Loading...
HomeMy WebLinkAbout135 Graham Road INAL INSPECTIM:93 Building APPLICATION FOR BUILDING PERMIT Plumbing 3 y '"' � 3 Date: HVAC 135 GRAHAM ROAD Sprinkler- Electric 6 —9'3 Estimated Cost $ Zoning Permit Fee $ Affidavit 6n,'1'7 NO. 20284 Occupanc Fee 3 Eng. Dept. COMPLETE RED BOXED AREAS. Total Fee Fire Dept. TYPE OR PRINT ONLY $ Health Dept. SIGN ON REVERSE SIDE. v,-d Approved for (Additional Cost) $ TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The and rsigned, hereby applies to do work according to the following specifications: Job Location 1 S Lot No.—Side of Street Zone Applicant N-PLt� �-�4�( C1�NSi2G[�-7c1•�J lL Tel. # �o y�- 356ro Address /�j�U G LL I N 67yN 04oQ-7%t1 Lic.# STREET CITY STATE Owner � Address- Architect FkAWk, 7 A'SSoc' Address /ao� dd ' " #Garages Size New Area: Ft. Front Overall/� Ft;1eep Overall Total Area ges �' Q Lavatories No. of Familieso. of Stories Construction Bathrooms Ro s 1st 2nd 3rd Size of Lot //0 xc3" Dist. from Street Line 4('S Dist. from Side St et Line a5� Purpose of this Permit City Water Well 0 Septic Sewer -7c0� Approved by Oat4�22— BD1A 11/88 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor - and to notify th Building Inspector of any alt ration in the plans or specifications of th Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zone in which this building and its us is allowed. ' Signed I hereby apply for a Certificate of Occupancy for the work described in this application for permit �� Signed /`~- -DO NOR WRITE BELOW THIS LINE— INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation Plumbing Permit#__ Inspections: HVAC Permit# e�79 Inspections: Electrical Permit# / ' Inspections: Sprinkler Permit# Inspections: Location of job AFFIDAVIT Additional Fee $7.0 0..0 D......... State of Connecticut County of Hartford ss. I .Angela. M •Attene1.10............. ....a�laple Leaf C.Q�7. 0 r for building erected under on ractor Permit Na .2,Q.2 8 4................... issued by the Dep't of Building of the Town of South Windsor being duly sworn,make oath and say that the actual cost of the completed wont authorized under said permit did not exceed the most current accepted 6CCA "4 value of $1,2$.,o5o. .00. . . . . . . . . . . . . .k Signed .. ...................... f 0 _ Subscribed and sworn to before me this .1.7.t b.................day of .June....... ................A.D.19 9a.. Estimate Cost:$'5 9 . 0 0 0 . 0 0 Difference: s $f'9 ,0 5 0 .0 0 .... ....Notary Public....._.............. ., Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- 92-20284-B 51 ,000 BO1 FOOTING 10/20/92 003 A B02 FOUNDATION 10/26/92 005 A FOOTING DRAINS P03 ROUGH 11/13/92 005 A B03 FRAMING (ROUGH) 11/23/92 005 A E03 ROUGH 11/23/92 005 A P03 ROUGH 11/23/92 005 A B04 INSULATION 11/24/92 005 A B05 FIREPLACE/CHIMNEY 11/25/92 005 A B03 FRAMING (ROUGH) 05/05/93 JFH A UNFINNISHED AREA E03 ROUGH 05/05/93 JFH A UNFINNISHED AREA B10 FINAL 06/17/93 DDS A 92-9145-P 3,000 92-12418-E 2,000 92-8576-H 3,000 Total Est Value 59,000 Dwelling 2,700 100,386.00 Basement 943 9,382.85 Garage 283 3,325.25 Smoke Det 3 225.00 BOCA Value 50 8 Difference CERTiFiCATE OF OCCUPANCY CHECK LIST A� licant Maple Leaf Const. Co. Certificate of Occupancy `P ington Rd e , S.ja. Bldg. Permit No. Z�fZ Address Date Reviewed Lot No. 135 GraInam. Reviewed By Project West Way Subdiv. Da to Submitted 6-22-93 Approved/Denied • Regulations, no Certificate-of-Occupancy shall be As required in the Zoning gu issue d until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: ' Approved Denied N= 1 , Aocroved building permit plan. 2 . Finish grading per approved building permit plan. 3 , Site work; i .e. trees, shrubs , du:mpstens, required parking, a_ . utility location a. Sanitary sewer b, foundation drain c . electrical & tele✓ O:'.e d. water e. other 5 . Sewer connection charge paid• 6 . Accrooriate certifica`ion 7 . Bonding 8 . Planning & Zoning Sewer Permit No Pavement Excavation No. COMMENTS: C,AUED MAftC l eAF 6JtFF0 GkJ-ET "Alzl� Oc�ev S 1+ wS?,l C0vV' C'T '- 1 _ BUILDING PEPJ1IT CHECK LIST . & R 9 Applicant• and "r Aa f nn c +- • Builaing"Permit No. CJ M•�.e�.._r. t rLtir._z�n 2 a.m. ) 4 Address 175n Rilin S w_ Date Submitted Lot No. 2 *135 Graham Roads Reviewed by Project WPsi-Way S uh iyi Sinn Date Jp-IS qL ;TA� lD-/S-9 $r^�� In accordan ce with the Subdivision Regulations, prior to the bus o any structure on a lot, a Topographic plot Plan shall be submitted for approval. The minimum requirements shall include : Approved Denied N/A 1. Name, address & phone number of owner/ applicant. 2. Name, address & phone number of plan preparer. I PA -�A 3. Zoning information - i.e. zone, open space, floodway, etc. _ 4. Plot plan at 1" = 40 ' scale. a. Subdivision reference, abutting properties, etc. _ b. Easements of record. c. Lot description, bearings, distances, building lines, area, etc. d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate. e. Building location with dimensions. Elevations of proposed finish floor, garage floor & center line of road at driveway. f. Elevations of gravity drainage systems, sanitary & foundation drain at the house and the street. g. Tentative utility location gas, electric, water, etc. _ h. Title block with name and address of Predate appropriate certification, Parer, P pro P live seal and signature. S. Sedimentation and erosion control. C 6. Special Planning & Zoning, Inland/Wetlands considerations. (Plans on file w/Town Clerk) BUILDING DEPT. , l �C=1� P Z C IWA/CC 8 �Z WPCA r t V C i VEd OTHERS L T Town of IS 1992 ► So Euth Windsor COMMENTS: g n 1neering e� " PERMIT # DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is hereby: TOWN OF SOUTH WINDSOR BUILDING INSPECTION DEPT. APPROVED DISAPPROVED 1540 SULLIVAN AVENUE 644-2511 Ext. 230 11 I �- Date ng Inspector Application must be printed or typed 1. LOCATION OF JOB _ 5 (CA=b, 6.M FEE SCHEDULE No . Street i $ 0 - $19000 - $10.00 Floor Apt . No. Over $1,000 - $10.00 MQ4)C per $1 ,000 or 2 . OWNER fraction thereof . 3. ADDRESS )15L- Fflioo ��r? E)I DA rl� t4 -5G nds C 4. APPLICANT IC«� 5. ADDRESS a90 PIC, Rd, fLo+h LO I r�b()K , C T 6. ESTIMATED COST $ 7 . IS THIS A CONTRACT COST Yes No 8. FEE ENCLOSED $ V 9. TYPE OF BUILDING: RESIDENTIAL COMMERCIAL - 10. TYPE OF JOB: Original Installation Alteration/Addition/Repair BD 3A 11/88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11 . LOCATION OF JOB RG-C- NO. REET APT. NO , 12 . TYPE OF INSTALLATION 0\jechead 13. SIZE OF MAIN FEEDER 0/3 5.0,t 14 . NO. OF LIGHT LOOPS 15 . NO. OF HEAT LOOPS 16. NO. OF POWER LOOPS 17 . NO. OF LIGHT OUTLETS3 0 18 . NO. OF HEAT CIRCUITS 19. NO. OF POWER OUTLETS 20. NO. OF CONVENIENCE OUTLETS 21. NO. OF HEAT CIRCUITS 22 . NO. OF POWER CIRCUITS 23. NO. OF LIGHT CIRCUITS 24. SIZE OF HEAT CIRCUITS 25 . NO. OF MOTORS 26 . NO. OF PANELS / 27 . TOTAL WATTAGE 28. NO. OF POWER FEEDERS 29 . NO. OF SWITCHES 30. A/C LOAD 31. SIZE OF POWER FEEDERS 32. NO. OF FIXTURES_ 33. TOTAL HORSEPOWER 34 . NAME OF SUBCONTRACTORS AND THEIR TRADES Cj,!71 CO-AfCM10 35 . REMARKS AND FURTHER DETAILS : LICENSE NO. SIGNATURE OF APPLICANT DATE PHONE NUMBER: 6 yX /TZf.