Loading...
HomeMy WebLinkAbout104 Kebalo Lane .Sectric# t APPLICATION FOR BUILDING PERMIT Plumbing# 1,- <Me 104 Kebalo Lane WAC # 11(7 Dot : 17-May-01 Sprinkler# No. 27880 FINAL APPROVALS Estimated Cost $ 75,000.00 Building cs COMPLETE RED BOXED AREAS Permit Fee WneeriAffidavit D-10 TYPE OR PRIM ONLY Occupancy Fee $ Affidavit SIGN ON REVERSE SIDE 11 Appr.for CO. Total Fee �o TO BLALDM DEPARTM&ff,TOWN OF SOUTH Wll,- ,CT (Additional Cost) $ The undersigned hereby applies to do work according to the following specifications: Job Location lid Kebaln I ane(Wheeler i~r SR Dl Bla 1 Lot No._ A Side of Street left Zone SRD Applicant K_F_ Properties I IC Walter Kebalo= M9na= Tel.# 86 Address Wer Reed. SOO Windsor Zip 06074 Lic.# 3066 Own r K_F. Properties LLC Address 175 Wheeler Road, South Windsor(FNA 176 Smith Street) Architect Gmwv LOWS Montana Ano.Address 35 Alpine Drive, South Windsor Sq.Ft.New Area: 1st FL 1337 2nd FL 0 3rd Fl. 0 Total New Area 1337 #Rooms 5 #Lavatories O #Bathrooms 2 #Garages 1 Purpose of this permit: Build condominium unit per plans and specifications Unit type A Located on the comer of Smith Street and Wheeler Road (�cc es,�i City Watery Well ❑ Septic System ❑ Sewerxxx Ins. H.O. S.P. Cert. Area 133-1 Basement 133-7 Garage 33C-� Approved by S�� Date S yc U( L6 Group C-3 Construction Type 56 Revied 1197 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in whict t is building and its pse is allowed. Signed I hereby apply for a Certificate of OccuDaucy for the work d ibed in this application for the permit. Signed WAIX DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Location of Job: AFFIDAVIT Additional Fee$ — 0 — State of Connecticut ss.South Windsor County of Hartford _ Owner I /J!Ar'E� �� of �/ZO/4�T7&S Agent for the building erected Contractor under Permit No. 2 7 8 8 0 issued by the Building Department of the Town of South Windsor being duly sworn,make oath and say that the actual cost of the completed work autho ' der said permit id pot exceed the submitted estimated cost Signed 40 Subscribed and sworn to before me this day of A.D.20 Estimated Cost$ 91, 640 Difference: $ (2,808) Notary Public Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- _ **-27880-B 75,000 BO1 FOOTING 05/29/01 JFF A WITH CONTRACTOR KEBALO BROS 3000 CONCRETE B03 FRAMING (ROUGH) 09/24/01 CJD A W/KEBALO E03 ROUGH 09/24/01 CJD A W/KEBALO- NEED LIGHT AND ACTIVATION IN ATTIC SPACE B04 INSULATION 10/01/01 GRM A W/CONTRACTOR PO4 GAS TEST 10/24/01 CJD A E01 SERVICE 12/11/01 CJD A W/WALTER B10 FINAL 12/11/01 CJD A W/TOM B10 FINAL 12/12/01 CJD A CLOSED OUT. **-11175-H 7,640 **-10808-P 5,500 **-17434-E 3,500 Inspection / Approval Date By Appl • Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-27880-B 75,000 B01 FOOTING 05/29/01 JFF A WITH CONTRACTOR KEBALO BROS 3000 CONCRETE B03 FRAMING (ROUGH) 09/24/01 CJD A W/KEBALO E03 ROUGH 09/24/01 CJD A W/KEBALO- NEED LIGHT AND ACTIVATION IN ATTIC SPACE B04 INSULATION 10/01/01 GRM A W/CONTRACTOR PO4 GAS TEST 10/24/01 CJD A E01 SERVICE 12/11/01 CJD A W/WALTER B10 FINAL 12/11/01 CJD A W/TOM **-11175-H 7,640 **-10808-P 5,500 **-17434-E 3,500 Total Est Value 91,640 Dwelling 1,337 64,550.36 Basement 1,337 18,985.40 Garage 336 4,771.20 Smoke Det 7 525.00 BOCA Value 88,831.96 Difference (2,808.04) SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 104 KEBALO LANE LOT_## Reviewed By ,( ering) K.F. PROPERTIES Date Reviewed pprove /Denied 175 WHEELER ROAD,SOUTH WINDSOR,CT Reviewed By lanning) BP_#_27880_ Ph_# 648-4446 Date Reviewed Approved/Denied Date Submitted 00/00/00 ***** FOR C of O ***** IV As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A / 1. Approved building permit plan 2. Finish grading per approved ( building permit plan -� 3. Site work; i.e. trees, shrubs, dumpsters, required parking � O \ 4. Utility location; a. sanitary sewer/septic system b. foundation drain C. electrical & telephone U d. water Ve. other 5. Sewer connection charge paid / 6. Appropriate certification 7. Bonding 8. Planning & Zoning/ Inland Wetlands Considerations A. Lighting B. Signage Freestanding Wall C. Fee in lieu of Open Space Sewer Permit No. 72YI— Pavement Excavation No. COMMENTS: �� � DEC 1 2 2U 01 SOUTH WINDSOR PLANNING DEPT. FEP::NION APPLICATION FOR ELECTRICAL PERMIT PERMIT# AP ` : TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Permit# 1540 SULLTVAN AVENUE � k�644-2511 ext.230 nspector a Application must be printed or - Location oT job 104 Kebalo Lane "Wheeler Estates" - Street No. Street Lot Now,; FEE SCHEDULE _ - Floor Apt.No. $O - $1,000 - $12.00 Over $1,000 $12.00 per$1,000 OAR KF Properties LLC or any fiacction thereof ADDRESS 175 Wheeler Road South Windsor, CT 06074 644-5124- 648-4446 OWNERS PHONE# APPLICANT Kebalo Electric C6. Inc. Walter Kebalo ADDRESS 175 Wheeler goad South Windsor, CT 06074 z ES'I'IlViA'I'ED COST _ ,504 C IS THIS A CONTRACT COST 7 .� YES ' NO �C► FEE ENCLOSED $ 5����� TYPE OF JOB: Original Installation Alteration/Addition/Repair ; Revised 11/95 APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A X RESIDENTIAL BUILDING PERMIT APPLICATION YES / NO BUSINESS ASSEMBLY CURRENT USE AND OCCUPANCY MERCANTILE EDUCATIONAL FUTURE USE AND OCCUPANCY INSTITUTIONAL FACTORY STORAGE ENGINEER'S NAME PHONE GARAGE MIXED USE ADDRESS CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD Type NMB SIZE OF MAIN FEEDERS AND RATING OF.WIRE USED #3 copper 100 amp NUMBER OF METERS 1 NUMBER OF DISCONNECTS AND RATINGS 1 100amp NUMBER OF PANELS 1 REMOTE DISCONNECT REQUIRED? S/NO NUMBER OF LIGHT CIRCUITS 5 NUMBER OF POWER CIRCUITS 11 NUMBER OF SWITCHES 2 4 NUMBER OF OUTLETS 3 0 NUMBER OF LIGHT FDnURES 2 6 i 7 NUMBER OF HEAT CIRCUITS 0 NUMBER OF A/C CIRCUITS 1 SEPERATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK Wire new condo units Approx 1400 sq, ft. or less Including new 100 amp underground service THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CT 104943 E1 >0 NAME STATE LICENSE NO. TYPE SIGNATAE OF APPLICANT PHONE NO. 644-512 4 DATE 7 t DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR 10988 BUILDING DEPARTMENT OVER 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 � c� Date ild" spector Application must be printed or typed Locati of Job: ff FEE SCHEDULE ' 0 460 0^40, $0-$1,000=$13.00 Street o. Street Lot No. Over$1,000= $13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRESS 42- ' kEvv) vul cr 0�6 APPLICANT PHONE# ri / 3 .��Z 01 W N S OWNER L OWNER ADDRESS W =�. ��t- �✓�w� �� off' � +� OWNER PHONEX-0Of ESTIMATED COST$ dhow IS THIS A CONTRACT C19SV �Yes 0 No FEE ENCLOSED$ TYPE OF JOB: �SOR.Cps New Installation 00 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A '.RESIDENTIAL BUILDING PERMIT APPLICATION? ❑ YES ❑NO ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL ❑INSTITUTIONAL ENGINEER'S NAME PHONE ❑FACTORY ❑ STORAGE ADDRESS ❑GARAGE ❑MIXED USE CITY STATE ZIP TYPE OF INSTALLATION SIZE OF MAIN DRAIN NO.OF TOILETS STYLE I Z NO.URINALS STYLE NO.OF BATHTUBS ( NO.OF SHOWERS / NO. OF LAVATORIES 2, NO.OF CONDUCTORS SIZE NO.OF STACKS SIZE AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES_�_ KIND t4�r ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW ❑YES ❑NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER WATER HEATER: TYPE