Loading...
HomeMy WebLinkAbout12 Gilbert Lane 6ecthc# 1(0 R l? APPLICATION FOR BUILDING PERMIT Plumbing# D(0 a 12 Gilbert Vane HVAC # /G ' /oB�SA� 26920 Dat Sprinkler# NO' Building COMPLETE RED BOXED AREAS permit Fee t ( 66 Engineering TYPE OR PRINT ONLY Occupancy Fee $ Affidavit SIGN ON REVERSE S®E Appr.for CO. Total Fee TO BULDNG DEPARTMENT,TOWN OF SOUTH WHSOR,CT (Additional Cost) $ The undersigned hereby applies to.do work according to the following specifications: Job Location Lot No. Side of Street Zone - Applicant ` Tel#JIB Address r"Y Olt- Zip 0 Lic.# S nn IS-6 Owner L _ .�� 1J .�'�+� 3►V-,Address Architect Address Sq.Ft.New Area: 1st Fl. 2nd Fl. to S. , 3rd Fl. Total New Area l;"O #Rooms #Lavatories #Bathrooms #Garages Purpose of this permit: _ ' City Water W 11 ❑ Septic Syst m ❑ Sewer, Ins. H.O. Cert. Area U40°I2 Basement 10D FA- Approved 6y Dat ll loo Use Group K4 "- RwiNd 1197 e I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this building and its use is allowed. SignedA,9Wav-x-9w4, .A11,,C"j0 I hereby apply for a Certificate of Occupancy for the work described in this application for the permit. Signe DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Location of Job: AFFIDAVIT Additional Fee$ 338. 00 State of Connecticut ss.South Windsor County of Hartford _ Owner 1 /f �" C. 0jU,,v`�' of CJ�J�J rv— L� ����' �/�I/ gent for the building erected Contractor under Permit No. 26920 issued by the Building Department of the Town of South Windsor being duly sworn,make oath and say that the actual cost of the completed work autho ' d under said permit did not exceed the most current accepted BOCA value of S 158 ,298 .36 �. Signe 10 "y Subscribed and sworn to before me this day of A.D.20 (mated Cost S 13 2,'6 0 0. 0 0 Difference: $ 25r698. 36 Notary Public Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-26920-B 120,000 B02 FOUNDATION 06/13/00 DCJ D NOT DONE B02 FOUNDATION 06/14/00 DCJ D FOOTING DRAINS NOT COMPLETE B02 FOUNDATION 06/14/00 DCJ A BACKFILL FRONT AND RIGHT SIDE ONLY B02 FOUNDATION 06/20/00 DCJ A BACK WALL P02 UNDERGROUND 07/17/00 CJD A E01 SERVICE 07/20/00 JFF A NOTIFIED NU OK B05 FIREPLACE/CHIMNEY 07/20/00 JFF A WITH CONTRACTOR B03 FRAMING (ROUGH) 07/31/00 CJD A W/ROGER-NEED SPEC SHEETS FOR LAMS P03 ROUGH 08/09/00 DCJ A E03 ROUGH 08/10/00 DCJ A B04 INSULATION 08/17/00 DCJ A PO4 GAS TEST 09/13/00 JFF A LEFT APPROVAL STICKER WITH TIM IMPERIAL B10 FINAL 09/27/00 DCJ D FINISH SIDING,KITCH CIRCUIT,SMOKE IN DEN, CAT WALK IN ATTIC,SUPPORT AT END OF LVL B10 FINAL 09/28/00 DCJ A **-10854-H 3,000 **-10627-P 3,000 **-10875-H 6,600 i I I I I 1 w ELI a IT Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-26920-B 120,000 B02 FOUNDATION 06/13/00 DCJ D NOT DONE B02 FOUNDATION 06/14/00 DCJ D FOOTING DRAINS NOT COMPLETE B02 FOUNDATION 06/14/00 DCJ A BACKFILL FRONT AND RIGHT SIDE ONLY B02 FOUNDATION 06/20/00 DCJ A BACK WALL P02 UNDERGROUND 07/17/00 CJD A E01 SERVICE 07/20/00 JFF A NOTIFIED NU OK B05 FIREPLACE/CHIMNEY 07/20/00 JFF A