- b, Building Permit Temporary Service Permanent Service Pursuant to Permit No. 12 This Certifies that the Electrical Work for which the above named Permit was granted has been duly inspected and is hereby approved. Owner Electrician Street 11ding Inspector PERMIL.NO. 9�y5 DEPARTMENT DECISION APPLI CAT ION FOR Application is hereby : PLUMBING PERMIT TOWM OF SOUTH WINDSOR APPROVED DISAPPROVED BUILDING INSPECTION DEPT. `�/ P 644-2511 Ext. 230 D t Building Inspector Application must be printed or typed. 1. LOCATION OF JOB: 0/�14 �.o FEE SCHEDULE 2. OWNER: $ 0 - $19000 - $10.00 3. ADDRESS: Over $1, 000 - $10 .00 per $1 ,000 or 4. APPLICANT: fraction thereof 5. ADDRESS: 6. EST. COST: 7. IS THIS A CONTRACT COST? L000 YES NO 8. FEE ENCLOSED: $ •U d 9. TYPE OF B�IINGA�� RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: ;-RIGINAL ALTERATION INSTALLATION ADDITION REPAID. BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: �j�y ,yl ZZ GENERAL PLUMBING 12. KIND OF INSTALLATION: 13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS ._3 STYLE 15. NO. OF URINALS STYLE 16. NO. OF BATHTUBS 16A. NO. OF SHOWERS l 17. NO. OF LAVATORIES ..-4�3 18. NO. OF SINKS 19. DISPOSAL 19A. DISWASHER 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS_ _SIZE 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK? 31. SIZE OF WATER MAIN 31A. SIZES OF WATER PIPING & RISERS 3y Z 32. REMARKS AND FURTHER DETAILS �Z�l WATER HEATER 33. TYPE �i �G�SS �afG4 C FA�R C TANKS SAFETY DEVICES TEMPERATURE 35. CAPACITY 39. RELIEF VALVE 36. TEST PRESSURE LBS. 40. MANUFACTURER 37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE 38. TYPE 42. MANUFACTURER 49236 55 LICENSE NO. D4tE YGNATURE OF APPLICANT PH E NO. FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: /1'e, Z. (NO. ) TOWN OF SOUTH WINDSOR EST.0 T: ,tea BLDG. PERMIT NO. �tA �� 1540 SULLIVAN AVENUE FEE_ SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 $ 0 - $19000 - $10.00 $1000 or fraction LOCATION OF BUILDING /t�� �C.,D j thereof - $10.00 2C 7,11--,, OWNIER ADDRESS TOWN PHONE NO, H AC CONTRACTOR ObRESS TOWN PHONE NO. TYPE OF SYSTEM: HEATING �— TYPE OF BUILDING: RESIDENTIAL �- A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC w--" WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS (BTUH) (HEAT LOSS SHEET MUST ACCOMP APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): �/�il fGT yf-'r- /✓'7,/4C GROSS HEATING CAPACITY (INPUT-BTUH) /�s,o o NET RATING (OUTPUT-BTUH) ,6 6 a IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE F TOTAL HEAT GAIN (BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT): TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) (PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: AA Q s- STATE LICENSE - NAME & TYPE # IDATt SIGNATURE "OF APPL&PANT VED16ATIE BD 4A 11/88 I - 8 - R CALCULATION SHEET 1503 (Modern Method) Copyright 1977 by The Hydronics Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL.A COL.B COL.C COL.D COL.E COL.F COL.G 1 ROOM CC O H L W H L W H L W H L W H L I W Design Water Temp. 2 ROOM DIMENSIONS,FT. ~ _ U T aTUH per F t of 3 LENGTH EXPOSED WALLS,FT. Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA LL BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION (Table 9, Line 3 x H) Rol M LIN.FT.OF TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED (Bottom of table used for Line 5) 7 CEILING CONSTRUCTION C (Table 9, L x W) B FLOOR CONSTRUCTIONt (Table 9, L x W r Lin. F t) E 9 COLD PARTITION CONSTRUCTION F (Table 9, L x H) G 10 c 1 Wail(With Openings) =0 �; H i 2 Walls(With Openings) oX 3 Walls(With Openings)or Ent.Hall J 1 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' J 12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE K COL.A _ _ COL.B COL.H _ COL.1 COL.J COL. K COL.L TOTAL BTUH TOTAL OF BUILDING RADIATION 1 ROOM ¢ AT SELECTED O H L W H L W H L W H L I W H f L I W DESIGN TEMP.- 2 ROOM DIMENSIONS.FT F u -- DIFFERENCE _ - 3 LENGTH EXPOSED WALLS, FT. 4 WINDOW AND OUTSIDE DOOR AREA U. BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION *INCREASE BATHROOM (Table 9, Line 3 x H) TOTAL 20% 6 TYPE OF GLASS (Butt m of table used f r Line 5) 7 CEILING CONSTRUCTION — "- — tFOR CONCRETE FLOOR ON ( GROUND OR FILL AT Table 9, L x W) GRADE LEVEL,USE LINEAR B FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE (Table 9,L x W or Lin Ft 1 9 COLD PARTITION CONSTRUCTION (Table 9, L x H) 10 -G 1 Wall(With Openings) G _2 2 Wells(With Openings) D X 3 Walls(With Openings)or Ent.Hell J 11 TOTAL BTUH AT 70F TEMP DIFFERENCE* 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE ' This form Is available from The Hydr nits Institute,35 Russo Piece,Berkeley Heights,N.J 07922 FORM 1503 ' . - ragpe 1 *********************************************************�********************* ||EATLOSS vers 3. 1 Copyright 1986, 1987, Tho a mas and Assocites, Bellaire, Mi (616) 533-8472 �Y%.-Y.--or m.-x M. -K.-A. 4. _xl-XI.-9. .9- 1.M. M.���������������������������������������������������� PETER SAVAS � 56 CHRISTOPHER DR WESTFIELD, MA 01085 (41J) 562-69 86 11-16-1992 D & C. PLUMBIN� 139 GRAMHAM RD SOUTH W.I. -- ------------------'----------------- -------------------------------------' ENTRY Prepared by PETER SAVAS HE GS THE TOTAL BTUH FOR THIS ROOM IS 8, 2 The total feet required for this room 1�� 5 _....._.........___.......................... ............ __________________________________ _..............._ MASTER BATH & CLOSET Prepared by PETER SAVAG HEATLOSS - THE TOTAL BTUH FOR THIS ROOM lS 4, 632 The total feet of radiation required for this room 8. 0 ... .......-- -_____---- ---_........-... .....-.....' ........._ � �TEP BEDROOM Prepared by PETER SAVAS HEATLOSS TOTAL BTUH FOR THIS ROOM IS 8, 533 total feet of radiatioo r PE,quzred for this room 14. 7 _... ................._ _.....__..................� FAMILY ROOM Prppared by PETER SAVAS HEATLOSS THE TOTAL BTUH FOR THIS ROOM I 7, 016 The total feet of radiation required for this room 12. 1 _......... __________________________________________________ �.............. ...�.......................... .. ��������������������������������������� DINING ROOM/DINT ET[ F'repared by PETER SAVAC HEATLOSS THE TOTAL BTUH FOR THIS ROOM IS 8, 562 The total feet nf radiation required for this room 14. 8 ---------------------- ---... ...................-... ..............-.....--........-- ...... ---- ---------------------------- KITCHEN/BREAKFAST Prepared by PETER SAVA3 HEATLOSS THE TOTAL BTUX FOR THIS ROOM I 7, 479 The total feet ..-if radiation required [or this room 12. 9 _..........________________________________...... ____________ BEDROOM L[FT FRONT Prepared by PETER GAVAS HEATLOSS THE TOTAL BTUH FOR THIS ROOM IS 3, 992 The total feet of radiation required for this room 6. 9 __.........._...._.....______________________________________ _______________ RICHT FFONT OEDROOM Prepared by PET�R 3AVAC HEATLOSS THE TOTAL DTU}� FO� THIS ROOM IS 9, 390 . . Page 2 The total feet of radiation required for this room 16. 