Loading...
HomeMy WebLinkAbout155 Lisa Drive (2) of the APPLICA TION FOR TOWN OF SOUTH WDOSOR,COKNL PLAN EXAMINATION AND BUILDING PERMIT IMPORTANT — Applicant to complete all items in sections: 1, 11, Ill, IV, and IX. p I• AT (LOCATION) /-1 Z&z:` � ZONING • LOCATION ("�•) aTR�T) DISTRICT A—3 0 OF BETWEEN AND BUILDING (CROSS STREET) (CROSS STREET)I x �Cp SUBDIVISION MOUNTAINVIEW ESTATES LOT BLOCK LOT 6 .q106,'70 X II. TYPE AND COST OF BUILDING — All applicants complete Parts A —'DGO A. TYPE OF IMPROVEMENT 70 D. PROPOSED USE For"Wrecking"most recent use f11 1 ETN w building rnReside teal N � onresidential 2❑ Additi n(l/residential, enter nwnber 12 One family 18❑ Amusement,recreational of new bousing units added, i/any, in Part D. t 3) 13❑ Two or more family — Enter 19❑ Church, other religi us 3❑ Alterati n (See 2 above) number o/units————--'P'-_ 20❑ Industrial 4 Repair, replacement 14 ❑ Transient hotel, motel, 21 ❑ Parking garage 5❑❑ or dormitory — Enter number Wrecking 0/multifamily residential, of units ----_-- —--sp 22❑ Service station, repair garage enter number of units to building in 15❑ Garage 23❑ Hospital, institutional Part D, 13) 6❑ Moving (relocation) 16❑ Carport 24❑ Office, bank, professional t7 E] Other — Specify 25 Public utility 7 ❑ Foundation only 26❑ School, library, other educational B. OWNERSHIP 27❑ Stores, mercantile r 8 Private (individual, corporation, 28 ❑ Tanks, towers n nprofit Institution, etc.) 29❑ Other — Specify 9 ❑ Public(Federal, State, of 1 cal government) C. COST (Omit cents) Nonresidential — Describe in detail proposed use of buildings,e.g.,f ad processing plant, machine shop, foundry building at hospital, elementary 10. Cost of improvement................ O school, secondary school, college, parochial school, parking garage lot. To be installed but not included deportment store, rental office building, office building of Industrial plant. in the above cost If use of existing building Is being changed, enter proposed use. a. Electrical...................... b. Plumbing c.Heating, air conditioning......... J.Other(elevator, etc.)............ 11. TOTAL COST OF IMPROVEMENT III. SELECTED CHARACTERISTICS OF WILDING — For new buildings and additions, complete Parts E — L; for wrecking, complete only Part J, for all others skip to IV. E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS 30❑Me* my(wall bearing) 40 0 Public or private company 48• Number of stories. 31 ,( W ad from@ 41 ❑ Private (septic tank,etc.) 49. Total square feet of floor area, 32❑ Structural steel all floors, based on exterior O ..................... 33 CD Reinforcedconcrete H. TYPE OF WATER SUPPLY dimenalons P C/ 34❑ Other — Specify 42�Publie or private company 50• Total lend area, sq. it............ 43❑ Private(well, cistern) K. NUMBER OF OFF-STREET PARKING SPACES F. PRINCIPAL TYPE OF HEATING FUEL I. TYPE OF MECHANICAL 51. Enclosed ....................... 35 Gas Will there be central air 52. Outdoors..•........••........... W ❑ Oil conditioning? 37❑ Electricity 44❑ Yes 45 N� L. RESIDENTIAL BUILDINGS ONLY 30 ❑ C at 53. Number 16 drooms.............. 39❑ Other— Specify Will there be on elevator? ('� 54. Number of Full.......... 4ro 46❑ Yes 47 N bathrooms .j v f Partial...... IV. IDENTIFICATION — To b completed by all applicants Nam Meiling eddr ss — Number, street, city, and State ZIP cod Tel. N , Dart Fill Realty Inc . 658 E11 ' Owner or Lessee South Windsor . 2. Same Contractor 3. Architect or Engineer Th owner of this building and the undersigned agree to conform to all applicable laws of this jurisdiction. Signoture of applicant Address Application dote ` , Z0 0 - /9 7, DO NOT WRITE BELOW THIS Llnt V. PLAN REVIEW RECORD — For office use Plan Review Date Plans Dote Plans Plans Revi w Required Check Fee Started By Approved By Notes BUILDING $ PLUMBING $ MECHANICAL $ ELECTRICAL $ OTHER $ VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS Permit or Approval Check obtained Date Number By Permit or Approval Check ObDtained Plumber By BOILER PLUMBING CURB OR SIDEWALK CUT ROOFING ELEVATOR SE ER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OIL BURNER WRECKING OTHER OTHER VII. VALIDATION Building / Permit number Bui(ding P rmit issu d 19 Building E��r OD . P rmit Fee $ C LO' 3C 00 Ok V ` ��rL TOWN OF SOUTH WINDSOR BUILDING PERMIT Date-8P r i 1 14 , 19 87 Fee Paid $.4 a 2..0 0 Est. Value $. .7.2.,.0 0 0 Petit N° 15738 on the side of Lot #66 Lisa Dri Sueet Street No. 155 Owner Dart Hill Realty Inc . Applicant MLri_el jar-cluPs CERTIFICATE OF OCCUPANCY ISSUED: Date No. A??5 Fee Paid $ 3 .0 0 CLASSIFICATION Dwellincl BUIMNG PERMIT N 4 15738 OFFICE OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. Smith Windsor, Conn. Apr i 1 14 107 M#iz 'to to (gerttf-U, That Dart Hill Realty Inc. is hereby granted permission to Dwelling at estimated value of on the side of Lot #6 6 Lisa Drive Street on land owned by Dart Hill Realty Inc, Said Work to be as described in Applicatioa No. 16 0 3 8 and to conform to specifications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH WINDSOR. Issued April 14 1987 Building Inspector. Strata and sidewalks, obstructed by excavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: "When any person dull place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costs and damages which it shall sustain, or be compelled to reason therefor." Dwelling - Lot #66 Mtn.Vw.3 4/14/87 Dart Hill Realty Inc. 155 Lisa Drive Permit # 15738 Electrician #11-10 Heating Contr. h=1Y"Y ) R 0-T't CP # Plumbing S. Windsor Htg and Plg #7347 Oil Burner # Certificate of Occupancy #8125 Sewer Permit y✓�7l&7 Plot plan apprd. per Engr. INSPECTION EPORT ?� Permit # "/ Job 1 Footing 2 Foundation 3 Framing 4 Wiring 5 Plumbing 7347 . Elm w 6 Heating �� ��' p 7 Lathing a C.O. S'/, 1 Permit No. TOWN OF SOUTH WINDSOR SOUTH WINDSOR, CONN. Permit 8125 Certificate of Occ9pancy THI$`LS TO CE IFY th e �=� �``t-- � at Noa-� + Er -s..�, c in the wn of South Windsor, Connecticut, has been erected and completed in accordance with the-f3uilding Code and Zoning Regulations of the Town of South Windsor, and is hereby approved 5' occupancy. --( t J �� Rdilduig Inspector r Owner, Builder Fee Paid Date - �,� _ �_ ,u 19 6 r BUILDING PERMIT CHECK LIST Applicant Building Permit No. Address Date Submitted y-oz-off Lot No. Reviewed by 11970�� Project 3 Date 4�-os- In accordance with the Subdivision Regulations , prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include : Approved Denied N/A G h,y g/3 1. Name, address & phone number of owner/ applicant. G 3 x s iis 2. Name, address & phone number of plan preparer. 1/ 3. Zoning information - i.e. zone pen spa , floodway, etc. 4 . Plot plan at 1" = 40 ' scale. a. Subdivision reference, abutting properties , etc. b. Easements of record. C. Lot description, bearings , distances , building lines , area, etc. d. Contours , existing & proposed, 1 or 2 ft. interval where appropriate. e. Building location with dimensions. Elevations of proposed finish floor, _ garage floor & center line of road at driveway. f. Elevations of gravity drainage systems, g Y g Y sanitary & foundation drain at the house and the street. g. Tentative utility location gas, electric , / water, etc . y h. Title block with name and address of preparer, date appropriate certification, live seal and signature. 5 . Sedimentation and erosion control . 6 . Special Planning & Zoning, Inland/Wetlands considerations . (Plans on file w/Town Clerk) BUILDING DEPT. PZC IWA/CC (� WPCA OTHERS COMMENTS : 9690 ELECTRICAL APPLICATION Application No. l 11:18 on the side of hot #!_6 Street Street No. Owner JMJ Construction Electrician Richard Barrett FILED IN OFFICE OF The Building Inspector May A 1981-- INSPECTION. r&No Electrical Work shall be started until a Per- mit is granted by the Building Inspector. In New Buildings no wiring shall be started until the plumbing and heating pipes, and the fire stops (if of wood) are installed, without a special permit from the office of the Building Inspector. Electrical Permit No. ..................................... Master License No. TOWN OF SOUTH WINDSOR Building Permit No. a0— ...... ........ BUILDING DEPARTMENT Date Filed .......If- .0......................... Date Final Approval ......................................... APPLICATION FOR ELECTRICAL WORK Electrical Inspector OBLOCATION . .......... . . ............ . ........................... OB OWNER. ...... . . ... . ... . .............................................J J ea4 Side of W-4J'-V'\ ...... ...... Between ... ..... .............. ... and ...4............................... ............................. .0 C-I ................................... Name of Building Owner ....... Address .... ....... If work is for Lessee—Give name ... . ........ ........ ... Address .................................................................................................. Building now occupied as (unlss new) . . ........... No. of family units now ..... ......... ............ Building to be occupied as Number of family units to be ...... j................... Is this work include in a Building Permit? Lop Permit Fee ......... ........... ............................................................................................... (If �3 no "1 B Permit) • x— Permittee Business Address .—C.- Telephone ('04 ....... COSTOF INSTALLATION: . ............................... . .. .................................................................................................................................................. TO BE FILLED OUT BY PERMITTEE TO BE WIRED EXISTING APPLIANCES Number of light outlets to be installed Number of convenience outlets to be installed Number of present Appliance Circuits ...... ......................................... Number of switches to be installed Do these include Range ❑ Water Heater ❑ 4 Number of appliances to be installed L2.> - - - (as listed below) Dryer R Air Conditioner ❑ Oil Burner E] TYPE RATING NO. Range . . . . . . . . Dish Washer ❑ Gas Burner E] Well Pump E] Elec. Heaters ❑ Range Top . . . . . . Oven . . . . . . . . REMARKS: Water Heater Clothes Washer . . . . Clothes Dryer . . . . . Dish Washer . . . . . . Air Conditioning Motor . - Oil Burner Motor . . . . Gas Burner . . . . . . Circulator Motor . . . . Attic or Large Fan . . . Well Pump . . . . . . Electric Heat . . . . . Other . . . . . . . . .. Number of new Lighting Circuits Number of new Appliance Circuits . . . .......... Number of Heating Circuits ................. Number of Motor Circuits . . . . . . . ... Size of present service ............... . ................... Size of service to b-e ...........................'c'A 4j.C.-...P, 7347 PLUMBING APPLICATION App]� Nm 7 015 on the ......_......... aide of _.......L.tt' -O.�� dl s a=Dr y3� $Rt�eet Street No. Owner ......Dart-Hil Realty p(t S.. Windsor Htg and Pla Filed in Office of The Bukimg Lrpectiar _ June 16 19 87 • II�TSP�C�O1�T. No person shall coast=4 add to ac abet ay portion of the drainage system of any 6o&img (e:oept to repair leans) until a Be-nit is ymmd by the Buil ng Inq)eaw. APPLICATION FOR PLUMBING PERMIT (Continued from Reverse Side) TOWN OF SOUTH WIND OR, CONN. 11. LOCATION OF JOB Lot #66 Lisa Drive �/5--5' NO. STREET FLOOR APTAO. GENERAL PLUMBING 12. KIND OF INSTALLATION Residential 13. SIZE OF MAIN DRAIN 4 � 14. NO. OF TOILETS 3 STYLE tank 15. NO. OF URINALS 0 STYLE 16. NO.OF BATHTUBS 2 17.NO.OF LAVATORIES 3 18. NO.OF SINKS 1 19. NO. OF WASHTUBS 0 20. NO.OF CONDUCTORS SIZE 21. NO. OF STACKS 1 SIZE 3 22. AREA OF ROOF 23.NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES 1 KIND 4' shower stall_ 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? yeS 27. SIZE OF WINDOW 28. IF NO WINDOW,WHAT KIND OF VENTILATION IS THERE? electric vent fan 29. SIZE OF DUCTS 3 30. ARE SEWAGE AND WATER FACILITIES AVAILABLE? yes SIGNATURE ADDRESS 524 Burnham Street South Windsor O D, O 528-4413 LICENSE NO. 203068 ESTIMATED COST �S TELEPHONE OWNER t Realty. Inc. ADDRESS 658 Ellington Road South Windsor WATER HEATER 31. TYPE gas fired 32. MANUFACTURER A. O. Smith TANK - SAFETY DEVICES 33. CAPACITY gallons 37. TEMPERATURE RELIEF VALVE o�/D 34. TEST PRESSURE O A .f 38. MANUFACTURER_ OJI1 JTS 35. WORKING PRESSURE aU/�S f 39. PRESSURE RELIEF VALVE 36. TYPE /a'�r J! ��AG L 40. MANUFACTURER 1 ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE OWNER OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. CD962 D#rf E SI AT E APPL T PERMIT # i Apphcat on For DEPARTMENT DECISION - 4 FA Heating Permit O 3 APPLICATION IS HERESY: DEPARTMENT OF LICENSES AND INSPECTIONS ❑ APPROVED ❑ DISAPPROVED a TOWN OF SOUTH WINDSOR 0 o � �i OAT[ CHIEF INSPECTOR APPLICATIONS MAST R[ PRINTED Ow TTrto. SEGIN,MITM NUMBER ONE •[LOB O 1. LOCATION Of JOB 1-65- �- NO. STREET LOT NO. FLOOR A". NO. 4 0 OWNER � 15 �cTu�STrtl�/C,T70YV � :. O s. ADDRESS 6 S� &� AJ&b7'1.) S�. (��'y S �--� .PHONE lob Go 'C •. APPLICANT .0 a s. ADDRESS 7.PHONEP7(- G. LICENSE NO. 3070F7 a f. EXPIRATION DATE Of LICENSE IOZ,'07 ,g 10. ESTIMATED COST S o0 0 N *� 11. 18 THIS A CONTRACT COSTI YES ❑ NO be a 7 � 1!. fEE ENCLOSED S A94 d 1s. TYPE Off-OW-DING.- yr� �J NEs10ENTML ❑ COMMERCIAL O R A y 14. TYPE f JOB: INDUSTRIAL cc •��+ ORNi1M11< ALTERATI N INSTALLATION ❑ ADDITION REPAIR APPLICATION FOR HEATING PERMIT (Continued from Reverse Side) 11. L CATION OF JOB 107-*6& 0z15rq� 7) 12 NO. STRUT FLOOR A".N . 11. TYPE OF INSTALLATION: ❑ OIL BURNER ❑ ELECTRIC ❑ VENTILATI N ❑ SPRINKLER GAS BURNER ❑ STACK ❑ INCINERATOR ❑ MISCELLANEOUS Sys-?W- J3ronf IptNTIFT SIZE LOCATION SIZE SIZE 13. OF TANK OF TANK OF FILL OF VENT 14. B.T.U. EQUIP. AT REGISTER "760 FURNACE MAKE AND NO.C6V'f0?C AT BONNET'3b.dC)a FIRING RATE BOILER OR FURNACE MAKE AND NO. B.T.U. OR SQ. FT. NET B.T.U. OR SO. FT. GROSS FIRING RATE FLOORS TO BE HEATED NEW OR OLD BUILDING INSULATED - YES OR NO TYPE OF WALL INSULATION ROOF OR CEILING INSULATION AVG. SYSTEM WATER TEMP. B.T.U./SQ. 7WHR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE $G Z V 0 FAHRENHEIT MAKE OF RADIATION: BASEBOARD. COPPER CONVECTORS. OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ. FT. OR B.T.U. DESCWFTION OF WORK 2n,S7 �17UYi/ o� �j.,¢r�� �,A./� ��ji���� �g 3 TOE/ 15. TO BE DONE• Gv/Tsz,0' I 16. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS): ROOM i1Ze WINDOW@ AREA - SQUARE FEET SI.T.LL •.T.0 G DISTRIBUTION INSTALLED AMC DOORS VOLIAi TOTAL TOTAL < ROOM ND' GROSS CLASS NUT MALL CEILING FLOOR CU.PT. AT we F CORRUCTUD J j� R90ISTUR L W N AND c TEMP. TO I.: TVPff AND SIZE RAD. R LEADER SIZe < WALL .'LTC IINFILT.) DIFF. •F M iQ. FT. RRUU AREA TOTALS A. HEAT LOSS FROM BUILDING ` �` �T 3OZ' B.T.U./HR. B. DOMESTIC HOT WATER DEMAND B.T.U./HR. C. PIPING. OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY: NAML AOpRtlii SUBCONTRACTORS AND 1s. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OW R (AGENT) OF THIS ROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. APPLICATION TO BE COMPLETELY FILLED IN e Daftfi 03-May-87 HEATING / COOLING BTU LOSS ESTIMATE 101 NAME a JMJ CONST Street IL07*-&4e 1-1y4 DESIGN CONDITIONS S0. WINDSOR CONNECTICUT. ------------------........ iZ Roost Phone HeAtingi 90 dog fit/d ESTIMATORi OS 81d9c CONTEMP Coolings 20 dog f.t/d Roos 1 Room 2 Room 3 Room 4 Room 5 Roos 6 Room 7 Room 8 Room 9 Room 10 Room 11 Room 12 Room 13 AREA NAME FAN/RM KITCH DIN/RM LAUND DEN FOYER LIV/RM MAST/BR BATH/3 BATH/2 B/R 2 B/R 3 Outside Wall Length 34.4 10.0 24.0 6.0 24.0 15.0 35.4 25.4 16.0 9.8 11.0 25.0 0.0 Outside Wall Height 8.0 8.0 8.0 8.0 9.0 8.0 9.0 8.0 8.0 8.0 8.0 8.0 8.0 Sq/Ft S or W Glass 0.0 0.0 0.0 0.0 16.0 0.0 32.0 0.0 0.0 0.0 0.0 0.0 0.0 Sq/Ft N or E Glass 58.0 6.0 16.0 0.0 0.0 14.0 0.0 16.0 0.0 0.0 16.0 16.0 0.0 No of Doors 0.0 0.0 0.0 1.0 0.0 1.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Floor Width 21.0 10.0 10.9 6.0 12.0 7.0 21.0 0.0 0.0 0.0 0.0 0.0 0.0 Floor Length 13.4 13.4 13.4 6.0 12.0 8.0 14.4 0.0 0.0 0.0 0.0 0.0 0.0 Roof Width 0.0 0.0 0.0 0.0 12.0 7.0 21.0 12.0 9.8 9.8 11.0 13.0 0.0 Roof Length 0.0 0.0 0.0 0.0 14.0 8.0 16.0 13.4 6.8 6.8 10.0 12.0 0.0 -------------------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- Area Cubic Feet 21251 11072 1,168 288 11512 449 3,024 11286 533 533 880 11248 0 Gross Wall sq/ft 275 80 192 48 216 120 319 203 128 78 88 200 0 Net Wall sq/ft 217 74 176 27 200 85 287 187 128 78 72 184 0 Wall Heating BTU 11216 414 986 151 1,120 476 1,605 1,048 717 439 403 1,030 0 Wall Cooling BTU 434 14B 352 54 400 170 573 374 256 157 144 368 0 S/W Glass sq/ft 0 0 0 0 16 0 32 0 0 0 0 0 0 S/W Glass Heating BTU 0 0 0 0 794 0 11587 0 0 0 0 0 0 S/W Glass Cooling BTU 0 0 0 0 19B 0 397 0 0 0 0 0 0 S/W Glass Solar BTU 0 0 0 0 11200 0 2,560 0 0 0 0 0 0 N/E Glass sq/ft 58 6 16 0 0 14 0 16 0 0 16 16 0 N/E Glass Heating BTU 2,877 29B 794 0 0 694 0 794 0 0 794 794 0 N/E Glass Cooling BTU 719 74 198 Q 0 174 0 198 0 0 198 198 0 N/E Glass Solar BTU 2,320 240 640 0 0 560 0 640 0 0 640 640 0 Doors sq/ft 0 0 0 21 0 21 0 0 0 0 0 0 0 Door Heating BTU 0 0 0 538 0 538 0 0 0 0 0 0 0 Door Cooling BTU 0 0 0 168 0 ISO 0 0 0 0 0 0 0 Floor sq/ft 282 134 146 36 144 56 302 161 67 67 110 156 0 Floor Heating BTU 41502 2,144 21337 576 21304 896 41838 0 0 0 0 0 0 Floor Cooling BTU 0 0 0 0 0 0 0 0 0 0 0 0 0 Roof sq/ft 281 134 146 36 168 56 336 161 67 67 110 156 0 Roof Heating BTU 0 0 0 0 403 134 806 386 160 160 264 374 0 Roof Cooling BTU 0 0 0 0 168 56 336 161 67 67 110 156 0 Lights Cooling BTU 240 114 125 31 143 48 287 137 57 57 94 133 0 Appliance Cooling BTU 295 141 153 38 176 59 353 169 70 70 116 164 0 People Cooling BTU 153 73 79 20 78 30 164 87 36 36 60 85 0 Latent Cooling BTU 814 387 422 104 416 162 874 465 193 193 318 451 0 Ventilation Heat BTU 11547 514 741 228 032 493 11591 401 158 108 263 396 0 Ventilation Cool BTU 896 212 355 75 515 257 998 402 122 104 302 395 0 Duct Heat Loss BTU 609 202 291 90 327 194 626 158 62 42 103 156 0 Duct Cool Loss BTU 352 83 139 29 203 101 393 158 48 41 119 155 0 --------------------- ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ Area Heating BTU 10,751 3,572 51148 11582 51780 31425 11,053 21787 11097 749 1,827 21750 0 Area Cooling BTU 61224 11473 29464 518 3,578 11784 61934 21791 948 724 21101 2,745 0 Area Air Heating CFM 141 47 68 21 76 45 145 37 14 10 24 36 0 Area Air Cooling CFM 207 49 B2 17 119 59 231 93 28 24 70 92 0 Heating BTU's per CFM 76 Cooling BTU's per CFM 30 TTL Number of People > 4 TTL Bldg. Square feet > 1,660 TTL Bldg. Cubic feet > 14,244 --------------------- ------ --------------------- ------ --------------------- ------ --------------------- ------ 06 Heat Loss BTU's 50,522 TTL Bldg. Heating CFM > 665 Bldg. Heat BTU/Sq-Ft > 30 Bldg. Heat BTU/Cu-Ft > 3.55 -ALDG Cool Loss BTU's 32,185 TTL Bldg. Cooling CFM > 1,073 Bldg. Cool BTU/Sq-Ft > 19 Bldg. Cool BTU/Cu-Ft > 2.26 ENVIRO TECH. HVAC CO NTRACTINS FINAL INSPECTION s `Buildin�`' APPLICATION FOR BUILDING PERMIT Plumbing HVAC Date: C V-/ M- -I Sprinkler 00, 155 LISA DRIVE Electri�ts-3��� mod,�- Estimated Cost $ c) Zoning Permit Fee$ !� Affidavit NO, 17 6 6 6 Occupancy Fee $ Eng. Dept. COMPLETE RED BOXED AREAS. Total Fee $ Fire Dept. TYPE OR PRINT ONLY Health Dept. SIGN ON REVERSE SIDE. Approved for CO: (Additional Cost) $ TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications:L'i 5t .5-2 Cb Job Location 's - Lot No. Side of Street Zone Applicant Tel. # 97.2--/9,7, Address !/�j e_Z0?d rt Zip Li # S0 3 </'o -� STR T CITY STATE , Owner 7 T o E ddress o u d S' Architect Address Size New Area: Ft. Front Overall Ft. Deep Overall Total Area #Garages Lavatories No. of Families No. of Stories Construction Bathrooms Rooms 1st 2nd 3rd i Size of Lot Dist. from Street Line is/t. from Sidi reet Line /0117 Purpose of this Permit �� S `? K City Water Well ❑ Septic Sewer Approved by Date BD1A 11/88 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,sid yard lines nd required distanc from all other zones and is located in a zone in which this building and its use is allowed. Signe I hereby apply for a Certificate of Occupancy for the work described in this applic on r pe It. Signed —DO NOT WRITE BELOW THIS LINE— INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation Plumbing Permit# Inspections: HVAC Permit# Inspections: Electrical Pr;rmit# Inspections �- Sprinkler Permit# Inspections: # 68 LOT --� . LOT # 64 13011 E I.P.(Fhd) Y . N ply 51' _ � t i '1.01.1�1 I.P.(Fhj) t i I t 1 Z8t i aco PROPOSED 8 POOL 35 0) 5 LOT 65 k a 7' l I A i LOT u Z e, ideck I #66 'h 4 3' v J ` lLn N _ O t ,1 cn CN & N 111 • W O) 00 o pip O cc I� a rq o .0 � I rn � Ln U M.S.(fry) i I .S.(fnd) 100.70 S 080-37'-06W L I S A D R I V E M�p Ref: 'men Spam aJxb. LA-30 Alct P1m sect. 3 Mmutdryiew Batates So. Wir5scrr, Ct Raim E. BZI:a &ASS. scale:l"=401, 8/23/85, sh 2 of 9, H rev. 2/21/86 .Nr' u „ ,y South Windsor BUILDING DEPARTMENT i �) 5)4 �►�s�� CEn i-ic-i,;h 1 iO1N OF ZONING CONIPL'IA,4vE Proposed building(s), uses) andjor structure's) as shop: s to be in shown on this plan a�.�.ppez:r( ) �4 - confoirnance with current South �`dinici ,.._„n•- regulations. Variances and special exceptions may apply. 19�9 06 /Va Date Officer oning Enforcement 4.Alemo from TOWN OF SOUTH WINDSOR TOWN HALL SOUTH WINDSOR,CONN.06074 i i I i i I F TO Poolman Pools DATE 5/8/89 458 Talcobtville Road I Vernon, Ct. 06066 L SUBJECT: Suground pools Lisa Drive & Andreis Trail, South Windsor, CT. FOLD- TO WHOM IT MAY CONCERN: Before we can issue your permits for the above applications, please come in and sign the cards and also have the owners sign the enclosed memo regarding the necessity of fencing ppior to filling the pool. Thank you for your cooperation in this request, it was as i oversight by our departmaet. I I By Corinne H. Murray, Building Dept t0,0 sf'gl C � oi. S-(wziA ?+• /� � 1540 SULLIVAN AVENUE SOUTH WtNDSOR. CONN. 06074 �r AREA CODE 203/644-2511 �SOR•CV TO: All applicants for inground swimming pools FROM: John R. Collins, Chief Building Official DATE: May 16 , 1988 SUBJECT: FENCING REQUIREMENTS All pools are to be totally enclosed by at least some type of temporary fencing prior to filling the pool. Failure to do so will result in an immediate order to empty the pool by the South Windsor Building Department. I have read this notice and will comply. Po lica Date PERMIT DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT ��g Application is hereby : TOWN OF SOUTH WINDSOR APPROVED DIS BUILDING INSPECTION DEPT. 644-2511 Ext . 230 1? Application must be printed or typed. Date Building Inspec 1. LOCATION OF JOB 155 FEE SCHEDULE No . Street $ 0 - $19000 - $10 . 00 Floor Apt . No. Over $1 , 000 - $10 . 00 per $1 , 000 or 2 . OWNER RS6�Q i;:�Z=LA..M fraction thereof 3. ADDRESS l � 4 . APPLICANT J 5 . ADDRESS I 6 . E IMATED COST $ ��� 7 . IS THIS A CONTRACT COST Yes No 8 . FEE ENCLOSED $ C, . 9 . TYPE OF BUILDING : RESIDENTIAL COMMERCIAL 10. TYPE OF JOB : Original Installation Alteration/Addition/Repair BD 3A 11/88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11. LOCATION OF JOB i, -, Pie 0. STREET APT. NO, 12 . TYPE OF INSTALLATION 1pl7zS 2 S 13. SIZE OF MAIN FEEDER 14 . NO. OF LIGHT LOOPS 15 . NO. OF HEAT LOOPS 16. NO. OF POWER LOOPS— 17 . NO . OF LIGHT OUTLETS 18 . NO . OF HEAT CIRCUITS 19 . NO . OF POWER OUTLETS 20 . NO. OF CONVENIENCE OUTLETS 21 . NO . OF HEAT CIRCUITS 22 . NO. OF POWER CIRCUITS 23 . NO. OF LIGHT CIRCUITS 24. SIZE OF HEAT CIRCUITS 25 . NO . OF MOTORS 26 . NO. OF PANELS 27 . TOTAL WATTAGE 28 . NO. OF POWER FEEDERS 29 . NO. OF SWITCHES 30. A/C LOAD 31 . SIZE OF POWER FEEDERS 32 . NO. OF FIXTURES 33 . TOTAL HORSEPOWER 34 . NAME OF SUBCONTRACTORS AND THEIR TRADES -J5�6� ;Lvs�- AA� 35 . REMARKS AND FURTHER DETAILS : _ LICENSE N0 . SIGNAT E OF APPL A 'T DATE PHONE NUMBER: ::- 1 — 5;�-,s 3� FINA NSPECTIONS: Building APPLICATION FOR BUILDING PERMIT Plumbing HVAC 155 Lisa Drive Date: Sprinkler Estimated Cost $ Esti �Q El ctric Zoning 18541 Permit Fees Affidavit NO. Occupancy Fee $ Eng. Dept. COMPLETE RED BOXED AREAS. a� Fire Dept. TYPE OR PRINT ONLY Total Fee a Health Dept. SIGN ON REVERSE SIDE. Approved f r CO: (Additional Cost) $ TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Job Location / L%sue Lot No. Side of Street Zone Applicant Tel. # "` -6 Address !� L'sA 9Z - S 4d.-o7clrar 0�- Zip O 647Y Lic.# STREET ` CITY STATE Owner 6 i� L f�'��� ��� fia,x.e� Address /S's' 44 4 X7 G'1�- oG07`/ Architect `T✓YI 2 Address C s� '�h 164 51 t-)'"°�s°' L Size New Area: Ft. Front Overall Ft. Deep Overall Total Area #Garages No. of Families�—No. of Stories Construction w•dfsA ne Lavatories No. 1 st-l—' 2nd-:7-3rd Size of Lot Z4 161-.ee Dist. from Street Line Dist. from Side Street Line Purpose of this Permit Elnee t City Water R' Well 0 Septic ❑ Sewer L� Approved by Date - t-T a BD1A 11/88 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located th proper distance from all street lin s,side yard lines and r quired distanc s from all oth r zones and is located in a zone in which this building and its use is allowed. Signed I hereby apply for a Certificate of Occupancy for the work described in this application for permit. Signed —DO NOT WRITE BELOW THIS LINE— INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation Plumbing Permit# Inspections: HVAC Permit# Inspections: Electrical Permit# Inspections: Sprinkler Permit# Inspections: NOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: /0 03/ 5 (NO* 6 3 )4 ) TOWN OF SOUTH WINDSOR EST.COST: BLDG. PERMIT NO. 1540 SULLIVAN AVENUE FEE 3Q -- SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 $ 0 - $19000 - $10.00 $1000 or fraction thereof — $10.00 LOCATION OF BUILDING I 55 L)s A C2i v5- A16CAAMP-1�- 57T US'A DZi L6 5)UTH tj))Wsoz. C-T. CdN-C,00(0 OWNER ADDRESS TOWN PHONE NO. D'S HVAC Z C. - S� a� HVAC CONTRACTOR ADDRESS ITOWN PHONE NO. TYPE OF SYSTEM: HEATING _ TYPE OF BUILDING: RESIDENTIAL y A/C COMMERCIAL �`�' VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT 006ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE °F INSIDE OF DIFFERENCE °F TOTAL HEAT LOSS (BTUH) (HEAT LOSS SHEET MUSYL_ek_)q CCOMP N APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): SAI6 IU S C&J�)N_)6 6R-3 5jztAcE . Mc-Cc 1/twi- GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) QR,r.O0 IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE °F DIFFERENCE OF TOTAL