WITH CONTRACTOR B03 FRAMING (ROUGH) 07/31/00 CJD A W/ROGER-NEED SPEC SHEETS FOR LAMS P03 ROUGH 08/09/00 DCJ A E03 ROUGH 08/10/00 DCJ A B04 INSULATION 08/17/00 DCJ A PO4 GAS TEST 09/13/00 JFF A LEFT APPROVAL STICKER WITH TIM IMPERIAL **-10854-H 3,000 **-10627-P 3,000 **-10875-H 6,600 Total Est Value 132,600 Dwelling 2,692 129,969.76 Basement 1,430 20,306.00 Garage 528 7,497.60 Smoke Det 7 525.00 BOCA Value 158,298.36 Difference 25,698.36 i f : a { Town Of South Windsor Engineering Department 1540 Sullivan Avenue South Windsor,CT 06074 To Whom It May Concern: We,the Buyers of Lot# 15 ,also known a& located in the Deming Hill Estates,in South Windsor,CT,on this 28th day of September ,2000, hereby grant permission to the Town Of South Windsor and its agents or assigns,and J.M.J.Construction Co.,Inc. (Seller)to enter onto above said property for the purpose of completing any and all site work,per Town Specification,such as grading,raking, seeding,driveway,etc. BUYER xoT� �&pTARY PUBLIC S C My commission expires Apr.30,200, BUYER SITE COMPLIANCE CHECKLIST i -D TOWN of SOUTH WINDSOR, CONNECTICUT ` j 12 GILBERT LANE LOT_##15 Reviewed By PERNA En ineering) JMJ CONSTRUCTION CO. Date Reviewed 9 7 pproved Denied 658 ELLINGTON ROAD,SOUTH WINDSOR,CT Reviewed By _ nning) BP_#_26920_ Ph_#_(860)282-0628 Date Reviewed 4 0J Approved enied Date Submitted 00/00/00 ***** FOR C of 0 ** As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1. Approved building permit plan 2. Finish grading per approved cwuk 1N Faa> building permit plan 3. Site work; i.e. trees, shrubs, caJL►v*)Lk0 / dumpsters, required parking 4. Utility location; a. sanitary sewer/septic system b. foundation drain vAwL C. electrical & telephone d. water e. other 5. Sewer connection charge paid SJzzjcv 6. Appropriate certification 7. Bonding 8. Planning & Zoning/ Inland Wetlands Considerations A. Lighting B. Signage Freestanding Wall C. Fee in lieu of Open Space Sewer Permit No. j Pavement Excavation No. COMMENTS: 06 LAw►J iS setp#D +A""'> M v faewj-D SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT $/i 12 GILBERT LANE LOT_#15 Reviewed By `�G- .�%- 4(Enin' ng) JMJ CONSTRUCTION CO. Date Reviewed mo e 658 ELLINGTON ROAD,SOUTH WINDSOR,CT Reviewed By 1 ) BP_#_26920_ Ph_#_(860)282-0628 Date Reviewe S Gk*> pprove Denied Date Submitted 04/25/00 ***** FOR BU L ING PE **** In accordance with the Zoning and/or Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include: Approved Denied N/A 1. Name, address & phone number of owner/applicant 2. Name, address & phone number of plan preparer 3. Zoning Information - i.e. zone, open space, floodway, street address. 