2 - ------------------------------------------'----------------------------------- BATH Prepared by PETER SAVAS HEATLOSS THE TOTAL BTUH FOR THIS ROOM IS 898 The total feet of radiation required for this room 1 . 5 REAR BEDROOM Prepared by PETER SAVAS !�EATLOSS THE TOTAL BT, FOR THIS ROOM IS 8, 560 The total feet of radiation required for this room 14. 8 ............ _ __________________________________________________________________________ TOTALS FOR LIVING AREA ' HEATLOSS THE TOTAL BTU} | FOR T| |I3 AREA IS 67, 474 The total feet of radiation required for this area 116. 3 End of report . . ' ' Pag� 1 ******************************************************************************* HEATLOSS vers 3. 1 Copyrzght 1986, 1987, Thomas and Associates, Bellaire, M1 (616/ 533-8472 ******************************************************************************* PETER SAVAS 56 CHRISTOPHER DR WESTFIELD, MA 01085 (413) 562-6986 11-16-1992 D & G PLUMBING 139 8RAMHAM RD SOUTH WINDSOR, CT ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDJNG (C) 1986, 1987 TA ENTRY Prepared by PETER SAVAS ROOM NUMBER 1 CEILING HEIGHT IS 16. 00 VOLUME IS 1920. 00 CUBIC FEET 2 EXPOSED70. 80 SQUARE FEET 1 EXPOSED WALLS, not zncluding openzngs, [OTALING >>> 121 . 20 SQUARE FEET ROOM SIZE IS 12. 00 LONS by 10. 00 WIDE, TOTALING >> 120. 00 SQUARE FEET FLOOR TYPE IS: Floor over any Conditioned Space CEILING TYPE IS: No Attic Space, part of Asphalt Shingled roof WINDOW TYPE IS: Single with storm sash WALL CONSTRUCTION IS: Frame, Insulated HEATLOSS The Total BTUH for the outside walls are 800 The Total BTUH for the Exposed Openings are 2, 627 The total BTUH for the ceilings 422 The total BTUH for the floors 0 The BTUH infiltration for the walls is. 0 The BTUH infiltration for the openings is 4, 562 THE TOTAL BTUH FOR THIS ROOM IS 8, 412 The total feet of radiation required for this room 14. 5 _...... .........._________________________________________________________________ ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA MASTER DATH & CLOSET Prepared by PETER S4VAS ROOM NUMBER 2 CEILING G H HE IS 8. 00 5 VOLUME IS 112. 00 CU8IC FEET 1 EXPOSED OPENINGS, [OTALING 18. 00 SQUARE FEET 2 EXPOSED WALLG, not including openings, TOTALIN6 >>> 174. 00 SQUARE FEET ROOM SIZE IS 12. 00 LONG by 12. 00 WIDE, TOTALING >> 144. 00 SQUARE FEET FLOO� TYPE IS: Floor over any Conditioned Space CEILING TYPE IS: Conditioned space above WINDOW TYPE IS: Single with storm sash WALL CONSTRUCTION IS: Frame, Insulated HEATLOSS The Total BTUH for the Outside walls are 1 , 148 The Total BTUH for the Exposed Openings are 887 The total BTUH for the cei1ings 0 The total BTUH for the floors 0 The BTUH infiltration for the walls is 0 The BTUH infiltration for the openings is 1 , 825 THE TOTAL BTUH FOR THIS ROOM IS 4, 632 The total feet of radiation required for this room 8. 0 ESTIMATED HEAT LOSS CA( .CULATION FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA . ' ^ ' Page 2 MASTER BEDROOM prepared by PETER SAVAS ROOM NUMBER 3 CEILING HEIGHT IS 12. 00 VOLUME IS 2016. 00 CUBIC FEET 2 EXPOSED OPENINGS, TOTALING >>>>>>>>>>>>>>>>>>>>>>>> 63. 00 SQUARE FEET 2 EXPOSED WALLS, not inc1uding openings, TOTALING >>> 249. 00 SQUARE FEET ROOM SIZE lS 14. 00 LONG by 12. 00 WIDE, TOTALING >) 168. 