15 Partridge Lane
FIN Building sP IONS: APPLICATION FOR BUILDING PERMIT Plumbing c1'� HVAC_ cf OC Date. JUNE 26 , 1990 Sprinkler 15 PARTRIDGE r.ANE �� c//�C Estimated Cost $ /d El ctric Zoning Permit Fee $ © f o Affidavit NO. 1 R 6 21 Occupancy Fee $ 3• a4 Eng. Dept J8 MO Fire Dept. COMPLETE RED BOXED AREAS. Total Fee $ -�f, o !3.O0 Health Dept. TYPE OR PRINT ONLY Approved for CO: 1�' 4 SIGN ON REVERSE SIDE. (Additional Cost) $ TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Job Location 15 PARTRIDGE LANE SO .WINDSOR CT Lot No. Side of Street�&_Zone A-3 0 Applicant DART HILL REALTY TN . Tel. # 644-81 37 Address 658 ELLINGTON RD SO .WINDSOR CT Zip 06074 Lic.# 500356 STREET CITY STATE Owner 1 M T ('0NST r 0 TNC Address SAME Architect Address Size New Area: Ft. Front Overall 42 Ft. Deep Overall113 91 Total Area 1892 #Garages 2 Lavatories No. of Families 1 No. of Stories 2 Construction ZX 4 Bathrooms 2 Rooms 1st 4 2nd'I3rd Size of Lot 3 0 , 000 Dist. from Street Line "6 5'1 Dist. from Side Street Line 112311 Purpose of this Permit CONSTRUCTION OF A SINGLE FAMILY DWELLING City Water 12f Well ❑ Septic ❑ Sewer L Approved by Date fa BD1A 11/88 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zone in which this building and its use is allowed. Signed I hereby apply for a Certificate of Occupancy for the work described in this application for permit. Signed —DO Nor WRITE BELOW THIS LINE \�b INSPECTION RECORD Footing Framinn 7 Foundation' �'9'�d �l�� Fireplace/Chimney Insulation �� O Plumbing Per it Inspections: ! �'��� Ira/ G .IF HVAC Permit# d Inspections: Electrical Permit# r/ 4f jt 'T"2 Inspections: C. c; /a1SP-C-1tOki n/, Q #/o1-l'gtfTb ��►ISS�M�.�-,.1.hE:e(,g gM `ti&_, Sprinkler Permit# Inspections: BUILDING INSPECTION DEPARTMENT SOUTH WINDSOR, CONNECTICUT FEE PAID: $3.00 l CERTIFICATE OF OCCUPANCY ZONE: DATED 9/2 5 19 9 d This is to certify that 15 Partridge Lane i 18621 Erected 616-2}- 1 under permit No. -- conforms substantially to the requirements of the building ordinances and the ' zoning regulations of the Town of South Windsor and is hereby approved for occupancy as indicated below. 1 Approved for Occupancy— New single family dwelling -- Lot # 24 i i Use Gr up: R4 C Mr. Type: 5$ Building Official j Notice:If this certificate is lost or destroyed, a duplicate should be obtained immediately from the Building Department. Any change or extension of the use herein approved requires a new certificate of occupancy. CERTIFICATE nr LIST OCCUPANC CHECK LI J J X 16/� Applicant Dart Hill Realty Address Certificate of Occupancy � - 2 4 Bldg. Permit No. Lot NO. (15 Partridge La) Date Submitted Project Partridge Meadow Reviewed By Date As required in the Zoning Regulati no s, no certificate- - shall be issued until grading plans have been complied°f occupancy approved by the Town Engineer. The minimum reuiremwith and inlcude: Q ents shall Approved Denied N/A 1• Approved building Permit plan. --- 2 • Finish grading g per approved / /voc7 g Permit plan. ------ 3 • Site work; i.e. trees , shrubs, -dumpsters required parking 4 • Utility location a• sanitary sewer f b• foundation drain c. electrical & telephone d. water e. other 5 . Appropriate certifica 1 6 . Bonding e RECEIVED 1 3 SFP 1 4 1990 ► 2 Torn of South Windsor Engineering Dept. 3 Sewer Permit No. C Pavement Excay . No. COMMENTS: BUII DING_ PERMIT CHECK LIST v ApplicantDart Hill Realty, Inc. Building Permit No. / �• Address 658 F11 ;ngtnn Rnad Date Submitted Lot No. 9-4 *15 Partridge Lang Reviewed by l�L�-iya Project partri dUp MPadn-w Date In accordance with the Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include : Approved Denied N/A ✓ 1. Name, address & phone number of owner/ applicant. 2. Name, address & phone number of plan preparer. 3. Zoning information - i.e. zone, open space, fl oodway, etc. 4 . Plot plan at 1" = 40 ' scale. j a. Subdivision reference, abutting properties, etc. b. Easements of record. c. Lot description, bearings, distances, building lines, area, etc. d. Contours, existing & proposed, 1 or 2 ft.' interval where appropriate. e. Building location with dimensions. Elevations of proposed finish floor, garage floor & center line of road at driveway. f. Elevations of gravity drainage systems, sanitary & foundation drain at the house and the street. g. Tentative utility location gas, electric, water, etc. / h. Title block with name and address of preparer, date appropriate certification, live seal and signature. 5 . Sedimentation and erosion control. _ 6 . Special Planning & Zoning, Inland/Wetlands considerations. (Plans on file w/Town Clerk) BUILDING DEPT. "- PZC IWA/CC WPCA OTHERS COMMENTS: PERMIT # DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is hereby: TOWN OF SOUTH WINDSOR APPROVED DISAPPROVED BUILDING INSPECTION DEPT. 644-2511 Ext. 230 Application must be printed or typed . Date Bu ' ding Inspector 1. LOCATION JOB t An FEE SCHEDULE No'. Street $ 0 - $19000 - $10.00 Floor Apt . No. Over $1,000 - $10.00 per $l,000 or 2 . OWNER `� Q� Vz � C 0±1� fraction thereof 3. ADDRESSLQ5� E11 ('C)Gjnn t8 c�,c1d-E�g.Q , CT C Q o'7 4. APPLICANT 5 . ADDRESS.qq?: 6. ESTIMATED COST $ O.O c> 7 . IS THIS A CONTRACT COST Y s No 8. FEE ENCLOSED 9. TYPE OF BUILDING: _L,,:-ffESIDENTIAL COMMERCIAL 10. TYPE OF JOB : Original Installation Alteration/Addition/Repair BD 3A 11/88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) tl . LOCATION OF JOB "7' 09 41 Q(�0 NO . STREET APT. NO 12 . TYPE OF INSTALLATION 13 . SIZE OF MAIN FEEDER �('�� (�Q kIC) AL 14 . N0. OF LIGHT LOOPS 15 . NO. OF HEAT LOOPS 16. NO. OF POWER LOOPS�� 17 . NO. OF LIGHT OUTLETS 18 . NO . OF HEAT CIRCUITS_ 19. NO. OF POWER OUTLETS pZ 20. NO. OF CONVENIENCE OUTLETS _21. NO. OF HEAT CIRCUITS_ 22 . NO. OF POWER CIRCUITS_ 23 . NO. OF LIGHT CIRCUITS 24. SIZE OF HEAT CIRCUITS 25 . NO. OF MOTORS 26. NO. OF PANELS / 27 . TOTAL WATTAGEs1`/ �l.J 28 . NO. OF POWER FEEDERS 29 . NO. OF SWITCHES 30. A/C LOAD 31. SIZE OF POWER FEEDERS- A 2- 32 . NO. OF FIXTURES 33. TOTAL HORSEPOWER 34 . - NAME OF SUBCONTRACTORS AND THEIR TRADES 35 . REMARKS AND FURTHER DETAILS : 96CORA 07r3,-90 LICENSE NO . SIGNATURE OF APPLICANT DATE PHONE NUMBER: 22- �0 Lot No, -2-1 Building Permit Terfffir I Temporary Service Permanent Service Pursuant to Permit No. This Certifies that the Electrical Work for which the above named Permit was granted has been duly inspected and is hereby approved. Owner .) Al I c�t� U C, 1 6 Aj Electrician Street - C L f Building Insp or PERMIT NO. �6y5' DEPARTMENT DECISION APPL I CAT ION FOR Application is hereby: PLUMBING PERMIT TOWM OF SOUTH WINDSOR APPROVED DISAPPR, VED BUILDING INSPECTION DEPT. 'f 644-2511 Ext. 230 Date Building Inspector Application must be printed or typed. 1. LOCATION OF JOB- FEE SCHEDULE 2. OWNER: 3. ADDRESS: $ 0 - $19000 - $10.00 CZ- perOver $1 ,000 - $10.00$1 ,000 or 4. APPLICANT: �!//'��J/�'12e6ofZli fraction thereof 5. ADDRESS: �U g&iz�J- oVe300,1 6. EST. COST: $ C�8 7. IS THIS A CONTRACT COST? YES NO 8. FEE ENCLOSED: J&Z4&-. 9. TYPE OF >UrNG: IDENTIAL COMMERCIAL 10. TYPE OF JOB• ORIGINAL ALTERATION INSTALLATION ADDITION REPAIR BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) Off 11. LOCATION OF JOB: 7-ad Z ;w L,/ GENERAL PLUMBING 12. KIND OF INSTALLATION: 4t) Y/,, 6goA. SIZE OF MAIN DRAIN 14. NO. OF TOILETS_ STYLE /Q// 15. NO. OF URINALS - STYLE 16. NO. OF BATHTUBS_ 16A. NO. OF SHOWERS 17. NO. OF LAVATORIES 18. NO. OF SINKS _ 19. DISPOSAL 19A. DISWASHER 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS SIZE 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAIN9- 25. NO. OF OTHER FIXTURES KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS (!F) 30. R SEPTIC TANK? K or 3 31. SIZE OF WATER MAIN 31A. SIZES OF WATER PIPING & RISERS - 32. REMARKS AND FURTHER DETAILS / 5 /¢f„L WATER HEATER Ad 33. TYPE 34. MANUFACTURER TANKS SAFETY DEVICES TEMPERATURE 35. CAPACITY 39. RELIEF VALVE 36. TEST PRESSURE �h� LBS. 40. MANUFACTURER 37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE OZZ 106 38. TYPE 42. MANUFACTURER aqo�-:�� L CENSE NO. DA E SIGNATURE OF APPLICANT PHONE NO. FOR OFFICE USE ONLY, APPLICATION FOR HVAC PERMIT DATE: (NO. KQ 4 ) TOWN OF-,SOUTH WINDSOR EST.€OST: BLDG. PERMIT NO. 1540 SULLIVAN AVENUE FEE SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 $ 0 - $19000 - $10.00 � � � /s*__/1 $ 00 or fraction q +�*�f - $10.00 LOCATION OF BUILD G 07- t /�RA4 /7 fi OWNER / �ADDRESS TOWN PHONE NO. HVAC CONTRACTOR ADDRES TOWN PHONE N0. TYPE OF SYSTEM: HEATING TYPE OF BUILDING: RESIDENTIAL A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT ✓ ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS (BTUH) _(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT,(INCLUDING MAKE & MODEL NO.) : l3`/4&1 a Zor�is a fco/f6 �y e o e 44PIP'js GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN (BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.) : i` TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT) : TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) (PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and ��uch _wit all local ordinances and State of Conn. Buildin Codes in the erformanc ok."`� k� g P FURTHER DESCRIPTION OF WORK: f� '� /,� /I 74/ 0 !� e Nelz �l r7_1 ASTATE LICENSE - NAME & TYPE �� ATE IGNAT11RE OF APPLI TT T/44 , A VED DA E BD 4A 11/88 I = B = R CALCULATION SHEET 1503 (Modern Method) Copyright 1977 by The Hydronics Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL.A COL.B COL.C COL.D COL.E COL.F COL.G 1 ROOM cr O H L W H L W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS, FT. ~ —_ U BTUH per Fo t of 3 LENGTH EXPOSED WALLS, FT. Q Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA LL BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION (Table 9, Line 3 x H) ROOM LIN. FT.OF _ TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED (Bottom of table used for Line 5) xi 7 CEILING CONSTRUCTION C (Table 9, L x W) g FLOOR CONSTRUCTIONt O— (Table9, LxWorLin Ft) E 9 COLD PARTITION CONSTRUCTION F (Table 9, L x H) ---- - G 10 _ o a 1 Wall(With Opening,) C�. H C; 2 Walls(With Openings) D X " 3 Walls(With Openings) or Ent Hall J I 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE K COL A COL.B COL.H COL. I COL J COL. K COL.L TOTAL BTUH TOTAL ------ - -- -- --- ------ ---- --------------- ------ OF BUILDING RADIATION 1 ROOM — - ¢ _ AT SELECTED ' O H L W H L W H L W H L W H L W DESIGN TEMP.° 2 ROOM DIMENSIONS. FT DIFFERENCE ---- ---- ---- U -- - -- -- -- - -- 3 LENGTH EXPOSED WALLS. FT Q 4 WINDOW AND OUTSIDE DOOR AREA U. BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION *INCREASE BATHROOM (Table 9, Line 3 x H) TOTAL 20% 6 TYPE OF GLASS --- --- -------- ---- --- ------ ---- ----- -------- ------- -- (Bottom of table used for Line 5) 7 CEILING CONSTRUCTION ------- ---- -- — - ---------— --- — --" ---- - - - tFOR CONCRETE FLOOR ON (Table 9, L x W) GROUND OR FILL AT _ GRADE LEVEL,USE LINEAR B FLOOR CONSTRUCTIONt — FEET OF EXPOSED EDGE (Table 9, L x W or Lin Ft) 9 COLD PARTITION CONSTRUCTION (Table 9, L x H) 10 -c 1 Wall(With Openings) — C -- e 2 Walls(With Openings) D X _- 3 Wells(With Openings) or Ent Hall 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE This form is available from The Hydronics Institute,35 Russo Place,Berkeley Heights,N J 07922 FORM 1503 Page 1 *********************«********************************************************** HEATLOSS vers 3. 1 Copyright 1986, 1987, Thomas and Associates, Bellaire, Mi (616) 533-8472 ********************************************************************»*********** PETER SAVAS 56 CHRISTOPHER DR WESTFIELD, MA 01085 (413) 562 -6986 07-31-1990 D&G PLUMBING SOUTH WINDSOR, CT LOT 24 PARTHRIDGE MEADOW _............. ......... ENTRY Prepared by PETER S A V A S HEATLOSS THE TOTAL BTUH FOR THIS ROOM IS 3, 513 The total feet of radiation required for this room 6. 1 LIVING ROOM Prepared by PETER SAVAS HEATLOSS THE TOTAL BTUH FOR THIS ROOM IS 7, 744 The total feet of radiation required for this room 13. 4 .........._....................... ______________________________________________________________________ ----------------------------------------------- ---'---------------------------- DINING ROOM Prepared by PETER SAVAS HEATLOSS THE TOTAL BTUH FOR THIS ROOM IS 7, 351 The total feet of radiation required for this room 12. 7 ' ... .....-.......... ...-... ...............................----................... -------------------------------------------------------- ....._..... ............................ ........______________________ ______ ........ ............ ....... ________________________________ KITCHEN Prepared by PETER SAVAS HEATLOSS THE TOTAL BTUH FOR THIS ROOM IS 5, 720 The total feet of radiation required for this room 9. 9 FAMILY ROOM Prepared by PETER SAVAS HEATLOSS THE TOTAL BTUH FOR THIS ROOM IS 7, 811 The total feet of radiation required for this room 13. 5 LAV Prepared by PETER SAVAS HEATLOSES) THE TOTAL BTUH FOR THIS ROOM IS 1 , 300 The total feet of radiation required for this room 2. 2 WASHER/DRYER AREA Prepared by PETER SAVAS HEATLOSEC. THE TOTAL BTUH FOR THIS ROOM IS 1 , 485 The total feet of radiation required for this room 2. 6 _............................... ... ... ............_.......... ___________________________ _______ ________ _ __________________ RIGHT FRONT BEDROOM Prepared by PETER SAVAS HEATLOSS THE TOTAL 13TUH FOR THIS ROOM IS 4, 848 ' Page 2 The tota] feet of radiation required for this room 8. 4 ................................. ... ................._............._......... ..._.......... ..._..................________________________ ... ....... ..............................._....._..................... _.... _______ ......................�...................................... � ......... ............... ........ ���������������������� RIGHT REAR BEDROOM Prepared by PETER SAVAS HEATLOSS THE TOTAL BTUH FOR THIS ROOM IS 5,399 The total feet of radiation required for this room 9. 3 _........._________ _............ ............ ............ ______________________________.....____________..... .......... ............. ...__________..............._... ____ MASTER BATHROOM Prepared by PETER SAVAS HEATLOSS THE TOTAL BTUH FOR THIS ROOM IS 2, 040 The total feet of radiation required for this room 3. 5 _........ ............. ... ... ............. ........ ........ ........ __..........____________________________ ...... .....____________________________ _............._____________________________________ .........._.................... ........ ... _________________ ________ MASTER BEDROOM Prepared by PETER SAVAS HEATLOSS THE TOTAL BTUH FOR THIS ROOM IS 6, 790 The total feet of radiation required for this room 11 . 7 __... ....... ... ..............._____________________________________ BATH Prepared by PETER A.IS, HEATLOSS THE TOTAL BTUH FOR THIS ROOM IS 991 The total feet of radiation required for this room 1 . 7 TOTALS FOR LIVING AREA ............................ ......................_...._................................... ... ...... .......................____...................... _........ _____________.... _................................ ........_....... ............. ........ _____ HEATLOCS THE TOTAL BTUH HIS FOR T AREA IS 54, 991 The total feet of radiation required for this area 94. 8 End of report Page 1 ******************************************************************************** HEATLOSS v e r s 3. 1 Copyright 1986, 1987, Thomas and Associates, Bellaire, Mi (616) 533-8472 ******************************************************************************** PETER SAVAS 56 CHRI5TOPHER DR WESTFIELD, MA 01085 (413) 562-6986 07-31-1990 D&G PLUMBING SOUTH WINDSOR, CT LOT 24 PARTHRIDGE MEADOW ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDING /C) 1986, 1987 TA ENTRY Prepared by PETER SAVAS ROOM NUMBER 1 CEILING HEIGHT IS 10. 00 VOLUME IS 960. 00 CUBIC FEET 1 EXPOSED 0PE1\1IN8S, T0TALING >>>>>>>>>>>>>>>>>>>>>>>> 20. 40 SQUARE FEET 1 EXPOSED WALLS, not including openings, TOTALlNG >>> 99. 60 SQUARE FEET ROOM SIZE IS 12. 00 LONG by 8. 00 WIDE, TOTALING >> 96. 00 SQUARE FEET FLOOR TYPE IS: Floor over any Conditioned Space CEILING TYPE IS: Conditioned space above WINDOW TYPE IS: No openings in this room WALL CONSTRUCTION IS: Frame, Insulated HEATLOSS The Total B T U H for the outside walls are 657 The Tota BU H e l T for the. Exposed Openings are 574 The total BTUH for the ceilings 0 The total BTUH for the floors 0 The BTUH infiltration for the walls is 0 The BTUH infiltration for the openings s 2, 281 THE TOTAL BTUH FOR THIS ROOM IS 3, 513 The total feet of radiatzon required for this room 6. 1 ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA LIVING ROOM Prepared by PETER S A V A S) ROOM NUMBER 2 CEILING HEIGHT IS 10. 00 VOLUME IS 1650. 00 CUBIC FEET 1 EXPOSED OPENINGS, TOTALING >>> 56. 00 SQUARE FEET 2 EXPOSED WA L LS, not including openings, TOTALING >>> 204. 00 SQUARE FEET ROOM SIZE IS 11 . 00 LONG by 15. 00 WIDE, TOTALING >> 165. 00 SQUARE FEET FLOOR TYPE IS: Floor over any Conditioned Space CEILING TYPE IS: No Attic Space, part of Asphalt Shingled roof WINDOW TYPE IS: Double glazed with 1/4 in air space WALL CONSTRUCTION IS: Frame, Insulated HEATLOSS The Total BTUH for the outside walls are 1 , 346 The Total BTUH for the Exposed Openings are 3, 203 The total BTUH for the ceilings 581 The total BTUH for the floors 0 The BTUH znfi ] tratjon for the walls is 0 The BTUH infiltration for the openings is 2, 614 TH BTUH FOR THIS ROOM IS 7, 744 The total feet of radiatzon required for this room 13. 4 ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA Page 2 DINING ROOM Prepared by PETER SAVAS ROOM NUMBER 3 CEILING HEIGHT IS 8. 00 VOLUME IS 1144. 00 CUBIC FEET 3 EXPOSED OPENINGS, TOTAL_ING >>>>>>>>>>>>>>>>>>>>>>>> 78. 00 SQUARE FEET 3 EXPOSED WALLS, not including openzngs, TOTALING SQUARE FEET ROOM SIZE IS 13. 00 LON6 by 11 . 00 WIDE, TOTALING >> 143. 00 SQUARE FEET FLOOR TYPE IS: Floor over any Cond� tioned Space CEILING TYPE IS: Conditioned space above WINDOW TYPE IS: Double glazed with 1/4 in air space WALL CONSTRUCTION IS: Frame, Insulated HEAT LAC)SS The Total BTUH for the outside walls are 172 The Total BTUH for the Exposed Openzngs are 4, 462 The total BTUH for the cezlings 0 The total BTUH for the floors 0 The BTUH infiltration for the walls is 0 The BTUH infiltration for the openings is 2, 718 THE TOTAL BTUH FOR THIS ROOM IS 7, 351 The total feet of radiation required for this room 12. 7 ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDING /C) 1986, 1987 TA KlTCHEN Prepared by PETER SAVAS ROOM NUMBER 4 CEILING HEI8HT IS 8. 00 VOLUME IS 1768. 00 CUBIC FEET 2 EXPOSED OPENINGS, TOTALING >>>>>>>>>>>>>>>>>>>>>>>> 49. 80 SQUARE FEET 2 EXPOSED WALLS, not including openings, TOTALING >>> 190. 20 SQUARE FEET ROOM SIZE IS 13. 00 LON6 by 17. 00 WIDE, TOTALING >> 221 . 00 SQUARE FEET FLOOR TYPE IS: Floor river any Conditioned Spa� e CEILING TYPE IS: Condztioned space above WINDOW TYPE IS: Double glazed with 1/4 in air space WALL CONSTRUCTION IS: Frame, Insulated HEATLOSS The Total BTUH for the outside walls are 1 , 255 The Total BTUH for the Exposed Openings are 1 , 664 The total BTUH for the ceilings 0 The total BTUH for the floors 0 The BTUH infiltration for the walls zs 0 The BTUH infiltration for the openings is 2, 801 THE TOTAL BTUH FOR THIS ROOM IS 5, 720 The total feet of radiation required for this room 9. 9 ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA FAMILY ROOM Prepared by PETER SAVAS ROOM NUMBER 5 CEILING HEIGHT IS 8. 00 VOLUME IS 1920. 00 CUBIC FEET 1 EXPOSED OPENINGS, TOTALING >>>>>>>>>> �>>>�>�>>>>>>> 40. 00 SQUARE FEET 2 EXPOSED WALLS, not including openings, TOTALING >>> 216. 00 SQUARE FEET ROOM SIZE IS 12. 00 LONG by 20. 00 WIDE, TOTALING >> 240. 00 SQUARE FEET FLOOR TYPE IS: Floor over any Conditioned Space CEILING TYPE IS: Unconditioned Attzc Space Above WINDOW TYPE IS: Double glazed with 1/4 in air space WALL CONSTRUCTION IS: Frame, Insulated HEATLOSS The Total BTUH for the outszde walls are 1 , 426 The Total BTUH for the Exposed Openings are 2, 288 The total BTUH for the ceilings 1 , 056 The total BTUH for the floors 0 Page 3 The BTUH infiltration for the walls is 0 The BTUH infi ] tration for the openings is 3, 0� 1 THE TOTAL BTUH FOR THIS ROOM IS 7, 811 The total feet of radiation required for this room 13. 5 ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA _---------_______________________________________________________________ LAV Prepared i_-jy PETER SAVAS ROOM NUMBER 6 CEILING HEIGHT IS 8. 00 VOLUME IS 200. 00 CUBJC FEET 1 EXPOSED OPENINGS, TOTALING 9. �0 SQUARE FEET 2 EXPOSED WALLS, not including openings, TOTALING >>> 71 . 00 SQUARE FEET ROOM SIZE IS 5. 00 LONG by 5. 00 WIDE, TOTALING >> 25. 00 SQUARE FEET FLOOR TYPE lS: Floor over any Conditioned Space CEILINS TYPE IS: Conditioned space above WINDOW TYPE IS: Double glazed with 1/4 in air space WALL CONSTRUCTION IS: Frame, Insulated HEATLOSS The Total BTUH for the outside walls are 469 The Total BTUH for the Exposed Openings are 515 The total BTUH for the ceilings 0 The total BTUH for the floors 0 The BTUH infiltration for the walls is 0 The BTUH infi ] tration for the openings is 317 THE TOTAL BTUH FOR THIS ROOM IS 1 , 300 The total feet of radiation requz-red for this room 2. 2 ESTIMATED HEAT LOSS CAL L RES CUATION FOR lDENTIAL BUILDING (C) 1986, 1987 TA WASHER/DRYER AREA Prepared by PETER S A V A S' ROOM NUMBER 7 CEILING HEIGHT IS 8. 00 VOLUME IS 440. 00 CUBIC FEET 1 EXPOSED OP ENINGS, TOTALING >>>>>>>>>>�>>�>>>>��>>>>> 20. 40 SQUARE FEET 1 EXPOSED WALLS, not inc] uding openings, TOTALIN6 >>> 67. 60 SQUARE FEET ROOM SIZE IS 11 . 00 LONG by 5. 00 WIDE, TOTALING >> 55. 00 SQUARE FEET FLOOR TYPE IS: Floor over any Conditioned Space CEILING TYPE IS: Conditioned space above WINDOW TYPE IS: No openings in this room WALL CONSTRUCTION IS: Frame, Insulated HEATLOSS The Total BTUH for the outside walls are 446 The Total BTUH for the Exposed Openings are 574 The total BTUH for the ceilings 0 The total BTUH for the floors 0 The BTUH infiltration for the walls is 0 The BTUH infiltration for the openings zs 465 THE TOTAL BTUH FOR THIS ROOM IS 1 , 485 The total feet of radiation required for this room 2. 6 ESTlMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA RIGHT FRONT BEDROOM Prepared by PETER S A V A S ROOM NUMBER 8 CEILING HEIGHT IS 8. 00 VOLUME IS 1344. 00 CUBIC FEET 2 EXPOSED OPENIN6S, TOTALING >>>>>>>>>>>>>�>>�>>>>>>> 12. 00 SQUARE FEET 2 EXPOSED WALLS, not including openings, TOTALING >>> 196. 00 SQUARE FEET ROOM SIZE IS 14. 00 LONG by 12. 00 WIDE, TOTALING >> 168. 00 SQUARE FEET FLOOR TYPE 1S: Floor over any Conditioned Space Page 4 CEILING TYPE IS: Unconditioned Attic Space Above WINDOW TYPE IS: Double glazed with 1/4 in air space WALL CONSTRUCTION IS: Frame, Insulated HEATLOSS The Total BTUH for the outside walls are 1 , 294 The Total BTUH for the Exposed Openings are 686 The total BTUH for the ceilings 739 The total BTUH for the floors 0 The FIT UH infiltration for the walls is 0 The BTUH infiltration for the openings is 2, 129 THE TOTAL BTUH FOR THIS ROOM IS 4, 848 The total feet of radiation required for this room 8. 4 ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA _.......... RIGHT PEAR BEDROOM Prepared by PETER SAVAS ROOM NUMBER 9 CEILING HEIGHT IS 8. 00 VOLUME IS 1200. 00 CUBIC FEET 1 EXPOSED OPENINGS, TOTALING >>>>>>>>>>>>;- >>>>>> �>>>> 30. 00 SQUARE FEET 2 EXPOSED WALLS, not inc] uding openings, TOTALING >>> 170. 00 SQUARE FEET ROOM SIZE JS 15. 00 LONG by 10. 00 WIDE, TOTALING >> 150. 00 SQUARE FEET FLOOR TYPE IS: Floor over any Conditioned Space CEILING TYPE IS: Unconditioned Attjc Space Above WINDOW TYPE IS: Double glazed with 1/4 zn air space WALL CONSTRUCTION IS: Fr name?, Insul tat;ed HEATLOSS The Total B T U H for the outside wa] ls are 1 , 122 The Total BTUH for the Exposed Openings are 1 , 716 The total BTUH for the ceilings 660 The total BTUH for the floors 0 The BTUH infiltration for the walls is 0 The BTUH infiltration for the openings is 1 , 901 THE TOTAL BTUH FOR THIS ROOM IS 5, 399 The total feet of radiation required for this room 9. 3 _......... ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA MASTER BATHROOM Prepared by PETER SAVAS ROOM NUMBER 10 CEILING HEIGHT IS 8. 00 VOLUME IS 512. 00 CUBIC FEET 1 EXPOSED OPENINGS, TOTALING >>>>::.>>>>>>�>>>>>>>>>>>� 9. 00 SQUARE FEET 1 EXPOSED WALLS, not including openings, TOTALING >>> 55. 00 SQUARE FEET ROOM SlZE IS 8. 00 LONG by 8. 00 WIDE, TOTALING >> 64. 00 SQUARE FEET FLOOR TYPE IS: Floor over any Conditinned Space CEILJNG TYPE IS: Unconditzoned Attic Space Above WINDOW TYPE IS: Double glazed with 1/4 in air space WALL CONSTRUCTION IS: Frame, Insulated HEATLOSS The Total BTUH for the outside walls are 363 The Total B T U H for the Exposed Openings are 515 The total BTUH for the ceilings 282 The total BTUH for the floors 0 The BTUH infjltration for the walls is » The B T U H infiltration for the openings is 541 THE TOTAL BTUH FOR THIS ROOM JS 2, 040 The total feet of radiation required for this room 3. 5 - Page 5 ESTIMATED HEAT LOSS CALCULATJON FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA MASTER BEDROOM Prepared by PETER SAVAS ROOM NUMBER 11 CEILING HEIGHT IS 8. 00 VOLUME IS 1728. 00 CUBIC FEET 1 EXPOSED OPENINGS, TOTALING �x>>>>>� />>>) >>>>>>>�>�� 30. 00 SQUARE FEET 2 EXPOSED WALLS, not including openi ng s, TOTAL IN G >>> 210. 00 SQUARE FEET ROOM SIZE IS 12. 00 LONG by 18. 00 WIDE, TOTALlNG >> 216. 00 SQUARE FEET FLOOR TYPE IS: Floor over any Conditioned Space CEILING TYPE IS: Unconditioned Attic Space Above WINDOW TYPE IS: Double glazed with 1/4 in air space WALL CONSTRUCTION IS: Frame, Insulated HEATLOSS The Total BTUH for the outside walls are 1 , 386 The Total BTUH for the Exposed Openings are 1 , 716 The total BTUH for the ceilings 950 The total BTUH for the floors 0 The BTUH infiltration for the walls is 0 The BTUH infiltration for the openings is 2, 737 THE TOTAL BTUH FOR THIS ROOM IS 6, 790 The total feet of radiation required for this room 11 . 7 __....._.........._______________________________________________ ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDJNG (C) 1986, 1987 TA _........... _______________________________________________ BATH Prepared by PETER SAVAS ROOM NUMBER 12 CEILING HEJGHT IS 8. 00 VOLUME IS 32». 00 CUBIC FEET 1 EXPOSED OPENINGS, TOTALING >>>>>>>>>>>>>>>>>>>>>>>> 9. 00 SQUARE FEET 0 EXPOSED WALLS, not including opening�, T�TALING >>> 0. 00 SQUARE FEET ROOM SIZE IS 8. 00 LONG by 5. 00 WIDE, TOTALING >> 40. 00 SQUARE FEET FLOOR TYPE IS: Floor over any Conditioned Space CEILING TYPE IS: Unconditzoned Attic Space Above WINDOW TYPE IS: No openings in this room WALL CONSTRUCTION IS: Frame, Insulated HEATLOSS The Total BTUH for the outside walls are 0 The Total BTUH for the Exposed Openings are 689 The total BTUH for the ceilings 136 The total BTUH for the floors 0 The BTUH infiltration for the walls is 0 The BTUH infiltration for the openings is 0 THE TOTAL BTUH FOR THIS ROOM IS 991 The total feet of radiation required for thzs room 1 . 7 ............... ...... _____________________________________.......... ____________________________________ TOTALS FOR LIVING AREA VOLUME IS 13186 CUBIC FEET EXPOSED OPENINGS, TO TA LING >>>>>>) � >>>>>>>>>>>>>>>>>>> 364 SQUARE FEET EXPOSED WALLS, not including openings, TOTALING >>>>>> 1505 SQUARE FEET TOTAL SQUARE FOOTAGE OF HOME 1583 SQUARE FEET Prepared by PETER SAVAS HEATL as,S The Total BTUH for the Exposed Openings are 18, 602 The total BTUH for the ceilings 4, 404 The total BTUH for the floors 0 The BTUH infiltration for the walls is 0 The BTUH infiltration for the openings is 21 , 543 THE TOTAL BTUH FOR THIS AREA IS 54, 991 Page 6 The total feet of radiation required for thzs area 94. 8 End of report Electric# APPLICATION FOR BUILDING PERMIT Plumbing# 15 PARTRIDGE LANE j HVAC # 23414 Date: Sprinkler# NO' FINAL Estimated Cost $ v0 Building L COMPLETE RED BOXED AREAS Permit Fee $ Engines n TYPE OR PRINT ONLY Occupancy Fee $ Affidavit SIGN ON REVERSE SIDE Appr.for CO. F Total Fee $ � TO BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR,CT (Additional Cost) $ Th undersigned hereby applies to do work according to the following specifications: Job Location /S' o644 b6�r� Lot No. Side of Street Zone Applicant Tel. # it la Address Zip 660 7`{ Lic. # Owner ''' .e Address 45- 7- Architect Address Sq. Ft. New Area: 1st FI. 2nd FI. 3rd FI. Total New Area #Rooms # Lavatories #Bathrooms #Garo s Purpose of this permit: �L — OK ifl-,( City Water 21 Well 0 Septic System ❑ Sewer 2 Use Group Construction Type P Area / Basement, Garage Approved by Date 7 l f(�z Revised 6/95 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for w ' permit is asked,and agree that this building is to b ted the proper distance from all lines, side nes and required distances from all other zones and is located in zone i which this uild' nd its a is alto r— Signed -� I hereby apply for a Certificate of Occupancy for the work described in this application for the permit Signed -- DO NOT WRITE BELOW THIS LINE -- INSPECTION COMMENTS Bectric# t 'sli�9� CP�112-9191 APPLICATION FOR BUILDING PERMIT Plumbing# 15 PARTRIDGE LANE HVAC # 25262 Dat Sprinkl r# NO' 1 timat sf ` Building 5 2 �9 COMPLETE RED BOXED AREAS Permit Fee 3(o IROII Engineering TYPE OR PRINT ONLY Occupancy Fee $ Affidavit SIGN ON REVERSE SIDE Appr.for CO.p CT 5 2:I Total Fee { c)o TO BULDNG DEPARTMENT,TOWN OF SOUTH WNDSOR,CT (Additional Cost) 4 The undersigned hereby applies to do work according to the following specifications: Jo6 Location Lot No. Side of Street Zone Applicant 90 Se 9T L. CKUS kiq TeL# 6 4'It -b 116 Address I S f A R"t F*4C- Lr•l Zip 060? Lic.# Owner G 9!L Iq Address S A M E Architect Address Sq. Ft.N w Area: 1st FI. 2nd FI. 3rd FL Total New Area #Rooms #Lavatories #Bathrooms #Garages Purpose of this permit: AqgcNe. Z 6tce-, l �c Ci Water ❑ Well ❑ Septic System ❑ Sewer ❑ Ins. H.O. Cert. Area i Basement Garage Approved by Date Use Group y Construction Type Rowed 1197 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper dis ce from all street lines,side yard lines,and required distances from all other zones and is located in which lUs b ldin nd jP se is allowed. Signed I hereby apply for a Certificate of Occu cy or t work in this application for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- 98-25262-B 2,370 B10 FINAL 07/02/98 DCJ D NO ACCESS PROTECTION E10 FINAL 07/02/98 DCJ A B10 FINAL 05/27/99 DCJ A APPROVED FOR CO CLOSEOUT 98-14939-E 450 DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT (LO01 Application is hereby: TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Permit# APPRO 1540 SULLIVAN AVENUE 5 �' /' 644-2511 ext.230 Date Building Inspector Application must be printed or typed Location of job /.S fi/}Iq7-lqli)6W (,IV' Street No. Street Lot No. FEE SCHEDULE Floor Apt.No. $0 - $1,000 - $12.00 Over $1,000 $12.00 per$1,000 OWNER or any fraction thereof ADDRESS OWNERS PHONE# APPLICANT r� ADDRESS �S f < S. ����sd� �� 666 711 ESTIMATED COST$ O C ` ' IS THIS A CONTRACT COST? a YES NO ; �` �C► FEE ENCLOSED $ TYPE OF JOB: OR CO Original Installation Alteration/Addition/Repair Revised 11/95 APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A RESIDENTIAL BUILDING PERMIT APPLICATION YES / NO BUSINESS ASSEMBLY CURRENT USE AND OCCUPANCY MERCANTILE EDUCATIONAL FUTURE USE AND OCCUPANCY INSTITUTIONAL FACTORY STORAGE ENGINEER'S NAME PHONE GARAGE MIXED USE ADDRESS CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF MAIN FEEDERS AND RATING OF WIRE USED NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED 7 YES/NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPERATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK /1-)6 L ��d r/ ��� ,�<<o���f.�,D / ,moo n�tiyi�✓� THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. NAME STATE LICENSE NO. TYPE SI NA F APPLICANT PHONE NO. �f7 JO��� DATE pow" jC4 ci u _ (d 1540 SULLIVAN AVENUE•SOUTH WINDSOR,CT 06074-2786 solt:co�' AREA CODE 860/644-2511 FAX 860/644-3781 March 29, 1999 CERTIFIED MAIL Z 419-174-516 Mr. Robert Crusha 15 Partridge Lane South Windsor, CT. 06074 Dear Mr. Crusha: Pool season is almost here. I would like to remind you that the Building Permit(s) #25262 for your pool is (are) still open. State Building Codes require the issuance of a Certificate of Occupancy prior to its use. Please contact our office for a final inspection prior to the removal of the winter cover or adding any water to your pool. All permits must be closed by May 1, 1999. Should you have any problems meeting this date please send our office a letter stating the reasons. (The pool still can't be opened). If the pool is opened without the benefit of a Certificate of Occupancy a caveat may be placed in the land records stating there are Building Code Violations on your property. Please call John Collins, Chief Building Official, or myself should you have any questions regarding this. Our office hours are 8-9am. and 1-2pm. The phone number is 644-2511 ext. 232. Very trul s, glas C. Jourdan )Deputy Building Official c*, SENDER: J1 ■complete items i and/or 2 for additional services. I also wish to receive the p ■complete items 3,4a,and 4b. following services(for an ■Print your name and address on the reverse of this form so that we can return this extra fee): card to you. 8 o ■Attest this form to the front of the mailpiecs,or on the back if space does not 1. ❑ Addressee's Address ■permit. Receipt Requested'on the mailpiece below the article number. 2. ❑ Restricted Delivery ■The Return Receipt will show to whom the article was delivered and the date C delivered. Consult postmaster for fee. 3.Article Addressed to: 4a.Article Number Mr. Robert Crusha a 4b.Service Type .1 1 15 Partridge Lane yp I S o. Wi ndsor,, C T 0 6 0 7 4 ❑ Registered � certified 01 ❑ Express Mail ❑ Insured 51 IN Rehim Remipt ise- COD 7.Date of Delivery 5.Received By:(Print Name) 8.Addressee's Address nl if requested and fee is paid) r C 6.Signature:(A r or Ag I � X '� Ps Form 38 1, December 1994 Domestic Retum Receipt UNITED STATES POSTAL SERVICE First-Class MailPostage&Fees Paid USPS Permit No.G-10 • Print your name, address, and ZIP Code in this box • TOWN OF SOUTH WINDSOR BUILIDING DEPARTMENT 1540 SULLIVAN AVENUE SOUTH WINDSOR, CT 06074-2786 i ~ T-a 0-f e � 4 1540 SULLIVAN AVENUE•SOUTH WINDSOR,CT 06074-2786 R.co��� AREA CODE 860/644-2511 FAX 860/644-3781 May 3, 1999 Mr. Robert Crusha 15 Partridge Lane South Windsor, CT 06074 Dear Mr. Crusha: This letter is a follow up to our last correspondence,which was either a phone call or a site visit. The first dead line has passed and the permit#25262 remains open. Remember that your pool may not be opened until a final inspection has been done and a Certificate of Use and Occupancy issued. Please respond as soon as possible so that we can bring closure to this matter. Since you have responded to the first letter we have extended your deadline to May 31, 1999. If at that time your permit has not been closed, we will file a caveat in the land records stating that, there are Building Code Violations on your property. Should you have any questions regarding this matter,please call John Collins, Chief Building Official, or myself. Our office hours are 8-9am and 1-2pm. The phone number is 644-2511 ext. 232. Very truly s, c ouglas C. Jourdan Deputy Building Official Electric# APPLICATION FOR BUILDING PERMIT GE 'Plumbing# 15 PARTRID LANE HVAC # Date: w Z�' 4 No. 26269 Sprinkl r# FINAL APPROVALS Estimated Cost $ °= Building os I at C,; COMPLETE RED BOXED AREAS Permit Fee $ 2 Engineering TYPE OR PRINT ONLY Occupancy Fee $ Affidavit SIGN ON REVERSE SIDE Appr.for CO. j 1 Total Fee TO BUILDING DEPARTMENT,TOWN OF SOUTH WNDSOR,CT Additional Cost) The undersigned hereby applies to do work according to the following specifications: Job Location S ✓r-y�1r C Lot No. Side of Street Zone Applicant v 2 Tel#K 4 6F -01-7 6/ Address a r► e Zip Ot ' Lic.# Own r PC) rF 1.a Address 9-S 2 6e- Architect Address Sq. Ft.N w Area: 1st Fl. 2nd Fl. 3rd Fl. Total New Area #Rooms #Lavatories #Bathrooms #Garages Purpos of this permit: 00'( 12 ,City Water ❑ Well ❑ Septic System ❑ Sewer ❑ Ins. H.O. 100" P. Cert. Area Basement Garage Approved by Date do IM Use Group Construction Type Rev6ed 1/97 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in whiTbuilding and sus allowed Signed'< I hereby apply for a Certificate of Occupanc for the wo de in this application for the permit. Signed► DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- 99-26269-B 1,600 B10 FINAL O8/05/99 DCJ A APPROVED FOR CO & CLOSEOUT i • af�i 1 Y _ • Pr 1 ,w• i, h+ •Z �' r a Al 'FA ,�' eY, a '.e ° - SI'fit n'�" '•b ..'" /� 1 AM �'� '•��, ;�•t,,r�R. :,s�" • � 'i r' �<• ` .��-+ ;'4 T' r "if h. �' ILry.:�t'e,' ' ` 4'�•, Al. ff � �.ro�• .�� a � '., ,-"�`' •�'��'Erl h' ���j,;'�i�`.��'`'� � t`'A �� ���.,� �',• i 1 �- ��� r- lk I o_ 07 4 $ a '. � �� ' -•_ � .,,�Za ItF�, . y i� • C\J �, Ilk*s C� ti CIO ' •• �� •p. © 1— � ,+ �`:• "• .a � ,-�•+''���r� ob ma to 's� s `. �•+ C' �. t�`!�•+!w�9 r rT �w r IIA r`I`, •'L' ,', ~ls �� c' �r,` •"�J'.. ',rt{• t�;,'^r ti `ii�'+:/r///..,yv�; _fr.v.r a.y.,,'• ` L 5'• .it _. •� to'-t R ' Y^ ' 5~L 1 �•.s r L f er.S- `L��,`, �,� !'^'r�")mar.'�l.�„Yr �"�jj Sei.��i,2y �. ryf,.•. .,./r .' � � �! 3<J ( • . .+•-_...,, " � .. •r7 „+ � ..`,'; � e'it�,� '�1'Y�� ,'�„�',H' e'y�'r�`fy Y(. i ' �'•' '�, ;�1^�� `".• ` , a, 'i _` - ��I'-! ct�' {•,� �.A ,�"''/'�1 s-_"'� � "` k �a..-.- �•a%�wt .�r- �'� .�t [,�• �.�?r'� ,} .Zr,� "�r�r At r`� .0 . ''� . �7 'y�� v�'*` . � tB iNE BUILDING DEPT. TOWN OF SOUTH WINDSOR This certified that this plan and specifftations are true copies of the proposed building or alterations to b• erected at 3 c4 Stree, together with amendme s tE-ted in application are filed with plan and 1 agr to comply with all zonlnP -3uildmg and state laws and such orders �s sh1h L issued by the Building Department during pendi•n, •f this application and final Issuance of a buildinr permit. Signed _ this plan i approved subject to the condition that orders and ordinances regulating building shall be complied with Conditionally Approved These filed with Building Inspector Clerk IDAt. "g: z b b CERTIFICATION OF ZONING COMPLIANCE Proposed buiiding(s), use(s) and/or structlAre(s', s.i.)wn on this plan 3ppcar(s) be in .ifo,,c-n-3nce with current J , :-1h Vino lulations. Varsc races and �aLe � a E t �,rrs-rat Officer —t"e.g