Loading...
HomeMy WebLinkAbout16 Lakewood (2) L� T 0 THE BUILDING INSPECTOR 351 of the APPLICATION FOR PLAN EXAMINATION AND TOWN OF SOUTH WIIrDSOR, COHH. BUILDING PERMIT IMPORTANT — Applicant to complete all items in sections: 1, It, III, IV, and 1X. O / ZONING I• AT (LOCATION) �QI/_ -1�`�� DISTRICT LOCATION (NO.) (STREET) OF BETWEEN 94316 !' Ind 11 AND (CROSS STREET) BUILDING (CR SS STREET) �,J LOT SUBDIVISION DPW add LOT S BLOCK SIZE N ll. TYPE AND COST OF BUILDING — All applicants complete Parts A — D A. TYPE OF IMPROVEMENT D. PROPOSED USE — For"Wrecking" most recent use m m 1 New building Residential Nonresidential 2 ❑ Addition(l/residential, enter number 12 One family 18 ❑ Amusement, recreational o/new housing units added, if any, 13❑ Two or more family - Enter 19 ❑ Church, other religious in Part D, 13) number o/units- - - - --p- 20❑ Industrial 3 ❑ Alteration (See 2 above) 14 ❑ Transient hotel,motel, 21 ❑ Parking garage 4 ❑ Repair, replacement or dormitory - Enter number 5❑ Wrecking (1/multifamily residential, of units ------- - -! 22 E] Service station, repair garage enter number of units in building in 15❑ Garage 23❑ Hospital, institutional Part D, 13) 16 ❑ Carport 24❑ Office, bonk, professional 6❑ Moving (relocation) 17❑ Other - Speci/y 25❑ Public utility 7 ❑ Foundation only 26❑ School, library, other educational B. OWNERSHIP 27❑ Stores, mercantile 8 Private (individual, corporation, 28 E:] Tanks, towers nonprofit institution, etc.) 29❑ Other - Specify 9 ❑ Public (Federal, State, or local government) C. COST (Omit cents) Nonresidential - Describe in detail proposed use of buildings, e.g., food processing plant, machine shop, laundry building at hospital, elementary 10. Cost of improvement,,,,,,,,,,,,,,,, school, secondary school, college, parochial school, parking garage for. 01 department store, rental office building, office building at industrial plant. To be installed but not included If use of existing building is being changed, enter proposed use. in the above cost a. Electrical...................... L b. Plumbing ...................... ✓ e.Heating, air conditioning......... d. Other(elevator, etc.)............ 11. TOTAL COST OF IMPROVEMENT $ III. SELECTED CHARACTERISTICS OF BUILDING — For new buildings and additions, complete Parts E — L; for wrecking, complete only Part J, for all others skip to IV. E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS 30 L J Masonry(wall bearing) 40 ''Public or private company 48• Number of stories................ 31 �' and frame 41 ❑ Private (septic tank, etc.) 49. Total square feet of floor area, all floors,based on exterior // ,,. 32❑ Structural steel dimensions .................... A fD 33❑ Reinforced concrete H. TYPE OF WATER SUPPLY 34❑ Other — Specify 42 'Public or private company 50• Total land area, sq. ft. ........... ZA 43❑ Private(well, cistern) K. NUMBER OF OFF-STREET PARKING SPACES 1 51. Enclosed ...................... r F. PRINCIPAL TYPE OF HEATING FUEL 1. TYPE OF MECHANICAL 35 Q'Gos Will there be central air 52. Outdoors........................ / 96❑ Oil conditioning? L. RESIDENTIAL BUILDINGS ONLY 37❑ Electricity 44❑ Yes 45 t-t ^a 53. Number-of bedrooms.............. 38 ❑ Coal 39❑ Other- Specify Will there be an elevator? 54. Number of Full.......... 46❑ Yes 470 No bathrooms T Partial....... V IV. IDENTIFICATION — To be completed by all applicants Name Mailing address — Number, street, city, and State ZIP code Tel. No. Owner or R�L Wltnn Zw.- 4 a A 6,1 Lessee F/q 2. Contractor 3 Architect or e E4aT _ a� 1,1� 6yy— Engineer ,11 (091 The owner of this building and the undersigned agree to conform to all applicable laws of this jurisdiction. Signotur of applicant AdJress Application dote 41-2 00 NOT WRITE BELOW THIS LINE V. PLAN R EVI EW RECORD — For office use Plans Review Required Check Plan Review Date Plans By Date Plans B Notes y Fee Started Approved BUILDING PLUMBING MECHANICAL ELECTRICAL $ , OTHER VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS Permit or Approval I Check Dote Number B Permit or Approval I Check Date Number By pp Obtained y pp Obtained BOILER PLUMBING CURB OR SIDEWALK CUT ROOFING ELEVATOR SEWER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OIL BURNER WRECKING OTHER OTHER VII. VALIDATION Building Permit number Building Permit issued ��`� 19 �B Building Permit Fee rov by: c � TITL • ` TOWN OF SOUTH WINDSOR BUILDING PERMIT Date June 25 19 8 6 Fee Paid $. 3A 8 .0 0 Eat. Value ,0 0 0 Permit N? 15223 on the aide of Lot #32 Pintail Circle Sant Street No. 32 Owner RSK Kellco Inc. Applicant Carol S. Kelley CERTIFICATE OF OCCUPANCY ISSUED: Date No. 7665 Fee Paid $ 3 .0 0 CLASSIFICATION Dwelling BUHDj NG PERMIT N" 15223 OFFICE OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. South Windsor, Conn. June 25 106 T#19 'to to Certify, That , is hereby granted permission to Dwelling at estimated value of on the side of 3.Q4- 21�4. =ta_' C d C-G l e Street on land owned by 22KmKoll ao Xag Said work to be as described in Application No. and to conform to spedfications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH WINDSOR. Issued suers 25 1986 -Building Inspector. Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: "When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costs and damages which it shall sustain, or be compelled to reason therefor." z, Dwelling - Lot #32 LKWD �/25/86 RSK Kellco Inc . 32 Pintail Circle Permit #15223 Electrician Michael Finnegan #9560 Heating Contr. Mellen Energy Corj# 6647 Plumbing It Mellen Energy Corp. #7201 Oil Burner # Certificate of Occupancy # 7665 Sewer Permit Plot plan apprd. per Engr. I I I j Permit No. TOWN OF SOUTH WINDSOR SOUTH WINDSOR, CONN. I I I I I I Permit N4 7665 I I Certificate of Occupancy THIS 15 TO CERT-VY th9it the - �- at No. in the, own of South Windsor, Connecticut, has been erected and completed in accordance with the Bui ing Code and Zoning Regulations of the Town of South Windsor, and is hereby appr8ved f r occupancy. I Building Inspector I owner, Builder -, r _,AI" Fee Paid Date Z 7 P 9560 ELECTRICAL APPLICATION Application No. 11069 on the side of Lot #32 Pintail Circle Street Street No. 32 Owner RSK Kellco Inc . Electrician Michael Finnegan FILED IN OFFICE OF The Building Inspector Feb. 11 19 87 INSPECTION. cw No Electrical Work shall be started until a Per- mit is granted by the Building Inspector. In New Buildings no wiring shall be started until the plumbing and heating pipes, and the fire stops (if of wood) are installed, without a special permit from the office of the Building Inspector. Electrical Permit No. ....... ..•S.......................................... Master License No. .../._. ...7... .............. TOWN OF SOUTH WINDSOR Building Permit No. ....r.5... J�.................... BUILDING DEPARTMENT Date Filed .................... ............................. DateFinal Approval ..........................................._..... APPLICATION FOR ELECTRICAL WORK Electrical Inspector JOBLOCATION. ....... .. .................... JOB OWNER: ..............j�........................................................................................ Sideof . Between ......... . ........................................... ...... and ................................................................................. Nameof Building Owner T-'� ........ Address . ..................................... ... ......................._....................... Ifwork is for Lessee—Give name . ..... .. .. .......... ........... ............. Address ...................................._........................................................... Building now occupied as (unless new) ................. ....... No. of family units now ..... . .. 7............. Building to be occupied as ......... 1.. .. Number of family units to be ....... ...�............... ... .. ..... ................. Is this work included irLa Buildin Permit ...... Permit Fee ............... ......................................................................................................_..... (If no Building Permit) Permitte Business Address .� •.... Telephone L ? ..,.� - Zr._... S COST OF INSTALLATION: 7. ....... .................................... ..... v ........�r � ...... .....6 .1? .�u............................................................ _ TO BE FILLED OUT BY PERMITTEE TO BE WIRED EXISTING APPLIANCES Number of light outlets to be installed ......... Number of convenience outlets to be installed Number of present Appliance Circuits ................................................... Number of switches to be installed . . . .. Do these include Range ❑ Water Heater ❑ Number of appliances to be installed . . . ....... .................. (as listed below) Dryer ❑ Air Conditioner ❑ Oil Burner ❑ TYPE RATING NO. Dish Washer ❑ Gas Burner ❑ Range . . . . . . . . Well Pump ❑ Elec. Heaters ❑ Range Top . . . . . . Oven . . . . . . . . REMARKS: Water Heater Clothes Washer . . . . Clothes Dryer . . . . . C Dish Washer . . . . . . Air Conditioning Motor . Oil Burner Motor . . . . Gas Burner . . . . . . Circulator Motor . . . . Attic or Large Fan , , , Well Pump . . . . . . Electric Heat . . . . . Other . . . . . . . Number of new Lighting Circuits _................ ..... Number of new Appliance Circuits _...._........... Number of Heating Circuits . . . _................. Number of Motor Circuits . . . . . . . ....._..... ...._....._ Size of present service ................ ..........................................._............ _..._ Size of service to be .............................................................._...... ---- 7201 PLUMBING APPLICATION wppbadm Nm 6 8 71 on the idc of Street i4o. Plumber Filed in Offwe of The Bold6g b qn mr Degember 9 j936 II�11 wry NIL No person OW aort om add ID w aloes ay portion of the dabuW Wma of aw bald'iag (ezapt to repair le 6) oa&a Plerait is gcm�d by the Building b pamr- APPLICATION FOR PLUMBING PERMIT (Continu d from R v rs Side) TOWN OF SOUTH WINDSOR, CONN. 11. LOCATION OF JOB Z, / 3,2, Pzt, l2x! ,�- (L1,P-s- le- NO. STREET FLOOR APT.NO. GENERAL PLUMBING 12. KIND OF INSTALLATION 13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS .2= STYLE 15. NO. OF URINALS�_STYLE 16. NO.OF BATHTUBS 17.NO.OF LAVATORIES 18. NO.OF SINKS_.�_19. NO. OF WASHTUBS 20. NO.OF CONDUCTORS COD SIZE 21. NO. OF STACKS _SIZE 22. AREA OF ROOF 23.NO. OF CATCH BASINS 4. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW Z- Y-'� 28. IF NO WINDOW,WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. ARE SEWAGE AN WATER FACILITIES AVAILABLE? SIGNATURES ADDRESS v V LICENSE NO. o?03)'// ESTIMATED COST TELEPHONE 2- d}�/ OWNE -k� ADDRESS WATER HEATER 31. TYPE - 32. MANUFACTURER-A F:22YI-a/Lt TANK SAFETY DEVICES 33. CAPACITY Lo 37. TEMPERATURE RELIEF VALVE i 34. TEST PRESSURE -3 G/l/ 38. MANUFACTURER 35. WORKING PRESSURE 39. PRESSURE RELIEF VALVE 36. TYPE 40. MANUFACTURERS ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE OWNER OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. C0962 DATE ATURE OF APPLICANT PERMIT # Application For 6445 6647 6 DEPARTMENT DECISION $e8t$� Permit g 0 3 APPLICATION IS HEREBY: DEPARTMENT OF LICENSES AND INSPECTIONS at APPROVED DISAPPROVED TOWN OF SOUTH WINDSOR c �, �9 —R 6 OD 0 DATE ciati, wastmv APPLICATIONS MUST OE PRINTED 00 TTPED. DECM WITH MYMDEN ME BELOW O to 4j >b A 1. LOCATION OF JOB o 3 o� LOT NO* FLOOD 0 s. OWNER a E o a. ADDRESS �'—JSJINONE4V4 a bob .� •. APPLICANT ADDRESS •^ s.PHONE��U� w � s. LICENSE NO. ) 7 4q 9 *. EXPIRATION DATE OF LICENSE 1&--/ 5r 10. ESTIMATED COST s 3 d 11. IS THIS A CONTRACT COSTI YES No be Perm-i;,15223 O 12. FEE ENCLOSED s y 1a. TYPE_0 u1LDING: P1 �'MEsroENT1AL ❑ CON1414CIAL O R ❑ d 14. TYPE OF C JOB: INDUSTRIAL G MSTALLATION ❑ ADDITIIONON REPAIR APPLICATION FOR HEATING PERMIT (Continued from Rev no Side) 11. LOCATION OF JOB ` 1AyTAl1L C N STRLST FLOOR AFT.M . 