00 SQUARE FEET FLOOR TYPE IS: Floor over any Conditioned Space CEILING TYPE lS: No Attic Space, part of Asphalt Shingled roof WINDOW TYPE IS: Single with storm sash WALL CONSTRUCTION lS: Frame, Insul ate d HEATLOSS The Total BTUH for the outside wa1ls are 1 , 643 The Total BTUH for the Exposed Openings are 3, 105 The total BTUH for the cezlings 591 The total BTUH for the floors 0 The BTUH infiltration for the walls is 0 The BTUH infiltration for the openzngs is 3, 193 THE TOTAL BTUH FOR THIS ROOM IS 8, 533 7he total feet of radiation required for this room 14. 7 ESTI MA TED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA FAMILY ROOM Prepared by PETER SAVAS ROOM NUMBER 4 CEILING HEIGHT IS 16. 00 VOLUME lS 3136. 00 CUBIC FEET 2 EXPOSED OPENINGS, TOTALING >>>>>>>>>>>>>>>>>>>>>>>> 36. 00 SQUARE FEET 1 EXPOSED WALLS, not including openings, TOTALING >>> 188. 00 SQUARE FEET ROOM SIZE IS 14. 00 LONG by 14. 00 WlDE, TOTALING >> � 96. 00 SQUARE FEET FLOOR TY PE IS: Floor over any Conditioned Space CEILING TYPE IS: No Attic Space, part of Asphalt Shingled roof WINDOW TYPE IS: Single with storm sash WALL CONSTRUCTION IS, Frame, Insulated HEATLOSS The Total BTUH for the outside walls are 1 , 241 The Total BTUH for the Exposed Openings are 1 , 774 The total BTUH ror the ceilings 690 The total 8TUH for the floors 0 The BTUH infiltration for the walls is 0 The BTUH infiltration for the openings is 3, 312 THE TOTAL BTUH FOR THlS ROOM IS 7, 016 lhe total feet of r._-tdiation required for thzs room 12. 1 ESTIMATED HEAT LOSS CALCULATION FOR RESlDENTIAL BUILDJNG (C) 1986, 1987 TA ...........______________________..... ____________________________________________________ DININ6 ROOM/DINETTE Prepared by PETER SAVAS ROOM NUMBER 5 CEILING HEIGHT lS 8. 00 VOLUME IS 2016. 00 CUBIC FEET 2 EXPOSED OPENINGS, TOTALING >) >>>>>>>>>>>>>>>>>>>>>> 76. 80 SQUARE FEET 2 EXPOSED WALLS, not including openings, TOTALING >>> 187. 20 SQUARE FEET ROOM SIZ[ IS 21 . 00 LONG by 12. 00 WIDE, TOTALING >> 252. 00 SQUARE FEET FLOOR TYPE IS: Floor over any Conditioned Space CEILING TYPE IS: No Attic Space, part of Asphalt Shingled roof WINDOW TYPE IS: Single with storm sash WALL CONSTRUCTION IS: Frame, Insulated HEATLOSS The Total BTUH for the outside wa] ls are 1 , 236 The Total BTUH for the Exposed Openings are 3, 246 The total BTUH for the ceilings 887 The total BTUH for the floors 0 ' ` Page 3 The BTUH infiltration for the walls is 0 The BTUH infiltration for the upenzngs is 3, 193 THE TOTAL BTUH FOR THIS ROOM IS 8, 562 The total feet of radiation required for this ronm 14. 8 ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDlNG (C) 198691987 TA KITCHEN/BREAKFAST Prepared by PETER SAVAS ROOM NUMBER 6 CEILING HElGHT IS 8. 00 VOLUME IS 1848. 00 CUBIC FEET 1 EXPOSED OPENINGS, TOTALING ��>) >>>>>>>>��>>>>>>>>>'/>> 48. 00 SQUARE FEET 2 EXPOSED WALLS, not including openings, TOTALlN6 >) > 208. 00 SQUARE FEEl' ROOM SIZE IS 11 . 00 LONG by 21 . 00 WIDE, TOTALING >> 231 . 00 SQUARE FEET FLOOR TYPE IS: F'loor over any Conditioned Space CElLING !'YPE IS: No Attic Space, part of Asphalt Shingled roof WINDOW TYPE IS: Sing1e with storm sash WALL CONSTRUCTION IS: F'rame, Insulated HEATLOSS The Total BTUH for the outside walls are 1 , 373 The Total BTUH for the Exposed Openings are 2, 365 The total BTUH for the ceilings 813 The total DTUH for the floors 0 The BTUH infiltration for the walls is 0 The BTUH infiltration for the openings is 2, 927 THE TOTAL BTUH FOR THIS ROOM IS 7, 479 The total feet of radiation required for this room 12. 9 ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUTLDTNG (C» 1986, 1987 TA BEDROOM LEFT FRONT Prepared by PETER SAVAS ROOM NUMBER 7 CEILING HEIGHT IS 8. 00 VOLUME IS l056. 00 CU8IC FEET 1 EXPOSED OPENINGS, TOTALING >. >>>>>>>>>>>>> 15. 