 4❑ Repair, replacement or dormitory - Enter number 22 5 X Wrecking (If multifamily residential, of units ------- --i ❑ Service station, repair garage enter number of units in building in 15 ❑ Garage 23❑ Hospital, institutional Part D, 13) 16❑ Carport 24❑ Office, bank, professional 6❑ Moving (relocation) 17❑ Other - Specify 25❑ Public utility 7 ❑ Foundation only 26 ❑ School, library, other educational B. OWNERSHIP 27❑ Stores, mercantile 8 ❑ Private(individual, corporation, 28❑ Tanks, towers nonprofit institution, etc.) 29❑ Other - Specify 9 ❑ Public (Federal, State, or local government) C. COST (Omit cents) Nonresidential - Describe in detail proposed use of buildings,e.g., food processing plant, machine shop, laundry building at hospital,elementary 10. Cost of improvement................ S school, secondary school, college, parochial school, parking garage for, department store, rental office building, office building at industrial plant. To be installed but not included If use of existin building is being changed,enter proposed use. in the above cost �y a. Electrical...................... b. Plumbing .................... t D c. Heating, air conditioning......... for zz d. Other(elevator, etc.)............ 11. TOTAL COST OF IMPROVEMENT E III. SELECTED CHARACTERISTICS OF BUILDING — For new buildings and additions, complete Parts E — L; for wrecking, complete only Part J, for all others skip to IV. E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS 30❑Masonry(wall bearing) 40❑ Public or private company 48• Number of stories................ 31 ❑ Wood frame 41 ❑ Private(septic tank, etc.) 49• Total square feet of floor area, all floors, based on exterior 32❑ Structural steel dimensions .................... 33❑ Reinf rced concrete H. TYPE OF WATER SUPPLY 34❑ Other - Specify 42❑ Public or private company 50• Total land area, sq.ft. ........... 43 ❑ Private(well, cistern) K. NUMBER OF OFF-STREET PARKING SPACES 51. Enclosed ...................... F. PRINCIPAL TYPE OF HEATING FUEL I. TYPE OF MECHANICAL 35❑ Gas Will there be central air 52. Outdoors....................... 36❑ Oil c nditioning? L. RESIDENTIAL BUILDINGS ONLY 37❑ Electricity 44❑ Yes 45❑ No 53. Numb r f bedr ms.............. 38❑ Coal 39❑ Oth r- Specify Will then be an levat r? 54. Number of Full.......... 46❑ Y s 47❑ No bathr ma Partial....... NOTES and Data — (For department use) IV. IDENTIFICATION — To be completed by all applicants ame Mailing address%— Number, street, city, an State ZIP cod T I. No. I. Owner or aij.w c A. Lessee 2. Contractor 3. Architect or Engineer Th own r of this building and the undersigned agree to conform to all applicable laws oft is jurisdiction. Vb Signatur applicant Address Application ate / ,A 00 NOT WRITE BELO THIS LINE 1&6 A V. PLAN REVIEW RECORD — For office use Plan Review Date Plans Date Plans Plans R vi w Required Check Fee Started BY Approved By Notes BUILDING $ PLUMBING MECHANICAL ELECTRICAL $ OTHER VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS Permit or Approval Check Date Number B Permit or Approval I Check Date Number BY Obtained Y pp O um btained BOILER PLUMBING CURB OR SIDEWALK CUT ROOFING ELEVATOR SEWER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OIL BURNER WRECKING OTHER OTHER VII. VALIDATION Building 457 P rmit numb r - Bui Iding 74 Permit issued Mai i5 19 Bui Iding 5 e 00 Permit Fee $ 7 Approved by: r TITLE VIII. ZONING PLAN EXAMINERS NOTES DISTRICT USE FRONT YARD SIDE YARD SIDE YARD REAR YARD NOTES IX. SITE OR PLOT PLAN — For Applicant Use 77= IA , ; �..� +$ , ., yn Yam, �T"' g$w � �;� � .. s� .. {{ 4 t - _ _• � ` 't +- - .z-g-�r - 3- •-i r��r.�_,r x a-x w i� [ ��� y s"�r�g. f &. � .. t a; ��<��,. �.@ ��-�-��✓ o-� 5_ " s ^a„r.,-� , y � n�§k m ¢� � = o�r y. � , ,." ry• 1 $� � �s-„ e v 4�^ ( .-. � ,5 v „, y _ " j ._i_,. , _ a c ' t "' i -. tJ�P-`� fDo.,. - .-a_, „-a�a .a-��,�. w��p-o•w-g�sy...a ,..�.�..;,�. e tp.�,.-�.�.. .� ..,,,�.,� �,`,:�9 a �p- � P= �t � y_ _�" <+at�.sg� ¢ >� F g J�3 �d�a ,M �} 4 -� yr 4���.����.a;_���bY � + 8.° 9 �� ,. � � <s s ,-dam-. � ,�•-�� M$d � .. ,A �" "_ � -.. rb;s-.�' � -as» 1 ,y« •r��; "�" q�_ �% g �* �� ��t � �r rya ._` ,.., � _ � ? ! . €. ., ,,,_�� °�,....�#.�q-♦ .f,,1-4- ° � -d � g f y 1.,y .. - ;r-vq R-Y �,,, `-s 4 c � x t � , m , _ L 2 <� "'� }�aas� �-t��..rv +Y•,2t t ....}�...�� n��^qi+rt �l�Rl. 1.%�r€���--$.y vy�'.��-b--, -»�- -a.,m6-�. i� � <., ¢ _�._..x,-..--„�a,,.e,.,.d.� ..,,, Q n.�- d ......., g.,e$ saY 4f t }r# # s I`t _y.a..�.^.i_ A id- -»- } i TOWN OF SOUTH WINDSOR BUILDING PERMIT r � Date May 15 1974 Fee Paid $. $!©0 Est. Value $. . . . . . Permit N0 8457 on the side of Ellington Road Street Street No. 1665 Owner Alma Lawton Applicant Edward Kuehn CERTIFICATE OF OCCUPANCY ISSUED: Date No. Fee Paid $ CLASSIFICATION Demolish rear building Mao #77 Blook #2 BUILDING PERMIT 8457 OFFICE OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. South Windsor, Conn. May 15 19 74 94is to to Terttf1j, That Nward Khekm is hereby granted permission to Demolish rear building Map #77 Block #2 at estimated value of $ on the side of 1665 Ellington Road Street on land owned by Alma Lawton Said Work to be as described in Application No. 8757 and to conform to specifications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH WINDSOR. Iss a Mety 15 19 74 ;moo Ui1499 Inspector. Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: "When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costs and damages which it shall sustain, or be compelled to reason therefor." INSPEMION REPORT Permit # Job /66 1 Footing 2 Foundation 3 Framing 4 Wiring 5 Plumbing 6 Heating 7 Lathing a c.o. S ,���# ;� 3,3 APPLICATION FOR BUILDING PERMIT 1665 ELLINGTON ROAD Plumbing# °,5& Date: -25-99 HVAC # 10 g'i!D X 25919 Sprinkler# I No. FINAL APPROVALS Estimated Cost $ 4"/41f 006 Building Teo X W `1 D / COMPLETE REDS OXED AREAS Permit Fee $ t 7bk Engineering TYPE'OR PRINT ONLY Occupancy Fee $ S Affidavit SIGN ON REVERSE SIDE Appr.for CO. i t 41 Total Fee $ -q 73 TO BUILDING D ARTMENT, TOWN OF SOUTH WINDSOR,CT (Additional Cost) $ Z Th undersigned hereby applies to do work according to the following specifications: Job Location 1665 Ellington Rd. Lot No. Side of Street South Zone Applicant W.J. Mountford, Inc. Tel.# (860) 291-9448 Address 205 Nutmeg Road South, South Windsor Zip 06074 Lic. # nngnn574 Own r Tn1 1 and Bank Address Route 30 Vernon. CT Architect Moser Pilon Nelson/ Arch.Address 30 Jordan Lane, Wethersfield, CT 06109 565" `f Sq. Ft. New Area: 1st FI. 5 1020 2nd FI. - 3rd FI. - Total New Area 5,020 #Rooms See Plans # Lavatories #Bathrooms #Garages None Purpos of this permit: Rini 1 d i ng uermi t f or construction of new wood framed gingle atory building for Tolland Bank, Building exterior is brick veneer and the roof is asphal shingles. "see plans" 502-0 �W. ft-_ City Water Well ❑ Septic System ❑ Sewer a 87,E Use Group Construction Type 6 6 Area / Basement Garage Approved by Q\1TQ- _ Date 2t Revisal 6/95 _I I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked, and agree that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zo in which this building and its use is allowed. Signed I hereby apply for a Certificate of Occupancy forMworkscribed in this application for the permit Signed -- DO IT WRITE BELOW THIS LINE -- INSPECTION COMMENTS • 1 092. Location of job AFFIDAVIT Additional Fee . . .. .�.. . . . .. ..00. .. .. . . State of Connecticut County of Hartford ss. South Windsor l Scott P. Mountford, President W J Mountford, Owner .... . . ... . . . . ... . . ...of . '.. ..... . .. . . . .. . . .. . . a nt for building erected under ontractor Permit No . . . . . ...2.5.91.9 .... .. . .. . ... issued by the Dep't of Building of the'lbwn of South Windsor being duly sworn,make oath and say that the actual cost of the completed work authorized under said pe s. . . . . . $5 9 ,18 2. 0 . . . .. . . . . . . . .. .. .. . ... . . . .. .. Signed .. . .. .... ....... . ... 29th c t P. Moun fo President Subscribed and sworn to before me this . .. . . ... . . . .... . ..... . . .day of .. .. . ..Or-t ob a . . .. .. . . . . .. . . A.D.19 99. . Estimate Cost:$ 500,500.00 Difference: $ 909682.00 oJ- ilubl2iF Leola R. Lamothe Commission Expires: October 31, 2001 Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- 99-25919-B 414,000 B01 FOOTING 04/09/99 JFF A WEST WALL REBARS IN PLACE WITH SUPER B01 FOOTING 04/12/99 JFF A SOUTH AN EAST FOOTING CLARENCE WELTI REVISED NE FOOTING WATER TO SUBMIT REPOETS B01 FOOTING 04/19/99 DCJ A FRONT WALL ADJACENT TO HS. B04 INSULATION 04/29/99 JFF A PERIMETER SLAB INSUL WITH CONTRACTOR E02 UNDERGROUND 04/29/99 JFF A P02 UNDERGROUND 04/29/99 JFF A WITH CONTRACTOR B03 FRAMING (ROUGH) 05/04/99 DCJ D POURING SLAB NOT READY B03 FRAMING (ROUGH) 06/22/99 DCJ A B04 INSULATION 06/24/99 JFF A CEILING ONLY E03 ROUGH 07/02/99 RAN A P03 ROUGH 07/02/99 RAN A B04 INSULATION 07/08/99 JFF A WITH SUPER B04 INSULATION 07/08/99 JFF A WALLS R19 PO4 GAS TEST 07/08/99 JFF A WITH SUPER E01 SERVICE 07/12/99 DCJ A RELEASED TO N.U. B03 FRAMING (ROUGH) 05/05/99 JRC A B03 FRAMING (ROUGH) 08/23/99 DCJ D ABOVE CEILING, SEAL PENETRATIONS Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- B10 FINAL 08/27/99 DCJ A 99-10540-H 38,500 99-10364-P 6,000 99-16233-E 42,000 E03 ROUGH 07/02/99 RAN A BANK AREA AND TWO TENANT SPACES BELOW CEILING P03 ROUGH 07/02/99 RAN A BATHROOM GROUP AND KITCHEN AREA SINK AND TEST -r SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTIICUT 1665 ELLINGTON ROAD LOT_# Reviewed By J• 1JA eering) MOUNTFORD W J Date Reviewed a pp enied 205 NUTMEG ROAD SOUTH,SOUTH WINDSOR,CT Reviewed B 1A rming) BP_#_25919_ Ph_#_(203)291-9448 Date Reviewe / flypprov /Denied Date Submitted 10/29/99 ***** FOR C 0 **** -1I5 ' As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1. Approved building permit plan CSj-r5 VL' 7 2. Finish grading per approved building permit plan 3. Site work; i.e. trees, shrubs, dumpsters, required parking _ 4. Utility location; a. sanitary sewer/septic system b. foundation drain C. electrical & telephone d. water e. other CG,gy� _ 5. Sewer connection charge paid -7(-1't`91 6. Appropriate certification 7. Bonding 8. Planning & Zoning/ Inland Wetlands Considerations Sewer Permit No. _10 ZA Pavement Excavation No. COMMENTS: �rlf�ID A�r'�� ��pN Sip ss& Sv6MiTiMD F.I.iMAWTrNCs ��. UM& ,�N tn1fr.�T srv��c� ,avorc> coNwsioa , �1 ,? Ella 1Y c,Qrr.�r� �-ME � OCT 2 9 199 - E wr IJ�1 a y B� vv� ON t0(L!, 0 ,✓ SOUTH WINDSOR i �fi'�T'� W, �mtlfw� 1�N�k (�l-..C� r G, s)r* r.�C. s.�c Y "D DEPT. O cNG 10� ()E.SgA=>4 .619v—3319 10/29/99 10:55 10860 872 8655 TOLLAND BANK Q001 :Iw�e +ast Tolland Bark . October 29, 1999 Town of South Windsor 1540 Sullivan Ave South Windsor CT 06074 Attu:Joe Perna Dear:Joe Thank you for returning my phone call so promptly,Per our cunversspon Tolland Bank will work with the town of South Windsor regarding the sidewalk issues. The sidewalk ememe=are currently being prepared and will be delivered to you no Ida than November 12, 1999, I would like to thank you for the time you spent today working with me on these imm. 3lacerely, Todd Laaard Facilities Manager Mailing Address:POR Of'ltce Box i 56 a Tolland. Connecticut 06084 • (8601875.2500 DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT PST# Application is hereby: TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bid 't# PR 1540 SULLIVAN AVENUE 46 F� 644-2511 ext.230 Date Building Inspector Application must be printed or typed Location of job arosTxv Street No. Street Lot No. FEE SCHEDULE Floor Apt.No. $0 - $1,000 - $12.00 Over $1,000 $12.00 per$1,000 OWNER -�� (30/L,� or any fraction thereof ADDRESS 7— ?0 Ile X I)o e OWNERS PHONE# APPL1CANT_Ae4/? p O W N Se ADDRESS J 6�1j 611N ESTMATED COST$ C IS THIS A CONTRACT COST? YES NO FFE ENCLOSED $ LI OR-CO TYPE OF JOB: X Original on Alteration/Addition/Repair Revised 11/95 k APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A RESIDENTIAL BUILDING PERMIT APPLICATION YES / NO BUSINESS ASSEMBLY CURRENT USE AND OCCUPANCY MERCANTILE EDUCATIONAL FUTURE USE AND OCCUPANCY fl4Cf�y ,•�i INSTITUTIONAL FACTORY STORAGE ENGINEER'S NAME PHONE GARAGE MIXED USE ADDRESS CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF MAIN FEEDERS AND RATING OF WIRE USED NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED?YES/NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPERATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK -Tc,-j P—la,01,- 5, THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH WORK K-4,_e_,0 NAME STATE LICENSE NO. TYPE SIGNATURE OF APPLICKNT PHONE NO. 6,e")-3 C 5 6 3 DATE ��' INSPECTOR- LOCATION C- J DATE i Z� TIME ` l _ INSPECTION: CODE: RESULT(D/A) : BUILDING: ELECTRICAL: PLUMBING: HVAC: OTHER: . DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT t �P Application is hereby: TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Permit# �J4 1540 SULLIVAN AVENUE 4 1/ � 644-2511 ext. 230 /Date Building Inspector Application must be printed or typed Location of job I IoloS GL1J&WMN �D . Street No. Street Lot No. FEE SCHEDULE Floor Apt.No. $0 - $1,000 - $12.00 Over $1,000 - $12.00 per$1,000 OWNER TO L b.Nb e�b`m� or any fraction thereof ADDRESS 74- 30 V E121-J0N GT. 060(a(D OWNERS PHONE# APPLICANT 64 2.- VAI I Ey 1 bs 0 S� ADDRESS ESTIMATED COST$ C = IS THIS A CONTRACT COST? NO ICJ FEE ENCLOSED $ 72? f TYPE OF JOB: OR-Co Original Installation Alteration/Addition/Repair Revised 10/96 APPLICATION FOR PLUMBING PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION YES / NO RESIDENTIAL y_BUSINESS CURRENT USE AND OCCUPANCY ASSEMBLY MERCANTILE FUTURE USE AND OCCUPANCY 5&KW- EDUCATIONAL INSTITUTION FACTORY ENGINEER'S NAME 1 S 4;55 OC4 dTEG PHO _7- Z3 GARAGEE ADDRESS 161 PO4M V-D- MIXED USE CITY N"1 Q 6--Z STATE ZIP 0(oil (Other please specify) TYPE OF INSTALLATION SIZE OF MAIN DRAIN 4` NO. OF TOILETS 1 STYLE NO. OF URINALS STYLE NO. OF BATHTUBS — NO. OF SHOWERS - NO. OF LAVATORIES�1 _ NO. OF CONDUCTORS - SIZE NO. OF STACKS SIZE AREA OF ROOF NO. OF CATCH BASINS NO. OF FLOOR DRAINS NO. OF OTHER FIXTURES KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW YES O SIZE OF WINDOW IF NONE C.F.M. OF VENTILATOR T10•PL&M SIZE OF DUCTS SEWS OR SEPTIC TANK SIZE OF WATER MAIN 1 SIZE OF WATER PIPING&RISER l WATER HEATER TYPE QLr4Ta4 L MANUFACTURE O.,d.Sfn IT W TANKS SAFETY DEVICES TEMPERATURE CAPACITY 20 Gw, RELIEF VALVE TEST PRESSURE WORKING PRESSURE PRESSURE RELIEF VALVE TYPE MANUFACTURER DESCRIPTION OF WORK PLB&- per- PLws. # SPAS THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING C S PERFORMANCE OF SUCH WORK. NAME STATE LICENSE NO. TYPE SIGN ANT PHONE NO. DATE �`� FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: 09 (N0. d I K ) TOWN OF SOUTH WINDSOR EST.COST: � S , r7, BLDG. PERMIT NO. 1540 SULLIVAN AVENUE FEE ^ SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 $ 0 - $19000 - ,$•1$:0� / $1000 or fraction�d,2. LOCATION OF BUILDING G 6� �4�/j���1��1/ thereof - S�,zve � e 110 00�ZIA A L- ON-ER. ADDRESS TOWN PHONE NO. ,� �� �/ - S C/ H VAC CONTRACTOR ADDRESS TOW PHONE NO. TYPE OF SYSTEM: HEATING TYPE OF BUILDING: RESIDENTIAL A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS N-PUT ELECTRIC KW WOOD OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS (BTUH) _(HEAT LOSS SHEET MUST CCOMPANY APP ICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.) : 60 GROSS HEATING CA ACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN (BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.) : -5#sr- An� �ftoil ` TONNAGE COOLING CAPACITY (BTUH) IF VENTILATIOP: DESC�i E LL AIR-HANDLING EQUIPMEN (INCLUDING KITCHEN EXHAUSE EQUIPMENT) : �,:3- ) _77, Ae_?� r1c" TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) (PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: VAI 7i6y 1),o�� 7 jq-95P 01 . STATE LICENSE - NAME & TYPE # DATE SIGNATURE Or APPLIC NT 2� 5 APPROVED iTl� BD 4A 11/88 I = B= R CALCULATION SHEET 1503 (Modern Method) Copyright 1977 by The Hydronics Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL.A COL.B COL.C COL.D COL.E COL.F COL.G ROOM a:O H L W H L W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS, FT ~ _ O BTUH per F t of 3 LENGTH EXPOSED WALLS, FT Q Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA LL BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION ROOM LIN. FT.OF 1 F (Table 9, Line 3 x H) TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED (Bottom of table used for Line 5) 7 CEILING CONSTRUCTION C (Table 9 L x W) - ----- - --- D— y FLOOR CONSTRUCTIONI (Table 9, L x W or Lin Ft) E 9 COLD PARTITION CONSTRUCTION F (Table 9, L x H) 1U c 1 Wall(With Openings) - -- -- C H 0 2 Walls(With Openings) D X _ — _ e J I 3 Walls(With Openings) or Ent Hall f. 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE K COL A COL B COL.H COL. 1 COL J COL K COL.L TOTALSTUH TOTAL -------------- ---------- OF BUILDING RADIATION 1 ROOM - - ¢ _ _ --_ AT SELECTED O OH L W JH L W H L W H I L I W H L W DESIGN TEMP.* DIFFERENCE 2 ROOM DIMENSIONS. FT ~ 3 LENGTH EXPOSED WALLS, FT Q 4 WINDOW AND OUTSIDE DOOR AREA LL — BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION *INCREASE BATHROOM (Table 9, Line 3 x H) TOTAL 20% 6 TYPE OF GLASS ---------- -- ------- ---- - ---- --- -------------- -- ----- -- - — (Bottom of table used for Line 51 -- -------------- ------------ - --- --------- 7 CEILING CONSTRUCTION 1 UN RETE FLOOR ON GROUND OR FILL AT (Table 9, L x W) GRADE LEVEL,USE LINEAR g FLOOR CONSTRUCTIONI FEET OF EXPOSED EDGE (Table 9, L x W or Lin Ft► 9 COLD PARTITION CONSTRUCTION (Table 9, L x H) 10 c 1 Well(With Openings) -- ---- 0 - - --- o C 4 2 Walls(With Openings) z X __— _ eJ 3 Walls(With Openings)or Ent Hall 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE This form is available from The Hydronlcs Institute,35 Russo Place,Berkeley Heights,N J 07922 FORM 1503 Client: Tolland Bank, Vernon, Connecticut R+ ' S T L Project: Tolland Bank Plaza, S. Windsor, CT Contractor: W. J. Mountford SPECIAL TESTING LABORATORIES,INC. Inspector: E. Zorca PO Box 200 Bethel,Connecticut 06801 Phone(203)743 7291 Fax(203)7912451 Date: April 27, 1999 Field Density (Soils) CERTIFICATE OF TEST MATERIAL: Borrow LOCATIONS: All tests taken along the perimeter of the building on compacted backfill material, interior sidt of the wall. Test Nos. 14 taken along South Wall; Test Nos. 5-8 taken along West Wall; Tes7 Nos. 9-12 taken along East Wall and Test Nos. 13-16 taken along North Wall. SPECIFIED COMPACTION REQ NTS: 95 % - All tests were accepted. Inspected the compaction of fill material. In place density tests taken, results noted below. INSITU DENSITY TESTS ASTM D-1556_ D-2167_ D-2922 COMPACTION INSITU DRY TEST APPROXIMATE LBSICUBIC OPTIMUM DENSITY LBSI INSITU COMPACTION NO. ELEVATION FOOT MOISTURE E% CUBIC FOOT MQSTUR F % % 1 85'6" 137.1 7.5 127.6 5.5 93.1 2 Retest of No. 1 131.0 6.0 95.6 3 86'2" 132.0 6.2 96.3 4 86'10" 130.8 5.9 95.4 5 85'6" 127.2 5.2 92.8 6 Retest of No.5 130.9 5.9 95.5 7 86'2" 131.8 6.3 96.1 8 86'10" 131.2 5.7 95.7 9 85' 126.0 5.0 91.9 10 Retest of No. 10 131.6 5.8 96.0 11 86' 131.3 6.1 95.8 12 85'8" 130.7 5.6 95.3 13 84' 126.8 7.3 92.5 14 Retest of No. 13 131.5 6.7 95.9 15 84'6" 132.2 6.4 96.4 16 85, 130.5 6.0 95.2 REMARKS: Approximate elevations provided by contractor. MATERIAL TESTED: Similar to Proctor for Sample No. 1, 1PROC DATED: 04/16/99 ALL DATA NOT REPEATED IS TYPICAL REPORTED TO: Client; South Windsor Building Official; W.J. Mountford; Moser, Pilson, Nelson; Girard & Co. Respectfully submitted, .. f SPEC ING LABORATORIES, INC. �►������0 NN CT a • /►jam' .• Eo 04*090 •• sroHa�.��'� YI Richard Speciale - Director J0 so"l man, P.E. Vice President Vice President THE RESULTS SHOWN ON THIS REPORT RELATE ONLY TO THE SAMPLES TESTED. THIS REPORT SHALL NOT BE USED TO CLAIM PRODUCT ENDORSEMENT BY NVLAP OR ANY OTHER GOVERNMENT AGENCY. THE FOREGOING INFORMATION IS THE PROPERTY OF CLIENTS. REPRODUCTION OR PUBLICATION ONLY WITH OUR EXPRESS PERMISSION. SPECIAL TESTING LABORATORIES,INC.EXCLUDES ALL LIABILITY FOR WORK PERFORMED BY OTHERS. AREA OFFICES IN DANBURY-HARTFORD-NEW HAVEN-NEW LONDON omr VISIT OUR WEB SITE AT www.uconect.net/-stl SPECIAL TESTING LABORATORIES, INC. Page: 2 of 2 CLIENT: Tolland Bank, Vernon, Connecticut PROJECT: Tolland Bank Plaza, S. Windsor, CT SAMPLE: 1, 1 PROC Sieve size used to separate oversize particles = 3/4" Percent by weight of oversize = 30.0 % Estimated Bulk Specific Gravity - GM = 2.65 Dry Unit Weight and Water Content Finer Fraction = 127.8 @ 9.2 % 3/4" Correction Dry Unit Weight and Water Content Total Sample = 137.1 @ 7.5 % Optimum Water Content: 7.5 % Max. Unit Weight, Dry, (lbs./cu. ft.): 137.1 Remarks: Borrow Material - Brown/Red GRAVEL & Sand, trace Silt - Source: McKnight Pit Date: April 15, 1999 By: N. Furtado LABORATORY SOIL CONTROL CURVE 139 t 3�! Y- V 135 flit-1. ILL 1111-.11J1.1 LIUMMU11 I IILLLW t .1m. Engineering •Steel• Water • Concrete • Chemical Analysis •Soils•Test Borings• Core Drilling• Asphalt • Asbestos Client: Tolland Bank, Vernon, Connecticut S T L Project: Tolland Bank Plaza, S. Windsor, CT Contractor: W. J. Mountford SPECIAL TESTING LABORATORIES,INC. Lab Technician: N. Furtado Page: 1 of 2 PO Box 200 Bethel,Connecticut 06801 Phone(203)743 7281 Fax(203)791 2451 Date: April 15, 1999 Report No. 1 PROC CERTIFICATE OF TEST AND ANALYSIS MATERIAL: Borrow - Brown/Red GRAVEL & Sand, trace Silt RECEIVED: April 12, 1999 - Picked up by P. Blanchard (STL) MARKED: Sample ##1 (99S0019) - Proposed Structural Fill - Source: McKnight Pit TEST METHOD: Maximum-Unit Weight, Dry (lbs./cu.ft.) ASTM D1557 METHOD C, 3/4" Correction ASTM D4718 - Material Analysis ASTM C 136 Examined with the following results: PROJECT SPECIFICATIONS SIEVE SIZE PERCENT PASSING Structural Fill-Common Fill 3" 100.0 100 - 2" 87.4 - 100 1 112" 84.6 3/4" 70.0 - - 1/4" 49.7 - - #4 45.8 30-70 - #10 35.2 - #20 22.4 10-50 - #►40 12.9 5-30 0-80 #100 4.6 0-10 - #200 2.8 - 0-50 REPORTED TO: Client; S. Windsor Building Official; W.J. Mountford; Moser, Pilson, Nelson; Girard & Co. Respectfully submitted, SPECIAL TESTING LABORATORIES INC. °' �!