4. Plot Plan at 1" = 40' scale a. Subdivision reference, abutting properties, etc b. Easements of record c. Lot description, bearings, building lines, distances, area, etc. d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate e. Building location with dimensions. Elevations of proposed finish floor, garage floor & centerline of road at driveway f. Elevations of gravity drainage systems, sanitary & foundation drain at the house and the street g. Tentative utility location (gas, water, electric, septic system, etc.) h. Title block with name and address of preparer, date, appropriate certification, live seal and live signature consistent with the Board of Registration requirements. (P.E. & L.S.) 5. Sedimentation and erosion control 6. Special Planning & Zoning, Inland/Wetlands considerations (Plans on file w/Town Clerk) COMMENTS: � MAY 22 r M� r �_•.� Xw i>P/ �/`tea SOUTH F s wig � y/z0/ �•� KEPT i� S DEPARTMENT DECISION PERMIT# APPLICATION FOR ELECTRICAL PERMIT -17 Application is hereby: TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Permit# QPPROVE 1540 SULLIVAN AVENUE .2G a2G -- Q� 644-2511 ext.230 Date Building Inspector Application must be printed or typed Location of job Street No. Street Lot No. FEE SCHEDULE Floor Apt.No. $0 $12000 - $12.00 Over $1,000 mom $12.00 per$1,000 OWNERr/ C�,Sc�o,�or any fraction thereof ADDRESS �. l'!%wofo� ��• ©GOB OWNERS PHONE APPLICANT i °"� �-• MOM ADDRESS l <q _•�:'••� 'T- • Gas✓�-�oeo,��� -�- dG -�� � •v. v�r•r• r�r•: ESTIMATED COSTS Q C f IS THIS A CONTRACT COST? YES NO FEE ENCLOSED $ f;Z SOR-CO� TYPE OF JOB: Original Installation Alteration/Addition/Repair Revised 11/95 i I i APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A RESIDENTIAL BUILDING PERMIT APPLICATION YES / NO BUSINESS ASSEMBLY CURRENT USE AND OCCUPANCY MERCANTILE EDUCATIONAL FUTURE USE AND OCCUPANCY INSTITUTIONAL FACTORY STORAGE ENGINEER'S NAME PHONE GARAGE MIXED USE ADDRESS CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF MAIN FEEDERS AND RATING OF WIRE USED NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS / REMOTE DISCONNECT REQUIRED?YES0-01) NUMBER OF LIGHT CIRCUITS S� NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS 9 NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS D,'c NUMBER OF A/C CIRCUITS Q SEPERATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESC TION OF WORK 6 THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILD G CODE THE PERFORMANCE OF SUCH WORK. NAME STATE LICENSE NO. TYPE IGNATUkE CrF PHONE NO.z; 1-2,1,1fj251' D TE �G/� INSPECTOR __ DATE TIME - / ! LOCATION o� " INSPECTION: CODE: RESULT(D/A) : BUILDING: ELECTRICAL: C.1 PLUMBING: HVAC: OTHER: i DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR 16600 BUILDING DEPARTMENT APPROVE 1540 SULLIVAN AVENUE Bldg.Permit# -7 1 &) "IS OL 644-2511 ext. 230 a O Date Building Inspector i Application must be printed or typed J FEE SCHEDULE ` Location of Job: LQ $0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= $13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRESS 2 . . Vo APPLICANT PHONE# N S OWNER C C �0 OWNER ADDRESS C\�� FIL ' OWNER PHONE C ESTIMATED COST$ U l 6 IS THIS A CONTRACT COST? Yes 0 No �. s ,o FEE ENCLOSED$ TYPE OF JOB: SOR.CO /� O New Installation 0 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH RESIDENTIAL A� BUILDING PERMIT APPLICATION? ❑ YES � O ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL ❑INSTITUTIONAL ENGINEER'S NAME PHONE ❑FACTORY ❑ STORAGE ADDRESS ❑GARAGE ❑MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION SIZE OF MAIN DRAIN NO.OF TOILETS STYLE NO.URINALS STYLE NO.OF BATHTUBS NO.OF SHOWERS�_ NO.OF LAVATORIES NO.OF CONDUCTORS�_ SIZE VI' NO.OF STACKS SIZE AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW l YES ❑NO SIZE OF WINDOW Z IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS - SEWE OR SEPTIC TANK SIZE OF WATER MAIN * SIZE OF WATER PIPING&RISER WATER HEATER: TYPE MANUFACTURER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. �2-(3 !S O� q�_e- � CONTRACTORS LICENSE NO. TYPE STATE r` 1 2 a SIGNATURE OF APPLICANT � �.a�,� �Q ! �' ���, DATE v ` n DEPARTMENT DECISION APPLICATION_FOR HVAC PERMIT PERK Application is hereby: TOWN of SOUTH W NDSOR BUR DING DEPARTMENT Bldg Peter# APPRO 1540 SULLIVAN AVENUE . . _ 644-2511 ext.230 -- Date Building Inspector Application must be printed or typed Location ofjcb lg SIreet F No. Street LAW FEE SCHEDULE ` Floor Apt-No. $0 - $1,000 - $12.00 Over $1,000 $12.00 per$1,000 OWNER 'f or any fraction thereof ADDRESS \ OWNERS PHONE# C) APPLICANT ��000 �x 000 W N S ADDRESS � Sy\\W"�:� , oD . ESTIlVIATED COST $ IS THIS A CONTRACT COST? YES NO ` C1 FEE ENCLOSED $ �SOR,Cps TYPE OF JOB: . Original Installation , Alteration Addition Repair _ Robed IIN5 APPLICATION FOR HVAC PERMIT(Continued from reverse side) TYPE OF SYSTEM TYPE OF BUILDING HEATING RESIDENTIAL � A/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC ✓ WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE F INSIDE F DIFFERENCE F TOTAL HEAT LOSS(BTUH) (HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY (INPUT—BTUH) NET RATING (OUTPUT-BTUH) TYPE OF FUEL OIL—GPM GAS-INPUT ELECTRIC—KW OIL TANK SIZE&LOCATION INSIDE OUTSIDE CAPACITY LPG TANK CAPACITY AIR CONDITIONING DESIGN TEMP. OUTSIDE F INSIDE F DIFFERENCE F TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. O 2 STATE LIC NSE-NO.NAME&TYPE SIGNATURE OF APPLICANT PHONE NO. DATE p �—0 c3 p TI s 8 J'A CALCULATION SHEET 1503 (Modern MothOd) 'v /\ ---�- Coyr./Mt 1977 bw The HYdrowies institute owNslt- �--` C L.A ADDRESS DESIGN TEMPERATURE DIFFERENCE. Is. DATE U LJ C OL-s C L.C C L.D C L.E C L.F t A OA1 COL.a t Z D ►+ L w H L w H L W H L w H L w aw•was"T.w�. %2 ROOM DIMENSIONS.FT.' 1- b L 2 LENGTH ExFOSEO WALLS,f T. V s3 t O SITUw per Feel f ! 2 WINDOW AND OUTSIDE DOOR AREA Aalletlee Saested o• a I STUN STUN BTU STUN sTUH S WALL CONSTRUCTION � (Table f,Ltwa S s MI 40 I�pDO � goo OO � � ROOM LIN.FT.IOF J S TYPE OF LASS � 'o TOTALS RAOIAT;ogN (seteaw of 9000 WOW fei L ino S) czx � /SD/) FROM LINE 12 SELEC 29 7 CEILIN CONSTRUCTIONy o-a �/ Gov Soo . (TMia t.L.W, D ADD 8'aD UlJ S ` u 7 E FLOOR CONSTRUCTI Nt O gel ej ITa0/e1L L a w w L1w FU - •_- B COLOFARTITION CONSTRUCTION E 11r0b a s.L a N) ,__ _� r _ F •�f �Dd t € t Woo twlw O0ed,Ip 0 a 2taaahnl :x ' �� H v Z oU a'"''�""" o•«�tB+ 3 •f EAL Hall LZOt'> 1 • It tOT/1LE1T11M1AT;7fll�Tlf�1►•OfffERENGE•� O 30 7i��> 70G �QQ 12 T TAL GTUN AT OESI N Moir.DIFFE MINCE 0,000 - o K • L __ C L.A COL-2 COL.H COL.1 COL.J COL.K ,"'�.`�." ''_' C OL.L TO AL sTt1M T TAIL t ROOM -•---- — �.,..__ ' E C/ O e OF BUILDING RA IATION O N w H L w H L W H L w H AT ELECTED 2 ROOM DIMENSIONS.FT. H L w DESIGN Tamp.* /�,l / f y 0 ol�FEwE1+sCE' . S LENGTN EXPOSE WALLS.FT. O S WANDOW AND OUTSIDE OOR AREA 16 r 3� S WALL CONSTRUCTION STUN STUH ATUH .STUN BTU" ITylsl.Lme3 a N) i1J Soo -INCREASE BATHROOM E TYPE F GLASS --- d TOZAL 20% !s«MIwN table 11119111111100 L!no III 7 CEILING CONSTRUCTION - '—'—" � � , (Table S.L a W1 .O C O ` tFOR CONCRETE FLOOR ON .J U GROVNO ON FILL AT • FLOOR C Is W Of in PLI — GRAVE LEVEL.USE LINEAR 96 (Table�•L s w aw Lin f tI 9 COLD IARTfTION CONSTRUCTION FEET Of_ - ExPOSEO EDGE (Table If,L a HI ------ —� • 10 4 I WON(w.m oOaM,vo 00 I X 3waMnvftbooeenfy Ent HailJ D II TOTAL STUN AT 70F TEIr1P. DIFFERENCE* 3 12 TOTAL BTUH AT DESIGN TEMP.DIFFERENCE o Tawo fnt Is avMIa01 fromTwa Nya, nit I O O� - s institute.2S Ausso Place.Ba.taey HaI/htt•N.J 07922 FORM 1303 f. y DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR �- BUILDING DEPARTMENT 1540 SULLIVAN AVENUE Bldg.Permit# cirw644-2511 ext. 230 (03 D e Building Inspector Application must be printed or typed FEE SCHEDULELocation of Job: / 671 /`er� $0-$1,000=$13.00 Street No. /J Street Lot No. Over$1,000= $13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT -4- a T,c1 •E- �',v APPLICANT ADDRESS 3/D Alej Z:Weee Rg o ?'4l APPLICANT PHONE# �_� OWN S F,4 OWNER `� e OWNER ADDRESS _ ,v O OWNER PHONE ESTIMATED COST$ 2 IS THIS A CONTRACT COST? OrYes 0 No ICJ FEE ENCLOSED$ TYPE OF JOB: s�R CO Mr<ew Installation 13 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: ❑HEATING UrkESIDENTIAL ffl A/C ❑COMMERCIAL ❑VENTILATION ❑INDUSTRIAL ATING ❑STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT �BS. ❑ RONIC ❑WARM AIR Cl UNIT RADIANT HEATER EXIST DIATION ADDITIONAL RADIATION TOTA IATION DESIGN TE UTSIDE OF INSIDE OF FERENCE OF TOTAL HEAT LOS TUH) °F(HEAT LOSS SHEET MU CCOMPANY APPLICATION) DESCRIBE ALL HEATING IPMENT(INCL G MAKE&MODEL NO.) GROSS HEATING CAPACIT PUT-BTUH) NE TING(OUTPUT-BTUH) TYPE OF FUEL ❑ -GPM OIL TANK LOCATION:❑INSIDE❑ OUTSIDE CITY GAS-INPUT LPG TANK CAPACITY ELECTRIC-K AIR CONDITIONING DESIGN TEMP.OUTSIDE 15P iZ OF INSIDE_7 OF DIFFERENCE / OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING E UIPMENT(INCLUDING MAKE&MODEL NO.) Ile-."L (2 a y d P-v so r-- O/e TONNAGE_ COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) Y TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK 6a�1,C� !,n.y7�- L THE UNDE IGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. ,,,, c 05?7� b — / C�l- CONTRACTORS LICENSE NO. TYPE STATE , p SIGNATURE OF APPLICANT DATE ,Lod DETAILED REPORT FOR ENTIRE HOUSE Prepared For : Prepared BY: Clark Realty RP 658 Ellington Rd R&E Heating & Cooling So Windsor Ct 06074 Job Name: 243-015 EXPOSURE GLASS NORTH NE/NW EAST SOUTH SE/SW WEST HORZ . TOTAL ___________________________________________________________________________ AREA ; 18 : 0 ; 121 : 20 ; 0 ; 146 ; 0 ; 305 COOLING ; 242 : 0 ; 5 ,254 : 428 ; 0 ; 6 ,340 : 0 ; 12 ,264 HEATING ; 722 , 0 ; 4 ,855 : 802 : 0 ; 51858 : 0 ; 12 ,237 ______________________________________________----.