00 SQUARE FEET 2 EXPOGED WALLS, not including openings, TOTALING >>> 169. 00 SQUARE FEET ROOM SIZE IS 12. 00 LONG by 11 . 00 WIDE, TOTALING >> 132. 00 SQUARE FEET FLOOR lYPE IS: Floor over any Conditioned Space CEILING TYPE IS: No Attic Space, part of Asphalt Shingled roof WINDOW l'YPE IS: Single with storm sash WALL CONSTRUCTION IS: Frame, lnsulated HEATLOSS ` The Total BTUH for the outside wa11s are 1 , 1l5 The Total BTUH for the Exposed Openings are 739 The total BTUH for the ceilings 465 The total BTUH for the floors 0 The BTUH infiltration for the walls is 0 The BTUH znfiltration for the open1ngs is 1 , 673 THE TOTAL BTUH FOR THIS ROOM IS 3, 992 The total feet of radiation required for this room 6. 9 ESTIMATED HEAT LUSS CALCULATION FOR RESIDENTIAL BUILDIN6 (C) 1986, 1987 TA RICHT FRONT BEDROOM Prepared by PETER SAVAS ROOM NUMBER R CEILING HElGHT IS 8. 00 VOLUME IS 2016. 00 CUBIC FEET 1 EXPOSED OPENINGS, TOTALING >>>>>>>>>>>>>>>>>>>>>>>> 15. 00 SQUARE FEET 3 EXPOSED WALLS, not including openings, TOTALING >>> 417. 00 SQUARE FEET ROOM 3JZE IS �� . 00 LUNG by 12. 00 WIDE, TOTALING >> 252. 00 SQUARE FEET FLOOR TYPE IS: Floor over any Conditioned Space ' ' ' - ' Page 4 1--:EILIN8 TYPE IS: Unconditioned Attic Space Above WINDOW TYPE IS: Single with storm sash WALL CONSTRUCTION IS: Frame, Insulated HEATLOSS The Tota] BTUH for the outside walls are 2, 752 The Total BTUH for the Exposed Openings are 739 The total BTUH for the ceilings 1 , l09 The total BTUH for the floors 0 The BTUi-i infi l tration for the walls is 0 The BTUH infiltration for the openings is 4, 790 THE TOTAL BTUH FOR THIS ROOM IS 9, 39n The total feet of radiation requzred for this room 16. 2 �STIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA ........._____________________________________________________________________________ BATH Prepared by PETER SAVAS R U 8 ROOM NMER 9 CEILING HEIGHT IS O. 00 VOLUME IS 400. 00 CUBIC FEET 0 E XPOSED OPENlNGS, TOTALING >>>>>>>>>>>>>>>>>>>>>>>> 0. 00 SQUARE FEET 1 EXPOSED WALLS, not including openings, TOTALING >>> 80. 00 SQUARE FEET ROOM SIZE IS 1V. 00 LONG hy 5. 00 WIDE, TOTALING >> 50. 00 SQUARE FEET FLOOR TYPE IS: F'loor over any Conditioned Space CEILING TYPE lS: Unconditioned Attic Space Above WINDOW TYPE IS: No openings in this room WALL CONSTRUCTION IS: Frame, Insulated HEATLOGS The Total BTUH for the outside walls are 528 The Total BTUH for the Exposed Openings are 0 The total 8TUH for the ceilings 220 The total BTUH for the floors 0 The BTUH infiltration for the walls is 0 The BTUH infiltration for the openings is 0 THE TOTAL 8TUH FOR THIS ROOM IS 898 The tvI feet uf radiatim", requ] red [or this room 1 . 5 ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL DUILDING /C) 1986, 1987 TA ........_________________________________________________________________________ REAR BEDROOM Prepared by PETER SAVAS ROOM NUMBER 10 CEILING HEIGHT IS 8. 00 VOLUME IS 2496. 00 CUBIC FEET 2 EXPOSED OPENINGS, TOTALING >>>>>>>>>>>>>>>>>>>>>>>> 30. 00 SQUARE FEET 2 EXPOSED WALLS, not including openings, TOTALING >>> 266. 00 SQUARE FEET ROOM SIZE I LONG by 13. 00 WIDE, TOTALING >> 312. 00 SQUARE FEET FLUOR TYPE IS: Floor over an Conditioned Space CEILING TYPE IS: Unconditioned Attic Space Above WINDOW TYPE lS: Single with storm sash WALL CONSTRUCTION IS: FramR, lnsulated HEATLOSS The Total BTUH for the outside wal1s are 1 , 756 The Total BTUH for the Exposed Openings are 1 , 478 The total BTUH for the ceilings 1 , 373 The total BTUH for the floors 0 The BTUH infiltration for the walls is 0 The BTUH infiltration for the openings is 3, 954 THE TOTAL BTUH FOR THIS ROOM IS 8, 560 The tnt l feet of radiation required for this room 14. 8 - ' ^ - . Page 5 TOTALS FOR LIVING AREA VOLUME IS 18056 CUBIC FEET EXPOSED OPFNINGS, TOTALING >>>>>>>>>>>>>>>>>>>>>>>>v >v 373 SQUARE FEET EXPOSED WALLS, not includ11-Ig openings, TOTALING >>>>>> 2059 SQUARE FEET TOTAL SQUARE FOOTAGE OF HOME 1857 SQUARE FEET Prepared by PETER SAVAS HEATLOSS The Total BTUH for the Exposed Openings are 16, 961 The total BTUH for the ceilings 6, 570 The total BTUH for the f] oors 0 The BTUH infiltration for the walls is 0 The 8TUH infiltration for the openings is 299429 THE TOTAL BTUH FOR THIS AREA IS 67, 474 The total feet of radiation required for this area 116. 3 End of report Bectric# APPLICATION FOR BUILDING PERMIT Plumbing# 135 GRAHAM ROAD D°t 5Z3 z � / WAC # Sprinkler# �• 2 6 0 6 5 FINAL APPROVALS Estimated Cost 0 == Building I 1s,19g COMPLETE RED BOXED AREAS Permit Fee $ Engineering TYPE OR PRINT ONLY Occupancy Fee Affidavit 11 SIGN ON REVERSE SIDE ppr A .for CO. c- -► sVQ-) Total Fee TO BU ILDM DEPARTM NT,TOWN OF SOUTH WDDSOR,CT (Additional Cosh The undersigned hereby applies to do work according to the following specifications: Jo6 Location Lot No. Side of Street Zone Applicant iA Y0 5 Tel# i'o Y T 3 30 6 Address 1 GR-A 4 A wt tZ Zip Lic.# Owner ( ",& SC i4yk-)S Address Z 35' CAMO/u R Q Architect Address Sq.Ft.N w Area: 1st FL 2nd Fl. 3rd Fl. Total New Area #Rooms #Lavatories #Bathrooms #Garages Purpose of this permit: 4 01 vN Cty Water, Well ❑ Septic System 0 Sewer4 Ins. H.O. P. Cert. Area Basement Garage Approved 6y Date E 3 50 Use Group Construction Type �77 R•vs.d 1197 11111MINNIMINEMINNO I hereby agree to conform to all th requirem nts of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in wh' is building a is allowed. Signed I hereby apply for a Certificate of Occupancy for the scribed in this application for the permit. Signed &t2 - DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- 99-26065-B 4 ,300 E02 UNDERGROUND 06/18/99 RAN A B10 FINAL 07/15/99 DCJ A APPROVED FOR CO & CLOSEOUT 99-16235-E 500 i DEPARTMENT DECISION RNffr# APPLICATION FOR ELECTRICAL PERMIT � , ° Application is hereby: TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Permit 1540 SULLIVAN AVENUE APPROVE 644-2511 ext.230 Date 4� ding Inspector Application must be printed or typed tl'l Location of job �� -�. /�� Street No. Street Lot No. FEE SCHEDULE Floor Apt.No. t $0 - $1,000 - $12.00 1 Floor so- Over $1,900 F — $12.00 per$1,000 OWNER 9)"A/ or F any fraction thereof ADDRESS Z,3 OWNERS PHONE# 6 ,4 APPLICANT 0* N F ADDRESS ...... ESTIMATED COST$ jA 00 IS THIS A CONTRACT COST? YES NO FEE ENCLOSED $ Do �SpR. E OF JOB: Original Installation Alteration/Addition Repair Revised 11/95 APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A RESIDENTIAL BUILDING PERMIT APPLICATION YES / NO BUSINESS ASSEMBLY CURRENT USE AND OCCUPANCY MERCANTILE EDUCATIONAL FUTURE USE AND OCCUPANCY INSTITUTIONAL FACTORY STORAGE ENGINEER'S NAME PHONE GARAGE MIXED USE ADDRESS CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF MAIN FEEDERS AND RATING OF WIRE USED NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED 7 YES/NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPERATE BEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK 2 /' 4 ®0 THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH WORK NAME STATE LICENSE NO. TYPE StdNATURE O PLICANT PHONE NO.�i�� 3 3 0 DATE