HEAT GAIN (BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXRAUSE EQUIPMENT) : TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) (PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances an4Ste of Conn. Building Codes in the performance of such work. 1'�FURTHER DESCRIPTION OF WORK: 1 M 1S �S AU "` aKmml � -' s B(E CyqSa!ZkP A 3 m C Y UXOTTD NtCoct.' l 37(DIml TATE LICENSE - NAME & TYPE # DATE RE 0 PLICANT DATE I - B a A CALCULATION SHEET 1503 (Modern Method) Copyright 1971 by The Hydronks Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL A COL.9 COL.C COL.D COL.E COL.F CO, .G 1 ROOM l O H L W H L W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS, FT. ~ -- U OTUH Ov F of f 3 LENGTH EXPOSED WALLS.FT. t Radiation Selected d WINDOW AND OUTSIDE DOOR AREA IL STUH STUH STUH STUH STUN 5 WALL CONSTRUCTION (Table 9,Line 3 x H) ROOM LIH. FT.OF _ TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED 411 ttom of table used for L in*5) -7 CEILING CONSTRUCTION C (Table 9, L x W) S FLOORC0NSTRUCT I OONt - O_ (Table 9.L x W or Lin. F t) E 9 COLD PARTITION CONSTRUCTION F (Table 9, L x HI _ G t0 C 1 Wall(With Openings) �; H 2 Wells(With Openings! DX 3 Wells IWrlh Openings)or Ent.Hall J 1 J 11 TOTAL HTUH AT 70F TEMP DIFFERENCE' 17 TOTAL STUH AT DESIGN TEMP. DIFFERENCE K -- COL.A _ -`-- -__ COLS COL.M - COL.1 COL_J COL.K COL.L TOTAL STUH TOTAL I ROOM OF BUILDING RADIATION Q - — AT SELECTED O H L W H I L W H L W H L W H L W DESIGN TEMP.• 2 ROOM DIMENSIONS.FT I.' DIFFERENCE U -- — 3 LENGTH EXPOSED WALLS. FT d WINDOW AND OUTSIDE DOOR AREA LL STUH STUH OTUH STUH STUN 5 WALL CONSTRUCTION •INCREASE BATHROOM (Table 9, Line 3 x HI TOTAL 20% 6 TYPE OF GLASS (Bottom I table used for Line 51 --- - - - - tFOR CONCRETE FLOOR ON 7 CEILING CONSTRUCTION ( GROUND OR FILL AT Table 9. L x WI _ GRADE LEVEL,USE LINEAR B FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE (T able 9.L x W or Lin F t l 9 COLD PARTITION CONSTRUCTION !Table 9. L a H) 10 c 1 Wall(With Openings) C !— =0 ------ - -------- --- -- - - - ---------- — - 2 Walls(With Open-ngsl O X --- ---- - ---- ----- - 3 Wells(With Openings) r Ent Hall 11 TOTAL STUH AT 70F TEMP DIFFERENCE' 12 TOTAL STUH AT DESIGN TEMP DIFFERENCE - FORM 1503 This form Is available Ir m The Hydronlcs Institute, 35 Russo Plate,Berkeley Heights,N J 07922 Thursday September 28, 1995 TE12 Mr. and Mrs. Paul Kochanek 155 Lisa Drive South Windsor, CT 06044 HVAC L. L.C. (203) 644-6261 S-1 303316 P-1 202933 F-1 F11410 321 Silver Lane East Hartford, CT 06118 (203) 569-0501 GAS FURNACE REPLACEMENT PROPOSAL The proceeding proposal is based on information obtained from a walk through on Thursday September 28, 1995. Ted's HVAC LLC proposes to accomplish the following at the above address. * Disconnect and remove existing gas furnace. * Modify connection to chimney to accomodate the gas fired hot water heater only. * Furnish and install a Tech-4 90 plus percent efficient direct vent natural gas furnace on 4" blocks. This furnace has a capacity to move 2000 cfm of air or over. This is the same as 5 tons of cooling. * Furnish and install new supply and return metal/transitions to connect existing plenums to new furnace. * Wire and pipe all necessary connections as required by manufacturers installation instructions. * Furnish and install ABS combustion air and exhaust pipe. Owner responsibilities are as follows: * Owner to provide Ted's HVAC LLC with unrestricted access to any areas, inside or outside, to complete work as listed in this proposal/contract. Page 1 of 2 Thursday September 28, 1995 Mr. and Mrs. Paul Kochanek 155 Lisa Drive South Windsor, CT 06044 (203) 644-6261 GAS FURNACE REPLACEMENT PROPOSAL * Note * This proposal is based on there being a suitable area outside the house for obtaining combustion air for the new furnace as well as exhausting it. Proposed areas include the north west end of the house near the existing boiler direct vent. * Note * All installations are in accordance manufacturers installation instructions and comply with state and local codes. * All equipment installed by Ted's HVAC LLC is warranted against defects in workmanship for a period of one year unless otherwise stated in writing. Total cost of items listed above $ 2411.76 Payments are to be made as follows: Upon signing of contract $ 1205.88 Upon job completion $ 1205.88 The above prices, specifications, and conditions are for budgetary purposes only. The above pricing, specifications, and conditions serve as an example of an actual contract and its payment terms. i Christoph H. Mill Pres LLC utho e l rized Signature Date Page 2 of 2 F'2 ENT DECISION APPLICATION FOR ELECTRICAL PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application-is-hereby:ereby: 73 63 BUILDING DEPARTMENT PROVED 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230rZIG Bu'ding Inspector Application must be printed or typed Fo EE SCHEDULE Location of Job: -$1,000=$13.00 Street No. Street Lot No. Over$1,000= 13.00 per$1,000 ny fraction thereof Tenant Designation Apt.No. I i APPLICANT Q c APPLICANT ADDRESS r / Sew w+'k, S+i C{ - 0607 APPLICANT PHONE# 7 If' W N S OWNER OG aw,/, OWNER ADDRESS r J.. OWNER PHONE � A ESTIMATED COST$ IS THIS A CONTRACT COST? Yes ❑ No FEE ENCLOSED$ /.3-d O TYPE