Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
128 Kelly Road
�36 TO THE BUILDING INSPECTOR of the APPLICATION FOR TOWN OF SOUM WINDSM CON. PLAN EXAMINATION AND BUILDING PERMIT IMPORTANT — Applicant to complete all items in sections: 1, 1 111, IV, and IX. O • AT ('LOCATION) ZONING DISTRICT LOCATION (NO.) (STREET) OF BETWEEN AND BUILDING (CROSS STREET) (CROSS STREET) LOT SUBDIVISION LOT BLOCK SIZE II. TYPE AND COST OF BUILDING — A11 applicants complete Parts A — D A. TYPE OF IMPROVEMENT D. PROPOSED USE — For"Wrecking" most recent use m T 1 ❑ New building -4 Residential Nonresidential 2 ❑ Addition(1/residential, enter number 12❑ One family 18❑ Amusement, recreational of new housing units added, i/any, in Part D, sin a 130 Two or more family — Enter 19❑ Church, other religious number of units— — — — --). 20 Industrial 3 ❑ Alteration (See 2 above) 14 ❑ Transient hotel, motel, ❑ 4❑ Repair, replacement or dormitory — Enter number 21 parking garage 5❑ Wrecking (1f multifamily residential, of units ——————— — -Im. 22 ❑ Service station, repair garage enter number of units in building in 15❑ Garage 23❑ Hospital, institutional Part D, 13) 16 ❑ Carport 24❑ Office bank professional 6 ❑ Moving (relocation) , 17❑ Other — Specify AE !�`-/Qdy/ 250 Public utility 7 ❑ Foundation only 26❑ School, library, other educational B. OWNERSHIP a �'" 27❑ Stores, mercantile 8 2 Private(individual, corporation, 28 ❑ Tanks, towers nonprofit institution, etc.) ��`��� 29❑ Other — Specify 9 ❑ Public(Federal, State, or local government) C. COST (Omit cents) Nonresidential — Describe in detail proposed use of buildings,e.g., food processing plant, machine shop, laundry building at hospital,elementary 10. Cost of improvement,,,,,,,,,,,,,,,, S 0 0O p0 school, secondary school, college, parochial school, parking garage for, department store, rental office building, office building at industrial plant. To be installed but not included If use of existing building is being changed, enter proposed use. in the above cost a. Electrical...................... b. Plumbing ...................... c.Heating, air conditioning......... d. Other(elevator, etc.)............ 'i4G& 7 Zr 1G`�" � of 11. TOTAL COST OF IMPROVEMENT s III. SELECTED CHARACTERISTICS OF WILDING — For new buildings and additions, complete Parts E — L; for wrecking, complete only Part J, for all others skip to IV. E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS 30❑Masonry(wall bearing) 40❑ Public or private company 48• Number of stories................ 31 W ad frame 41 ❑ Private (septic tan 49. Total square feet of floor area, k, etc.) all floors, based on exterior 32❑ Structural steel dimensions . 33❑ Reinforced concrete H. TYPE OF WATER SUPPLY ......••....•.•.•... 34❑ Oth r — Specify 42❑ Public or private company 50. Total land area, sq.ft. ........... 43❑ Private(well, cistern) K. NUMBER OF OFF-STREET PARKING SPACES F. PRINCIPAL TYPE OF HEATING FUEL I. TYPE OF MECHANICAL 51. Enclosed ....................... 35❑ Gas Will there be central air 52. Outdoors....................... 