HomeMy WebLinkAbout16 Foxglove Lane FINAL CTI��O�S: z
E-wilding APPLICATION FOR BUILDING PERMIT
- ,
Plumbing '- '�
HVAC Date-
Sprinkler
3 92
Sprinkler 16 FOXGLOVE LANE
Electric �'' Estimated Cost $ 64,000.00
Zoning � 20009 Permit Fee$ 40.00
Affidavit o NO. Occupancy Fee $ -_00
Eng. Dept. _,r. t la-
COMPLETE RED BOXED AREAS.
Fire Dept. TYPE OR PRINT ONLY Total Fee $ 643.00
Health Dept. SIGN ON REVERSE SIDE.
Approved for CO: fZ U (Additional Cost) $
TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT
The undersigned, hereby applies to do work according to the following specifications:
Job Location. 16 Foxglove Lane Lot No. _Side of Street R Zone DR7
Applicant Rrom Bui I d rc -Ina. Tel. # 889-7106
Address 21`1_7 West- TnLum St, Nc,rwl oh Zip 06360 Lic.# 500339
STREET CITY ST
Owner rreza Builders. Address Same
Architect A. W. Mastronunzio Address 36 Pleasant View,_ le100-tt o}ty, rat 0635r
Size New Area: Ft. Front Overall 44' Ft. Deep Overall 271 Total Area 1,400 sf #Garages 1
Size of Lot Q Lavatories
_.�ga f Dist. from Street Line 30� _Bathrooms-2—Rooms 1st 4 2nd2-3rd
Purpose of this Permit Const-m-t a 3 hedrmm single family walling
City Water lx Well 0 Septic 0 Sewer
Use Group _
``� Construction Type �J
�1 1- L
Approved by Date f BD1A 11/88
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinanc s of th Town of South Windsor
and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree
that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is
located in a zone in which this building and its use is allowed.
Signed
—
I hereby apply for a Certificate of Occupancy for the work described in this application for permit.
Signed
—DO Nor WRITE BELOW THIS LINE—
fd �- �,? _9'a ,/ INSPECTION RECORD ramin
Footing C u�91 '71 1 �.q� ^ ✓~
2 v
Foundation 2�' �� a"— F ireplace/Chimney Insulation
Plumbing hermit# qeq 59 Inspections:
0,ou`ft. -711
F VAC Permit# q/,Z 0a Inspections:
{Cou�N 1 .1�� Z- CMG
Electrical Permit# �� 1 Inspections:
ROO6t4 71 16
Sprinkler Permit# Inspections:
Y
Location of job 1�j �—p)C �o�e e AFFIDAVIT Additional Fee ... -.. ..7......
State of Connecticut s.
ss.
County of Hartford
�/ T Owner
RaSA�h`!�'�''o...............of &144,.'c. Agent for building erected under
qA Contractor
Permit No. ............. issued by the Dept of Building of the'Ibwn of South Windsor being duly sworn,make oath
`�u Jeff
0 and say that the actual cost of the completed work authorized under said permit was.,G�4�(........ ......`{ `.../4A.. ....
-eSc7!`a4-e-ge cvdJ dL o U o 0
Signed ..G�.'!�� .... ........... . . .. .
I h
Subscribed and sworn to before me this .... ..........1..........day of ......... . ... . .......... .. .. .. A.D.19
rT fimate Cost:$ 1
DU Z ®�'