12. TYPE Of INSTALLATION: ❑ OIL BURNER ❑ ELECTRIC ❑ valmATION ❑ SMdNKLER ILd'GAS BURNER ❑ STACK ❑ INCINERATOR ❑ MISCELLANEOUS IOSNTIFT SIZE LOCATION SIZE SIZE 13. OF TANK OF TANK OF FILL OF VENT t B.T.U. EQUIP. AT REGISTER_ e p CE MAKE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NO. - B.T.U. OR SQ. FT. NET B.T.U. OR SO. FT. GROSS FIRING RATE FLOORS TO BE HEAT D - NEW OR OLD BUILDING M'PC4 Ily ULATED - YES OR NO TYPE OF WALL INSULATION ROOF OR CEILING INSULATION AVG. SYSTEM WAT R TEMP. B. .U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE lez) *FAHRENHEIT MAKE OF RADIATION: 8 SEBO RD. COPPER CONV TORS. OR C.I. RADIATION. OUTPUT PER CTION OR LINEAL OF RADIATION. SO. FT. OR B.T.U. `� DESCRIPTION OF WORK 15. TO BE DON is HEAT LOSS SCHEDULE, (TO BE INCLUDED FOR ALL JOBS): WIND ROOM slZs AMC "S AREA — SQUARE FEET �� a•OT•LL 0•T•U. i DISTRIBUTION INSTALLED COOLAM TTAL TCTAL 2. t R Y M0• 3 ORCY O OR LAU NKT WALL CUILINO FLO CU.FT. AT M'F CORRECT90 J j R<CIST<R L W N AND t MALL to IINFILT.) Tt~. TC • It f O TVFt ANO!IZ< !O AO O. R"AOtR III Zt < �'C OIFF. R F • FRKS AR<A TOTALS A. HEAT LOSS FROM BUILDING S B.T.U./HR. 8. DOMESTIC HOT WATER DEMAND B.T.U./HR. C. PIPING.OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A 8 C) FACTOR �� O 17. ELECTRICAL WORK BY: 6- NAN9 AO01119Si SUBCONTRACTORS AND 1 s. THEIR TRADES - - ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE(OWNER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. APPLICATION TO BE COMPLETELY FILLED IN. ATS SIGN RS OF APPLICANT I I r I = B= R CALCULATION,SHEET1503 (Modern Method) Copyright 1977 by The Hydronics Institute AWN El _3L w•A' c•1 O 1'4 C(i[/V [ir ` S� ADDRESS L/J DESIGN TEMPERATURE DIFFERENCE�F. DATE --"" COL.A COL.B Ir r COL.C COL.D COL.E COL.F COL.G 1 'ROOM f'd� C T` %'l"Y!J '�.'�J ' i1�1 -) )' kin rrit�cs . L? R+ O H L W H L W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS, FT. ~ �� ��' v I Cl � ' l t' k �� U BTUH per Foot of +^ 3 LENGTH EXPOSED WALLS, FT. Q '� 33 � Cf Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA LL u7 (, 3 BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION ROOM LIN. FT.OF (Table 9, Line 3 x H) .�� V V v Q d0 np2 / D d 3 04 TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED (Bottom of table used for Line 5) 3 1-'OQ f J C) o o a C_�� O `� � r EILING 7 (CTable 9, L CONSTRUCTION C )TRUCTION 'U; 3oa 00 � ,t' r ^' � D a B FLOOR CONSTRUCTIONt C)U (Table 9, L x W or Lin. Ft.) E "� L)d 9 COLD PARTITION CONSTRUCTION F ')0 Q f (Table 9, L x H) �j G 10 _c 1 Wall(With Openings) 3 ;/- H 3LOCI C a 2 Walls(With Openings) D J 3 Walls(With Openings) or Ent.Hall 1 J M /� / 11 TOTAL BTUH AT 70F TEMP. DIFFERENCE' V �;o G a '7' v U (O ` 12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE / (� ✓f 17 r, a L COL.A COL.B COL.H COL. I COL.J COL. K COL.L TOTAL BTUH TOTAL 7 OF BUILDING RADIATION 1 ROOM X I 7 ° ~4 i', 1t► �.i1' AT SELECTED O H L W H L W H DIFFERENCE L W H L W H L W DESIGN TEMP.' 2 ROOM DIMENSIONS, FT. U a - L ' f i J 220 3 LENGTH EXPOSED WALLS, FT. Q if Q 4 WINDOW AND OUTSIDE DOOR AREA LL BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION *INCREASE BATHROOM (Table 9, Line 3 x H) 3 D Q Q O �_ 0 o TOTAL 20% 6 TYPE OF GLASS (B ttom of table used for Line 5) .5 O O I 3 °� 7 J. 7 tFOR CONCRETE FLOOR ON CEILING CONSTRUCTION (Table 9, L x W) -' GROUND OR FILL AT QD v f 0 QQ 900 GRADE LEVEL,USE LINEAR B FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE (Table 9, L x W or Lin. Ft.) 9 COLD PARTITION CONSTRUCTION (Table 9, L x H) 10 c 1 Wall(With Openings) C Q �Q =o 7 c q 2 Walls(With Openings) D X Sao 3 Walls(With Openings) or Ent.Hall J 11 TOTAL BTUH AT 70F TEMP. DIFFERENCE' 3 QQ Qd 3 U 12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE �IxQ Q FORM 1503 This form is available from The Hydronics Institute,35 Russo Place,Berkeley Heights, N.J.07922