MANUFACTURER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. Td CONTRACTORS LICENSE NO. YPE STATE SIGNATURE OF APPLICANT DATE L DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: 'I BUILDING DEPARTMENT AP 1540 SULLIVAN AVENUE Bldg.Permit# Or �j 644-2511 ext. 230 c2 7 Y-0 a-td Building Inspector Application must be printed or typed FEE SCHEDULE `,u e- Location of Job: c� 13 V i ,n �$ 0 $0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= $13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT �=Ja�.1n2 EAJ L4 FT A&JG 441 c A ,S a A V/'tfs X14 c-. APPLICANT ADDRESS V=0, 6 9�K 1 d 9 Y F=4 F,-,eLa c?- oGow 3 APPLICANT PHONE# 8,irO o " 74 3- S r7 OWN S OWNER le, F f ko lockrf-�e -S q< OWNER ADDRESS 14- -S T/2e e I 0 w�' �.T D f r ... OWNER PHONE ESTIMATED COST$ 7,,(a go 0100 �low IS THIS A CONTRACT COST? 00fes 0 No FEE ENCLOSED$ 4V TYPE 2ew B:Installation 0 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF S STEM: TYPE OF B LDING: TING SIDENTIAL A/C ❑COMMERCIAL Cl VENTILATION ❑INDUSTRIAL HEATING ❑ STEAM LOW PRES LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC ❑0' VARRM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) DA S r4L 41D fb o c( R h,�c cwN 64s F,✓Lej n V C, . O f/2t(-T Vci? )rv1(A)4« wlrl!� &eAP44L A/C, PL; M 0 :2 GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL ❑ OIL—GPM OIL TANK LOCATION:❑INSIDE❑ OUTSIDE CAPACITY ❑ GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TO ce,4 M 4 L !qj tl/�, �� �2 td�t�,�-, M/AI R.4 J6 4 6 3� TONNAGE_3 COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) 6y 'n 7`l-A c t/2 ,%5 TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK S O eHd UPI , THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. '3 u3 CT CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE Z --RIG - TTFOEM-- . Entire House Fahrenh--it-Mechanical S rvic Job: 09-17-2001 7 Moody R ad,Enfield,CT Phone:14HO-763-5775 Fax:14HO-763-58" Project • • For: Wheeler Sr. Res. 'W Unit Kebalo Lane, South Windsor, CT Design Information Htg Clg Infiltration Outside db(OF) -5 97 Method Simplified Inside db(OF) 70 75 Construction quality Average D sign TD(OF) 75 22 Fireplaces 0 Daily range - M Inside humidity(%) - 50 Moisture difference(gr/lb) - 37 HEATING EQUIPMENT COOLING EQUIPMENT Make RHEEM AIR CON Make RHEEM MANUFAC Trade Rheem Trade Rheem RAKA Series RGRA-04(E,N)MAES RAKA-030JA RCBA-3765 Efficiency 93.5 AFUE Efficiency 10.0 SEER Heating input 45000 Btuh Sensible cooling 19740 Btuh H ating output 42000 Btuh Latent cooling 8460 Btuh Heating temperature rise 38 OF Total cooling 28200 Btuh Actual heating fan 1004 cfm Actual cooling fan 1004 cfm Heating air flow factor 0.031 cfm/Btuh Cooling air flow factor 0.053 cfm/Btuh Space th rmostat Load sensible heat ratio - 86 % ROOM NAME Area Htg load Cig load Htg AVF Clg AVF (ftz) (Btuh) (Btuh) (cfm) (cfm) Foyer 85 3955 934 121 50 Bath 72 140 1200 4 64 Living Room 324 9061 7088 277 379 Master Bedroom 195 4878 2751 149 147 Master Bath 110 2221 695 68 37 Master W. I. C. 36 399 136 12 7 Dining Room 127 3041 514 93 27 Kitchen 114 3988 2954 122 158 Bedroom/Loft 216 4687 2280 143 122 Bath(Optional) 82 509 229 16 12 Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wnghtsoft Right-SuRe Residentlal*m 5.0.28 RSR25708 2001-Sep-17 20:14:29 ,',CK CAFahmeo-wheeler Sr.Res,D-unit.rsr Page 1 - - — -- hti 1361 xi; entffation air 32879 18780 1004 1004 ui � 0 0 q p�---=-1.02 RSM 19156 Latent cooling_ 3144 TOTALS 1361 32879 22300 1004 1004 r" Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wngl'1t50ft Right-Suite Residential-5.0.28 RSR25708 C:%FahmeC-Wheeler Sr.R s.D-Unft.rsr 2001-Sep-17 20:14:29 Page 2