� !.° .tea•,• '��,l�•, 4 LIE � {_� j:. ��, ,- �� � ,: cam,. �`•ti°� Richard Speciale - Director John Hardman, P.E. Vice President Vice President THE RESULTS SHOWN ON THIS REPORT RELATE ONLY TO THE SAMPLES TESTED. THIS REPORT SHALL NOT BE USED TO CLAIM PRODUCT ENDORSEMENT BY NVLAP OR ANY OTHER GOVERNMENT AGENCY. THE FOREGOING INFORMATION IS THE PROPERTY OF CLIENTS. REPRODUCTION OR PUBLICATION ONLY WITH OUR EXPRESS PERMISSION. SPECIAL TESTING LABORATORIES,INC.EXCLUDES ALL LIABILITY FOR WORK PERFORMED BY OTHERS. AREA OFFICES IN DANBURY-HARTFORD-NEW HAVEN-NEW LONDON omr VISIT OUR WEB SITE AT www.uconect.net/-stl r Client: Tolland Bank, Vernon, Connecticut S T L Project: Tolland Bank Plaza, SO Windsor, CT Contractor: W. J. Mountford sl�ctAr,TBsrn�a r.ABORnTo�s,INC. Contractor: E. Zorca Po Boa 200 Bethel,Connecticut 06801 Phone(203)743 7281 Fax(203)7912451 Date: April 9, 1999 Concrete Report CONCRETE INSPECTION WEATHER: RAIN FINE AGGREGATE: AIR TEMPERATURE:50•F t COARSE AGGREGATE: CEMENT BRAND: CONCRETE SUPPLIER: BUILDER'S CONCRETE, INC. CYLINDER PICK UP DATE:4/12/99 CLASS 3000 PSI PSI PLANT FIELD CUBIC YD. DESIGN BATCH DESIGN BATCH CEMENT PREVIOUS YDS. 00.0 INSPECTED 13.0 FINE ;3..0 0 COARSSEE TOTAL TO DATE AGO.3/4 START COARSE AGO. 1/2 WATER GALS. FINISH 12 5 ADMIX.O2. TOTAL HOURS SUP.P(OZ.) AGGREGATE GRADING %PASSING 100 50 30 16 8 4 3/8 1/2 3/4 1 1 1/2 FM %MOIST. FINE AGG. COARSE AGG.3/4 COARSE AGG.1/2 CONCRETE FIELD INSPECTION AND TEST RESULTS TRUCK TICKET TIME TIME OF TIME OF FIELD AIR SLUMP, AIR DENSITY CONC.TEMP NO. NO. BATCHED DISCHARGE TEST SET ale CONTENT% INCHES TEMP. LBS.CU FT. •/F 21 082169 1439 1510 1520 1 A-D 5.2 4.25 50 140.0 65 LOCATIONS:COMPLETE FOOTING AT WEST WALL, 50' FOOTING AT SOUTH WALL. REMARKS:MIX 53034 HD. aaaaaaaa#a##aaaaaaai##a##aaaaaaaaaa#a#•iaaai•••sa•aaaaaiiaaaaa#aisasiaaa#a#i#iaa#aa##aai#ia###iai#i##a#i#i#i#ilia LAB CONCRETE TEST RESULTS CYLINDER TESTED TOTAL BREAK CYLINDER TESTED TOTAL BREAK NO. CONDITION AT LOAD PSI TYPE NO. CONDITION AT LOAD PSI TYPE 99C1389 GOOD 7 DAYS 79500 2810 D 99C1390 99C1391 99C1392 REFERENCE ASTM C39,C143, C173, C31 TYPE A:CONE TYPE B:CONE&SPLIT TYPE C:CONE&SHEAR TYPE D:SHEAR TYPE E:COLUMNAR DIAMETER = 8" CROSS SECTIONAL AREA = 28.27 REPORTED TO: CLIENT• UILDING OFFICIAL;W.J.MOUNTFORD;MOSER, P �ml •� �&CO. CT .• :� 1 . + THE RESULTS SHOWN ON THIS REPORT RELATE ONLY TO THE 3;f� ��BTED. • THE FOREOOIN FORMATION IS THE PROPERTY OF CLIENTS•REPRODUCTION OR PVUBLICATION ONLYEWITH ER EXPRESS PERMISSION. SPECIAL TESTING LABORATORIES,INC. EXCLUDES ALL LIABILITY FOR WORK PERFORMED BY OTHERS. A Itd AREA OFFICES IN DANBURY-HARTFORD-NEW HAVEN-NEW LONDON VISIT OUR WEB 81TE AT www.ucoMct.nmtrotl Client: Tolland Bank, Vernon, Connecticut S T L , Project: Tolland Bank Plaza, S. Windsor, CT Contractor: W. J. Mountford SPECIAL TESTING LABORATORIES,INC. Inspector: E. ZOrca PO Box 200 Bethel,Connecticut 06801 Phon (203)743 7281 Fax(203)7912451 Date: April 9, 1999 Concrete Report CONCRETE INSPECTION WEATHER: RAIN AIR TEMPERATURE: 506F t FINE AGGREGATE: COARSE AGGREGATE: CEMENT BRAND: CONCRETE SUPPLIER: BUILDER'S CONCRETE, INC. CYLINDER PICK UP DATE:4/12/99 CLASS 3000 PSI PSI PLANT FIELD CUBIC YD. DESIGN BATCH DESIGN BATCH PREVIOUS YDS. 00.0 CEMENT INSPECTED 13.0 FINE AGG.COARSE AGG.3/4 TOTAL TO DATE 13.0 0 COARSE AGG. 1/2 FINISH 1 START 140400 WATER GALS. TOTAL HOURS ADMIX.OZ. 2.5 SUP.P IOZ.I AGGREGATE GRADING %PASSING 100 50 30 16 B 4 3/8 1/2 3/4 1 1 1/2 FM %MOIST. FINE AGG. COARSE AGG.3/4 COARSE AGG.1/2 CONCRETE FIELD INSPECTION AND TEST RESULTS TRUCK TICKET TIME TIME OF TIME OF FIELD AIR SLUMP, AIR DENSITY CONC.TEMP NO. NO. BATCHED DISCHARGE TEST SET# CONTENT% INCHES TEMP. LBS. CU FT. •/F 21 082169 1439 1510 1520 1 A-D 5.2 4.25 50 140.0 65 LOCATIONS:COMPLETE FOOTING AT WEST WALL, 50' FOOTING AT SOUTH WALL. REMARKS:MIX#3034 HD. LAB CONCRETE TEST RESULTS CYLINDER TESTED TOTAL BREAK CYLINDER TESTED TOTAL BREAK NO. CONDITION AT LOAD PSI TYPE NO. CONDITION AT LOAD PSI TYPE 99C1389 GOOD 7 DAYS 79500 2810 D 99C1390 28 DAYS 121000 4280 D 99C1391 28 DAYS 124500 4400 D 99C1392 28 DAYS 118500 4190 D REFERENCE ASTM C39, C143, C173,C31 TYPE A:CONE TYPE B:CONE&SPLIT TYPE C:CONE&SHEAR TYPE D:SHEAR TYPE E:COLUMNAR DIAMETER = 6" CROSS SECTIONAL AREA = 28.27 ,tIQitE lif fso .•'µµArita••."ri' a REPORTED TO: CLIENT;S.WIN LDING OFFIC ;W. �JNTFORD; MOSER, P SSb •1NELSON•61Fi- k-,CO. C� t! i pb1�i 21 y� I ••o. •�"j i \ I A� c+-s ^` •• .•'' �''` fib THE RESULTS SHOWN ON THIS REPORT REL-ATE ONLY TO THE SAMPLES TESTED. �. THIS REPORT SHALL NOT BE USED TO CLAIM PRODUCT ENDORSEMENT BY NVLAP OR ANY OTHER GOVERNMENT AGENCY. THE FOREGOING INFORMATION IS THE PROPERTY OF CLIENTS. REPRODUCTION OR PUBLICATION ONLY WITH OUR EXPRESS PERMISSION. SPECIAL TESTING LABORATORIES,INC. EXCLUDES ALL LIABILITY FOR WORK PERFORMED BY OTHERS. AREA OFFICES IN DANBURY-HARTFORD-NEW HAVEN-NEW LONDON If VISIT OUR WEB SITE AT www.uconect.neH"etl tr 1 ' Client: Tolland Bank, Vernon, Connecticut S T Project: Tolland Bank Plaza, SR Windsor, CT Contractor: W. J. Mountford SPECIAL TESTING LABORATORIES,INC. Inspector: E. ZOrca PO Box 200 Bethel,Connecticut 06801 Phone(203)743 7281 Fax(203)7912451 Date: April 19, 1999 Concrete Report CONCRETE INSPECTION WEATHER: CLEAR FINE AGGREGATE: AIR TEMPERATURE:50-F t COARSE AGGREGATE: CEMENT BRAND: CONCRETE SUPPLIER: BUILDER'S CONCRETE, INC. CYLINDER PICK UP DATE:4/22/99 CLASS 3000 PSI PSI PLANT FIELD CUBIC YD. DESIGN BATCH DESIGN BATCH PREVIOUS YDS. 13.0 CEMENT INSPECTED - 8.5 FINE AGG, TOTAL TO DATE COARSE AGO.3/4 21.5 COARSE AGO. 1/2 START r 0700 WATER GALS. FINISH 1100 ADMIX.OZ. TOTAL HOURS 4.0 SUP.P I Z.► AGGREGATE GRADING %PASSING 100 50 30 16 8 4 3/8 1/2 3/4 1 1 1/2 FM %MOIST. FINE AGG. COARSE AGG.3/4 COARSE AGG.1/2 wawwrarwwrwrwrwwrrwrwrrrrarwr+rawawarr_wasaraaw�rarwrRaraawawawrwrwaararRrrwrrwawrRawrawwwrrrararrarRwawwRwaaaaraw CONCRETE FIELD INSPECTION AND TEST RESULTS TRUCK TICKET TIME TIME OF TIME OF FIELD AIR SLUMP, AIR DENSITY CONC.TEMP NO. NO. BATCHED DISCHARGE TEST SET# CONTENT% INCHES TEMP. LBS.CU FT. /F 18 082373 0845 0900 0925 2 A-D 6.0 4.0 50 142.6 64 LOCATIONS: NORTH WALL FOOTINGS. REMARKS: r w w w r r w R fI r w r r r r w r w r w r w r r r r w R w r w r w R w R w R r R r w r r w f w w r w r w r R w R r R r R r r r w a w r r r R w w r w w R w R r w f r r w r R r R w r r r w w w w a w w r R w w w r r r R r r a w w LAB CONCRETE TEST RESULTS CYLINDER CONDITION TEAT D LOAD PSI BREAK TYPE K CYLINDER O. CONDITION TEAT LOAD PSI TYP K E 99C1922 GOOD 7 DAYS 98000 3470 D 99C1923 99C1924 99C1925 REFERENCE ASTM C39, C143, C173, C31 TYPE A:CONE TYPE B:CONE&SPLIT TYPE C:CONE&SHEAR TYPE D:SHEAR TYPE E:COLUMNAR DIAMETER = 6" CROSS SECTIONAL AREA = 28.27 REPORTED TO: CLI NY;S.WINDSOR BIhLDING OFFICIAL;W.J. MOUNTFORD;MOSER, P$$AJNELSO9W40D&CO. t& '�i?n THIS REPORT SHALL.NOT BE USED TO CLAIM PRODUCT ENDORSEMENT BY NVLAP OR� �pyERNMENT AGENCY. THE RESULTS SHOWN ON THIS REPORT RELATE ONLY TO THE THE FOREGOING INFORMATION IS THE PROPERTY OF CLIENTS. REPRODUCTION OR PUBLICATION ONLY WITH OUR EXPRESS PERMISSION. p. SPECIAL TESTING LABORATORIES,INC. EXCLUDES ALL LIABILITY FOR WORK PERFORMED BY OTHERS. Rd AREA OFFICES IN DANBURY-HARTFORD-NEW HAVEN-NEW LONDON VISIT OUR WEB SITE AT www.ucornct.n@t/-@tl r Client: Tolland Bank, Vernon, Connecticut ST L Project: Tolland Bank Plaza, S. Windsor, CT Contractor: W. J. Mountford SPECIAL TESTING LABORATORIES,INC. Inspector: F. Bemis PO Box 200 Bethel,Connecticut 06801 Phone(203)743 7281 Fax(203)7912451 Date: May 4, 1999 Concrete Report CONCRETE INSPECTION WEATHER: LT. RAIN AIR TEMPERATURE: N/A FINE AGGREGATE: COARSE AGGREGATE: CEMENT BRAND: CONCRETE SUPPLIER: N/A CYLINDER PICK UP DATE:N/A CLASS N/A PSI PSI PLANT FIELD CUBIC YD. DESIGN BATCH DESIGN BATCH PREVIOUS YDS. 21.5 CEMENT INSPECTED 0.0 FINE AGO. TOTAL TO DATE 21.5 COARSE AGO. 3/4 START 0700 COARSE AGO. 1/2 FINISH 0900 WATER GALS. TOTAL HOURS 2.0 ADMIX.OZ. SUP.P(OZ.) AGGREGATE GRADING % PASSING 100 50 30 16 8 4 3/8 1/2 3/4 1 1 1/2 FM % MOIST. FINE AGG. COARSE AGG.3/4 COARSE AGG.1/2 #####�#################M###a##########a•r##########a###s####rr#########a###r##�######rr########################## CONCRETE FIELD INSPECTION AND TEST RESULTS TRUCK TICKET TIME TIME OF TIME OF FIELD AIR SLUMP, AIR DENSITY CONC.TEMP NO. NO. BATCHED DISCHARGE TEST SET# CONTENT% INCHES TEMP. LBS. CU FT. •/F N/A LOCATIONS: NIA REMARKS: SCHEDULED CONCRETE INSPECTION WAS CANCELLED THIS DAY BY W.J.MOUNTFORD. LAB CONCRETE TEST RESULTS CYLINDER TESTED TOTAL BREAK CYLINDER TESTED TOTAL BREAK NO. CONDITION AT LOAD PSI TYPE NO. CONDITION AT LOAD PSI TYPE N/A REFERENCE ASTM C39, C143, C173. C31 TYPE A:CONE TYPE B: CONE&SPLIT TYPE C:CONE&SHEAR TYPE D: SHEAR TYPE E:COLUMNAA , DIAMETER = 6 CR ,�$'� �11111C800j, 1 AREA = 28.27 �1 COI11 �♦i♦ ? ' • � e REPORTED TO: I 9 FFICIAL'W MOUNTFORD; MOSE N, No.is Ole *00*0000000 Islas • THE RESULTS SHOWN ON THIS REPORT RELATE ONLY TO THE SAMPLES TESTED. THE FOREdORN001NF0 MALTLION IS THESPROPEERTLYIOF CLIENTS•REPRRODUCTIION OR PUB L CART ANY gONT�YEyR�(aHVERRN.EXPRESS PERMISSION. %• �' 'SF�ECIAL TESTING LABORATORIES,INC. EXCLUDES ALL LIABILITY FOR'WOF� AFORNIED B�07HERS. AREA OFFICES IN DANBURY-HARTFORD-NEW HAVEN-NEW LONDON omr VISIT OUR WEB SITE AT www.uconect.net/"stl .. M Client: Tolland Bank, Vernon, Connecticut ST L Project: Tolland Bank Plaza, S. Windsor, CT Contractor: W. J. Mountford SPECIAL TESTING LABORATORIES,INC. Inspector: E. Zorca PO Box 200 Bethel,Connecticut 06801 Phone(203)743 7281 Fax(203)7912451 Date: April 19, 1999 Concrete Report CONCRETE INSPECTION WEATHER: CLEAR AIR TEMPERATURE:50°F t FINE AGGREGATE: COARSE AGGREGATE: CEMENT BRAND: CONCRETE SUPPLIER: BUILDER'S CONCRETE, INC. CYLINDER PICK UP DATE:4/22/99 CLASS 3000 PSI PSI PLANT FIELD CUBIC YD. DESIGN BATCH DESIGN BATCH PREVIOUS YDS. 13.0 CEMENT INSPECTED 8.5 FINE AGO. TOTAL TO DATE 21.5 COARSE AGO.3/4 START 0700 COARSE AGO. 1/2 FINISH 1100 WATER GALS. TOTAL HOURS 4.0 ADMIX.OZ. SUP.P 1OZ.) AGGREGATE GRADING %PASSING 100 50 30 16 8 4 3/8 1/2 3/4 1 1 1/2 FM %MOIST. FINE AGG. COARSE AGG.3/4 COARSE AGG.1/2 aaiaasasasisilaaaasaaaaasaaiaaaaai##aaasaasaiiias##i##araia#aaaaaaaa!#a#a#isaaals#aai#aaia#alaa!!a!!aalaaaiaa###a CONCRETE FIELD INSPECTION AND TEST RESULTS TRUCK TICKET TIME TIME OF TIME OF FIELD AIR SLUMP, AIR DENSITY CONC.TEMP NO. NO. BATCHED DISCHARGE TEST SET# CONTENT% INCHES TEMP. LES. CU FT. •/F 18 082373 0845 0900 0925 2 A-D 6.0 4.0 50 142.6 64 LOCATIONS: NORTH WALL FOOTINGS. REMARKS: aaiia•a##i4aaliaa!#liia!##■aa#!i###aa!laaaa!#laia!!alailaa!!!!!a!#s!##!!a!!#aa##a!!aalil4i!#aa!#aas!!#!!!a!!!!aa! LAB CONCRETE TEST RESULTS CYLINDER TESTED TOTAL BREAK CYLINDER TESTED TOTAL BREAK NO. CONDITION AT LOAD PSI TYPE NO. CONDITION AT LOAD PSI TYPE 99C1922 GOOD 7 DAYS 98000 3470 D 99C1923 28 DAYS 137000 4850 D 99C1924 28 DAYS 136500 4830 D 99C1925 28 DAYS 133500 4720 D REFERENCE ASTM C39, C143,C1 �y1C�90�t� TYPE A:CONE TYPE 46��Tf TYPE C:CONE&SHEAR TYPE C,kAN� Pe NA/�P%PE E:COLUMNAR . DIAMETER = 6" C SS SECTIONAL AREA = 2 !`��.f�� ,�E{,���� f �A� REPORTED T &IND ICIAL;W.J. MOUNTFO &CO. nl ����s ..,ENS,,. last THE RESULTS SHOWN ON THIS REPORT RELATE ONLY TO THE SAMPLES TESTED. THIS REPORT SHALL NOT BE USED TO CLAIM PRODUCT ENDORSEMENT BY NVLAP OR ANY OTHER GOVERNMENT AGENCY. THE FOREGOING INFORMATION IS THE PROPERTY OF CLIENTS. REPRODUCTION OR PUBLICATION ONLY WITH OUR EXPRESS PERMISSION. SPECIAL TESTING LABORATORIES,INC. EXCLUDES ALL LIABILITY FOR WORK PERFORMED BY OTHERS. AREA OFFICES IN DANBURY-HARTFORD-NEW HAVEN-NEW LONDON If VISIT OUR WEB SITE AT www.uconect.net/-stl Client: Tolland Bank, Vernon, Connecticut 1061-5-S T L Project: Tolland Bank Plaza, S. Windsor, CT Contractor: W. J. Mountford SPECIAL TESTING LABORATORIES,INC. Inspector: J. McGuinness PO Box 200 Bethel,Connecticut 06801 Phone(203)743 7281 Fax(203)7912451 Date: May 6, 1999 Concrete Report CONCRETE INSPECTION WEATHER: CLEAR AIR TEMPERATURE: 600 F t FINE AGGREGATE: COARSE AGGREGATE: CEMENT BRAND: CONCRETE SUPPLIER: BUILDERS CONCRETE CYLINDER PICK UP DATE:05/12/99 CLASS 3000 PSI PSI PLANT FIELD CUBIC YD. DESIGN BATCH DESIGN BATCH PREVIOUS YDS. 21.5 CEMENT INSPECTED FINE AGG. TOTAL TO DATE 81.5 60.0 COARSE AGG. 3/4 START COARSE AGG. 1/2 FINISH 0700 WATER GALS. TOTAL HOURS 0900 ADMIX. OZ. 2.0 SUP.P(OZ.1 AGGREGATE GRADING %PASSING 100 50 30 16 8 4 318 1/2 3/4 1 1 1/2 FM %MOIST. FINE AGG. COARSE AGG.3/4 COARSE AGG.1/2 CONCRETE FIELD INSPECTION AND TEST RESULTS TRUCK TICKET TIME TIME OF TIME OF FIELD AIR SLUMP, AIR DENSITY CONC.TEMP NO. NO. BATCHED DISCHARGE TEST SET# CONTENT% INCHES TEMP. LBS. CU FT. "/F 14 082926 0640 0850 0730 3 A-D 5.0 4.0 60 142.6 72 LOCATIONS:SALB ON GRADE COMPLETE. REMARKS: THE CONCRETE POURED STARTED AT 6:00 a.m.,STL INSPECTOR TOOK THE TEST FROM THE LAST TRUCK AS HE WAS SCHEDULED FOR 7:00 a.m. a#aaaaaaaa##a##aa#aaa#aa####a#a###a##aa#aaa#a#a##aa#aaaaa#aaaa##a##aa# ####a#aa#####a#aa#####aaaa###aaa#a##a###a# LAB CONCRETE TEST RESULTS CYLINDER TESTED TOTAL BREAK CYLINDER TESTED TOTAL BREAK NO. CONDITION AT LOAD PSI TYPE NO. CONDITION AT LOAD PSI TYPE 99C2989 GOOD 7 DAYS 97000 3430 D 99C2990 GOOD 28 DAYS 127000 4490 D 99C2991 GOOD 28 DAYS 122000 4320 D 99C2992 GOOD 28 DAYS 123500 4370 D REFERENCE ASTM C39, C143, C173, C31 TYPE A:CONE TYPE B:CONE&SPLIT TYPE C: CONE&SHEAR TYPE D:SHEAR TYPE E:COLUMNAR DIAMETER = 6" CROSS SECTIONAL AREA = 28.27 ���m'�4�YC8ti��d�r •, REPORTED TO: CLIENT; IR13 1 OFFICIAL;W.J. MOUNTFORD; $�QIN^NL§,�IO,GIRARD&CO. ' •"•'�T�` �)�'.•'ire ate ���/.,���,�?�•.�"',�tjl�a Fr'' a to � 1�` i�...'�;` �'� .'��ii ti CENS jj/;��D gyp• ,.VVVsIp �t� .•` _ , RESULTS SHOWN ON THIS REPORT RELATE ONLY � ESTED. r THIS REPO OT BE USED TO CLAIM PRODUCT ENDORSEMENT BY NV OTHER GOVERNMENT AGENCY. •'' 'THE FOREGOING INFORMATION IS THE PROPERTY'OF CLIENTS. REPRODUCTION OR PUBLICATION ONLY WITH OUR EXPRESS PERMISSION. SPECIAL TESTING LABORATORIES,INC. EXCLUDES ALL LIABILITY FOR WORK PERFORMED BY OTHERS. AREA OFFICES IN DANBURY-HARTFORD-NEW HAVEN-NEW LONDON Itd VISIT OUR WEB SITE AT www.uconect.net/"etl ry I D:CL&P TOLLAND DISTRICT FAQ;:86C-871-3366 PAGE R&B ELECTRIC LlectrlCAl CoMractorS P.O.Box 8114 Manchester,CT 00 Phone (W)282-OSM Fax (880)282-0673 L+ Ru8vsV 5 I9q War Cl �+ , .r 0� (noi5er P� lor-� f)eAc,-zor) - r-,ee-r s Q. w ws ry-)0A e- +0 f ergou C .. o uonp-r rrle+er C�,-') L,4 4 or-, ow(Ner 0+ pro f�oe r+ Tin 0 r.),e +0 Coe- ry e-+Pr CA OrN,s ZA myj r •./ 09"06 'DD 00:38 ID:CL&P TOLLAND DISTRICT FAX:860-871—?966 DACE FIGURE 15 Modular Mster Pantile tot Group IMetarlea 81%le-Phase 12040v of 12Wn8v II , IMf>looA OUTDOOR •'i,.�:tii':S$':h. i, r�';' �ft, � ••�:'r,:�:::,i;4:r 12 ''}:I V�r MAX. n max. +� .'M"•'; �f1i;i: .0 ,,a. if;�' . I III .,». . ,Main .k.. � ?h. ,f+llbtiln 3 R. i N•, disconnecI Floor 1 min. disconnect Mtn. I!II Finish grade I I. Service load disconnects,mat►be located above,below,or DeWitt meters. 2. Outdoor Installetlons limited to a mulmum height of 3 vertical socket positions,nct to exceso dimensions shown. I�I Naha: ;ill A. Sketch of meter Panel errutgemente roust be submlfted to CL&P for approval �l prior to Installedom and Ieyout of ogMlpntod. o. Each store,office,apartment or area serviced must bo permanently ma6ed on tho door wlih Ito unique,permanent IdentKlcatlan. This tinigtie identification must be permanent marked on the associated meter socket.on meter socket cover an Inside load disconnect before the meter wlli ba installed. •I G. Ground at service equipment in accordance with NEC Article 250. The grounding slactrodo conductor connection shall be tirade at an 260e401e location In the serrce equipment and not in the meter socket. The grounding electrode conductor shall not be run through the meter socket. D. Maximum height at top of meter Is 6 It. i;. E. MlItlrnum height at bottom of motor. •Indoor 2 ft above floor. •Outdoor 3 ft.above finish grade. I• F. All common areas and aparti-tents hallways of a two fltmliy or muitl-farnily dwelling must have a owners meter socket In accordance with l NEC Section 2111-25.CUP requires a manual lever operated bypass. rdR eyy►ret r AS I � '' 4 t� s' 1540 SULLIVAN AVENUE SOUTH WINDSOR,CT 06074-2786 a.co�' ARLA CODE 860/6442511 FAX 860/644-3781 August 30, 1999 Craig Porter, Vice President Tolland Bank 1665 Ellington Road South Windsor, CT 06074 Dear Mr.Porter. Please be advised that beneficial occupancy is hereby granted for the new commercial building to be known as Tolland Bank, erected at 1665 Ellington Road, South Windsor, CT under Building Permit #25919, as provided by Connecticut General Statute 29-252- 1b-119.5.1. The permanent Certificate of Occupancy will be issued upon the receipt and approval of an as-built site plan and an affidavit of actual final cost. Please be advised that any changes in the building,which constitute violations of the conditions of the permit,will result in revocation of this approval. This occupancy is granted for a period of 60 days, and will expire on October 28, 1999. Very truly yours, John R. Collins Chief Building Official cc: William Lanning, Fire Marshal Sine 1i 1 • Tolland Bank August 26, 1999 Mr. John Collins Building Official Town of South Windsor 1540 Sullivan Avenue South Windsor, Ct. 06074 Dear Mr. Collins, Per our previous telephone conversation, I am submitting this request for a temporary certificate of occupancy for our new Tolland Bank Office located at 1665 Ellington Road which we plan to open on Monday,August 30, 1999.All final grading and landscaping have been completed and Design Professionals have been contracted and started an As-Built that will be submitted to the Town early next week. All furnishings, supplies and bank equipment will be installed over the weekend. As you know, I have scheduled an inspection of our building with your department for tomorrow afternoon and will be ready to provide any further information to you in order for us to receive our certificate of occupancy and open on Monday. rely, orter ce President Mailing Address: Post Office Box 156 ■ Tolland, Connecticut 06084 ■ (860)875-2500 eectric# APPLICATION FOR BUILDING PERMIT Plumbing# 1665 ELLINGT1 ROAD HVAC # 26229 Sprinkler# No. FINAL APPROVALS Estimated Cost Building COMPLETE RED BOXED AREAS Permit Fee $ 7z Engineering TYPE OR MKT ONLY Occupancy Fee $ Affidavit SIGN ON REVERSE SIDE Appr.for CO. Total Fee $ TO BUILDING DEPARTMENT,TOWN OF SOUTH WN)SOR,CT (Additional Cosh $ The undersigned hereby applies to do work according to the following specifications: Jo6 Location ,✓ Lot No. Side of Street Zone Applicant Tel.# J'—�Ik - Address / ��j A NdrV Zip e��« Lic.# D(,o°t 3 e-> Owner fi-/��A �h Address 9s v ,,` F,cAAMI Architect Address Sq.Ft.N w Area: 1st FI. 2nd FL 3rd FI. Total New Area #Rooms #Lavat ies #Bathrooms #Garages Purpose of this permit: w,6)► )OW -l- s od ' A rse/ City Water ❑ ell Septic System ❑ Sewer Ins. H.O. P. Cert. Area I Basement Garage Approved by Date �UseGroup Construction Type ReviNd 1197 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be locate4 the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in whic t uiiding apad its us 's allowed. Signed ; k---- 1 hereby apply for a Certificate of Occupa or thew rk desc in this application for the permit Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS v Location 6/S �', Permit # G DEMOLITION PERMIT REQUIREMENTS Hazardous material survey: Asbestos Lead paint Letters/confirmation of utility disconnect: Electricity Gas Water : public reuse abandon Well reuse abandon* Sewer : public reuse abandon Drain layer permit# (if abandoned) Septic reuse abandon* *These require procedures approved by Health Department Historic District/Commission Approval Certificate Demolition License (Single family house exempted if owner is present for demolition, and assumes all liability . CGS 29-402(c) 1 JUN 09 1999 10:01 FR SD(-r At`dALYS I S 203 235 7007 TO 18SO8 750512 P.01 i01 t Demo(itons i K✓ Nll. i t Y's 1h'r isr Y:. WE GO BEYOND THE CALF. :111ON June 9, 1999 To Whom It May Concem: This letter is to inform you that all telephone equipment, cables, wires and attachments have been removed from: 1665 Ellington Road South W/ndsor, CT This job was performed on June 8, 1999, in response to a request to demolish the above address by: Todd Lessard Tolland Bank Property owners If you have any questions, please feel free to contact me. Sincerely, Trisha Dragan General Office Associate, 1ROC Southern New England Telephone; a4 Deerfield Len -Room 1A1; Meriden, conriecticut 06450 Phone: (203)420-6688; Fax: (203) 235-7007 �* TnT01 00r_:= n i Z0 'd Z T 90 SZS 098 ANUa QNO1"101 T t,- 0 T a2M 66-9 T-Nnr w JUN-14-99 MON 13:04 CONN. LIGHT & POWER FAX NO. 8608713324 P, 02 � `� CaiwecticuL Thy Connr t� ustict l.igh' .11,rl 1'r+.,rr•, ! •:• ti .,. //llt Ught&Power 48 TnUand Stag' Rudd TVRatiJ,cr 06081 1-800•2UG•run() T6 Nortbcnst L:fl]lti.•i. }•r+r Todd R.Tuonii June 14,1999 General Manuger Todd Lessard Tolland Bank 348 Hartford Turnpike Vernon, CT 06066 Subject: Demolition of property at 1665 Ellington Road South Windsor, CT. Dear Mr. Lessard; This is reference to your letter of May 24, 1999 regarding the demolition of the subject building. Please be advised that all Connecticut Light & Power electric facilities to this building have been removed as of June i 1, 1999. If'I can be of further assistance regarding this platter, Please contact me at (860) 871. 3442. Very Truly Yours, Donald Schaefer Field Technicifui Customer Bngineeiing Ref. 5'r900638 �Et d Z T 9@ 9 - ct9g >INtiS QNH1"101 Zt': 01 Q3M 66-9 T—Nn Jun-11 -99 03: 10P mystic air quality 860 449 8860 P_01 t J IF ' �`G A t ft QG M �t�c Air u li t ConBultants, yInc. su L,�P�LOWr '`�' 1204 North Road (Rt. 117) Groton, Connecticut 06340 Mr. Todd Lessard Tolland Bank Fax: 860 875 0512 Re: Post Abatement Inspection Pre-Demolition Review 1665 Ellington Road, South Windsor, Connecticut Dear Mr. Lessard: Yesterday afternoon, our asbestos abatement project monitor and inspector, Bryce Aston, completed the required visual inspection at 1665 Ellington Road in South Windsor, Connecticut for fulfillment of criteria for inspection prior to demolition. This site review was for the purpose of determining if all the asbestos-containing materials cited in the asbestos inspection provided by the contractor were completely removed in order to allow for demolition to go forward, with regard to asbestos issues. ACIyi-aterijls At the time of the site review, the inspector's findings were that all of the stipulated asbestos-containing materials are completely removed from the building. There is no visible asbestos related dust or debris remaining from these materials in the building, as required by US EPA NESHAPS and the State of Connecticut regulations to allow demolition to proceed. A set of air tests was conducted in the containment area in that portion of the building into which other non-asbestos contractors will be re-entering after the removal of the containment plastic. These air tests showed that the airborne concentration of asbestos and asbestos sized fibers were within the acceptable level for reoccupancy (each sample was below 0.01 fibers per cubic centimeter of air). ch, relative to asbestos concerns this structure is ready for demolition as I gas t inspection and abatement instructions to the contractor were complete. i y Ri and Haffey President Communications (24 hours): Office: (860) 449-8903 FAX: (860) 449-8860 Toll Free: 1 (800) 247-7746 website: www.mysticalr.com e-mail-,magc2Caol,eom 170 1 d Z T 90 SL8 09e NNtia QNC1101 Zit_ 0 T aAm 66-9 T-Nnr Sect&# a y� 1. r Kts APPLICATION FOR BUILDING PERMIT Plumbing# /06 FT3 not. 1665 Ellington road l HVAC # 27498 Date: 11/I,P Od Sprinkler# N0' FIM APPROVALS Estimated Cost Building 112,2,10 1 F1: PLETE RED BOXED AREAS Permit Fee $ ADVQ 'ice .� YPE OR PRINT ONLY Occupancy Fee Affidavit IGN ON REVERSE SIDE Appr.for CO. 1 4 4A-- I Total Fee $ /0�Y- TO BU ILDWG DEPARTMENT,TOWN OF SOUTH WINDSOR,CT Additional Cost) The undersigned hereby applies to do work according to the following specifications: Job Location Mir M"" 1,0/. Lot No. Side of Street Zone Applicant R.4,e& I/ Tel# Add ss Zip QZAPV Lic.# Own r Address SYP I/o-4 oo,':" / " ,n w:4�e nM. 9z 10404py Architect Address Sq. Ft.New Area: 1st FI. 21,040 XIX 2nd FI. 3rd Fl. Total New Area Zl W •f/i4' #Rooms #Lavatories #Bathrooms #Garages Purpose of this permit: Fi r &ur Z JOA D&rAV &5KZU QJ 42a City Water ❑ Well ❑ Septic System ❑ Sewer ❑ Ins. H.O. S.P. Cert. Area Basement Garage Approved by 0 W_ Date t 120 On Use Croup Construction Type R*YW 1197 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this building and its use is allowed. Signed'e&- -— I hereby apply for a Certificate of Occupa cy for the work ribed i *thisplicatlion for the permit. Signed DO NOT WRITE BE THIS LINE INSPECTION COMMENTS r � Inspection / Approval Date By Appl Code Description Due Whom Code CommeAt ------------------------------------------------------------------------------- **-27498-B 80,000 P02 UNDERGROUND 12/06/00 CJD A W/PLUMBER E03 ROUGH 12/20/00 CJD A WW/CONTRACTOR-AC CABLE IN PATIENT CARE ROOMS P03 ROUGH 12/26/00 CJD A W/PLUMB.CONTRACTOR E03 ROUGH 12/26/00 CJD A TELEPHONE COMMUNICATIONS B10 FINAL 01/19/01 CJD D FIRE STOP ABOVE CEILING. FIRE MARSHALL TO CHECK NEED FOR SMOKES IN RETURN A. PLENUM B10 FINAL 01/22/01 JRC A CLOSED OUT. **-17072-E 10,000 **-10683-P 15,000 **-17088-E 1,500 DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is h PERMIT# ereby: TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT APPROVE 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Date Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= $13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRESS �r (� _ APPLICANT PHONE# �> � Q � �� %4 N $F,q OWNER 0 f C -c-�/,' �jf✓�-!� ' 10 OWNER ADDRESS IV � 13t*-w lC 74— Al,e- 4 .x OWNER PHONE ESTIMATED COST$ /S"� 2 * V IS THIS A CONTRACT COST? 0"Yees 0 No FEE ENCLOSED$ OR-co �, TYPE OF JOB: XS Original Installation 0 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑ YES ❑ NO ❑RESIDENTIAL ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL ❑ INSTITUTIONAL ENGINEER'S NAME PHONE ❑FACTORY ❑ STORAGE ADDRESS ❑ GARAGE ❑MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF MAIN FEEDERS AND RATING OF WIRE USED NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? ❑YES ❑NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. _ _ I -z � � 106VIO CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE PEWII# DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT 1?07Q- Application is hereby: TOWN of SOUTH WESM SOR DEPARTMENT A BUILDING DEPARTMENT Bldg Permit# _jP�RAPPROVED 1540 SULLIVAN AVENUE O 644-2511 ext.230 t Date Building Inspector F Application must be pninted or typed Location of job t&7 Street No. Street Lot No. fin. �-����m,�� ���� FEE SCHEDULE Floor Apt.No. $0 - $1,000 - $12.00 Over $1,000 13,00 '0105 $12.00 per$1,000 6.00 q0 "�40LW—r OWNER or any fraction thereof ADDRESS OWNERS PHONE#— APPLICANT ADDRESS ESTIMATED COST *dV 0 , IS THIS A CONTRACT COST? —1 "'� ` YES NO FEE ENCLOSED $ XY y00 so R-CO TYPE OF JOB: Original Installation Alteration/Addition Repair Revised 11/95 APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A RESIDENTIAL BUILDING PERMIT APPLICATION YES / NO BUSINESS ASSEMBLY CURRENT USE AND OCCUPANCY EMOTL1 SDACE MERCANTILE _� r�'� �(-� EDUCATIONAL FUTURE USE AND OCCUPANCY �� C�iLcr— INSTITUTIONAL FACTORY STORAGE ENGINEER'S NAME PHONE GARAGE MIXED USE ADDRESS CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD :t ,V//A (�l�2E i9 tile, SIZE OF MAIN FEEDERS AND RATING OF WIRE USED �Xi� NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED?YES NO NUMBER OF LIGHT CIRCUITS r NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS 3/ NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPERATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK a,2 lP7S 4!�—:7,re T V �4 THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH 7!V-tr-X16A1 NAME STATE LICENSE NO. TYPE OF APPLICANT PHONE NO,oWe '07�/�"�•�/c�— DATE -CIO DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: /y(o g� BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# U U 644-2511 ext. 230 0?? y`� Date Building Inspector Application must be printed or typed F$0F EE Location of Job: SCHEDULE / -$1,000=$13.00 Street No. Street Lot No. Over$1,000= $13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT OSli� �''_1.L�.� L7 P/r'IL Ch'g�i�� S✓cS iLG APPLICANT ADDRESS /?O SOY 331 Y- e 33 9 APPLICANT PHONE# �0.11 O W N S F OWNER ,q OWNER ADDRESS O F, OWNER PHONE ESTIMATED COST$ l,s, 0,0 0, J)6 IS THIS A CONTRACT COST? XYes 13 No �CJ FEE ENCLOSED$ 00 O�� TYPE OF JOB: OR•C New Installation 0 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A ❑RESIDENTIAL BUILDING PERMIT APPLICATION?X YES ❑NO ABUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL ❑INSTITUTIONAL ENGINEER'S NAMEa✓Gia�lyrj?,, rPHONE f -WJ-- Sg s ❑FACTORY ❑STORAGE ADDRESS_,�� %I'1h riy 17- ❑GARAGE ❑MIXED USE CITY L,15 r- STATE ZIP 196 I J e (Other please specify) TYPE OF INSTALLATION fj SIZE OF MAIN DRAIN �iin. ,S TiD NO.OF TOILETS-- STYLE A-,O NO.URINALS STYLE NO.OF BATHTUBS �_ NO.OF SHOWERS NO.OF LAVATORIES NO.OF CONDUCTORS C> SIZE D NO.OF STACKS SIZE AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES t' _ , 1 �i'► /I a `S ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW ❑Y4 XNO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK SIZE OF WATER MAIN SIZE/r SIZE OF WATER PIPING&RISER 3 WATER HEATER: TYPE a2D a,41 rG MANUFACTURER S/'V1 TX DESCRIPTION OF WORK -"11011,/G ��' SC/?°• �U /�i�lJ �9GC !,y//t/L THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. eQ0,Y)q ?- / CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE �� 4 4 i } t DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT I PERMIT# i Application is hereby: TOWN OF SOUTH WINDSOR O i BUILDING DEPARTMENT ! APPR v 1540 SULLIVAN AVENUE Bldg.Permit# �2 12 644-2511 ext. 230 ' Date Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: I(0(5 �Lb Al!j -j-bj 20 $0-$1,000=$13.00 Street No. " Street Lot No. Over$1,000= $13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT 0 IV o j m APPLICANT ADDRESS -*-)6 - 3 uat�a�5 r -#) APPLICANT PHONE# %sfv A- (o q 3- Z 4 If Z, OWN S F OWNER r 4:�e Pry M '4< OWNER ADDRESS ) !� OWNER PHONE C ESTIMATED COST$ -7 ooD U IS THIS A CONTRACT COST? /&Ves 0 No FEE ENCLOSED$ 00 TYPE OF JOB: OR-CO 0 Original Installation Alteration/Addition/Repair Revised 8/99 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: .HEATING ❑RESIDENTIAL AAIC ❑ COMMERCIAL VENTILATION ❑ INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑ HYDRONIC ❑ WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) TYPE OF FUEL ❑ OIL-GPM ❑ GAS-INPUT ❑ ELECTRIC-KW OIL TANK SIZE&LOCATION ❑ INSIDE ❑ OUTSIDE CAPACITY LPG TANK CAPACITY AIR CONDITIONING DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) Ufa--1( ���� w C)2 OIL(` TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. �)Q3 20 :) 5- 1 c__r CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE + APPLICATION FOR PERMANENT SIGN PERMIT oning royal: 1665 Ellington Road Est. Cost: SV;-O 0 Ref. 11,9 C-) No. 2 7 5 9 9 - Permit Fee: Final Inspections: Approved: Building — Electric # Zonin o%, Applicant Name 1 Z S�An cennec'4TWA, ��c• S02 7 rn� p Address Phone S`'w Conn. k-ZO-05S- 41 To R1erh-r-of Location of Sign a// Moa4 4-y ( mo j &n Zone Sign Size (square feet) Sign Height # of signs on site: Free-standing Wall TYPE of SIGN: A it Wall or❑ Free-standing New or❑ Replacement Illuminated? Yes ❑ No Description of sign materials and lighting: S-Iah7dlad C 0XPel i���Min ot, avGh 1 'e'r. cra.I I Y wel _ I- L(!:4e Ca MP�►'L ATTACH I DIAGRAM OF -� a oZ X �LI,e d ✓nGLt�fn 2]C,/Sti �i rl n° 41P��g _ SIGN INCLUDING al-t DIMENSIONS have read, understand and agree to ide by the South Windsor Zoning Regulations, Signs. SIGNATURE 'S«IV CoA)A)-�56 7/o JINCDate U� v1 Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-27599-B 2,500 B10 FINAL 10/04/01 JRC A CLOSED OUT. Bectric# APPLICATION FOR BUILDING PERMIT Plumbing# 1665 Ellington Road HVAC # No. 28440 Date: 12 ' Z G - O k Sprinkler# FINAL APP V LS Estimated Cost $ 3 0 0 e_°s Building oZ COMPLETE RED BOXED AREAS Permit Fee $ 3q. �"'Wng TYPE OR PRINT ONLY Occupancy Fee Affidavit SIGN ON REVERSE SIDE C19 Appr.for CO. -o Total Fee $ /� TO BuLDING A imiw,TOWN OF SOUTH WTI zm CT (Additional Cost) $ The undersigned hereby applies to do work according to the following specification Job Location I Co G S C `\ %�c Z o N Z O . Lot No. Side of Street Zone Applicant L-C N CC)3- - Tel.# 0 -G %i Addr ss I Z +�k s� S /YA,c 1e s+C C Zip 06 0-i o Lic.# Owner-V0 V A,i e) Address kf C S Architect <Cl Address I-Z t�- i s vo 1\ /�h-,%c 1a 3 A-c. r C'T o C a y-? Sq.Ft.New Area: 1st FL 2nd FI. 3rd Fl. Total New Area so #Rooms #Lavatories #Bathrooms #Garages Purpose of this permit: A o r- TA \a -C;� 47� eX\SA e-,--c i c q I SFmCQ �Tc� .,uc \vc�e New C\ e-N1 3C e - e.w, C)eC(?e aD Cty Water ❑ Well ❑ Septic System ❑ Sewer ❑ Ins. H.O. S.P. Cert. Area Basement Garage Approved by Date/.2-,G-a/ Use Croup (5 Construction Type Revised 9/01 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in wbch thi uil C11-4 ands is allowed. Signed I hereby apply for a Certificate of cu for wo d ibed in this application for the permit. ,Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-28440-B 3,000 E03 ROUGH O1/03/02 CJD A W/OWNER B10 FINAL O1/03/02 CJD A W/OWNER- FIRE MARSHALL WALK THROUGH? B10 FINAL O1/04/02 CJD A CLOSED OUT. B10 FINAL O1/04/02 CJD A CLOSED OUT. APPLICATION FOR PERMANENT SIGN PERMIT Zoning Approval: 1665 Ellington Road gpa Est. Cost: $ dA_ AV No. 28445 Permit Fee: $ sUd R f. Approved: Final Inspections: Electric # Buildin Z o n i n wo�- Applicant Name �ar`l '� �o✓S! ..»��✓S g ��tThS,�i�t/6 Address SST ST. ST,D - �� S e Phone —d ��I' -9 -- g v Location of Sign done G Sign Size (square feet) Sign Height # of signs on site: Free-standing .ZWall TYPE of SIGN: e Wall or ❑ Free-standing g New or ❑ Replacement Illuminated?V Yes ❑ No Description of sign materials and lighting: W 4/W C1,14AIA1,61.me ATTACH DIAGRAM OF SIGN �l-!il/ C./`/•C/G C/��T'rfO E�iYI�a�7/� �i4�0/'�S2itiJ C L U D I N G vas jF:�� 7'�/Lt.oT'G�/ ! /ST�7/G S���.O 6 nMENSION S I have read, understand and agree to abide by the South Windsor Zoning Regulations, Signs. SIGNATUR s/ S Date / �'��3y1d�c.��✓� G�C Yvi�19 �✓o'� s�/��9 7dGls��lc�9�0 e, ls vv 0� 0ff cer i�•,_ � �.�� ,it DEMONAPPLICATION FOR ELECTRICAL PERMIT PERMIT# TOWN OF SOUTH WINDSOR ss BUILDING DEPARTMENT 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Application n must be printed or typed ' � rt �"�;k •;ate,_' .S �,-.' T;;a . Location of Job: ti -7 MAt Street No. Street Lot No.000 � at 7114 beef Tenant Designation Apt.No. APPLICANT 7• Selle IwA, ==1 APPLICANT ADDRESS I''.Gi �11�C O y7 �� /�l'GlrlCd�y �'�►'. sox tal A--'0 Cr 0 epo7V APPLICANT PHONE# /- cog G OWNER r ��= ,wq;;�; } •r - ` OWNER ADDRESS (0 ;,3}`''¢_1.. �`vim.= " ,� �� �/ T/ ✓ /I' �0�� / OWNER PHONE ESTEWAT ED COST$ IS THIS A CONTRACT COST? Yes 0 No ' f r ENCLOSED$FEE 4. �— "k�-�� - . .{ f ;• � TYPE 7Bjnstalation 0 Altuation�Addition/Repair'�, . � ,t, :, • Revised 8/99 n• e rya. APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BiTTi.DING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? YYES ❑NO ❑RESIDENTIAL ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL ❑INSTITUTIONAL ENGINEER'S NAME PHONE ❑FACTORY ❑ STORAGE ADDRESS ❑GARAGE ❑MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF SERVICE SIZE OF MAIN CONDUCTORS NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? ❑YES ❑NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK fV1-S 1�m �;kvlcle 6-0,14 if /'161% e� oft J,� 1 (6 Ak THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. /0?0�03 ' CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE l aA,