-_-----.---_-.__________________ BELOW WALLS NORTH NE/NW EAST SOUTH SE/SW WEST GRADE TOTAL --------------------------------------------------------------------------- AREA ; 562 : 0 ; 431 , 364 : 0 ; 941 : 0 ; 2 ,298 COOLING ; 388 ; 0 ; 298 : 252 , 0 ; 650 , 0 ; 1 ,58811 HEATING ; 11591 ; 0 ; 1 ,220 : 1 ,030 ; 0 ; 2 ,664 : 0 ; 6 ,506 --------------------------------------------------------------------------- DOORS NORTH NE/NW EAST SOUTH SE/SW WEST TOTAL ---------------------------------------------------------------------------- AREA ; 0 ; 0 ; 21 ; 0 ; 0 ; 21 : ; 42 COOLING ; 0 ; 0 ; 108 : 0 ; 0 ; 108 ; ; 216 HEATING ; 0 ; 0 ; 443 ; 0 ; 0 ; 443 ; ; 885 w_______________-w_________-__-__-_-___________-_______-___________________ FLOOR AREA COOLING HEATING .____---------.-______________-______________-____________-_____________________ 2120 ; 0 ; 0 ___-_---------------------------.__________________________________--__________________ CEILING AREA COOLING HEATING ____________-_____________________-__________w___________----__-___________ 2120 ; 1 ,280 ; 2 ,352 __________________________-_________________--------________________________ MISCELLANEOUS COOLING LOADS --------------------------- People Sensible Load 4 ,500 Latent Load 8 ,822 Lights & Appl . Load 4 ,778 Latent Safety Btuh 441 Ventilation Load 2 ,860 Duct Heat Gain 957 Infiltration Load 963 Sensible Safety Btuh 1 ,422 TOTAL SENSIBLE LOAD 30 ,829 TOTAL LATENT LOAD 9 ,263 Air Changes/Hour 0 .50 Temp . Swing Mult . 1 .00 ** Total Cooling Load 40 ,092 BTUH Or 3 .34 Tons *** MISCELLANEOUS HEATING LOADS _------_______________________ Infiltration Load 13 ,096 Ventilation Loam Duct Heat Loss 2 ,622 Safety Btuh S G"N A N NE D *** Total Heating Load 59 ,872 BTU - SUMMARY REPORT -------------- Prepared For : Prepared By: Clark Realty RP 658 Ellington Rd R&E Heating & Cooling So Windsor Ct 06074 Job Name: 243-015 DESIGN CONDITIONS ----------------- OUTDOOR INDOOR SUMMER WINTER SUMMER WINTER Dry Bulb 88 0 78 68 Wet Bulb 75 65 Daily Range 20 Daily Swing 3 .0 Latitude 41 Elevation 1100 Safety Factor ( % ) 5 Latent Factor ( % ) 30 Room Heating Heating Cooling Cooling Name BTUH CFM BTUH CFM Living/dining 4 ,756 127 31910 203 Kitchen 10 ,910 292 4 ,459 231 Family Room 6 ,919 185 4 ,023 209 Bed 5/Den 9 ,849 263 4 ,198 218 foyer 3 ,638 97 3 ,230 168 Bedroom 1 16 ,440 439 5 ,637 293 Bedroom 2 2 ,528 68 15979 103 Bedroom 3 2 ,464 66 1 ,454 75 bed 4 2 ,367 63 1 ,940 101 59 ,872 1 ,600 30 ,829 1 ,600 HEATING DELTA T 34 .0 COOLING DELTA T 17 .5 NOTE : *** Calculated Airflow is based upon load requirements . Verify that airflow calculated is compatible with selected equipment requirements . *** NFr