OF JOB: SOR.CO ❑ New Installation Alteration/Addition/Repair Revised 5101 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A ❑RESIDENTIAL BUILDING PERMIT APPLICATION�Y S ❑NO ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL ❑INSTITUTIONAL ENGINEER'S NAME PHONE ❑FACTORY ❑ STORAGE ADDRESS ❑GARAGE ❑MIXED USE CITY STATE ZIP TYPE OF INSTALLATION/WIRING METHOD SIZE OF SERVICE SIZE OF MAIN CONDUCTORS NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? ❑YES ❑NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK ZT � c;feu.' L THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 66 W A-4,i CONTRA TORS LICENSE NO. TY? STATE SIGNATURE OF APPLICAN DATE I ! O DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERNUT# 05-- Application is hcrcb,,-: TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Permit# APPROVE 1540 SULLIVAN AVENUE n2 ko Q 16 6- (:!A�Joh 644-2511 ext. 230 date Buiding Inspector Application must be printed or typed Location of job L15 A 0P,LILF- 7 Street No. Street Lot No. FEE SCHEDULE Floor Apt. No. $0 - $1,000 - $12.00 Over $1.000 $12.00 per$1,000 OWNER IAL X. VACdM)PY or any fraction thereof I - - ADD SS ELI L T OWNERS PHONE# TKO•- ���lf-1D0��1 APPLICANT :TW7 S W—)L ( W N $ ADDRESS '3a\ 2211 5�C-T ESTIMATED COST $ /91 IS THIS A CONTRACT COST? YES NO db CI FEE ENCLOSED $ 0 CO TYPE OF JOB: Original Installation Alteration/Addition Repair Revised 11/95 APPLICATION FOR HVAC PERMIT(Continued from reverse side) TYPE OF SYSTEM TYPE OF BUILDING HEATING � RESIDENTIAL A/C _� COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT S. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR L UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE.., F INSIDE�Nj DIFFERENCE n F TOTAL HEAT LOSS(BTUH) (HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE&MODEL NO.) l%D WW alMAIA. rQE 8aMlFtJTC_0 3� F013 66- GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) TYPE OF FUEL OIL-GPM GAS-INPUT ELECTRIC-KW OIL TANK SIZE&LOCATION INSIDE OUTSIDE CAPACITY LPG TANK CAPACITY AIR CONDITIONING DESIGN TEMP. OUTSIDE5 F INSIDE:�Q F DIFFERENCE73 F TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE&MODEL NO.) btcfflzia:x��x N TONNAGE 'GOQ COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH WO ATE LICENSE-NO. NAME&TYPE TUR 5 Of��fgC_ j 1 PHONE NO. � �� DATE * TED'S HVAC LLC * PROJECT: CONTEMPORARY 321 SILVER LANE CLIENT: PAUL KOCHANEK EAST HARTFORD, CT 06118 DATE: AUGUST 1, 2001 RESIDENTIAL/LIGHT COMMERCIAL HVAC LOADS DESIGNER: CHRIS MILLER CLIENT INFORMATION: NAME: PAUL KOCHANEK ADDRESS: 155 LISA DRIVE CITY, STATE: SOUTH WINDSOR CONNECTICUT TOTAL BUILDING LOADS: alyy*m" �km coot-& rl' 3 ------------------------------------------------------------------------------ BLDG. LOAD AREA SEN. LAT. + SEN. = TOTAL DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN ------------------------------------------------------------------------------ 1-C WIND. CLEAR GLASS METAL FRAME 12 1, 068 0 922 922 15-C WALL 2-5'BLW GRD 8/12" BLK+R-11 753 2, 956 0 0 0 22-C SLAB ON GRADE 11/2"EDGE INS (R-8) 105 2, 183 0 0 0 ------------------------------------------------------------------------------ SUBTOTALS FOR STRUCTURE: 870 6,207 0 922 922 PEOPLE 5 0 1, 150 1, 500 2, 650 APPLIANCES 0 0 0 2,200 2, 200 DUCTWORK 0 645 0 288 288 INFILTRATION W.CFM: 79.1 S.CFM: 45.2 0 6, 703 1, 076 1, 144 2,220 VENTILATION W.CFM: 0.0 S.CFM: 0.0 0 0 0 0 0 ------------------------------------------------------------------------------ SENSIBLE GAIN TOTAL 6, 054 TEMP. SWING MULTIPLIER X 1.00 BUILDING LOAD TOTALS 13, 555 2,226 6, 054 8,280 ------------------------------------------------------------------------------ SUPPLY CFM AT 40 DEG HTG DT: 308 CFM PER SQUARE FOOT: 0.332 SQUARE FT. OF ROOM AREA: 929 SQUARE FOOT PER TON: 1,346.377 TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 13.555 MBH TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 0.690 TONS CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J. ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY. BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS. ******** RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* * TED'S HVAC LLC * EAST HARTFORD, CT 06118 CONTEMPORARY AUGUST 1, 2001 PAGE 2 ************************ TOTAL ZONE LOADS FOR ZONE # 1 *********************** ------------------------------------------------------------------------------ BLDG. LOAD AREA SEN. LAT. + SEN. = TOTAL DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN ------------------------------------------------------------------------------ 1-C WIND. CLEAR GLASS METAL FRAME 12 1, 068 0 922 922 15-C WALL 2-5'BLW GRD 8/12" BLK+R-11 753 2, 956 0 0 0 22-C SLAB ON GRADE 11/2"EDGE INS (R-8) 105 2, 183 0 0 0 ------------------------------------------------------------------------------ SUBTOTALS FOR STRUCTURE: 870 6,207 0 922 922 PEOPLE 5 0 1, 150 1, 500 2, 650 APPLIANCES 0 0 0 2,200 2,200 DUCTWORK 0 645 0 288 288 INFILTRATION W.CFM: 79.1 S.CFM: 45.2 0 6, 703 1, 076 1, 144 2,220 VENTILATION W.CFM: 0.0 S.CFM: 0.0 0 0 0 0 0 ------------------------------------------------------------------------------ SENSIBLE GAIN TOTAL 6, 054 TEMP. SWING MULTIPLIER X 1.00 BUILDING LOAD TOTALS 13, 555 2,226 6, 054 8,280 ------------------------------------------------------------------------------ SUPPLY CFM AT 40 DEG HTG DT: 308 CFM PER SQUARE FOOT: 0.332 SQUARE FT. OF ROOM AREA: 929 SQUARE FOOT PER TON: 1, 346.377 TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 13.555 MBH TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 0. 690 TONS CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J. ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY. BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS. ******** RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* * TED'S HVAC LLC * EAST HARTFORD, CT 06118 CONTEMPORARY AUGUST 1, 2001 PAGE 3 ************************* MISCELLANEOUS PROJECT DATA ************************* DESIGN CONDITIONS: WINTER SUMMER OUTDOOR DRY BULB TEMPERATURE -5 DEG.F 95 DEG.F INDOOR DRY BULB TEMPERATURE - ZONE 1 72 DEG.F 72 DEG.F DESIGN TEMPERATURE DIFFERENCE - ZONE 1 77 DEG.F 23 DEG.F INDOOR-OUTDOOR GRAINS DIFFERENCE 35 GRAINS OUTDOOR DAILY TEMPERATURE RANGE MED GENERAL PROJECT DATA: PROJECT DATA FILE NAME: C:\ELITE\KOCHANEK TOTAL GROSS WALL AREA (SF) : 765.00 NON-GLASS DOOR AREA (SF) : 0.00 TOTAL NET GLASS AREA (SF) : 12.00 TOTAL SKYLIGHT AREA (SF) : 0.00 TOTAL NET WALL AREA (SF) : 753.00 TOTAL NET ROOF AREA (SF) : 0.00 TOTAL EXPOSED AREA (SF) : 765.00 PEOPLE LATENT LOAD MULTIPLIER: 230.00 PEOPLE SENSIBLE LOAD MULTIPLIER: 300.00 LATITUDE DEGREES: 41.00 TEMPERATURE SWING MULTIPLIER: 1.00 EXTERNAL SHADING TYPES: NO. OVERHANG OFFSET ---- -------- ------ 1. 3.0 1.0 2. 5.0 0.0 3. 4 .0 0.5 4. 0.0 0.0 5. 0.0 0.0 6. 0.0 0.0 7. 0.0 0.0 OUTSIDE AIR DATA: WINTER SUMMER INFILTRATION AIR CHANGES PER HOUR: 0.700 0.400 CUBIC FEET OF CONDITIONED SPACE: X 6, 783 X 6,783 -------- -------- 4, 748 2, 713 X 0.0167 X 0.0167 -------- -------- TOTAL BUILDING INFILTRATION CFM: 79.1 45.2 TOTAL BUILDING VENTILATION CFM: 0.0 0.0 INFIL. & VENT. SEN. GAIN MULTIPLIER: 25.30 = (1. 10 X 23 SUMMER TEMP. DIFF. ) INFIL. & VENT. LAT. GAIN MULTIPLIER: 23.80 = (0. 68 X 35 GRAINS DIFFERENCE) INFIL. & VENT. SEN. LOSS MULTIPLIER: 84.70 = (1.10 X 77 WINTER TEMP. DIFF. ) • ******** RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* * TED' S HVAC LLC * EAST HARTFORD, CT 06118 CONTEMPORARY AUGUST 1, 2001 PAGE 4 **************************** DETAILED ROOM LOADS ***************************** ITEM AREA -U- HTG SEN. CLG LAT. SEN. DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN --------------------------- ------ ------ ----- ------- ----- ------ ------- 1. WSE BASEMENT ROOM 26.5 WID X 20.6 LEN = 546 SF CEIL.HT = 7.3 W -WALL-15C 7.3 X 20. 6 147 0.051 3. 9 577 0.0 0 0 E -WALL-15C 7.3 X 20.6 144 0.051 3.9 565 0.0 0 0 S -WALL-15C 7.3 X 26.5 193 0.051 3. 9 758 0.0 0 0 W -GLAS-lC 1-P 0-0 S-1 OoS 3 1.155 88. 9 267 91.3 0 274 E -GLAS-lC 1-P 0-0 S-1 OoS 3 1.155 88. 9 267 91.3 0 274 E -GLAS-lC 1-P 0-0 S-1 OoS 3 1. 155 88.9 267 91.3 0 274 FLOOR-22C 67 FT 67 0.270 20.8 1, 393 0.0 0 0 INFIL. W: 59.4 S: 33. 9 9 558. 6 5, 027 95.3 807 858 DUCTWORK 0.050 456 0.050 0 114 PEOPLE 2 230 300 460 600 ROOM TOTALS 9, 577 1,267 2, 394 2. WEST AREA 12.4 WID X 12.5 LEN = 155 SF CEIL.HT = 7.3 W -WALL-15C 7.3 X 12.5 91 0.051 3. 9 357 0.0 0 0 FLOOR-22C 12.5 FT 13 0.270 20.8 270 0.0 0 0 INFIL. W: 0.0 S: 0.0 0 558. 6 0 95.3 0 0 DUCTWORK 0.050 31 0.050 0 15 PEOPLE 1 230 300 230 300 ROOM TOTALS 658 230 315 3. STORAGE 1 6.0 WID X 18.7 LEN = 112 SF CEIL.HT = 7.3 E -WALL-15C 7.3 X 18.7 137 0.051 3. 9 538 0.0 0 0 N -WALL-15C 7.3 X 6 41 0.051 3. 9 161 0.0 0 0 N -GLAS-lC 1-P 0-0 S-1 OoS 3 1.155 88. 9 267 33.3 0 100 FLOOR-22C 24.7 FT 25 0.270 20.8 520 0.0 0 0 INFIL. W: 19.8 S: 11.3 3 558. 6 1, 676 95.3 269 286 DUCTWORK 0.050 158 0.050 0 34 PEOPLE 1 230 300 230 300 ROOM TOTALS 3, 320 499 720 ******** RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* * TED'S HVAC LLC * EAST HARTFORD, CT 06118 CONTEMPORARY AUGUST 1, 2001 PAGE 5 **************************** DETAILED ROOM LOADS ***************************** ITEM AREA -U- HTG SEN. CLG LAT. SEN. DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN --------------------------- ------ ------ ----- ------- ----- ------ ------- 4 . PAUL'S OFFICE 12. 9 WID X 9.0 LEN = 116 SF CEIL.HT = 7.3 INFIL. W: 0.0 S: 0.0 0 558. 6 0 95.3 0 0 DUCTWORK 0.050 0 0.050 0 125 PEOPLE 1 230 300 230 300 APPLIANCES 0 2, 200 ROOM TOTALS 0 230 2, 625 r ******** RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* * TED'S HVAC LLC * EAST HARTFORD, CT 06118 CONTEMPORARY AUGUST 1, 2001 PAGE 6 ************************* ZONE # 1 ROOM LOAD SUMMARY ************************* ------------------------------------------------------------------------------ RM ROOM AREA ------ HEATING ------ ------ COOLING ------ NO. DESCRIPTION (SF) BTUH % TOT CFM BTUH % TOT CFM ------------------------------------------------------------------------------ 1. WSE BASEMENT ROOM 546 9, 577 70.7 218 2, 394 39.5 104 FEET OF RADIATOR 17 2. WEST AREA 155 658 4.9 15 315 5.2 14 FEET OF RADIATOR 1 3. STORAGE 1 112 3, 320 24.5 75 720 11.9 31 FEET OF RADIATOR 6 4 . PAUL'S OFFICE 116 0 0.0 0 2, 625 43.4 114 FEET OF RADIATOR 0 ------------------------------------------------------------------------------ ZONE SUBTOTAL 929 13, 555 100.0 308 6, 054 100.0 262 LATENT GAIN 2,226 ZONE TOTALS 13, 555 8,280 0. 690 TONS ------------------------------------------------------------------------------