Loading...
HomeMy WebLinkAbout135 Rimfield Drive MAL INSPECTI S: Building i s� APPLICATION FOR BUILDING PERMIT Plumbin S� HVAC f Date.-" F4 0Ir 1 b , 1 9 9 3 Sprinkler 135 RIMFIELD DRIVE Electric / Estimated Cost $ 759000 . 00 Zoning Permit Fee $ '7 5 0 . 00 Affidavit g NO. 20942 Occupancy Fee $ 3 . 00 Eng. Dept. COMPLETE RED BOXED AREAS. Fire D pt. TYPE OR PRINT ONLY Total Fee $ 753. )0 Health Dept. SIGN ON REVERSE SIDE. Approved for CO: (Additional Cost) $ a 9 a 3 TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Job Locatio 35 1 �q I E LD n-. I V E Lot No. ° If Side of Street IL Zone RR Applicant,)ART JILL REALTY INC Tel. # 544-8137 Address ,558 ELJINGTON RD SO. WINDSOR ^T Zip 00174 Lic.# 500236 STREET CITY STATE Owner J • `�•�J • ,0NS T. CO. INC Address SAME Architect -)AVE GOSSELYN Address SAME Sire New Area: Ft. Front Overal16? • 3Ft. Deep Overall 3 4 . 5 Total Area 2 4 300 #Garages 2 Size of Lot 2 8 9 334 S . F Dist. from Street Line 55 Lavatories 4 4 Bathrooms Rooms 1st 2nd 3rd Purpose of this Permit CONSTRUCTION OF A SINGLE FAMILY DWELLING City Water 13 Well 11 Septic 11 Sewer a Use Group "y Construction Type Approved by y�- Date BD1A 11/88 I h reby agree to conform to all the requirem nts of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zone in which this building and its use is allowed. SignedDART 'TILL REALTY INC 3f : a I hereby apply for a Certificate of Occupancy for the work described in this application for permit. Signed)ART HI L REAL TY IiQC 3Y X, - VUJ J4,) —DO NOT WRITE BELOW THIS LINE \j it — INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation Plumbing Permit# Inspections: HVAC Permit# 7✓r� Inspections: Electrical Permit# 7 o Inspections: Sprinkler Permit# Inspections: Location of job AFFIDAVIT Additional Fee .... Q.:Q 0 �Z • w State of Connecticut / County of Hartford I JG A.k Q.e, `�T '.�.................... ....................... Owner gent under of A for binding erected Contractor Permit No. ...2.09.4.2................. issued by the Dept of Building of the'Town of South Windsor being duly sworn.make oath and say that the actual cost of the completed work authorized under said permit did not exceed the meat current accepted BCCA value of 3.•.Q Q:. . . . . . . . . . . . Signed ... . . . :�.--. .......... .J. Subscribed and sworn to before me this .... .........day of A.D.19 .�,7. Estimate Cast:3 87 1 100 . 00 J ' Difference. S 29 ,243 . 00 _ Norcry Fu Q Inspection / Approval Date By Appl Code Description Due Whom Code Comment --------------------- ---------------------------------------------------------- 93-20942-B 75,000 BO1 FOOTING 09/20/93 JFH A B02 FOUNDATION 09/24/93 JFH A P02 UNDERGROUND 10/06/93 JFH A WATER TEST E01 SERVICE 10/12/93 JFH A RELEASE ISSUED B05 FIREPLACE/CHIMNEY 10/21/93 JFH A B03 FRAMING (ROUGH) 10/25/93 NAB A E03 ROUGH 10/25/93 NAB A P03 ROUGH 10/25/93 NAB A B04 INSULATION 10/27/93 NAB A PO4 GAS TEST 11/15/93 JFH A AIR TEST B10 FINAL O1/14/94 JFH A 93-8755-H 5,300 93-9301-P 1,900 94-8807-H 1,900 93-12782-E 3,000 Total Est Value 87, 100 Dwelling 2,300 85,514.00 Basement 1,159 11,532.05 Garage 484 5,687.00 Smoke Det 3 225.00 BOCA Value 116,342.60 Difference 29,242.60 �aa' 0 • CERTIFICATE OF OCCUPANCY CHECK LIST Applicant Bart Hill Realty Certificate of occupancy P cY- 04 D It .-:k Address 658 Ellington Road Bldg. Permit No.__ Ccn a Lot No. 67 Rim ie rive Date Reviewed Project DART Rev'awed By t2 3 Date Submitted 12-07-93 :prove Denied . z As required in the Zoning Regulations, no Certificate-of-Occupancy shall be issued until grading plans have been comulied with and aDuroved by the Tcw-n Engineer. The minimum requirements shall include: P_ouroved Denied N/A ze-__ 1 . Aoercved building perm. -it plan . ,lzaae--� 2 . Finish grading per approved build.ing permit plan. 3 . Site work; i .e. trees s:,-.,bs dumps ters, regu=red par tiinc � . L'tili ty location a . Sanitary sewer b. =oundation drain C . e1 cC6r-C-1 & tel e:";hc = C. �:ater e. otnmr 5 . Sewer connection chzrce paid. 6 . _:ro:riate certification 7 .��8�93 Eo��d i:�g 1 8 . P1?rzing & Zoning r Sewer Permit No.- Pavement Excavation No. &M COMMENTS: 2.S 0 0 11W� 24e,,4 -X,4 BUILDING PER11IT CHECK LIST -.,— Applicant E-rt u; 1 1 RAa l t,z]aC, , Building Permit No. 03 zyq V. Address 658 El I i n Tntn PrI �., W Date Submitted 0 m. ) Lot No. 67 #135 imfiel_d Dr;vP Reviewed by ProjectDart Hill Estates PnAcin 1 DateT�3 In accordance with the Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include : Approved Denied N/A V 1. Name, address & phone number of owner/ applicant. 2. Name, address & phone number of plan preparer. 3. Zoning information - i.e. zone, open space, fl oodway, etc. _ 4 . Plot plan at 1" = 40 ' scale. a. Subdivision reference, abutting properties, etc. _ b. Easements of record. s distances, c. Lot descrip bearintion, g , building lines, area, etc. . d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate. e. Building location with dimensions. Elevations of proposed finish floor, garage floor & center line of road at driveway. f. Elevations of gravity drainage systems, sanitary & foundation drain at the house and the street. g. Tentative utility location gas, electric, water, etc. h. Title block with name and address of preparer, date appropriate certification, live seal and signature. 5 . Sedimentation and erosion control. 6. Special Planning & Zoning, Inland/Wetlands considerations. (Plans on file w/Town Clerk) BUILDING DEPT. PZC IWA/CC WPCA OTHERS COMMENTS: f PERMIT DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is hereby : TOWN OF SOUTH WINDSOR BUILDING INSPECTION DEPT. APPROVED DISAPPROVED 1540 SULLIVAN AVENUE 644-2511 Ext. 230 1 ate i Application must be printed or typed 1 . LOCATION OF JOB FEE SCHEDULE No . Street $ 0 - $19000 - $10.00 Floor Apt . No. Over $1 ,000 - $10.00 per $1 ,000 or 2 . OWNER ���� L, LTA' fraction thereof 3. A D D R E S S b% EL Tur Tau 90. CZ UoO-7 4. APPLICANT m - (JJ EC EC- 5. ADDRESS C: 6. f 2jcjC 1(4 6, ESTIMATED COST $ , � 7 . IS T11IS A CONTRACT COST V Yea 8. FEE ENCLOSED $ 9. TYPE OF BUILDING : RESIDENTIAL COMMERCIAL 10. TYPE OF JOB : 6--�Origin 1 Installation Alteration/Addition/Repair RD 3A 11/88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11. LOCATION OF JOB AZT (,7 Q,I,-n-fJd NO. STREET APT. NO , 12 . TYPE OF INSTALLATION an+1 cj 13 . SIZE OF MAIN FEEDER 14. NO. OF LIGHT LOOPS 15 . NO. OF HEAT LOOPS_ 16 . NO . OF POWER LOOPS 17 . NO. OF LIGHT OUTLETS c> 18 . NO . OF HEAT CIRCUITS 19 . NO. OF POWER OUTLETS_ 20 . NO. OF CONVENIENCE OUTLETS 21. NO. OF HEAT CIRCUITS 22 . NO. OF POWER CIRCUITS Q 23. NO. OF LIGHT CIRCUITS 24. SIZE OF HEAT CIRCUITS 25 . NO. OF MOTORS --' 26 . NO . OF PANELSl� 27 . TOTAL WATTAGEaI /l-1t-) 28 . NO. OF POWER FEEDERS 29 . NO. OF SWITCHES 30 . A/C LOAD 31. SIZE OF POWER FEEDERS / �- 32. NO. OF FIXTURES 33. TOTAL HORSEPOWER_ 34. NAME OF SUBCONTRACTORS AND THEIR TRADES 35 . REMARKS AND FURTHER DETAILS : LICENSE NO. SIGNATURE OF APPLICANT DATE PHONE NUMBER: e2�- S79c:?le Lot No. 4�L- Building Permit Temporary Service Permanent Service Y Pursuant to Permit No. This Certifies that the Electrical Work for which the above named Permit was granted has been duly Inspected and is hereby approved. 'Owner di'Al S' Electrician -117�Street CiI - I6 19-A- Inp Inspector Lot No._ Building'Permit Temporary Service / Permanent Service Pursuant to Permit No. This Certifies that the Electrical Work for which the above named Permit was ranted has been duly inspected and is hereby approved. 9 Owner Electrician Street_ 1930 Buliding Inspector Lot No. ' a Building Permit `1 A - Temporary Service CPe:rm=anen1ic� Pursuant to Permit Na �Z Z This Certifies that the Electrical Work for which the above named Permit wad'granted has been duly inspected and is hereby approved. Owner Electrician i Street � e AuIlding Inspector i PERMIT NO. 950/ DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT Application is hereby : TOWN OF SOUTH WINDSOR BUILDING INSPECTION DEPT. APPROVED DISAPPROVED 1540 SULLIVAN AVENUE A0 J6/ � y 644-2511 Ext. 230 D it to B ng Inspector Applications must be printed or typed 1. LOCATION OF JOB: 1 FEE SCHEDULE 2. OWNER: f $ 0 - $19000 - $10.00 3. ADDRESS: Over $10000 - $10.00 per $1 ,000 or 4. APPLICANT: fraction thereof 5. ADDRESS: 6. EST. COST: $ Q O 7. IS THIS A CONTRACT COST? YES "0- 8. FEE ENCLOSED: $ wo 9 9. TYPE OF BUILDING: 1---- RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: j/6RIGINAL ALTERATION INSTALLATION ADDITION REPAIR BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: GENERAL PLUMBING 12. KIND OF INSTALLATION: 13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS STYLE 15. NO. OF URINALS STYLE 16. NO. OF BATHTUBS�T 16A. NO. OF SHOWERS 17. NO. OF LAVATORIES 18. NO. OF SINKS_ 19. DISPOSAL 19A. DISWASHER '�- 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS/_SIZE 3 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK? 31. SIZE OF WATER MAIN Z _ 31A. SIZES OF WATER PIPING & RISERS 32. REMARKS AND FURTHER DETAILS WATER HEATER 33. TYPE 34. MANUFACTURER TANKS SAFETY DEVICES TEMPERATURE 35. CAPACITY 39. RELIEF VALVE 36. TEST PRESSURE LBS. 40. MANUFACTURER 37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE 38. TYPE 42. MANUFACTURER boa LICENSE NO. DATE SIGNATURE OF APPLICANT PHONE NO. 7 Wc2 f 13 FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: (NO. D TOWN OF SOUTH WINDSOR EST.0 BLDC. PERMIT N0. 1540 SULLIVAN AVENUE FEE SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 $ 0 - $1,000 - $10.00 /3� $1000 or fraction LOCATION OF BUILDING thereof - $10.00 n— O ADDRESS TOWN PHONE NO. LL <J C, c>2, - � HVAC CON CTOR ADDRESS TOWN PHONE NO. TYPE OF SYSTEM: HEATING TYPE OF BUILDING: RESIDENTIAL_ A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT_LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC A/ WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM rGAjA4T-2-2,au0 ELECTRIC KW WOOD _ OIL TANK - SIZE & LOCATION: INSIDE_ OUTSIDE CAPACITY LPG TANK - CAPACITY_ EXISTING RADIATION_ ADDITIONAL RADIATION TOTAL RADIATION_ DESIGN TEMP. OUTSIDE °F INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS (BTUH) (HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): Y�& (-ay�� 0,- C �z 7z?d da GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE F TOTAL HEAT GAIN (BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT): TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) (PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building odes in the performance of such work. FURTHER DESCRIPTION OF WORK: ' STATE LICENSE - NAME b TYPE # DATE FGNATURE OF APPLICANT 3 PROVED DATE BD 4A 11/88 I = B= R CALCULATION SHEET 1503 (Modern Method) Copyright 1971 by The Hyd ranks Institute WNER ADDRESS al DESIGN TEMPERATURE DIFFERENCE F. DATIk'�,k":;' COL.A COL.O COL.C COL.D COL.E COL.F COL.G 1 ROOM O H L W H L`/ W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS,FT. U (� �y /r �� @TUN pv F t of 3 LENGTH EXPOSED WALLS,FT. < Z ` Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA IL •TUN OTUH STUN STUH STUN 5 WALL CONSTRUCTION IT able 9.Line eI 3 x H) f O Q O /(w ROOM LIN. FT.OF�(� 0 TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED (Bottom f table used for Line 5) �C�' C C / [f Q G o 7 CEILING CONSTRUCTION ,% /// C 0-5 IT able 9. L x W) `-- �, � - '{ V �� Ur E'�� g FLOOR CONSTRUCTIONt / (Table 9, L x W or Lin. F t) E (I!ZZ 9 COLD PARTITION CONSTRUCTION P (Table9, L x H) �Z� G 10 c 1 Wen I With Openings) (�/ `, d H_ '2 J 2 Wells(With Openings) :X e g I f C71 _ - 3 Wells IWiIh Openings)or Ent.Han 5i 11 TOTAL STUH AT 70F TEMP DIFFERENCE' "60 S U a 1")d , 12 TOTAL STUH AT DESIGN TEMP. DIFFERENCE K 2zL -- COL.A COL.® COL.H COL.I COL.J COL.K COL.L TOTAL STUH TOTAL 1 ROOM — -- -�— fi ---- � L OF BUILDING RADIATION AT SELECTED O H L W H L W H L W H L W H L W DESIGN TEMP.* 2 ROOM DIMENSIONS.FT I-' ` DIFFERENCE U -4 ! 3 LENGTH EXPOSED WALLS, FT. < 4 WINDOW AND OUTSIDE DOOR AREA to OTUH STUH STUH STUH STUH 5 WALL CONSTRUCTION r "INCREASE BATHROOM IT able 9,Line 3 x HI a ��(T'j (� -�( D 5 0 d - © �� (� TOTAL 20% 6 TYPE OF GLASS (Bolt m of table used for Line 51 7 CEILING CONSTRUCTION +C tFOR CONCRETE FLOOR ON OR LL AT (Table9, L x WI - o �v O Z/ 0 GRADEOLE EL, O USE LINEAR 6 FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE I T able 9,L x W or Lin Ft.) 9 COLD PARTITION CONSTRUCTION ITable 9,L x H) 10 c 1 Well(With Openings)o 2 Walls IWith Openings) p J --- --- -� v�— ------- - �� Ov "'Z 3 Walls(With Openings)or Ent. Hall r�. - 11 TOTAL 13TUH AT 70F TEMP DIFFERENCE' -3,;70 D ��b 2 d g6 c) _ A�� 12 TOTAL STUH AT DESIGN TEMP DIFFERENCE _ '2 �Z� —1�✓y— FORM 1503 This form Is available fr m The Hydronics Institute 36 Russo Place,Berkeley Heights,N J 07922 FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: 10/20/93 (N4. 7= — TOWN OF SOUTH WINDSOR EST.COST: $5,300.00 BLDG. PERMIT N0. D 1540 SULLIVAN AVENUE FEE _ SOUTH WINDSOR, CT 06074 FEES: V _ 644-2511 - Ext. 230 $ 0 - $19000 - $10.00 $1000 or fraction LOCATION OF BUILDING Lot 67, .135 Rimfield Drive thereof - $10.00 Dart Hill Realty, Inc. , 658 Ellington Road, South Windsor, CT (203) 644-8137 OWNER ADDRESS TOWN PHONE NO. R & E Heating & Cooling, Inc. , 310 Nutmeg Road South, South Windsor, CT 282-7782 HVAC CONTRACTOR ADDRESS TOWN PHONE NO. TYPE OF SYSTEM: HEATING TYPE OF BUILDING: RESIDENTIAL X A/C X COMMERCIAL VENTILATION BUSINESS _ INDUSTRIAL HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT BS. HYDRONIC WARM AIR T RADIANT HEATER (INCLUDING WOOD COAL BURNING STO TYPE OF FUEL: 0 GAS IN-PUT EL C KW WOOD COAL OIL TANK - SIZE & LOCATION: OUTSIDE_ CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ITIONAL RADIATIO TOTAL RADIATION DESIGN TEMP. 0 OF INSIDE OF DIFF °F TOTAL HEAT (BTUH) a (HEAT LOSS SHEET CCOMPANY APPLICATION) DES ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE 88 OF INSIDE 70 OF DIFFERENCEI�L2F TOTAL HEAT GAIN (BTUH) 37,819 (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): Heil BH5048SKA Blower Coil; Heil CA5548VKA Condenser TONNAGE 4 COOLING CAPACITY (BTUH) 48,000 IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT): None - TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) (PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: Installation of central air conditioning system sized for 4 tons of cooling. 305874 D-1 10/20/93 JA STATE LICENSE - NAME & TYPE # DATE SIGNATURE OF APPLVANT l6 93 APPROVED DATV BD 4A 11/88 I - 8 s R CALCULATION SHEET 1503 (Modern Method) Copyright 1977 by The Hydronics Institute WHER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL.A COL.B COL.C COL.D COL.E COL.F COL.G 1 ROOM _ li O H L W H L W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS, FT. ~ U 8TUH per F lot 3 LENGTH EXPOSED WALLS,FT. < Radiation Selected 1 WINDOW AND OUTSIDE DOOR AREA IL •TUN •TUH &TUH BTUH •TUH 5 WALL CONSTRUCTION (Table 9,Line 3 x HI ROOM LIN.FT.OF TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED 18 ttom f table used for L me 51 7 CEILING CONSTRUCTION C (Table 9,L x WI g FLOOR CONSTRUCTIONt D— ITable 9, L x W r Lln. F t) E 9 COLD PARTITION CONSTRUCTION F (Table 9, L x H) G 10 _0 1 Wall(With Openings) O — H c 2 Welts(With Openings) D X ~ 3 Walls IWith Openings)or Ent.Hall 11 TOTAL BTUH AT 7OF TEMP DIFFERENCE' J 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE K >1 -- - -— — L COL.A — ,-_ --^ COL.8 COL.H — COL.1 COL.J COL. K sCOL.L TOTAL BTUH TOTAL 1 ROOM OF BUILDING RADIATION Q AT SELECTED O H L W H L W H L I W H I L W H L I W DESIGN TEMP.• 2 ROOM DIMENSIONS,F T 10' DIFFERENCE U 3 LENGTH EXPOSED WALLS, FT. 1 WINDOW AND OUTSIDE DOOR AREA LL STUH •TUH 8TUH BTUH BTUH S WALL CONSTRUCTION •INCREASE BATHROOM ITable 9,Line 3 x H) TOTAL 20% 6 TYPE OF GLASS 18 tiom f table used f r Line 51 7 CEILING CONSTRUCTION - tFOR CONCRETE FLOOR ON ( GROUND OR FILL AT Table 9, L x WI GRADE LEVEL,USE LINEAR FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE (Table 9,L x W r Lin Ft 1 9 COLD PARTITION CONSTRUCTION ITable 9,L x H) 10 _c 1 Well(With Openings) 0 ----- ------- --- -~-- - - ------- 2 Wells(With Openingsl A X _ 3 Wells(With Openings) or Ent. Hall �J --- -�--- -- -_---- - ---- — I TOTAL 8TUH AT 7OF TEMP DIFFERENCE' 12 TOTAL 8TUH AT DESIGN TEMP DIFFERENCE i This 1 rm Is available from The Hydr nlcs Institute.36 Russo Ple<e,Berkeley Heights,N J 07922 FORM 1503 DETAILED REPORT FOR ►ENTIRE HOUSE Prepared For: Prepared By: Jpi R & E Heating & Cooling 135 Rimfield Drive Job Name: Dart Hill Estates South Windsor, CT 06074 �:*�K�c�K*�c*�c****�c�c�c�c*�K�c:K*�****�c*�c�*�c**�K*�k**�K********�c�*�*��c*=:Kx.����'��'y_,,•�.,,.�..►.�:** EXPOSURE `ASS Y NORTH NE/NW EAST SOUTH SE/SW WEST HOR7 . TOTAL -------------------------------------------------------------------------- AREA ; 6; 0 ; 145: 0; 0 ; 135 ; © ; 286 : -OOLING ; 81 ; 0 ; 6 ,296 : (D ; 0 ; 5,862 : 0 ; 12 ,239 : --EATING 241 ; 0: 5,8171 o: 0: 5t416; r ' � ;. 741' -------------------------------------------------------------------- ---- ALLS NORTH NE/NW EAST SOUTH SE/SW WEST --: ------------------------------------------ ------------------ aREA ; 3091, 0; 429; 696; 0; 6ItI Q, ` -_OOLING ; 214 , ell 2961' 481 1' oil 4.26 3 17� -TEAT ING ; 875; 0 ; 1 ,214 , 1 ,970 , 0 't 1 ,747 ' 5,S06 ; DORS NORTH .- NE/NW - EAST SOUTH SE/SW WEST TOTAL;" --- --- ----- ----------------------------------------------------_----- AREA �_. , 21 ':.� ,_ 0 y 42 t 0� 0 1 �L"�_ i 63 1, .OGLING- ; -: = 66; 0 . 132; 0; 0; 01 1,991, -iEATING 271 , 0; 543 , 0; 0; 0 ; ; 814 , --.----------•----------- --------------.-----.--..------------ 'e-...�- i _OOR AREA COOLING HEATING 2054 ; 0 ; 0 ------------------------------------------------------------------------ ----- -ILING AREA COOLING HEATING _w2,302 a_ - ---------- _---------------_------ _ -_-=-=--_=-- ------------= _ _ MISCELLANEOUS COOLING LOADS --------------------------- ople Sensible Load 6 ,075 Latent Load Q ,33 -ghts & Appl . Load 6 ,143 Latent Safety 8,9'-'uh --ntilation Load 0 _.ct Heat_ Gain"---... _ 0 ifiltration Load 787 nsible Safety- Btuh 1 -9385 _ -'.)'TAL SENSIBLE LOAD 29,092 TOTAL LATENT LOAD, 8,728 . r Changes/Hour- 0.50 ._Temp . Swing Mult.- 1 .00 A W Total Cooling Load 37 819: BTUH Or, 3:iGTons **=` ��r'�.y 7= n. ..c y":F yr• ;E i�P"t��,,fig:•�,,f,s.'ti,x>.• :r, � -�.:k•.," ,r, _. -- -:d°.�,. .,y. �•4 Syr ..,1 a-' :ts - - -�=33r'°- � -.E':;,°ram -.e,^y �• 3% •" "..+,�. ,.�' a::'•.....s d` - - - .ci a,,a c i�' w!t'-rt4Y ''Y�.;,:Y.ar•:a,!•t!1't':'�,._.S.a+.e�h k��rc'.flM"_ _ y...•P��`:�y�s^�� -3;Ya-`�,_ �7,�'n_''"��_-3•e_F��".-" �}`' .a r.�J.,s,��a.m '1 t¢., '�•qrr��' .'.S.'a` s� y,,.n-ors.'-- __ r� ���'�;�r'_'x -- � :'�,.:11..1.,:'�'F. ,:Zy;.�'.i: <, 4:�'���:�.a.:::qF-s.".-.`.+w,r..yet•..' '�.�-- -- �-..:.y, �.±'., ,-�' �. `�.-. •4 �s.,"�;; ;,,rc_-��.' ,.,_�.x• u5.` =m-•,J•� �.�g^sc- _-;^y,,tA'..{�qXRw+I=-?`*_«F-.tei.r�r_��.�•_L5-+..r_r.,xfi,-•r�.+_'VrEE#r�4j�g�,'egy%rim4;,r=`-....'_--�,-�'`��:^?°:r,-.r�f"r.�-�t_-.e+�"'=�t��--itt.d�r_ix'�"sY4y-•+:?f==•-:ho,r5't_p:•;•�=i-•.'.^�^+�y,ri"`^=--4�=-Y�v".'1.`3':_a_.�'Y 1._�F3"a.0t'—.`-?:>�-4po`.-y iayr+'.-.�.,-s'_e�a e.,.":—_.-:-qp.—�:-r'_.�y—.�?'.�•'-y9f.-':C en—�t�'?-=_—.._—-—,°..�".-n�`r'_•;r4 4 Fe,454 "-HEATING',, Hhl�`,-'E.$-z'•A=--F=vT"<AI4lwife::N"=.aSo-��•Gr,:.."..�t•L..�.—.�,:^,7.'�O--:'- .Ar{^"..D,—.?-%.-.aA.S—�...� ,- MISCELLANEOUS Vw - a Vent Load aio ,699 �.`a+�-i..•+_.>«"_'.�.�, ;..,�,-,:..--_•-'-�;s�_{..---.4`'Fy-:-�"....�'-yq_-M_nr;:6.;.x-bs.`wf"§A'±'�•®•..e`t-.�:•d.-Y{�.yu.a°`''_i^��-'_3' uc ( e,ayt,t#.L oss, -.-.-Safety.. Stuh , -,1rTk;-�e}5tt-.5t 'i-_�r?n,ras"3+a"n0i,• ''=+ - -•�...�:s,-;K�s`_� « =4- '.a •• "- `>' - ,x:-'uw1,i�.+ic�A. a4:'V� � W � - �. s•.+1""q•om-r .,;,p - - .,._ - � '"?A .-tea -gc,�a .,rta: x�: -a,'b. �P '��ta.::eiR-�L�. .,�:u.,.._,,.K`.�.-._' _,..-.��_.,r: ?.y:�.ec.k fad:�:''..:_s�., ���- �t��'+ _- - „ ...'.�• _�.-. _ �•.�fi'L-+_ ua, -',., _ TTotal'�He_ating_ toadM, TUH -v- %h`--a,'�..y��y,�y}t"-�d'.'^. `¢i_`_r,.u;=''..,v8'i�sT `s.-`. -__'` r '`r. #• .m _ _ ° - 'irc_-L a*;'. i"E �'�K'�!^ .iS"'- �.. -..'i.,fF��r ,_ _ _`-. - �-+�r ..�- •alp- .,aG -'U x;,tr- „ - w�r�at. ,. . ..- ..._-sw.yw4'•+e...:..e...:r-,"»_+.v...�.,.w..-r..' .. -.__.__ _ -:- tr -•yw••..w+ _ '.-.yF.•+...,m.,.....«s .w. - ._,.,,...,a.r., _,.. _ f_ .`, .,. ._.. .,✓ ,..r ry a:s.-.;+,-�n.x+.w.,,r.*.._ _ ..--.. �. ....����;�'�.ss.'-vr'-^-':ryi.�.'.: -_._ «_._.___---___"�__•_�- ,.+x:� a"..-..,.--�..,r,aa^-'.'--�..•_-.•'a...a �.-_ '....,_s.. _`. _. .._. . . - .'•-• � , . - -`.!'f"�T^_T•-•-.•,n;,'...,... .�'_, '�'.,.: _ - 'W.. ",'�-�"1.._:5:"�" r�"",ilt'47"''lE:°7!!'F"tF' S. �. ..a_r •'+.';•vri:,h-�jk:-w f-s, L.=_,_ _. _ _ •�r., __ r:� i - .. .' -.__.� =•• __,__ __ , � _..f-�..c�ew s;r -1^�.6...:- Room Heating Heating Cooling Cooling Name BTUH CFM BTUH CFM ---- ------- ------- ------- ------- Living Room 4 ,842 208 4 ,046 195 Family Room 3 ,451 148 3 ,279 158 Dining Room 2 ,852 122 30372 162 Kitchen _ 4 ,132 177 3 ,672 177 foyer 3,198 � 137 2 ,842 137 Bedroom 1 _ 3,517 _ _. 151 2 ,997 Bedroom--2 -= -- - _...-3 9-401 _ - 146 - .2 ,703 130 --------- - --- Bedroom 3 5 ,325 228 3 ,642 175 Bathroom 1 ,933 83 2 ,540 122 ------- ------- ------- ------- 32 ,651 1 ,400 29 ,092 1 ,400 HEATING DELTA T 21 .2 COOLING DELTA T 18 .9- NOTE : *** Calculated Airflow is based upon load requirements . Verify that airflow calculated is compatible with selected equipment requirements . *** Press (ENTER> to continue .