Loading...
HomeMy WebLinkAbout15 Peachbrook Drive FINAL INSPECTIONS: ,(�, Building j 2 APPLICATION FOR BUILDING PERMIT Plumbing a'� HVAC, 2 Date- 3/311/92 Sprinkler 15 PEACHBROOK DRIV Electric !� " 2 VVEstimated Cost $ 63,000.00 Zoning Permit Fee$ 630.00 Affidavit NO. .19810 Occupancy Fee $ 3.00 Eng. Dept. COMPLETE RED BOXED AREAS. Fire Dept. TYPE OR PRINT ONLY Total Fee $ 633.00 Health Dept. SIGN ON REVERSE SIDE. Approved for CO: 4 V (Additional Cost) $ TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Job Location 15 Peachbrooke Drive Lot No.1-Side of Street -L_Zone DRZ__ Applicant Brom Builders, Inc. Tel. # 889-71 06 Address 207 West Town St. , Norwich, Ct. Zip 06360 Lic.# 500339 Owner grom TREET CITY STATE Builders, Inc. Address Same _ Architect A. W. Mastronunzio Address 36 Pleasant View,Jewett City, Ct. 06351 Size New Area: Ft. Front Overall 261 Ft. Deep Overall 371 Total Area 1,381 sf #Garages 1 Size of Lot 4,799 sf Dist. from Street Line 30' Lavatories 1 _Bathrooms 1_Rooms 1st -3 2nd 3 3rd Purpose of this Permit Construct a 3 bedroom single family dwelling City Water Well 0 Septic 0 Sewer 10 Use Grou Construction Type t Approved by A&- Date s BD1A 11/88 I h reby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinanc s of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zone in which this building and its use is allowed. Signed zwe , k I hereby apply for a Certificate of Occupancy for the work described in this application for permit. Signed- .21t,� —DO NOT WRITE BELOW THIS LINE— . __ INSPECTION RECORD Footing j}� `Z Framin �� , �� II ,r$, Z 7a V Foundation' 2- Fireplace/Chimney Insulation cS >F•D 4(,s74L Plumbing Permit# Inspection-s�� [.. � HVAC Permit# Inspections. dX !� 1 [� 1 -e v"- 9-74 40 .2f t vie. ,' Electrical Permit# Inspections: Sprinkler Permit# Inspections: Location of job p AFFIDAVIT Additional Fee .. .-. ..,. State of Connecticut s_ �r►�Sor/Ci� SS. County of Hartford / I.I'!1 ".. �`S !'�✓'''�"'�...................of !6 ` '�'✓.....''.. s CA gent for building erected under f Qf Contractor Permit No .....!..l. l.0.......... issued by the Dept of Building of the Town of South Windsor being duly sworn,make oath and say that the actual cost of the completed work authorized under said permit was.. 1 ••h o f•• C zllv Signed ............... Subscribed and sworn to before me this ...........q............day of ........ ........... A.D.19 Estimate Cost:S 72 , 5z0 ........ ... I..... ..... ... . Difference: $ Notary Public co_v '�' Nora. CERTIFICATE OF OCCUPANCY CHECK LIST Applicant Brom Builders Certificate of Occupancy Address Bldg. Permit No. Lot No. 15 Ppanhhrnnke Driv, Date Reviewed Project PRAC'_URRnoxy- Reviewed By Date Submitted 6-9-Q2 Approved/D As required in the Zoning Regulations, no Certificate-of-Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1 . Approved building permit plan. 2. Finish grading per approved building permit plan. 3 . Site work; i .e. trees, shrubs, dumpsters, required parking. 4 . Utility location a. Sanitary sewer -2-AD b. foundation drain c. electrical & telephone d. water e. other 5 . Sewer connection charge paid. 6 . Appropriate ro riate certification 7 . Bonding 8. Planning & Zoning Sewer Permit No. Pavement Excavation No. COMMENTS: BUILDING PERMIT CHECK LISTApplicantBr'om Builders, Inc. Building Permit No. f Address 207 West Town Str Norwich CtDate Submitted ) Lot No. 15 #15 Peachbrook Drive Reviewed by Project Peachbrook Subdiv Date 2/p ZT Z In accordance with the Subdivision Regulations, p for to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include : Approved Denied N/Aipo 1. Name, address & phone number of owner/ applicant. U* 2. Name, address & phone number of plan preparer. 3. Zoning information - i.e. zone, open space, fl oodway, etc. 26 4 . Plot plan at 1" _-4re-' scale. a. Subdivision reference, abutting properties, etc. b. Easements of record. Q c. Lot description, bearings, distances, building lines, area, etc. . d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate. e. Building location with dimensions. Elevations of proposed finish floor, garage floor & center line of road at driveway. f. Elevations of gravity drainage systems, sanitary & foundation drain at the house and the street. g. Tentative utility location ga , e ectri , water, etc. h. Title block with name and address of preparer, date appropriate certification, live seal and signature. 5 . Sedimentation and erosion control. 6. Special Planning & Zoning, Inland/Wetlands considerations. (Plans on file w/Town Clerk) BUILDING DEPT. PZC IWA/CC WPCA OTHERS COMMENTS: PERMIT # DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is hereby : TOWN OF SOUTH WINDSOR (A=PPROV DISAPPR VED BUILDING INSPECTION DEPT. 644-2511 Ext. 230 Application must be printed or typed . Date Building Inspector 1 . LOCATION OF JOB kin FEE SCHEDULE No . Street $ 0 - $19000 - $10.00 Floor Apt . No. Over $1 ,000 - $10.00 n p e r $1 ,0 0 0 o r 2 . OWNER �j rn-� -1-e fraction thereof ZO-7 )��f 3. ADDRESS p�� 4. APPLICANT 5. ADDRESS 12, a?)�p��C� 6. ESTIMATED COST 7 . IS THIS A CONTRACT COST ✓ 0 Yes o ` 8 . FEE ENCLOSED $ ` 9 . TYPE OF BUILDING: 8 "ESIDENTIAL COMMERCIAL j 10 . TYPE OF JOB : v"'6riginal Installation Alteration/Addition/Repair j BD 3A 11/88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side ) 11 . LOCATION OF JOB &a,chbron �6eztie, NO . STREET APT. NO 12 . TYPE OF INSTALLATION 13 . SIZE OF MAIN FEEDER 14 . NO . OF LIGHT LOOPS 15 . NO. OF HEAT LOOPS 16. NO . OF POWER LOOPS 4 17 . NO. OF LIGHT OUTLETS 18 . NO . OF HEAT CIRCUITS / 19. NO . OF POWER OUTLET S 5- 20 . NO. OF CONVENIENCE OUTLETS 21. NO. OF HEAT CIRCUITS 22 . NO. OF POWER CIRCUITS q 23 . NO. OF LIGHT CIRCUITS 24. SIZE OF HEAT CIRCUITS 25 . NO. OF MOTORS 26 . NO . OF PANELS / 27 . TOTAL WATTAGE 28 . NO. OF POWER FEEDERS 29 . NO. OF SWITCHES 30 . A/C LOAD 31 . SIZE OF POWER FEEDERS 32 . NO. OF FIXTURES / 33 . TOTAL HORSEPOWER 34 . NAME OF SUBCONTRACTORS AND THEIR TRADES 35 . REMARKS AND FURTHER DETAILS : S 44a 102�42,0 0 v� LICENSE NO. SIGNATURE OF APPLICANT DATE PHONE NUMBER: �- / � _ ^'�`__".o.-�s-T_-." a _.-..-c..e-,�a�-+vv+r-,-.�.*vT-rr�-re•.sr�,�s_?ty, v."` �w••,.s...,--"lA.w'!'�^r-ac T•.c.-+"--�e'�T,'i i\r ^��_—...�;.-„w-a�...� Lot No. Building hermit Temporary Service Permanent Service Pursuant to Permit No. This Certifies that the Electrical Work for which the above named Permit was granted has been duly inspected and is hereby approved. ii G )-c t -e r h DJ Os k, JOwner Electrician Street , t, Building Inspector PE IT N0. oa?y DEPARTMENT DECISION A P P L I C A T I O N F O R Application is hereby : PLUMBING PERMIT TOWM OF SOUTH WINDSOR APPROVED DISAPPROVED BUILDING INSPECTION DEPT. `J q2- J A, 644-2511 Ext. 230 hate Building Inspector Application must be printed or typed. 1. LOCATION OF JOB: FEE SCHEDULE 2. OWNER: 1 3. ADDRESS: 7''7 /6-5- / $ 0 $1 ,000 -- $ 0 .00 Over $1 ,000 - $10 .00 14 d i✓iCk" / 6 per $1 ,000 or 4. APPLICANT: fraction thereof �Ap 5. ADDRESS: W- 6. EST. COST: 7. IS THIS A CONTRACT COST? YES NO 8. FEE ENCLOSED: $�� A �40 1 9. TYPE OF BU DING: RESIDENTIAL COMMERCIAL 10. TYPE OF JO : ORIGINAL ALTERATION INSTALLATION ADDITION REPAID. BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: GENERAL PLUMBING 12. KIND OF INSTALLATION: 13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS 2 STYLE ll�k 15. NO. OF URINALS ---" STYLE 16. NO. OF BATHTUBS 16A. NO. OF SHOWERS / 17. NO. OF LAVATORIES 7 18. NO. OF SINKS 19. DISPOSAL / 19A. DISWASHER I/ 20. NO. OF CONDUCTORS SIZE �� 21. NO. OF STACKS SIZE 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? C 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK? 31. SIZE OF WATER MAIN 31A. SIZES OF WATER PIPING & RISERS 32. REMARKS AND FURTHER DETAILS WATER HEATER 33. TYPE MANUFACTURER TANKS SAFETY DEVICES TEMPERATURE 35. CAPACITY 39. RELIEF VALVE 36. TEST PRESSURE LBS. 40. MANUFACTURER 37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE 38. TYPE 42. MANUFACTURER LICENSE NO. DATE SIGNATURE OF APPLICANT PHONE NO. e7l , f TOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: ,!SA'? (NO. ) TOWN OF SOUTH WINDSOR EST.COST: BLDG. PERMIT NO. gJP, 1540 SULLIVAN AVENUE FEE 6110 SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 $ 0 - $19000 - $10.00 �w $1000 or fraction LOCATION OF BUILDING 1� ��ICr,<,�i7v�/ JrJE� �p�J 5 thereof - $10.00 OWNER ADDRESS TOWN PHONE NO. Ire C � HVAC CONTRACTOR ADDRESS TOWN PHONE NO. TYPE OF SYSTEM: HEATING / TYPE OF BUILDING: RESIDENTIAL A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM OW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM, GAS IN-PUT ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE '--"-OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADWION TOTAL DESIGN TEMP. OUTSIDE (` °F INSIDE YL °F DIFFERENCE rIATION OF TOTAL HEAT LOSS (BTUH) 1, L (HEAT LOSS SHEET MUST COMPANY APPLICfON) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): � - GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE °F INSIDE OF DIFFERENCE F TOTAL HEAT GAIN (BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT): TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) (PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: STATE LICENSE - NAME & TYPE # DATE SIGNATURE OF APPLICANT jam- 5 2 �Z APPROVED DAlt BD 4A 11/88 I = B a R CALCULATION SHEET 1503 (Modern Method) Copyright 1977 by The HydronlCs Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL.A COL.B COL.C COL.D COL.E COL.F COL.G ROOM cc O H L W H L W H L W H L W H L W Design Water Temp. H3A ROOM DIMENSIONS, FT. _ U BTUH per F t of LENGTH EXPOSED WALLS,FT. 4I Radiation Selected WINDOW AND OUTSIDE DOOR AREA U. BTUH BTUH BTUH BTUH BTUH WALL CONSTRUCTION (Table 9, Lino 3 x H) TOTALS RADIATION r76 TYPE OF GLASS FROM LINE 12 SELECTED (Bott m f table used f r Line 5) H CEILING CONSTRUCTIONC ITable 9,L x W) B FLOOR CONSTRUCTIONt(Table9. L xWor Lin. Ft)9 COLD PARTITION CONSTRUCTION F (Table 9, L x H)10 C1 Well(With Openings) C 2 Wells(With Openings) e X 3 Walls(With Openings) or Ent.Hall �.J l — J 11 TOTAL BTUH AT 7OF TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE K — - ----- L -_ COL.A — '_- COL.B COL.H — COL.1 COL.J COL. K COL.L TOTAL BTUH TOTAL OF BUILDING RADIATION 1 ROOM ¢ AT SELECTED O H L W H L W H L W H L I W H L W DESIGN TEMP.- 2 ROOM DIMENSIONS, FT DIFFERENCE 3 LENGTH EXPOSED WALLS, FT. 4 4 WINDOW AND OUTSIDE DOOR AREA U. BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION *INCREASE BATHROOM (Table 9,Line 3 x H) TOTAL 20% 6 TYPE OF GLASS (Butt In of table used for Line 5) 7 CEILING CONSTRUCTION -- - -- tFOR CONCRETE FLOOR ON GROUND OR FILL AT (Table 9, L x WI GRADE LEVEL,USE LINEAR B FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE (Table 9,L x W or Lin Ft.) 9 COLD PARTITION CONSTRUCTION (Table 9,L x H) 10 _0 1 Well(With Openings) 0 CZ 2 Walls(With Openings) X zi 3 Wells(With Openings)or Ent.Hall 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE FORM 1503 This form it available 1r m The Hyd►onict Institute,35 Russo Plate,Berkeley Helphts,N. J 07922 /)"OTECH INC. ROCKVILLE, CONN. 871-7802 Page 1 JOB NAME: THE CAMBRIDGE STREET DESIGN CONDITIONS TOTAL BLDG. HEAT LOSS/GAIN PHONE TOWN CONNECTICUT -------------------------- -------------------------- BLDG : Heating: 80 deg f.t/d BLDG Heat Loss BTU 30,792 Estimator: NOTES: Cooling: 20 deg f.t/d BLDG A/C Gain BTU 28,973 Roos 1 Room 2 Room 3 Roos 4 Room 5 Roos 6 Roos 7 Roos 8 Room 9 Room 10 Roos 11 Room 12 AREA NAME: FAMILY LAY KITCHEN BR 1 BR 2 CLO/BA BR 3 Outside Wall Length; 54.0 12.0 35.0 24.0 25.0 16.5 19.5 0.0 0.0 0.0 0.0 0.0 Outside Wall Height: 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 Sq/Ft S or W Glass 15.0 6.0 15.0 15.0 15.0 0.0 15.0 0.0 0.0 0.0 0.0 0.0 Sq/Ft N or E Glass 28.0 0.0 9.0 28.0 15.0 0.0 15.0 0.0 0.0 0.0 0.0 0.0 No of Doors 1.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Floor Width 13.0 12.0 13.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Floor Length 14.0 8.0 12.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Roof Width 0.0 0.0 0.0 13.0 11.0 16.5 10.5 0.0 0.0 0.0 0.0 0.0 Roof Length 0.0 0.0 0.0 11.0 14.0 6.0 9.0 0.0 0.0 0.0 0.0 0.0 -------------------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- Area Cubic Feet 1,456 768 1,248 11144 11232 792 756 0 0 0 0 0 Gross Wall sq/ft 432 96 280 192 200 132 156 0 0 0 0 0 Net Wall sq/ft 368 90 256 149 170 132 126 0 0 0 0 0 Wall Heating BTU 2,061 504 11434 834 952 739 706 0 0 0 0 0 Wall Cooling BTU 736 ISO 512 298 340 264 252 0 0 0 0 0 S/W Glass sq/ft 15 6 15 15 15 0 15 0 0 0 0 0 S/W Glass Heating BTU 744 298 744 744 744 0 744 0 0 0 0 0 S/W Glass Cooling BTU 186 74 186 186 186 0 186 0 0 0 0 0 S/W Glass Solar BTU 1,200 480 11200 11200 1,200 0 1,200 0 0 0 0 0 N/E Glass sq/ft 28 0 9 28 15 0 15 0 0 0 0 0 N/E Glass Heating BTU 1,389 0 446 11389 744 0 744 0 0 0 0 0 N/E Glass Cooling BTU 347 0 112 347 186 0 186 0 0 0 0 0 N/E Glass Solar BTU 1,120 0 360 1,120 600 0 600 0 0 0 0 0 Doors sq/ft 21 0 0 0 0 0 0 0 0 0 0 0 Door Heating BTU 538 0 0 0 0 0 0 0 0 0 0 0 Door Cooling BTU 160 0 0 0 0 0 0 0 0 0 0 0 Floor sq/ft 182 96 156 143 154 99 95 0 0 0 0 0 Floor Heating BTU 21912 1,536 2,496 0 0 0 0 0 0 0 0 0 Floor Cooling BTU 0 0 0 0 0 0 0 0 0 0 0 0 Roof sq/ft 182 96 156 143 154 99 95 0 0 0 0 0 Roof Heating BTU 0 0 0 343 370 238 227 0 0 0 0 0 Roof Cooling BTU 0 0 0 143 154 99 95 0 0 0 0 0 Lights Cooling BTU 155 82 133 122 131 84 81 0 0 0 0 0 Appliance Cooling BTU 191 101 164 ISO 162 104 99 0 0 0 0 0 People Cooling BTU 177 93 152 139 150 96 92 0 0 0 0 0 Latent Cooling BTU 945 499 810 742 799 514 491 0 0 0 0 0 Ventilation Heat BTU 11376 421 922 596 506 176 436 0 0 0 0 0 Ventilation Cool BTU 941 272 653 801 704 209 591 0 0 0 0 0 Duct Heat Loss BTU 541 166 362 234 199 69 171 0 0 0 0 0 Duct Cool Loss BTU 370 107 257 315 277 82 232 0 0 0 0 0 --------------------- ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ ------ Area Heating BTU 9,560 2,924 6,404 4,141 31514 11222 31027 0 0 0 0 0 Area Cooling BTU 61537 11888 41539 5,563 4,889 1,453 41104 0 0 0 0 0 Area Air Heating CFM 126 38 84 54 46 16 40 0 0 0 0 0 Area Air Cooling CFM 219 63 151 185 163 48 137 0 0 0 0 0 TTL Building. Square feet-> 925 Heating Air Changes/Hour -> 3.29 TTL Building. Cubic feet-) 7,396 Cooling Air Changes/Hour -> 7.83 --------------------------- ------ --------------------------- ----- TTL Building Heating CFM -> 405 Heating CFM per SQ/FT -> 0.44 TTL Building Cooling CFM -> 966 Cooling CFM per SQ/FT -> 1.04 t7E/10/91 HEATINF-i/COOLIHim ETU ESTIMATE: