Loading...
HomeMy WebLinkAbout103 Kebalo Lane . Bectric# 1-7 Y33 APPLICATION FOR BUILDING PERMIT Plumbing# O 1507 103 Keba to Lane HVAC # It 27879 Date: 17-Mary-01 Sprinkler# FINAL APP LS Estimated Cost $ 71,000.00 Building �s'b/ COMPLETE RED BOXED AREAS Permit Fee �Wn '"g D-I U TYPE OR PRINT ONLY Occupancy Fee Affidavit /S-o SIGN ON REVERSE SIDE �►PPr. C / Total Fee �- TO B mw; P4TmEwTowNoFsourHwmsoPcT Additional Costs The undersigned hereby applies to do work according to the following specifications: Job Location 103 Kabao i am 0&b8W&E SRDI Pun 1 Lot No._A Side of Street left Zone SRD Applicant K F PnWdlM LIC Walter Kebalo. Manager Tel# 8804A84446 Address 175 Wheeler RMW,South Win IM Zip 06074 Lic.# 3065 Owner K_F_ Pmpedim LLC Address 175 Wheeler Road, South Windsor(FNA 176 Smith Street) Architect QmM Louis Montana Also.Address 35 Alpine Drive, South Windsor Sq.Ft.N w Area: 1st Fl. 1350 2nd Fl. 0 3rd Fl. 0 Total New Area 1350 #Rooms 5 #Lavatories O #Bathrooms 2 #Garages 1 Purpose of this permit: Build condominium unit per plans and specifications Unit type C Located on the comer of Smith Street and Wheeler Road city Wate Well ❑ Septic System ❑ Sewer;KXX Ins. H.O. S.P. Vor Cert. Area 135Z0 Basement 13 6b Garage 336 Approved by 110- Date -)1 1 k) Use Group K'3 Construction Type SS RwiNd 1197 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which thi permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in wh is ui ing and' al Signed I hereby apply for a Certificate of Occu y f the v=in this application for the permit. Signed 66v'l DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Location of Job: AFFIDAVIT Additional Fee S 52 . 00 II State of Connecticut � ss.South Windsor County of Hartford of �/� L L G Owner Agent for the building erected Contractor under Permit No. 2 7 8 7 9 issued by the Building Departure t of the Town of South Windsor being duly sworn,make oath and say that the actual cost of the completed wor authorized u er sa'd permit 'd not exceed the most current accepted BOCA value of S S gued Subscribed and sworn to before me this day of A.D.20 G� Estimated Cost S 89,644 . Difference: $ 31704 . Notary Public I Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-27879-B 71,000 BO1 FOOTING 05/29/01 JFF A WITH CONTRACTOR KEBALO BROS 3000 CONCRETE P03 ROUGH 08/30/01 CJD A W/PLUMBER B03 FRAMING (ROUGH) 09/24/01 CJD A W/KEBALO E03 ROUGH 09/24/01 CJD A PROTECT WIRE AT SCUTTLE, LIGHT AND ACTIVATION IN ATTIC SPACE PO4 GAS TEST 10/24/01 CJD A W/PLUMBER E01 SERVICE 11/09/01 CJD A W/KEBALO B10 FINAL 11/15/01 CJD A B10 FINAL 11/15/01 CJD A CLOSED OUT. **-11174-H 5,940 **-10807-P 5,500 **-17433-E 3,500 I I Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-27879-B 71,000 B01 FOOTING 05/29/01 JFF A WITH CONTRACTOR KEBALO BROS 3000 CONCRETE P03 ROUGH 08/30/01 CJD A W/PLUMBER B03 FRAMING (ROUGH) 09/24/01 CJD A W/KEBALO E03 ROUGH 09/24/01 CJD A PROTECT WIRE AT SCUTTLE, LIGHT AND ACTIVATION IN ATTIC SPACE PO4 GAS TEST 10/24/01 CJD A W/PLUMBER E01 SERVICE 11/09/01 CJD A W/KEBALO B10 FINAL 11/15/01 CJD A B10 FINAL 11/15/01 CJD A CLOSED OUT. **-11174-H 5,940 **-10807-P 5,500 **-17433-E 3,500 Total Est Value 85,940 Dwelling 1,350 65,178.00 Basement 1,350 19,170.00 Garage 336 4,771.20 Smoke Det 7 525.00 BOCA Value 89,644.20 Difference 3,704.20 �/ � SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 103 KEBALO LANE LOT_# Reviewed By n ' Bering) K.F. PROPERTIES LLC Date Reviewed /� �v OI Approv /Denied 175 WHEELER ROAD,SOUTH WINDSOR,CT Reviewed By le " o (Planning) BP ## 27879 Ph # 648-446 Date Reviewed jda, rove /Denied Date Submitted 00/00/00 ***** FOR C of 0 *** As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1. Approved building permit plan 2. Finish grading per approved / building permit plan 1/ 3. Site work; i.e. trees, shrubs, dumpsters, required parking 4. Utility location; a. sanitary sewer/ /1/c'G-407 ,��/i'G rS �-a,2 /�v1a� /LY/oC� ,Sd Iv b. foundation drain C. electrical & telephone d. water e. D.LhzP 5. Sewer connection charge paid 7_L'01 6. Appropriate certification 7. Bonding l/ 8. Planning & Zoning/ Inland Wetlands Considerations A. Lighting B. Signage Freestanding Wall C. Fee in lieu of Open Space /03(�9Z) /o 51(7Z,93) Sewer Permit No. Pavement Excavation No. COMMENTS: 2 S ,3v�fa'�c. *j4,6r w��w �� is ��� ,llno•��-Sse.,o !3y Z�'[l � � aA- DEPARTMENT DECISION AL PERMIT PERMIT# F APPLICATION FOR ELECTRIC Application is hereby: TOWN of SOUTH WINDSOR _.. BULL DING DEPARTMENT Bldg Permit 1540 SULLIVAN AVENUE 644-2511 ext.230 .ems Application must be printed or typedLocation ofjob.� .*: a',�j„` n tw 4 �. `aW_stiy �.1- adx `'},. _.- ,i _ - VV _ •- _ _ - ^ Kebalo Lane "Wheeler Estates" Street No. T Street Lot No. 9C1tbtjLE Floor Apt.No. Over $1 boo 512.w per - - - - - --- OWNER KF Properties LLC -- - - -- - A. or any firacdon thereof ADDRESS 175 Wheeler Road :µg �. ; South Windsor, CT 06074 oWxERs PxoNE# 644-5124 648-4446 � r `� �' `� APPLICANTKebalo Electric Co. Inc. Waiter Kebalo.ADDRESS 175 Wheeler Road -. - � < south Windsor, c7 06074 - i' !. E6TMATED COST 3 50E1 - _ ` _> , ;•� C. � _ 4 . YES NO , FEE ENCLOSED S 52., ,P0 'TYPE OF JOB: Original . Alteration/Addition/Repair � n Revised 11/95 APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) [;TYPE;OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A X RESIDENTIAL BUILDING PERMIT APPLICATION YES / NO BUSINESS ASSEMBLY CURRENT USE AND OCCUPANCY MERCANTILE EDUCATIONAL FUTURE USE AND OCCUPANCY INSTITUTIONAL FACTORY STORAGE ENGINEER'S NAME PHONE GARAGE MIXED USE ADDRESS CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD Type NMB SIZE OF MAIN FEEDERS AND RATING OF.WIRE USED #3 copper 100 amp NUMBER OF METERS 1 NUMBER OF DISCONNECTS AND RATINGS 1 100amp NUMBER OF PANELS 1 REMOTE DISCONNECT REQUIRED?I5/NO NUMBER OF LIGHT CIRCUITS 5 NUMBER OF POWER CIRCUITS 11 NUMBER OF SWITCHES 2 4 NUMBER OF OUTLETS 3 0 NUMBER OF LIGHT FIXTURES 2 6 7 NUMBER OF HEAT CIRCUITS 0 NUMBER OF A/C CIRCUITS 1 SEPERATE HEAT LOSS AND A/C CALCULATIONS MUST BE.SUBMITTED. DESCRIPTION OF WORK Wire new condo units Approx 1400 sq, ft. or less Including new 100 amp underground service THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CT 104943 E1 Jaw NAME STATE LICENSE NO. TYPE SIGNATLT&OF APPLICANT PHONE NO. 644-512 4 DATE q 17 0O l DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR O --'� BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# 01 644-2511 ext. 230 ADg 7 Date ild' g Inspector Application must be printed or typed ® Location of Job: �/ G/ F EESCHEDULE-$1,000=$13.00 Street No. Street Lot No. 13.00 per$1,000 ny fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRESS /i APPLICANT PHONE# r 660 f6 �S MI N S OWNER 1� �J� AKD P-RC �q< OWNER ADDRESS pt OWNER PHONEro4e C ESTIMATED COST$ '�+ ~ IS THIS A CONTRACT COST? JfOYO�es 0 No Q �J FEE ENCLOSED$ TYPE OF JOB: dSOR,Cp� Jhj�<ew Installation 0 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑YES ❑NO RESIDENTIAL ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL ❑INSTITUTIONAL ENGINEER'S NAME PHONE ❑FACTORY ❑ STORAGE ADDRESS ❑GARAGE ❑MIXED USE CITY STATE ZIP TYPE OF INSTALLATION SIZE OF MAIN DRAIN NO.OF TOILETS Z STYLE < Z NO.URINALS t-- STYLE NO.OF BATHTUBS NO.OF SHOWERS 1 NO. OF LAVATORIES NO.OF CONDUCTORS SIZE NO.OF STACKS L SIZE AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW ❑YES ❑NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER WATER HEATER: TYPE MANUFACTURER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 6)� 7(2 CONTRACTORS LICENSE N TYPE STATE L _ SIGNATURE OF APPLICAN DATE r �� y DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# O < 6 4�f 644-2511 ext. 230 Date Building Inspector Application must be printed or typed FEE SCHEDULE ��d Ql o r �- Location of Job: oefr— $0-$1,000=$13.00 Street No. Street Lot No. - Over$1 000= -- --- $13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT E14 I412 e n 9 F-Zr M fiC.4 4N,'C,kf l Sel2v i'(-eS APPLICANT ADDRESS 10,0 6 OX 10 fry F—AJ Fr e L 0 CT QG 0 9- 3 APPLICANT PHONE# M — 7&3 — 9175'— OWN Se OWNER K r P✓�O�F'/Z J►'CS L L C. q� OWNER ADDRESS 17Co ,T t 71 ry 50, w r o s_ i J OWNER PHONE �6 D— Cv�$� " yy O (r' C ESTIMATED COST$ S O � IS THIS A CONTRACT COST? es 0 No i ICJ FEE ENCLOSED$ �S TYPE OF JOB: SOR.CO 0#*New Installation 0 Alteration/Addition/Repair Revised 8/99 1 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF�SYSTEM: TYPE OF DING: 'HEATING RESIDENTIAL g/C ❑COMMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING ❑ STEAM LOW PRESKRE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) !Ai s—,AC +m,p7)j4—AA_1,���1�1'� (j& rj-4cd f Ll.L 0,Aec Ue&Tr ru44�6v . w r tf GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION :❑INSIDE❑ OUTSIDE CAPACITY ❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) �. Do✓1 cc q n2►4.L 4/( U n#4-S Jtc ew) M tZ 4-P 4 -b 3 TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 3o3 d,k '3 S- 1 C-T CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT C DATE �U RIGHT-J SHORT FORM Entire House Fahrenh it M chanical S rvic Job: 09-17-2001 7 Moody Road,Enfield,CT Phone:1-860-783-5775 Fax:1-860-763-5844 Project • • For: Wheeler Sr. Mw. 'C Unit Kebalo Lane, South Windsor, CT Design Information Htg Clg Infiltration Outside db(OF) -5 97 Method Simplified Inside db(OF) 70 75 Construction quality Average Design TD(OF) 75 22 Fireplaces 0 Daily range - M Inside humidity(%) - 50 Moisture difference(gr/lb) - 37 HEATING EQUIPMENT COOLING EQUIPMENT Make RHEEM AIR CON Make HEEM MANUFAC Trade Rheem Trade Rheem RAKA Series RGRA-04(E,N)MAES RAKA-024J RCBA-2457 Efficiency 93.5 AFUE Efficiency 10.0 SEER Heating input 45000 Btuh Sensible c ling 15960 Btuh Heating output 42000 Btuh Latent coolir g 6840 Btuh Heating temperature rise 51 OF Total coolin 22800 Btuh Actual heating fan 751 cfm Actual coolir g fan 751 cfm H ating air flow factor 0.024 cfm/Btuh Cooling air f ow factor 0.048 cfm/Btuh Space thermostat Load sensible heat ratio 85 % ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btu ) (cfm) (cfm) Foyer 20 2917 725 71 35 Living Room 256 5146 2754 124 132 Bath 48 370 127 9 6 Spare Bedroom 162 3173 2051 77 98 Bedroom W. I. C. 25 111 38 3 2 Master Bath 74 1260 746 30 36 Master Bedroom 270 6773 3242 164 155 Dining Room 147 3737 1097 90 53 Brfst/Kitchen 206 5450 2656 132 127 Stairway/Lndry 86 2130 2267 52 108 Printout certified by ACCA to meet all requirements of Manual J 7th Ed. t wrightsoft Right-Suit R sidentialTM 5.0.28 RSR25708 2001-Sep-1717:25:53 C:Tahmeo-Wheeler Sr.Res.C-untuar Page 1 t i Entire House p 1293 31067 15703 751 751 Ventilation air 0 0 Equip. a@ 1.02 RSM 16017 Latent cooling 2784 TOTALS 1293 31067 18801 751 751 Printout certified by ACCA to meet all requirement of Manual J 7th Ed. ,k wrightsoft Right-Sufte ResidentialTM .t.28 RSR25708 2001-Sep-17 17:25:53 �� C:1Fahmee-Wheeler Sr.Res.C-Unit.rsr Page 2