96❑ Oil conditi ning? ❑ ❑ L. RESIDENTIAL BUILDINGS ONLY 37❑ Electricity 44 Yes 45 No 53. Numb r f b dr ms.............. 38❑ C al 39❑ Oth r— Specify Will there be an elevat r? Full.......... 54. Number f 46❑ Y s 47❑ No bothr ms Partial....... NOTES and Data — (For department use) IV. IDENTIFICATION — To b compl t d by all applicants Name Mailing address — Number, street, city, and State ZIP cod Tel. No. Owner or Lessee 2. P Co V4 : TjQ 7 �7 O Contractor 30 3. Architect or Engineer The owner of this building and the undersigned agree to conform to all applicable laws of this jurisdiction. Signatur f applicant Address Applicat'on date tl 00 NOT WRITE BELOW THIS LINE V. PLAN REVIEW RECORD — For office use Plans Review Re uired Check Plan Review Date Plans B Date Plans By Notes q Fee Started y Approved BUILDING $ PLUMBING $ MECHANICAL $ ELECTRICAL $ OTHER $ VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS Permit or Approval I Check Date Number B Permit or Approval I Check Dote lumber By pp Obtained y pp Obtained BOILER PLUMBING CURB OR SIDEWALK CUT ROOFING ELEVATOR SEWER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OIL BURNER WRECKING OTHER OTHER VII. VALIDATION Building Permit number 12354 Building Permit issued ALjZ_ 24 19 Al Building Permit Fe $ 36.00 Approved by: J TITLE • ii• •••! •!• •• P•• sl..• •.......•••..•w•�� ••�1.1 • ••••�.••�.w• ••� • • • N• • w • • !! • N Swe"•ii. \ •aa�ir a■■ "a IN N�•1a�w a�/•fN=.3.aai• i �iaS.�iif r �' r • ■ r' si. s * . s s ;ss i$: = •:i:::i;� �i •a" 1iuiF�=a =ira a :�ria� r�■ri R • r. �iN� ra N.■ • NN ii : .a'�rr t •• •w�• :'a • N•. • •r. .a •r arira Olt ■. .N .r Isit: f u�■i N ■:�■ rrr * N 41 t� ar s=: • !�r � i • "• rr =" ■ i.: as a as sf t r r�siii � •• �fiiif i:i i\�iria " ii isasiffi aria ! r • • •fri� • • • _ sma.i saw as a a an • it / Nt�: A MW so t ■ar:•'■�a :i�•:rss• an is �■r. �. qa a t" r.�i•aars' •rai_: us e r�iNsr � imsas _22i a �. i=1N■:r rari'�iis as* isentias �ps■ira as i..a■ •.ir■s .a• rrNayr j.�jjuyp�� •�Is#• awe �_- s•.ar. lafaN � iilU..aa ar. aaa r •awe■ an .r. • ■r r US N as= aasi1jla�i1iiiiiH'i'=s■N�i.1'i��;=. s$�i � .. rr: s as no .::: .:::ii ■ ■■ s\ owes N • a he is,! j �ii; rr• "_ •iis •� •:::: own ME a •• . as:ON .: ii =. :i •�'iii. a::i:i .iai=:�:�iii i �i a s•s = . \ • as In :: fa l l:ii=i siii:i :::is:iiinn � ia•r iism • s • " __ aia�•i •1: .•1ii::sii::101ma i . we=': s«q. $ i 1• ■ i .:�• N•f i_s_ ..��� ■.•ff�a\N•.N...at IN Nsi_s s``f N.�aa."/ a age SEE a�■�.■•• N a • jif'ri• MEN son j� Him • �• :� :i=i : == asr/::ii::isi:::::::=a:i::. f:_:=S:�:a::age a 0 a :■\«: r! • agar� l i.. =taM:ia � : ss. :•_ss_�•i•:N.•/NaN...a/=.■N■N\a■�• •aaiN•.1r■a•4:11 i:11111111 iiijLq �!� 1� ! _``•.•\.a/•/• ■■Mf•Nr■ ■•.■a f..r i•ii. .•as . •■■ \.■ larva =a■\as•r s a � __==="=ii=='r•'i=�=;:''adisr:=:=!!i i�:•fi ii::�i:=i':::::=::::i:i==:ss::i:i::i=:$i'�i='i=i i=ago No'�'iiii�=iii�=a� ��"ri ■ '.y 3 '�ii'�'$ s $•ss.•••$i.■■ss _ _ _ a : says ss $ := sas $$Y$ "■ = =$■rs 1 • ■•. • .• • •a...••\...•.•••.•ff•...r■ •..•\.•.• •.a/• N• f.i af.. i o• i • .■' •r■ �ritai _ ■ a• on is a==ll=:=:�i::s:s=====__ _ =ii: •==::s::=::_::::::•si ::::s::HURIMIONSOHn_:::_::: :0:=:s=::•=wassommusausii::==iii::�=s"::s:":ii:� it �ii"iitisi i t ' ■r •' r ' 1 t.s /a.■ r• • . s.s. .i=....._• s:: sis ii i s s = ss $sass o :aia=..$$• iss$si•: 0 sm sae . 1■ a•fN ■ • ••r•s ■•• ■•■ ••■ a.f •..•\f•••fr. ■•a...•■r•.••r•• ■r..• •.\••.•.• •.■ r .•■rraar • .. a i a • • .r one �. �.• :: �$ ; j_;::: __: ::_j: :_:: a:: ..................... ..... ..■• HUHH=r ■•■ =:r �s' owe" $i•" ...�r.� •= a s $ t•�•s� : . s s : • •. .__■ i Hill .s ■si";■ a::: siti:::�•s�::;s:s; asi s f•� •' r:i a a=a�+i= Ss:• i�i.•.oHN. .••■■::::.:l::::.a■pas�f•s■.:i•.•:■=■i.•r\1==.iaia:is1.