# I J . . .. ..
fference: 0 Notary Public _
Inspection / Approval Date By Appl
Code Description Due Whom Code Comment
-------------------------------------------------------------------------------
92-20009-B 64,000
B01 FOOTING 06/17/92 003 A
B02 FOUNDATION 06/22/92 003 A FOUNDATION COATING
B02 FOUNDATION 06/25/92 003 A FOOTING DRAINS
B03 FRAMING (ROUGH) 07/16/92 004 A
P03 ROUGH 07/16/92 004 A
H03 ROUGH 07/16/92 004 A
E03 ROUGH 07/16/92 004 A
B04 INSULATION 07/17/92 004 A
E01 SERVICE 07/21/92 004 A RELEASE ISSUED OK
B10 FINAL 08/26/92 003 A APPROVED FOR CO/CLOSEOUT
92-9058-P 2,500
92-8462-H 3,000
92-12270-E 2,400
Total Est Value 71,900
0
z
z
M
Inspection / Approval Date By Appl
Code Description Due Whom Code Comment
-------------------------------------------------------------------------------
92-20009-B 64,000
B01 FOOTING 06/17/92 003 A
B02 FOUNDATION 06/22/92 003 A FOUNDATION COATING
B02 FOUNDATION 06/25/92 003 A FOOTING DRAINS
B03 FRAMING (ROUGH) 07/16/92 004 A
P03 ROUGH 07/16/92 004 A
H03 ROUGH 07/16/92 004 A
E03 ROUGH 07/16/92 004 A
B04 INSULATION 07/17/92 004 A
E01 SERVICE 07/21/92 004 A RELEASE ISSUED OK
92-9058-P 2,500
92-8462-H 31000
92-12270-E 21400
ISCA-N
NE®
CERTIFICATE OF OCCUPANCY CHECK LIST
Applicant Brom Builders Certificate of Occupancy �0009 '
Address Bldg. Permit No. D
Lot No. 1 16 Foxglove Lane) Date Reviewed
Project PEACHBROOKE Reviewed By - Z
Date Submitted 9-15-92 Approved
9I `
As required in the Zoning Regulations, no Certificate-of-Occupancy shall be
issued until grading plans have been complied with and approved by the Town
Engineer. The minimum requirements shall include:
Approved Denied N/A
1 . Approved building permit plan.
2 . Finish grading per approved
building permit plan.
3 . Site work; i.e. trees, shrubs,
dumpsters, required parking.
4 . Utility location
a. Sanitary sewer
' b. foundation drain
c. electrical & telephone
d. water
e. other
y 5 . Sewer connection charge paid.
6 . Appropriate certification
7 . Bonding
8 . Planning & Zoning
Sewer Permit No. 59
Pavement Excavation No. 41W
COMMENTS:
SC A N w
BUILDING PER11IT CHECK LIST -
Applicant R_gu;i rje-s... T14c. Building Permit No.
Address 207 Wes Town St_ 06 mnrwl,f-h,*. CrPate Submitted ( • M. )
Lot No. I(; fig i nvP r,a„P Reviewed by
Project peachl-hrnnk Suhdi yi si nn Date -Addy
4'V I/•Of
In accordance with the Subdivision Regulations, prior to the building of
any structure on a lot, a Topographic Plot Plan shall be submitted for
approval. The minimum requirements shall include : 10
Approved Denied N/A
1. Name, address & phone number of owner/
/ applicant.
2. Name, address & phone number of plan preparer.
3. Zoning information - i.e. zone, open space,
floodway, etc.
4. Plot plan at 1" = 40' scale.
✓ a. Subdivision reference, abutting
5 properties, etc.
SfoG. .440W&-+> 4q. Easements of record.
c. Lot description, bearings, distances,
building lines, area, etc.
d. Contours, existing & proposed, 1 or 2 f t.
interval where appropriate.
e. Building location with dimensions.
Elevations of proposed finish floor,
garage floor & center line of road at
driveway.
f. Elevations of gravity drainage systems,
sanitary & foundation drain at the
house and the street.
g. Tentative utility location gas, electric,
water, etc.
h. Title block with name and address of
preparer, date appropriate certification,
live seal and signature.
5. Sedimentation and erosion control.
6. Special Planning & Zoning, Inland/Wetlands
considerations. (Plans on file w/Town Clerk)
BUILDING DEPT. mot, t� V jk+#j 91voit baeJ
PZC
IWA/CC
WPCA s p
OTHERS Ij E 6 c- 9
t? JUIV;�! 10
COMMENTS: Town O Tt",o
Enry.r (�indsnr
�f �`•►��rin� 1
\r 1,
4ZI.ANNED
PERMI
DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT
Application is hereby: TOWN OF SOUTH WINDSOR
BUILDING INSPECTION DEPT.
APPROVE DISAPPROVED 1540 SULLIVAN AVENUE
�/OC 644-2511 Ext. 230
Da a Building Inspector Application must be printed or typed
1 . LOCATION OF JOB
/" �x�'
FEE SCHEDULE No . Street
$ 0 - $19000 - $10.00 Floor Apt . No.
Over $1,000 $10.00
2 . OWNER
Per $1 .000 or
fraction thereof ?
3. ADDRESS CST du�,y Ag-
4. APPLICANT 4,06ez l/C �C
5. ADDRESS
®a
6. ESTIMATED COST $ -
7 . IS THIS A CONTRACT COST C/
� Y s o.
v
8. FEE ENCLOSED $ 3od
0
9. TYPE BUILDING:
z RESIDENTIAL COMMERCIAL
z
ion 10. TYPE F JOB:
0
Original Installation
Alteration/Addition/Repair
RD 3A 11/88
APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side)
11 . LOCATION OF JOB A51 / XCIZ0 UG`r- L
NO. STREET APT. NO ,
12 . TYPE OF INSTALLATION
13 . SIZE OF MAIN FEEDER �^�
14 . NO. OF LIGHT LOOPS 7` 15 . NO. OF HEAT LOOPS
16. NO. OF POWER LOOPS 17 . NO. OF LIGHT OUTLETS 10�2
18 . NO. OF HEAT CIRCUITS 19. NO. OF POWER OUTLETS ��
20. NO. OF CONVENIENCE OUTLETS �� 21. NO. OF HEAT CIRCUITS
22 . NO. OF POWER CIRCUITS 23. NO. OF LIGHT CIRCUITS
24. SIZE OF HEAT CIRCUITS 25 . NO. OF MOTORS
26 . NO. OF PANELS 27 . TOTAL WATTAGE
28. NO. OF POWER FEEDERS 29. NO. OF SWITCHES
30. A/C LOAD 31. SIZE OF POWER FEEDERS
32. NO. OF FIXTURES ` 33. TOTAL HORSEPOWER
34 . NAME OF SUBCONTRACTORS AND THEIR TRADES
35 . REMARKS AND FURTHER DETAILS :
LICENSE NO. SIGNATURE OF APPLICANT ATE
PHONE NUMBER:
M.
LjDt No.
Building Permit
Temporary Service
Permanent Servic6
Pursuant to Permit NO.
F? Certifies that the Electrical Work for which the above named PLarmit was granted Certifies duly Inspected and Is hereby approved.
`2 M Electrician'. -OLA9 1<1
LAN
Building Inspector
�j
PERMIT_.'
w
DEPARTMENT DECISION APPL I CAT I O N FOR
Application is hereby : PLUMBING PERMIT z
TOWM OF SOUTH WINDSOR
APPROVED DISAPPROVED BUILDING INSPECTION DEPT.
49L J44<—
644-2511 Ext. 230
ate Building Inspector Application must be printed or typed.
1. LOCATION OF JOB:
FEE SCHEDULE
2. OWNER:
3. ADDRESS: '
$ 0 - $19000 - $10.00
Over $1 ,000 - $10 .00
per $1 ,0 0 0 or 4. APPLICANT:
fraction thereof
I
5. ADDRESS:
6. EST. COST: $ L
7. IS THIS A CONTRACT COST? YES NO
8. FEE ENCLOSED: $ ' '
9. TYPE OF BUILDING:
RESIDENTIAL COMMERCIAL
10. TYPE OF JOB:
�GINAL ALTERATION
INSTALLATION ADDITION
REPAID.
BD 2A 11/88
APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side)
11. LOCATION OF JOB: (t 7��-'G����L� �l'1�I"
GENERAL PLUMBING
12. KIND OF INSTALLATION: 13. SIZE OF MAIN DRAIN
14. NO. OF TOILETS l STYLE 15. NO. OF URINALS STYLE
16. NO. OF BATHTUBS 16A. NO. OF SHOWERS 17. NO. OF LAVATORIES
18. NO. OF SINKS f 19. DISPOSAL l 19A. DISWASHER /
20. NO. OF CONDUCTORS_ -SIZE 3 21. NO. OF STACKS_ _SIZE
22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS
25. NO. OF OTHER FIXTURES KIND
26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW?
27. SIZE OF WINDOWiY f
28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE?
29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK? .. a✓�N
31. SIZE OF WATER MAIN 31A. SIZES OF WATER PIPING & RISERS
32. REMARKS AND FURTHER DETAILS
/ WATER HEATER
33. TYPE /A///( 34. MANUFACTURER
TANKS SAFETY DEVICES
TE11PERATURE
35. CAPACITY 39. RELIEF VALVE
36. TEST PRESSURE LBS. 40. MANUFACTURER
37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE
38. TYPE 42. MANUFACTURER
LICENSE NO. DATE SIGNATURE OF APPLICANT
PHONE NO.
rf
FOIr"(W . UH ONLY APPLICANT FQR HVAC ERMIT DATE: / Z
(N0. ) 'TOWN OF- SOUTH WIND R EST.EAST:
BLDG. PiIT NO, 1540 SLLI'VAN AVENPE FEE,
SOUTH WINDSOR, CT 06074 FEES:
644-�?.Sli - Ext. PO $ 0 - $19000 $I0.00
$1000 or fraction
LOCATION F BUI INO �� /!� thereof $IO.
60
wzl raiA. Z4V 22:u J'/�- i Mal
OWNER ADDRESS TOWN = PHONE NO.
HVAC CONTRACTOR ADDRESS TOWN PHONE NO.
TYPE OF SYSTEM: HEATING / TYPE OFBUILDING: RESIDENTIAL
A/C COMMERCIAL
VENTILATION BUSINESS
INDUSTRIAL
IF HEATING: STEAM JeW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.,
HYDRONIC WARM AIR
UNIT RADIANT HEATER (INCLUDING WOOD COAL BURNING STOVE)
TYPE OF FUEL: OIL-GPM � d GAS IN-PUT ELECTRIC KW
WOOD COAL / ,�
OIL TANK - SIZE & LOCATION INSIDE ✓-OUTSIDE CAPACITY 973
LPG TANK - CAPACITY
EXISTING RADIATION ADDITIONAL RAD TION TOTAL IATION�
DESIGN TEMP. OUTSIDE Q OF INSIDE G OF DIFFERENCE �°F
TOTAL HEAT LOSS (BTUH) 40 (HEAT LOSS SHEET MU CCOMP% APPL TION)
DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): —xoo Lti
GROSS HEATING CAPACITY (INPUT—BTUH) 3 NET RATING (OUTPUT—BTUH) Md—'A
IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN (BTUH)
(HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.):
TONNAGE COOLING CAPACITY (BTUH)
IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT):
TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM)
(PLAN MUST ACCOMPANY APPLICATION)
The undersigned hereby applies for a permit to perform the following work and is to comply
with all local ordinances and State of Conn. Building Codes in the performance of such work.
FURTHER DESCRIPTION OF WORK:
z S--i /`2-
STATE LICENSE - NAME & TYPE # DATE NATURE OF APPLICANT
APPROVED 6ATE
CANNE
BD 4A 11/88
I - B - R CALCULATION SHEET IN3 (Modem Method) Copyright 1977 by The Hydronlcs Inslltuto
OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE
COL.A COL.B COL.C COL.D COL.E COL.F COL.G
1 ROOM Q
O H L W H L W H L W H L W H L W Design Water Temp.
2 ROOM DIMENSIONS, FT.
_ U BTUH Pet F l of
3 LENGTH EXPOSED WALLS,FT. e( Radiation Selected
U.
4 WINDOW AND OUTSIDE DOOR AREA
STUN BTUH STUN BTUH STUN
WALL CONSTRUCTION
ROOM LIN. FT.OF
(Table 9, Lino 3 x H) TOTALS RADIATION
6 TYPE OF GLASS FROM LINE 12 SELECTED
5 D
(Bott m of table used f r Line 6)
7 CEILING CONSTRUCTION C
(Table 9. L x W)
_ - p
g FLOOR CONSTRUCTIONt
(Table 9, L x W r Lin. F t) E
9 COLD PARTITION CONSTRUCTION F
(Table 9, L x H)
G
10 1 Wall(With Openings) H
=o s;
r X
+ 2 Walls(With Openings) D
3 Walls(With Openings)or Ent.Hall I
—— J
11 TOTAL BTUH AT 70F TEMP DIFFERENCE'
12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE K
_^ COL.A — — COL.B COL.H COL. 1 COL.J COL. K COL.L TOTAL BTUH TOTAL
OF BUILDING RADIATION
1 ROOM ¢ AT SELECTED
O H L W H I L W H L W H L W H L W DESIGN TEMP.°
2 ROOM DIMENSIONS, FT DIFFERENCE
3 LENGTH EXPOSED WALLS, FT
4 WINDOW AND OUTSIDE DOOR AREA LL
BTUH BTUH BTUH STUN BTUH
5 WALL CONSTRUCTION •INCREASE BATHROOM
(Table 9, Llne 3 x H) TOTAL 20%
6 TYPE OF GLASS
(Bolt m of table used for Line 51
tFOR CONCRETE FLOOR ON
7 CEILING CONSTRUCTION
---- --
( GROUND OR FILL AT
Table 9, L x WI
GRADE LEVEL,USE LINEAR
S FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE
(Table 9, L x W r Lin Ft.)
9 COLD PARTITION CONSTRUCTION
(Table 9,L x H)
10 _G 1 Wall(With Openings) C
2 Walls(With Openings? D x
eJ
3 Wells(With Openings)or Ent.Hall F.
11 TOTAL BTUH AT 70F TEMP DIFFERENCE'
12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE
FORM 1503
This form is available from The Hydr nits Institute,36 Russ Place,Berkeley Heights,N J 07922
i
,.iqV I ROTEOH INC. ROB KV I LLE, OONN. 871-7802 Page 1
JOB NAME: THE DENNISPORT STREET DESIGN CONDITIONS TOTAL BLDG. HEAT LOSS/GAIN
PHONE TOWN CONNECTICUT ------------------------ -----------------------
BLDG : Heating: 80 deg f.t/d BLDG Heat Loss BTU 34,251
Estimator: NOTES: Cooling: 20 deg f.t/d BLDG A/C Gain BTU 23,607
Room 1 Room 2 Room 3 Room 4 Room 5 Room 6 Roos 7 Room 8 Room 9 Room 10 Room 11 Room 12
AREA NAME: BR 1 FAMILY KITCHEN DINING LAY BR 2 BR 3
Outside Wall Length: 24.5 27.0 22.5 12.0 22.0 33.0 38.0 0.0 0.0 0.0 0.0 0.0
Outside Wall Height! 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0
Sq/Ft S or W Glass 1 12.0 0.0 9.0 12.0 0.0 0.0 12.0 0.0 0.0 0.0 0.0 0.0
Sq/Ft N or E Glass 1 12.0 24.0 0.0 0.0 6.0 24.0 12.0 0.0 0.0 0.0 0.0 0.0
No of Doors 0.0 1.0 1.0 1.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Floor Width 11.5 14.0 10.0 10.0 13.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Floor Length 13.0 13.0 12.5 12.0 9.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Roof Width 11.5 14.0 10.0 10.0 6.0 14.0 13.0 0.0 0.0 0.0 0.0 0.0
Roof Length 6.0 7.0 6.0 6.0 9.0 12.0 12.0 0.0 0.0 0.0 0.0 0.0
-------------------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- --------
Area Cubic Feet 552 784 480 480 432 11344 11248 0 0 0 0 0
Gross Wall sq/ft 196 216 1BO 96 176 264 304 0 0 0 0 0
Net Wall sq/ft 172 171 150 63 170 240 280 0 0 0 0 0
Wall Heating BTU 963 958 840 353 952 11344 11568 0 0 0 0 0
Wall Cooling BTU 344 342 300 126 340 480 560 0 0 0 0 0
S/W Glass sq/ft 12 0 9 12 0 0 12 0 0 0 0 0
S/W Glass Heating BTU 595 0 446 595 0 0 595 0 0 0 0 0
S/W Glass Cooling BTU 149 0 112 149 0 0 149 0 0 0 0 0
S/W Glass Solar BTU 960 0 720 960 0 0 960 0 0 0 0 0
N/E Glass sq/ft 12 24 0 0 6 24 12 0 0 0 0 0
N/E Glass Heating BTU 595 11190 0 0 298 1,190 595 0 0 0 0 0
N/E Glass Cooling BTU 149 298 0 0 74 298 149 0 0 0 0 0
N/E Glass Solar BTU 480 960 0 0 240 960 480 0 0 0 0 0
Doors sq/ft 0 21 21 21 0 0 0 0 0 0 0 0
Door Heating BTU 0 538 538 538 0 0 0 0 0 0 0 0
Door Cooling BTU 0 168 168 168 0 0 0 0 0 0 0 0
Floor sq/ft 150 182 125 120 117 168 156 0 0 0 0 0
Floor Heating BTU 2,392 2,912 2,000 1,920 1,872 0 0 0 0 0 0 0
Floor Cooling BTU 0 0 0 0 0 0 0 0 0 0 0 0
Roof sq/ft 69 98 60 60 54 168 156 0 0 0 0 0
Roof Heating BTU 166 235 144 144 130 403 374 0 0 0 0 0
Roof Cooling BTU 69 98 60 60 54 168 156 0 0 0 0 0
Lights Cooling BTU 59 84 51 51 46 143 133 0 0 0 0 0
Appliance Cooling BTU 72 103 63 63 57 176 164 0 0 0 0 0
People Cooling BTU 132 161 111 106 103 149 138 0 0 0 0 0
Latent Cooling BTU 706 959 590 566 552 792 736 0 0 0 0 0
Ventilation Heat BTU 848 11050 714 639 585 529 564 0 0 0 0 0
Ventilation Cool BTU 562 553 391 405 264 570 652 0 0 0 0 0
Duct Heat Loss BTU 334 413 281 251 230 208 222 0 0 0 0 0
Duct Cool Loss BTU 221 217 154 159 104 224 257 0 0 0 0 0
--------------------- ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------
Area Heating BTU 51893 71296 41963 41440 41067 31674 31919 0 0 0 0 0
Area Cooling BTU 3,903 3,842 2,720 2,814 1,835 3,961 41533 0 0 0 0 0
Area Air Heating CFM 78 96 65 58 54 48 52 0 0 0 0 0
Area Air Cooling CFM 130 128 91 94 61 132 151 0 0 0 0 0
TTL Building. Square feet-) 1,018 Heating Air Changes/Hour -) 5.08
TTL Building. Cubic feet-> 51320 Cooling Air Changes/Hour -> 8.27
--------------------------- ------ -------- nmm . ----;; -----
TTL Building Heating CFM -> 451 Heating 9AT
TTL Building Cooling CFM -> 787 Cooling
06/10/1""Ji HEATING3/COOLING BTU ESTIMATE: