Loading...
HomeMy WebLinkAbout139 Rockledge Drive P/,,i P ti ,tI3 0 THE BUILDING INSPECTOR of the APPLICATION FOR TOWN PLAN EXAMINATION AND OF SOIT WS'O�i, BUILDING PERMIT IMPORTANT — Applicant to complete all items im sections: 1, 11, 111, IV, and IX. O z ZONING �• AT (LOCATION) z DISTRICT� �� LOCATION (NO.) (STREET) n OF BETWEEN 42& l /QA-W AND !///��j�t BUILDING (CROSS STREET) (CROSS STREET) SUBDIVISION LOT L 0 T BLOCK SIZE N II. TYPE AND COST OF BUILDING — All applicants complete Parts A — D —� A. TYPE IMPROVEMENT D. PROPOSED USE — For"Wrecking" most recent use T 1 New building Residential Nonresidential 2 ❑ Addition(It residential, enter number 12�e family 18 ❑ Amusement, recreational of new housing units added, if any, in Part D, 13) 13 ❑ Two or more family — Enter 19 ❑ Church, other religious number of units— — — — --jo. 20❑ Industrial 3 ❑ Alteration (See 2 above) 14 Transient hotel, mote , ❑ T i h l l 21 ❑ Parking garage 4❑ Repair, replacement or dormitory — Enter number 5 ❑ Wrecking (1/multifamily residential, of units ——————— — -i 22❑ Service station, repair garage enter number of units in building in 15 E Garage 23❑ Hospital, institutional Part D, 13) 16 ❑ Carport 24❑ Office, bank, professional 6 ❑ Moving (relocation) 25 Public utility 7 ❑ Foundation only 17❑ Other — Specify ❑ Y 26 ❑ School, library, other educational B. OWNERSHIP 27❑ Stores, merconfile 8 ❑ Private (individual, corporation, 28❑ Tanks, towers nonprofit institution, etc.) 29❑ Other — Specify 9 ❑ Public (Federal, State, or local government) C. COST (Omit cents) Nonresidential — Describe in detail proposed use of buildings, e.g., food processing plant, machine shop, laundry building at hospital, elementary 10. Cost of improvement•,,••,•,••,,.,,, S school, secondary school, college, parochial school, parking garage for, department store, rental office building, office building at industrial plant. To be installed but not included If use of existing building is being changed, enter proposed use. in the above cost a. Electrical...................... b. Plumbing ...................... c.Heating, air ..........I z d. Other(elevator, etc.)............ 11. TOTAL COST OF IMPROVEMENT $ 4 r/ III. SELECTED CHARACTERISTICS OF BUILDING — For new buildings and additions, complete Parts E — L; for wrecking, complete only Part J, for all others skip to IV. E. PRINCIPAL TYPE OF FRAME G. TYPE 0 SEWAGE DISPOSAL J. DIMENSIONS 30❑ s my(wall bearing) 40 Public or private company 48• Number of stories................ 31 49. Total square feet of floor area, Wood frame 41 ❑ Private (septic tank, etc.) all floors, based on exterior 32❑ q Structural steel dimensions ..................... of ys-?� 33❑ Reinforced concrete H. TYPE OAF WATER SUPPLY 42 Public or private company `-0. Total land area, sq.ft. ........... 34❑ Other — Specify P P Y ver ow 43❑ Private(well, cistern) K. NUMBER OF OFF-STREET PARKING SPACES F. PRINCIPAL TYPE OF HEATING FUEL I. TYPE OF MECHANICAL 51. Enclosed ....................... 35 Gas Will there be central air 52. Outdoors....................... conditioning? L. RESIDENTIAL BUILDINGS ONLY 37❑ Electricify 44❑ Yes 45 Q N 53. Number of b dr ms.............. 7 38 ❑ Coal 39❑ Oth r— Specify Will there be an elevator? 