■s=:•if�silus'd a - s=.i.: ='::i ;;::i==•tis� c3lim::a:i::=;:: S Sias::::3aii:=::a�=::::::::::::::::::::m=i:::::C:=SMI: :=:�mlis�� •• = i a =fit:=S s ss.a.........:..ssis..Nss•a$s;■:asisi$sesss� •s• �:■\.::ii...=:arri: •••__:•• ■f•t••.• f • •.•■ ■■.•.••a..r•a•i\ ••■■soap. •• •\■ ■..r .r i■■ •• t • a■ s=s•s =:....�...� ••s..•.s:.N.si•af•ss• /•.•rasa:.r■..•.•.s..••i.s.r•s.•.frts.n� ■iir■ =ss • !s a '• �" ! �.�• .�:: ..:• I••:;••t: • fl:; .s •f• .. s�i.f/.sp•• •■afrfsf. /sass. ... sass.. i= $i �$$ �� � ;s�• "a ..• s::==.s:::==ss e's'ses:ee's:ge e$e:eess:6:e's:e=:$ts=es'sa::=i:s ss .1111s:$��s=3:s isaNr $sass: i :• _!!•.•__::;::__:•;_::::__:••:_=••::s ::::;::::::'::::'::;;::::`:';::=;s:i:;:s::i: •••:= s:i�ssg:i i3ls"is =is.r .i:.sss1: 1,11:_�•woma:_' � •i •i=:�a•.■i:is/p:ss••a. t•isstai:=sS$•sC•t■t=■aai=rr•:■i\■a■■a:■i•■assist/•■;■==t$• �s•=■.si=■r=iQ:■:a i"iiisa■:s= .s:.. ::s:.:ss:a.•.:::.ss =:s::.::::.•:s:.: ::::::..:s:.::s:Ns::.::::...ss:$ :...ss :$i. $as : Ni .. sass.. --------------::l:;:uses=es:;:------: : ::s- :=-s:g::::::: r E . 1 TOWN OF SOUTH WINDSOR BUILDING PERMIT Date Aug. 24 , 19 81 Fee Paid $. .36.00 Eat. Value $.6,•000.00 Permit N0 12354 on the —aide of Kelly Road Street Street No. 128 Owner Robert Benson Applicant Sabri na Pon1 CERTIFICATE OF OCCUPANCY ISSUED: Date , No. Fee Paid $ CLASSIFICATION In-ground pool w/fence f 1 i t I BUHDING PERMIT N? 12354 OFFICE OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. South Windsor, Conn. AMS-Aft19 81 94is to to Certify, That ssh-v-1�a Pee is hereby granted permission to Inm&round Fool 201 x 369 w/f enc.e at estimated value of s „00 on the side of 12 8_1 a.-3-ijx R a-a Street on land owned by Rohart. ACU MNA Said Worlr to be as described in Application No. and to conform to specifications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH WIMSOR. Issued Aug- . 2 4 .�� 19 810 ; &i I g Inspector. I Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costs and damages which it shall sustain, or be compelled to reason therefor." 7 7ya-7.3e* - INSPECTION REPORT Permit # r—Y Job 1 Footing 2 Foundations ' 3 Framing 4 Wiring O�6� 5 Plumbing 6 Heating 7 Lathing 8 C.O. 7520 ELECTRICAL APPLICATION 1 Application No. 8632 on the side of Ke 1 ly Road Street Street No. 128 0,,,11 , Robert Bbnson Electrician Homeowner FILED IN OFFICE OF The Building Inspector Sept. 2 19 81 INSPECTION. "�-No Electrical Work shall be started until a Per- mit is granted by the Building Inspector. 1n New Buildings no wiring shall be started until the plumbing and heating pipes, and the fire stops (if of wood) are installed, without a special permit from the office of the Building Inspector. APPLICATION FOR PERMIT TO DO ELECTRICAI. WORK. 1 No. .........8.632............. Permit No. . 7.5.2.0... . . . TO THE BUILDING INSPECTOR of the TOWN OF SOUTH WINDSOR, CONN. J.. . . hereby make application tq perform Electr cal WorK according to detailed description below. All provisions of the Rules for Electrical Installation, Section 48, Building By-Laws, shall be complied with whether specified herein or not. South Windsor, Conn., 4/1 19 0l Sign here Jl. `.... ...... Address ! ` . ..��._......... ..._.... Location 112.`.4...,��%�. . .��!�",� . ...-,. Side of .. ...... ... ........ ............................... Natur of Building `�11??�r� �a How many stories . . ..... ...... ..... New or old Building How many families .............................................................................._......... Kind of Installation .. How many Stores .. .............................................................................................. Owner ........ ........ .... ..... Address ,...._.._......_._.._...... Architect Address .. .. .............. . ......................................... Builder Address Address _._._..... _.... .... Electrician .. ... .... ... . ........ .. Address .. .. . ... ................................................................................._....._....... ., Size of Main Wires J.0.................................... No. of Light Loops .. .. No. of Heat Loops . No. of Power Loops ................... No. of Light Outlets .... .... ... No. of Heat Outlets . .. No. of Power Outlets ............... . ........... Nog of Light Circuits ... ... ... . .... ..... No. of Heat Circuits . No. of Power Circuits .. ...... .. ... .. No. of Sockets No. of Heat Receptacles No. of Motors No. of Panels .................................. . . . . Size of Heat Circuit No. of Power Receptacles No. of Switches .. ...... . .... ... ... . Total Wattage Size of Power Circuit . . Total Horsepower No. of Straight Electric Fixtures ..... . No. of Combination Fixtures ... . ..... .. No. of Receptacles ......................... ........ .......................... ... . No. of Cord Drops .................. . ...... .............. .. ........... . ......... .. Remarks: For other kind of Installation .. . 46.f../4F_.1....//......... . .... ..... .... . .. ........ .. ... ........ ............... ........................................................................................................... ....................... .................................................................................................... ......... .... .. ... .. ............................................ ........................................ ................................. ...... ................ _..... ......................................................................................... ................................................... ........................... ....... .... ...... ................................................ ...... . ............. . ............................. Estimated Cost .... ............ .................. 8228 ELECTRICAL APPLICATION Application No. 9334 on the side of Kelly. Road Street Street No. 128 Owner Robert Benson Electrician M &M Electric FILED IN OFFICE OF The Building Inspector Jan. 11 19 84 INSPECTION. r&No Electrical Work shall be started until a Per- mit is granted by the Building Inspector. In New Buildings no wiring shall be started until the plumbing and heating pipes, and the fire stops (if of wood) are installed, without a special permit from the office of the Building Inspector. Electrical Permit No. jP2--:1-k............... Master License No. ....................... TOWN OF SOUTH WINDSOR Building Permit No. ..00 ....................... BUILDING DEPARTMENT Date Filed .................................... Date Final Approval ........ .. . . ........ .............. APPLICATION FOR ELECTRICAL WORK Electrical Inspector JOB LOCATION: 2-8-- ffe-Pry .1rd I .... . ............................ J 0 B OWNER: .1?0h.-e.r..T......... kj- .............................. Sideof Between .. . .... . ............. ........ ....... and ................................................................................ Name of Building Owner 930beeT. ................ . Address f. . Aelle-x..... Ird .... ............ .......... ...... If work is for Lessee—Give name Address ................ ... ..... ........................ ....... .. . ......... ...... Building now occupied as (unless new) No. of family units now . .... ........ Building to be occupied as .... .. ... Number of family units to be ..... . .......... .. Is this work included in a Building Permit? Permit Fee .. ........ ....... .. ................................... ............ ...... ........... M )akrt)i-IC (G3�i2 (If no Building Permit) 1-u Permittee IVA Business Address Telephone kY4-#652 COST OF INSTALLATION: .............. ........................ TO BE FILLED OUT BY PERMITTEE TO BE WIRED EXISTING APPLIANCES Number of light outlets to be installed Number of convenience outlets to be installed Number of present Appliance Circuits .. .. ..... ........... ................ Number of switches to be installed Do these include Range ❑ Water Heater E] Number of appliances to be installed (as listed below) Dryer Ej Air Conditioner ❑ Oil Burner E] TYPE RATING NO. Dish Washer E] Gas Burner ❑ Range . . . . . . . . Well Pump E] Elec. Heaters ❑ Range Top . . . . . . Oven . . . . . . . . REMARKS: Water Heater Clothes Washer . . . . Clothes Dryer . . . . . Dish Washer . . . . . . Air Conditioning Motor . . Oil Burner Motor . . . . Gas Burner . . . . . . Circulator Motor . . . . Attic or Large Fan . . . Well Pump . . . . . . Electric Heat . . . . . Other . . . . . . . . I Number of new Lighting Circuits . . . . ........... ............... Number of new Appliance Circuits . . . ............................ Number of Heating Circuits . . . . . . ............................ Number of Motor Circuits . . . . . . . ...........—...-- Size of present service ......... ... ................................................ Size of service to be . . ... . ....... ....... .................................... AL Burl ng SPEC IONS: f v-, 14 s3 APPLICATION FOR BUILDING PERMIT Plumbing HVAC 128 KELLY ROAD Date: Sprinkler Electric Estimated Costs 3 3 73. da Zoning 20055 Permit Fee$ Affidavit NO. Occupancy Fee $ Eng. Dept. Fire Dept. COMPLETE RED BOXED AREAS. Total Fee $ b� Health Dept. TYPE OR PRINT ONLY Approved for CO: SIGN ON REVERSE SIDE. (Additional Cost) $ TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The and rsigned, hereby applies to do work according to the following specifications: Job Location f Lot No. Side of Street -&-Zone Applicant ��4 4- Tel. # cLl 30ffKk&& Address 1 611 _Zip L 0 7 y Lic.# STR T CITY STATE Owner ddressJ42 ���r � V-) Architect Address Size New Area: Ft. Front Overall Ft. Deep Overall Total Area #Garages Lavatories Size of Lot Dist. from Street Line Bathrooms Rooms 1 st 2nd 3rd Purpose of this Permit 3 0 `� 3 2 AAC City Water ❑ Well ❑ Septic ❑ Sewer ❑ Use Group Construction Type Approved by Date 4"�9'"�-2 BD1A 11/88 I h reby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zone in which this building and its use is allowed. Signed I hereby apply for a Certificate of Occupancy for the work described in this application for permit. Signed —DO NOT WRITE BELOW THIS LINE— INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation Plumbing Permit# Inspections: HVAC Permit# Inspections: Electrical Permit# Inspections: Sprinkler Permit# Inspections: Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- 92-20055-B 5,393 B1O FINAL 03/16/93 JFH A CLOSE OUT Total Est Value 5,393 j Bectt# APPLICATION FOR BUILDING PERMIT Plumbing# 128 Kelly Road Date: 7 Z O HVAC # �. 26901 Sprinkler# FOW Estimated Cost $ D ©— Building 370-e-,,� COMPLETE RED BOXED AREAS Permit Fee $ ��ng ��V 29TYPE OR PRRIT ONLY Occupanty Fee $Affidavit SIGN ON REVERSE SDE Appr.for CO. Total Fee /3�• TO BULI)M DPARTM NT,TOWN OF SOUTH WNDSOR,CT (Additional Cost) $ The undersigned hereby applies to do work according to the following specificatiorm Job Location /a Ie, l Iv Kd Lot No. Side of Street Zone Applicant Tel# ya--T5 - Address 7 o I _ 5I rm LA)I'O d�o r- Zip Co O Lic.# s3 Oa 6 3 Owner _Le,/0200-2 - Address ,�2e4 Nc- e- - Architect Address Sq.Ft.N w Area: lst Fl. 2nd Fl. 3rd Fl. Total New Area #Rooms #lavatories #Bathrooms #Garages Purpose of this permit: 9 Q- " y-►rN1 0 e i—b ='t,3 -- 1"e^��?c'A) l P Pi r 0 ry, e ✓CW C ✓ ` �1 J,) d LjM City Water ❑ Well ❑ Septic System ❑ Sewer ❑ Ins. H.O. S.P. Cert._� Area Basement Garage Approved by _t rl Date vv Use Group Construction Type — Rev6ed 1197 I hereby agree to conform to all the requirements f the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in this building and' use is alkwved. Signed I hereby apply for a Certificate of Occupancy for the work described in this application for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Inspection / Approval Date By Appl Code Description Due Whom Code CommEnt ------------------------------------------------------------------------------- **-26901-B 9,800 B10 FINAL 08/30/00 JFF A B10 FINAL 08/30/00 JFF A CLOSED OUT. DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR Q �2 BUILDING DEPARTMENT APPRO 1540 SULLIVAN AVENUE Bldg.Permit# b 66 644-2511 ext. 230 ate Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: 14t LL P--D $0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= $13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT PZA)3 A\?- S EQ- ICE LL Cr APPLICANT ADDRESS 5 N E I W, P-D -PO QQ 141`"') VEQNn N3 APPLICANT PHONE# OWN S OWNER L A�J QENCE W 5O RDA- q� OWNER ADDRESS I /`JO-/LLaD 2nrd AQ OWNER PHONE (r 0 6(0 9 C WD ESTIMATED COST$ SS O O �— �] _ * U IS THIS A CONTRACT COST? )2-Yes 0 No FEE ENCLOSED$ ?g TYPE OF JOB: SpR.CO 14 New Installation al Aft Alteration/Addition/Repair 12C,-oL a Revised 8/99 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: CHEATING C3iRESIDENTIAL �A/C ❑COMMERCIAL ❑ VENTILATION ❑INDUSTRIAL HEATING ❑STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) CA221EP- C()tjDe.JSr - y PL9rNACV rB�M��Pdf�O ,f m kA-gLq, a Stee,e- GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL ❑OIL—GPM OIL TANK LOCATION :❑INSIDE❑ OUTSIDE CAPACITY CqGAS—INPUT LPG TANK CAPACITY �- ELECTRIC—KW g AIR CONDITIONING p DESIGN TEMP.OUTSIDE ! OF INSIDE�Q OF DIFFERENCE p� OF TOTAL HEAT GAIN(BTUH) a c (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) ,,Aej2 AL s TONNAGE COOLING CAPACITY(BTUH)-��- VO VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) 400 FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK &?c!S 771%t(o ICE/rA)A-C e- pv C ti—,-2 P,- (_ THE UNDERSIGNED HEREBY APPLIES tOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. © 0 389/y� IdAe� CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE DESIGN: WINTER, 75 DEGREES DIFFERENCE SUMMER, 25 DEGREES DIFFERENCE JOB: BENSON - RESIDENTIAL CALCULATION HTM HTM AREA BTU/HR BTU/HR- .DATE: 05-04-2000 HEAT COOL OR # LOSS GAIN BASEMENT - UNHEATED NO LOSS OR GAIN KITCHEN, SOUTH & EAST HEAT COOL VALUE LOSS GAIN 1 WINDOW DOUBLE GLASS 48 X 84 IN, NO SHADE 43.4 40.0 28 1216 1120 ROOF/CEILING WITHOUT VENTILATION, R19 INS 3.6 2.0 240 873 480 HARDWOOD FLOOR, NO INS OVER ENCLOSED SPAC 11.7 0.0 240 2799 0 WALL 20 X 8 FT, FRAME OR VENEER, Rll INSUL 6.7 2.6 132 8SO 3•13 1 WINDOW DOUBLE GLASS 48 X 84 IN, NO SHADE 43.4 74.0 28 123.6 20-72 WALL 12 X 8 FT, FRAME OR VENEER, Rll INSUL 6.7 2.6 ES 458 177 INFILTRATION, LOSS 1.2 AC/HR GAIN .5 AC/HR 56.0 7.9 56 3135 440 LATENT HEAT INFILTRATION ALLOWANCE 0.0 7.4 56 0 43.3 ALLOWANCE FOR APPLIANCES AND MOTORS 0.0 2.0 600 0 1200 DUCT IN UNCONDITIONED SPACE 0.15 0.15 SUB 1588 875 TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 228 12175 6707 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES: 2 BRANCH DUCT - (6 IN ROUND) OR (7 IN OVAL) OR (3-1/4 X 10 WALL STACK REQUIRES: 2 #661 14 X 4 SIDEWALL REGISTER OR 2 #411 4 X 12 FLOOR DIFFUSER OR REQUIRES: 2 #16 8 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES: 2 #650 10 X 6 INCH RETURN AIR GRILL, OR TWO 3-1/4 X 14 IN--WALL RETURN LIVING ROOM, SOUTH & WEST HEAT COOL VALUE LOSS GAIN 2 WINDOWS DOUBLE GLASS 48 X 60 IN, NO SHAD 43.4 40.0 40 1738 1600 ROOF/CEILING WITHOUT VENTILATION, R19 INS 3.6 2.0 216 786 432 HARDWOOD FLOOR, NO INS OVER ENCLOSED SPAC 11.7 0.0 216 2519 0 SENSIBLE GAIN FROM 2 PEOPLE 0.0 2.0 250 0 Soo LATENT GAIN FROM 2 PEOPLE 0.0 2.0 200 0 400 WALL 18 X 8 FT, FRAME OR VENEER, Rll INSUL 6.7 2.6 104 701 270 WALL 12 X 8 FT, FRAME OR VENEER, Rll INSUL 6.7 2 .6 96 647 250 INFILTRATION, LOSS 1.2 AC/HR GAIN .5 AC/HR 72.2 9 .6 40 2887 385 LATENT HEAT INFILTRATION ALLOWANCE 0.0 9.0 40 0 362 DUCT IN UNCONDITIONED SPACE 0.15 0.15 SUB 1392 516 TOTAL BTU BEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 149 10670 3953 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES: 2 BRANCH DUCT - (6 IN ROUND) OR (6 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES: 2 #661 12 X 4 SIDEWALL REGISTER OR 2 #411 4 X 10 FLOOR DIFFUSER OR REQUIRES: 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES: 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN R ,MASTER SUITE, WEST & NORTH HEAT COOL VALUE LOSS GAIN 1 WINDOW DOUBLE GLASS 24 X 48 IN, NO SHADE 43.4 74.0 8 348 592 , ROOF/CEILING WITHOUT VENTILATION, R19 INS 3.6 2.0 132 480 264 HARDWOOD FLOOR, NO INS OVER ENCLOSED SPAC 11.7 0.0 132 1540 0 SENSIBLE GAIN FROM 2 PEOPLE 0.0 2.0 245 0 490 LATENT GAIN FROM 2 PEOPLE 0.0 2.0 155 0 310 WALL 12 X 8 FT, FRAME OR VENEER, Rll INSUL 6.7 2.6 88 593 229 1 WINDOW DOUBLE GLASS 48 X 84 IN, NO SHADE 43.4 25.0 28 1216 700 WALL 11 X 8 FT, FRAME OR VENEER, Rll INSUL 6.7 2.6 60 404 156 INFILTRATION, LOSS 1.2 AC/HR GAIN .5 AC/HR 48.1 6.9 36 1732 247 LATENT HEAT INFILTRATION ALLOWANCE 0.0 6.5 36 0 233 DUCT IN UNCONDITIONED SPACE 0.15 0.15 SUB 947 402 TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 104 7260 3080 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES: 2 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES: 2 #661 10 X 4 SIDEWALL REGISTER OR 2 #411 2-1/4 X14 FLOOR DIFFUSER OR REQUIRES: 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES: 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN BED ROOM # 2, NORTH HEAT COOL VALUE LOSS GAIN 1 WINDOW DOUBLE GLASS 48 X 84 IN, NO SHADE 43.4 25.0 28 1216 700 ROOF/CEILING WITHOUT VENTILATION, R19 INS 3.6 2.0 88 320 176 HARDWOOD FLOOR, NO INS OVER ENCLOSED SPAC 11.7 0.0 88 1026 0 WALL 8 X 8 FT, FRAME OR VENEER, Rll INSULA 6.7 2.6 36 243 94 INFILTRATION, LOSS 1.2 AC/HR GAIN .5 AC/HR 41.3 5.9 28 1155 165 LATENT HEAT INFILTRATION ALLOWANCE 0.0 5.5 28 0 155 DUCT IN UNCONDITIONED SPACE 0.15 0.15 SUB 594 170 TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 63 4554 1305 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES: 1 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES: 1 #661 10 X 4 SIDEWALL REGISTER OR 1 #411 2-1/4 X14 FLOOR DIFFUSER OR REQUIRES: 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES: 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN BATH RM # 11 NORTH HEAT COOL VALUE LOSS GAIN ROOF/CEILING WITHOUT VENTILATION, R19 INS 3.6 2.0 64 233 128 HARDWOOD FLOOR, NO INS OVER ENCLOSED SPAC 11.7 0.0 64 746 0 EXHAUST FAN, 45 CFM WITH .50 45 40.4 13.0 45 1820 585 WALL 8 X 8 FT, FRAME OR VENEER, Rll INSULA 6.7 2.6 64 431 166 INFILTRATION, LOSS 1.2 AC/HR GAIN .5 AC/HR 0.0 0.0 0 0 0 LATENT HEAT INFILTRATION ALLOWANCE 0.0 0.0 0 0 155 ALLOWANCE FOR BATHROOM COMFORT 0.2 0.0 3230 646 0 DUCT IN UNCONDITIONED SPACE 0.15 0.15 SUB 581 132 1 t TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN . ,dFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 62 4457 1011 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES: 1 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES: 1 #661 10 X 4 SIDEWALL REGISTER OR 1 #411 2-1/4 X14 FLOOR DIFFUSER OR REQUIRES: 1 #16 6 IN ROUND CEILING DIFFUSER OR 1 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES: 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN DINING ROOM, NORTH & EAST HEAT COOL VALUE LOSS GAIN 1 WINDOW DOUBLE GLASS 48 X 84 IN, NO SHADE 43.4 25.0 28 1216 700 ROOF/CEILING WITHOUT VENTILATION, R19 INS 3.6 2.0 99 360 198 HARDWOOD FLOOR, NO INS OVER ENCLOSED SPAC 11.7 0.0 99 1155 0 WALL 9 X 8 FT, FRAME OR VENEER, Rll INSULA 6.7 2.6 44 297 114 1 WINDOW DOUBLE GLASS 48 X 84 IN, NO SHADE 43.4 74.0 28 1216 2072 WALL 11 X 8 FT, FRAME OR VENEER, Rll INSUL 6.7 2.6 60 404 156 INFILTRATION, LOSS 1.2 AC/HR GAIN .5 AC/HR 23.6 3.4 56 1320 192 LATENT HEAT INFILTRATION ALLOWANCE 0.0 3.2 56 0 181 DUCT IN UNCONDITIONED SPACE 0.15 0.15 SUB 895 515 TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM @ RECOMMENDED MAX VELOCITY OF 600 FPM 134 6863 3947 FOR FORCED AIR HEATING OR AIR CONDITIONING: REQUIRES: 2 BRANCH DUCT - (5 IN ROUND) OR (5 IN OVAL) OR (3-1/4 X 8 WALL STACK) REQUIRES: 2 #661 10 X 4 SIDEWALL REGISTER OR 2 #411 2-1/4 X14 FLOOR DIFFUSER OR REQUIRES: 2 #16 6 IN ROUND CEILING DIFFUSER OR 2 #24 6 X 6 INCH SQUARE DIFFUSER REQUIRES: 1 #650 10 X 6 INCH RETURN AIR GRILL, OR ONE 3-1/4 X 14 IN-WALL RETURN WHOLE BUILDING LATENT GAIN LATENT HEAT GAIN FROM ALL SOURCES 2209 SYSTEM DESIGN: REQUIRED SUPPLY TRUNK DUCT IS 20 X 8 REDUCED 2 INCHES EVERY 30 FEET REQUIRED RETURN TRUNK DUCT IS 22 X 8 REDUCED 2 INCHES EVERY 30 FEET IF CFM OF SELECTED AIR HANDLER IS GREATER THAN 800 INCREASE DUCT SIZE FOR HUMIDIFICATION SYSTEM TO MAINTAIN 35% RH AT 70 DEGREES: REQUIRED HUMIDIFIER TO HAVE AN EVAPORATIVE CAPACITY OF 5 GALLONS PER DAY GRAND TOTAL BTU HEAT LOSS AND SENSIBLE HEAT GAIN CFM LOSS GAIN CFM AT RECOMMENDED MAXIMUM TRUNK VELOCITY OF 1000 FPM 740 45979 20003