54. Number f Full.......... 46❑ Yes 47 o bathr ms ........F/ i IV. IDENTIFICATION — To be completed by all applicants Name jM s , 4r AWYty, and State ZIP code Tel. No. 185 SILAS DEANE HIGHWAY Owner or " Lessee FIELD. ONN. 1�S l KUI,I lI).v l,U;y •'HIV 2 185 SILAS DEANE HIGHWAY Contractor ° 3. Architect or Engineer The owner of this building and the undersigned agree to conform to all applicable laws of this jurisdiction. Signature of applicant Address Application date LA br c. lc U k-;1101v LU. 00 NOT WRITE BELOW THIS LINE V. PLAN REVIEW RECORD — For office use Plans Review Required Check Plan Review Date Plans By Date Plans By Notes 9 Fee StartedApproved BUILDING $ PLUMBING $ MECHANICAL $ ELECTRICAL $ OTHER VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS Permit or Approval I Check Date Number B Permit or Approval I Check Date Number By pp Obtained y pp Obtained BOILER PLUMBING CURB OR SIDEWALK CUT ROOFING ELEVATOR SEWER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OIL BURNER WRECKING OTHER OTHER VII. VALIDATION Building Permit number Building if Permit issued /A"t /z, 19 Building Permit Fee Ap �o(ve b v TITLE "X 4 TOWN OF SOUTH WINDSOR BUILDING PERMIT 6 F! i , E Date Aug. 2 2 , 198 4 Fee Paid $. . .5 2.8 .0 0 Est. Value $8.8.,.Q 0 0 a Permit N V _ 14029 !4 i 3 on the side of x Lot 05 Rockledge Dr i ve Street i Street No. 1 -3 9 Owner LaCa va Construction ro Applicant r--- A- Lac'a- va CERTIFICATE OF OCCUPANCY ISSUED: Date No. Go:n Fee Paid $ 3 .00 CLASSIFICATION Dwelling BUILDING PERMIT N'° 14029 OFFICE OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. South Windsor, Conn. M CI. 2 2 1984 M#iz is to Terfifgp That LaCava Construction Co. is hereby granted permission to at estimated value of $ • on the side of Lot #5 Reekledge Drive Street on land owned by LaCava Construction Co_ Said Work to be as described in Application No. 14329 and to conform to specifications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH WINDSOR. Issued Aim 1984 uilding n,sptctor. Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: `When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costs and damages which it shall sustain, or be compelled to reason therefor." NIF L.T,D. Wooer FNt� Svl�p�V t�1DtJ o2-o4 Wl ,�-4 5-5":d 76..11 ' Co Z.78' So.mat LaNE W 7 1 f ICY Z Q � i i Lc:..-r 't,,6� O L o T' J*s LaT r 'fit.�ih ¢r. 3• ' �wiMrk lrtta�-is� his. 1".. ,. _ S �Ea..L►3.S0 �� � _ r S Zz, 3V a a A400 IWPAK. Cv"0RWbt'. '_ Z f t NoT 1 P s To Be Sri'T, oN loftCOM ALA Fkc. AT Y z� .,.,...._.,., g t07 to L. �v►LKu�C qE pIGZ �V E = 144l.�S 'V�-OoOWA-Moti! A17 t3+7,:,T 1'� --1 i;L4 E� ti = Zoi.00 � IL L O T P L A N PRO PERT, O F �,�` p/f'.r `t�'``,�`e vL1► CC*A'.5' kOr.'f I 040-A CCU. B•IOkA1 �F�p �P CT-, r NFREercERr1Fr rNAr rN/S mAP /S JVRSTANr/ALLY CORRECT AND ZONINi RECULAr/ONS AR.E NOr VIOLATED. SCA L E•• I IN =4oFT. DA T E• V3-4--84. 00 TC �.,T DATE:. __ . Dwelling - Lot #5 Sa v.Wd. 1 8/22/84 LaCava• Construction Co. 139 Rockledge Drive permit # 14029 Electrician D.. Garber # 8578 Heating Contr. D. Bartone P & H # 6033 Plumbing it D. Bartone P & H # 6559 Oil Burner # Certificate of Occupancy # 6870 Sewer Permit Plot plan apprd. per Engr. P rmit No.' D TOWN OF SOUTH WINDSOR SOUTH WINDSOR, CONN. N 6fl ® . Permit ... . Certificate of Occupancy THIS �'Q CE F a the6 /J Eat No �F in the wn of South Windsor, Connecticut, has been erected and complete in accordance with the Building Code and Zoning Regulations of the Town of South Windsor, and is hereby approved for occupancy.�� .� 5feTauilding Inspector �wner, Builder Fee Paid Date l (�_r �� 19 8578 ELECTRICAL APPLICATION Application No. Q,gig on the side of Lot #5 RA8k-le-d-ge Dr. Street Street No. 119 Owner Larava Const- Co- Electrician David r-a b r FILED IN OFFICE OF The Building Inspector 11/13 / 19-SA INSPECTION. 13r No Electrical Work shall be started until a Per- mit is granted by the Building Inspector. In New Buildings no wiring shall be started until the plumbing and heating pipes, and the fire stops (if of wood) are installed, without a special permit from the office of the Building Inspector. Electrical Permit No. ........................................ Master License No. ..19 /..................... TOWN OF SOUTH WINDSOR Building Permit No.l.�4� . .. ............. BUILDING DEPARTMENT Date Filed ......................... ... Date Final Approval . . .......... .. ...... ............ APPLICATION FOR ELECTRICAL WORK Electrical Inspector 13 t9 /�I,,lee'"s 1 -t �4)7 Sr OB OWNER: A-A, .6-ST........... ..................................... JOB LOCATION. .. ... .......................... ........ ........................ Sideof Between . .... ................. and ................................................................................. Name of Building Owner -q A-'Ce- Address ........W� 62/7... If work is for Lessee—Give name .... Address ................ ............... .......... ............. ... ... ... ........... Building now occupied as (unless new) No. of family units now .. .. ........... 12 -r -e Building to be occupied as ....... psi 0- C .. .. ....... .. ....... ........ Number of family units to be ........ .. ........ Is this work included in Building Permit? Y ........... ........... Permit Fee .. .. ..... .......... ........... ....................................................... (If no Building Permit) Permittee Business Address Garber-Doran,Inc. Telephone ... COST OF INSTALLATION: J,e C-1. ..)e-;r..... ....................... ... ........... 80 Carpenter Rd. 11 Manchester,CT 06040 ................................................................ TO BE FILLED OUT BY PERMITTEE TO BE WIRED EXISTING APPLIANCES Number of light outlets to be installed Number of convenience outlets to be installed y j- Number of present Appliance Circuits ..... ..... .................. ... ..... Number of switches to be installed Do these include Range ❑ Water Heater ❑ Number of appliances to be installed (as listed below) Dryer ❑ Air Conditioner E] Oil Burner E] TYPE RATING NO. . . . . . . . . Dish Washer ❑ Gas Burner ❑ Range Well Pump E] Elec. Heaters ❑ Range Top . . . . . . Oven . . . . . . . . REMARKS: Water Heater /-5- Lk�- Aq11 /-I Clothes Washer . . . . Clothes Dryer . . . . . . 145— /0 Dish Washer . . . . . . . Air Conditioning Motor Oil Burner Motor Gas Burner . . . . . . Circulator Motor . . . . Attic or Large Fan . . . Well Pump . . . . . . Electric Heat . . . . . -�i5 . & S— Other .1 Number of new Lighting Circuits . . . . ........................ Number of new Appliance Circuits . . . ............................. Number of Heating Circuits .............. Number of Motor Circuits Size of present service ............... .... Size of service to be . .... .......... ..... ................................ 6557 PLUMBING APPLICATION Apphadim Nos 7333 on the aide of .....�....... Sftoct Street No. _ � x a 5� Oaner(X/.6 Plumber Fled in Offia of The Bu�og Tarpecoor Oct_ 29 191UL n�e�ac�riox. f No parson"cosrtcI f; add to or alder my portion of the &gimp system of auy ba'l&g (enzpt to repair le 6) use a Ple®it is ommed by the Bud&mg Imposm APPLICATION FOR PLUMBING PERMIT (Continu d fr m Revers Sid TOWN OF SOUTH WINDSOR, CONN. 11. LOCATION OF JOB 3 } NO. STREET FLOOR APTAO. GENERAL PLUMBING 12. KIND OF INSTALLATION / J��[.L� 442ga 13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS STYLE 15. NO. OF URINALS STYLE 16. NO.OF BATHTUBS�_17.NO.OF LAVATORIES 18. NO.OF SINKS 19. NO. OF WASHTUBS 20. NO.OF CONDUCTORS SIZE 21. NO. OF STACKS SIZE 3/ 22. AREA OF ROOF 23.NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 3 -A -L 28. IF NO WINDOW,WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. ARE SEWAGE AND WATER FACILITIES AVAILABLE? SIGNATURE ADDRESS LICENSE NO. �^C�-5 3 ESTIMATED COST C>9 C'o / TELEPHONE OWNER.-,A r A ADDRESS)cP�r- �L-e OK10 9 WATER HEATER 31. TYPE / v 32. MANUFACTURERS 5 � �} TANK SAFETY DEVICES 33. CAPACITY 37. TEMPERATURE RELIEF VALVE V 34. TEST PRESSURE 38. MANUFACTURER (,U`7" �7 35. WORKING PRESSURE 39. PRESSURE RELIEF VALVE 36. TYPE 40. MANUFACTURER ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE OWNER OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. CD962 DATE SIGNATURE OF APPLICANT PERMIT # Application For 6421 6033 DEPARTMENT DECISION W Heating Permit 0 3 APPLICATION IS HEREBY:o DEPARTMENT OF LICENSES AND INSPECTIONS a� N +. Ot APPROVED ❑ DISAPPROVED .� TOWN OF SOUTH WINDSOR 0 10/26 f R4 Thomas p D' A r DATE CHIEF INSPftTO-111 APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOW • O w O w 1. LOCATION OF JOB 132�+ O NO. wrRwwT r v 0 LOT NO. FLOOR APT. NO. O O 79 0 rz 2. OWNER i,�v1.f IeA e 7 o O !. ADDRESS4- bo 3 Cc -- ,( —� � 4.PHONE I Cn � S. APPLICANT � d� ad ,Go Id. ADDRESS Mr �3_7.PHONE 2 I B. LICENSE NO. O 4 Cj a ' p w B. EXPIRATION DATE OF LICENSE— I() 1=k v O 10. ESTIMATED COST s ~ 11. IS THIS A CONTRACT COST? E.IS ❑ NO bo .1) .r. .� 12. FEE ENCLOSED S- Permit 14029 � v k IS. TYPE OF BUILDING: rA � d W A LL* SIDENTIAL ❑ COMMERCIAL 3 14. TYPE OF JOB: ❑ INDUSTRIAL aN. � ATI N L ❑ ALTERATION STALLA ADDITION REPAIR APPLICATION FOR HEATING PERMIT (C ntinued it m Revers side) 11. LOCATION OF JOB ' FLOOR AFT.NO. 12. TYPE OF INSTALLATION; ❑ OIL BURNER ❑ ELECTRIC ❑ VENTILATION ❑ SPRINKLER ISGAS BURNER ❑ STACK ❑ INCINERATOR ❑ MISCELLANEOUS IDENTIFY SIZE LOCATION SIZE SIZE 13. OF TANK OF TANK OF FILL OF VENT 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NO. B.T.U. OR SQ. FT. NET "'IF vB.T.U. OR SQ. FT. GROSS FIRING RATE FLOORS TO BE HEATED NEW OR OLD BUILDING Al 'd� INSULATED - YES OR NO TYPE OF WALL— f "` INSULATION ROOF OR CEILING INSULATION O AVG. SYSTEM WATER TEMP. x d .T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE c:" Aid °FAHRENHEIT MAKE OF RADIATION: BASEBOARD. COPPER CONVECTORS, OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SO. FT. OR B.T.U. _ U" 07 DESCRIPTION OF WORK rA)C.,1 15. TO BE DONE; 16. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS): ROOM SIZE WINDOWS AREA — SQUARE FEET B.T.U. B.T.U. 0 DISTRIBUTION INSTALLED AND OOORS VOLUME TOTAL TOTAL 0 ROOM NO' GROSS GLASS NET WALL CEILING FLOOR CU.FT. AT 70•R CORRECTED <j IL RAD. LL REGISTER L W N AND E TEMP. TO F TYPE AND SIZE OR LEADER SIZE < WALL F'LtG (INFILT.I DIFF. •F O dib SO' FT' FREE AREA l><1 TOTALS A. HEAT LOSS FROM BUILDING B.T.U./HR. B. DOMESTIC HOT WATER DEMAND B.T.U./HR. C. PIPING, OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY; NAM[ ADDRESS SUBCONTRACTORS AND IS. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. APPLICATION TO BE COMPLETELY FILLED IN. v 22 DATIll 816NATUR[ OF APPLICANT A �r Copyright 1960,by the Institute of Boiler and Radiator Manufacturers. t ESTIMATE QUANTITY ITEM AMOUNT Boiler No. Net I=B=R Rating* Oil or Gas Burner or Stoker, with Controls Oil Tank, Pipe and Fittings Combustion Chamber or Stoker Hearth Pump Thermostat Low Limit Control Reverse Control Extra Controls Draft Regulator Flow Control Valve Pressure Reducing Valve Relief Valve Air Cushion Tank Domestic Water Heater and Tank Mixing Valve Pipe, Valves, Fittings, Hangers Pipe Covering Heating Units (Radiators, Baseboards, Convectors) Radiator Enclosures Sets — Radiator Brackets Radiator Valves Radiator Union Elbows Radiator Air Valves Main Air Vents Floor and Ceiling Plates Smoke Pipe Foundation Electric Wiring Pounds — Asbestos Cement Paint Freight and Cartage Labor Incidentals Total Cost Overhead Pr fit Bid *Net I=B=R Rating f Boiler sh uld equal r exceed the total hoof loss of the h use plus, pr per,allowance for domestic hot water BURNHAM CORPORATION �','QpoN Heating & Cooling Division - Irvington, N.Y. '-�av, --+,. 1_�_ S:xa.. 1=B=R CALCULATION SHEET 1503 Copyright 1965 6y the Institute of Boiler and Radiator Manufacturers, 393 Seventh Ave., New York, N.Y. 10001 OWNER ADDRESS .� DESIGN TEMPERATURE DIFFERENCE -7'O F. DATE COL. A COL. B COL. C COL. D COL. E COL. F COL. G ROOM 1 ROOM TOTALS RADIATION O W W H L W H L W H L W H L W H L W FROM LINE 12 SELECTED 2 ROOM DIMENSIONS, FT. ~ O m $ ` ' 1� aCA C H` 3 LENGTH EXPOSED WALLS, FT. Z 4 WINDOW AND OUTSIDE DOOR AREA 1 �� STUN BTUH BTUH BTUH BTUH D S WALL CONSTRUCTION C-7 q 3� n ?� E �a 00 6 TYPE OFGLASS 7 CEILING CONSTRUCTION V wl F �0� 8 FLOOR CONSTRUCTION t G 9 COLD PARTITION CONSTRUCTION H 10 J O ON E WALL(WITH GLASS OR EXTERIOR DOOR) CL TWO WALLS 2 THREEWALLS OR ENTRANCE HALL " 02 �_ �•��.� ���. ,^ J 11 TOTAL BTUH AT70FTEMP.DIFFERENCE• L-�L�V 12 TOTAL BTUH AT DESIGN TEMP,DIFFERENCE K COL. A COL. B COL. H COL. 1 COL. J COL. K COL. L L 1 ROOM Ir / o ww H L W H L W H L I W H L W H L W 2 ROOM DIMENSIONS, FT. V Q TOTAL BUILDING R TOT AL ON 3 LENGTH EXPOSED WALLS, FT. Q d LL Z AT SELECTED 4 WINDOW AND OUTSIDE DOOR AREA DESIGN TEMP. DIFFERENCE BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION 6 TYPE OF GLASS 7 CEILING CONSTRUCTION INCREASE BATHROOM TOTAL 20% 8 FLOOR CONSTRUCTION t 9 COLD PARTITION CONSTRUCTION 1 FOR CONCRETE FLOOR ON GROUND OR FILL AT GRADE LEVEL, USE LINEAR FEET lO J 0 ONEWALL(WITH GLASS OR EXTERIOR DOOR) OF EXPOSED EDGE I� TWO WA L LS Z¢ THREE WALLS OR ENTRANCE HALL • 11 TOTAL BTUH AT70FTEMP.DIFFERENCE* 12 TOTAL BTUH AT DESIGN TEMP.DIFFERENCE FORM 1503 Copyright 1960,by the Institute of Boiler and Radiator Manufacturers. ESTIMATE QUANTITY ITEM AMOUNT Boiler No. Net I=B=R Rating* Oil or Gas Burner or Stoker, with Controls Oil Tank, Pipe and Fittings Combustion Chamber or Stoker Hearth Pump Thermostat Low Limit Control Reverse Control Extra Controls Draft Regulator Flow Control Valve Pressure Reducing Valve Relief Valve Air Cushion Tank Domestic Water Heater and Tank Mixing Valve Pipe, Valves, Fittings, Hangers Pipe Covering Heating Units (Radiators, Baseboards, Convectors) Radiator Enclosures Sets — Radiator Brackets Radiator Valves Radiator Union Elbows Radiator Air Valves Main Air Vents Floor and Ceiling Plates Smoke Pipe Foundation Electric Wiring `Pounds — Asbestos Cement Paint Freight and Cartage Labor Incidentals Total Cost Overhead Pr fit Bid *Net I=B=R Rating of B iler should qual r exceed the t tal heat loss of the h use plus,proper Allowance for domestic hot water E BUR NH H AM C O 4nc"O��e R P O R A T I O N ,_,T\'G��Qr •s �'vc. �� / 'o09 Heating & Cooling Division - Irvington, N.Y. =B=R CALCULATION SHEET 1503 Copyright 1965 by the Institute of B iler and Radiator Manufacturers, 393 Seventh Ave., New York, N.Y. 10001 WHER ADDRESS DESIGN TEMPERATURE DIFFERENCE -70 F. DATE COL. A COL. B COL. C COL. D COL. E COL. F COL. G ROOM 1 ROOM ►..Li k t C���Ci' � C�c ��J w- TOTALS RADIATION O W W H H L W H L W H L W H L W FROM LINE 12 SELECTED 2 ROOM DIMENSIONS, FT. ~ m �ji d F, I1� Cot 3 LENGTH EXPOSED WALLS. FT. < a Z 10 C 4 WINDOW AND OUTSIDE DOOR AREA W — �' 3 s- BTUH BTUH BTUH BTUH BTUH D 5 WALL CONSTRUCTION 6 TYPE OF GLASS 7 CEILING CONSTRUCTION F 8 FLOOR CONSTRUCTION 1 0S JQ �� f �1� (R G oo 9 COLD PARTITION CONSTRUCTION l \! lJ H `�Lr o uc U 10 . 0 ONEWALL(WITH GLASS OR EXTERIOR DOOR) ( eo Z) ( I 1' 000 3 Zt TW O WA L LS " ,S __� ��� "��� -� THREEWALLS OR ENTRANCE HALL 2 -��� �� 5 J� 1 Q) , 31ioo 3 11 TOTALBTUHAT7OFTEMP.DIFFERENCE• �(�� t JQ� SJVV �� ��� I"�l� V 12 TOTAL BTUH AT DESIGN TEMP.DIFFERENCE K < j COL. A COL. B COL. H COL. I COL. J COL. L L 1 ROOM � ,h.✓\ ;� � O W W H W H L W H L W H L W H L W 2 ROOM DIMENSIONS, FT. V Q � �3 5 �� OF BUILDING RA TOTAL BTUH DIATION ON 3 LENGTH EXPOSED WALLS, FT. Q (LZ 3 O 2 4 WINDOW AND OUTSIDE DOOR AREA U. �� AT SELECTED DESIGN TEMP. DIFFERENCE BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION O� 730 �0 ` Q \ A E5 0^ �Q 6 TYPE OF GLASS 7 CEILING CONSTRUCTION ® INCREASE BATHROOM C�J0 ��� �� TOTAL 20% 8 FLOOR CONSTRUCTION 1 9 COLD PARTITION CONSTRUCTION 1 FOR CONCRETE FLOOR ON GROUNDOR FILL AT GRADE LEVEL, USE LINEAR FEET 10 J Z0 ONE WALL IWITH GLASS OR EXTERIOR DOOR) ��Z ����y, �� OF EXPOSED EDGE 1i t TWO WA L LS • k �s ���"� ��� - 3V� Z � THREE WALLS OR ENTRANCE HALL 4.0O --�� -�� 11 TOTAL BTU HAT70FTEMP.DIFFERENCE Li On IC1,VVz) 0-600 90Q 12 TOTAL BTUH AT DESIGN TEMP.DIFFERENCE FORM 1503