Loading...
HomeMy WebLinkAbout128 Rimfield Drive Build ng SPEC IONs _ APPLICATION FOR BUILDING PERMIT Plumbi y 'July HVAC '`� ''` 128 RIMFIELD DRIVE Date: Sprinkl r � Estimated Cost 759000 . 00 Electric $ Zoning �h>.q 19,4 Permit Fee$ 7 5 0. 0 0 Affidavit ��� NO. 2 0 7 9 4 Occupancy Fee $ 3 . 00 Eng. Dept. Fire Dept. COMPLETE RED BOXED AREAS. Total Fee $ 753 . 00 TYPE OR PRINT ONLY Health Dept. SIGN ON REVERSE SIDE. �`t Approved for CO: (Additional Cost) $ 3 �$ TO BUILDING DEPA TMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Y(-(T/�7 Job Location '128 RIMFIELD DRIVE S O. iJ I N D S 0 R CT Lot No.6—Side of Street L Zone RR Applicant HART :SILL REALTY INC Tel. # 282-0628 Address 658 ELiJINGTOtN RD SO. WINDSOR CT Zip 06373 Lic.# 500320' STREET CITY STATE SAME Owner 1J •M.1J . CONST. CO. INC Address Architect DAVE GOSSELYN Address SAME Size New Area: Ft. Front Overalls 8• BFt. Deep Overall 34 . 2 Total Area 21170 #Garages 2 2 2 5 0 0 115511 Lavatories 4 4 Size of Lot Dist. from Street Line _Bathrooms Rooms 1 st 2nd 3rd Purpose of this Permit CONSTRUCTION OF A SINGLE FAMILY DWELLING City Water Well 0 Septic 0 Sewer 11 Use Group )eV Construction Type Approved by Date BD1A 11/88 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zone in which this building and its use is allowed. Signed (CART HILL REALTY INC BY :Q- I hereby apply for a Certificate of Occupancy for the work described in this application for permit. if Signed DART HILL REALTY INC BY : —DO NOT WRITE BELOW THIS LINE— INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation Plumbing Permit# 13 � Inspections: HVAC hermit# e�? q`U Inspections: Electrical Permit#^ 9-2? Inspections: Sprinkler Permit# Inspections: Location of job AFFIDAVIT Additional Fee .$3 3.Q...Q.Q......... State of Connecticut County of Hartford i .de q w �-...Wulf'-�-.............. . . ...�'. .o�,?j a--/Ili ee, Zy�°Cgpent for building erected under ctor 2.0.79.4.... .... .. . .... issued by the Dept of Building of the Town of South Windsor being duly sworn.make oath Permit Na ...... . .. . and say that the actual cost of the completed work authorized under said permit did not exceed the most current accepted BCCA value of . .$114 , 287 . 00... . . . . . . . . . . Signed . .. . . . .. ............. Subscribed and sworn to before me this .... . .... . .. .....day of .... A.D.19 .•/7.. Estimate Cost:S fl I ,8 0 0 _ 0 0 32 , 487 . 00 ... . . . .... ... ........ Difference: S ooa u li p/3� IbQ Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- 93-20794-B 75,000 B01 FOOTING 08/09/93 JFH A B02 FOUNDATION 08/13/93 JFH A B02 FOUNDATION 08/20/93 JFH A E01 SERVICE 09/14/93 JFH A RELEASE ISSUED P02 UNDERGROUND 09/28/93 JFH A WATER TEST B03 FRAMING (ROUGH) 10/14/93 JFH D NEEDS SUPPORT UNDER 2 MICROLAM BEAMS 1ST FLR E03 ROUGH 10/13/93 JFH A P03 ROUGH 10/14/93 JFH A WATER TEAT P03 ROUGH 10/14/93 JFH A AIR TEST B04 INSULATION 10/15/93 MAB A SUPPORT ADDED TO MICROLAM BEAMS B03 FRAMING (ROUGH) 10/15/93 MAB A 2X4 S ADDED TO MICROLAMS (BOTH) B05 FIREPLACE/CHIMNEY 10/18/93 JFH A PO4 GAS TEST 11/03/93 JFH A AIR TEST B10 FINAL 01/14/94 JFH A 93-9311-P 1,900 93-8796-H 1,900 93-12748-E 3,000 Total Est Value 81,800 Dwelling 2,170 80,680.60 Basement 1,332 13,253.40 Garage 594 6,979.50 Smoke Det 3 225.00 BOCA Value 114,286.50 Difference 32,486.50 336 �` j a CERTIFICATE OF OCCUPANCY CHECK LIST Applicant Dart Hill Realty Certificate of Occupancy 0 7� Address 658 Ellington Road,rS.W. Bldg. Permit No. 6 Lot No 62 (128 Rimfield Drive) Date Reviewed Project DART HILL ESTATES Reviewed By W Date Submitted 12-07-93 ..prov Deniedil As required in the Zoning Regulations, no Certificate-of-Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum recuirements shall include: Aocroved Denied N/A 1 . Aocrcved building permit elan. \ 2 . Finish grading per approved building permit plan. 3 . Site wor�:; i .e. trees, d•am_s ters, required parking 4 . Utility location a. c—n_ta--y sewer b. Joundation drain C. electrical & tile"^O d . w a=-r- e. 0-'n r 5 . Sewer connection cha'_"'ce ca_d. 6 . `- :_o _late certlllca t?On �J►�� pip 7 . Bonding 1%�$�93 8 . Planning & Zoning Sewer Permit No. Eq92 Pavement Excavation No. COMMENTS: J BUILDING PER11IT CHECK LIST . licant Dart Hill Realty; Inc-. Building Permit No. 9�' 7c App m. ) Address 658 Ell ; natn: F,d, g W. Date Submitted ( Lot No. 62 #128 Rimfi rNl d nv-j w@— Reviewed by Project Dart Hill F�tatPs-r—Fhse- I Date 2 Subdivision �/ 2'Z-�� �, g2_/SP In accordance with the Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include : Approved Denied N/A Y 1. Name, address & phone number of owner/ applicant. 2. Name, address & phone number of plan preparer. 3. Zoning information - i.e. zone, open space, floodway, etc. _ 4 . Plot plan at 1" = 40 ' scale. a. Subdivision reference, abutting properties, etc. _ b. Easements of record. c. Lot description, bearings, distances, building lines, area, etc. d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate. e. Building location with dimensions. Elevations of proposed finish floor, garage floor & center line of road at driveway. f. Elevations of gravity drainage systems, sanitary & foundation drain at the house and the street. g. Tentative utility location gas, electric, water, etc. _ h. Title block with name and address of Predate appropriate certification, Parer, live seal and signature. 5 . Sedimentation and erosion control. 6. Special Planning & Zoning, Inland/Wetlands considerations. (Plans on file w/Town Clerk) BUILDING DEPT. PZC IWA/CC WPCA OTHERS COMMENTS: 3 • PERMI T T fl DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT �$ Application is hereby : TOWN OF SOUTH WINDSOR BUILDING INSPECTION DEPT. APPROVED DISAPPROVED 1540 SULLIVAN AVENUE S 644-2511 Ext . 230 ate Inspector Application must be printed or typed 1 . LOCATION OF JOB 2 $ OK=(n-� V-.I Qr- FEE $CIIEDULE No . Street $ 0 - $19000 - $10.00 Floor Apt . No. Over $1 ,000 - $10.00 ��� per $1 ,000 or 2 . OWNER ELAuT (f C42,fraction thereof 3. ADDRESS L0 5g LLL7/()f77-0k� p. (��►-�dSa�. CT o(oo�q vt 4. APPLICANT m-W &-ECTf2--r-C--,, + ` 5. ADDRESS P.O. ()Ox (gis VE V2 -r oCoUo(n 6. ESTIMATED COST $ 7 . IS THIS A CONTRACT COST Yes No 8 . FEE ENCLOSED $ Q.Oo 1' ZpZgf4 9. TYPE OF BUILDING : RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: %-�Origin 1 Installation Alteration/Addition/Repair RD 1A 11/88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11 . LOCATION OF JOB L= t►�'1 J NO. STREET APT. NO . 12 . TYPE OF INSTALLATION , � CfQfi±�Gj 13 . SIZE OF MAIN FEEDER 1 0 c) 14 . NO. OF LIGHT LOOPS ( 0 15 . NO. OF HEAT LOOPS_ 16 . NO . OF POWER LOOPS 17 . NO. OF LIGHT OUTLETS 18 . NO . OF HEAT CIRCUITS 19 . NO. OF POWER OUTLETS �- 20. NO. OF CONVENIENCE OUTLETS Q7 21. NO. OF HEAT CIRCUITS 22 . NO. OF POWER CIRCUITS 23. NO. OF LIGHT CIRCUITS_ 24. SIZE OF HEAT CIRCUITS_LL& 25 . NO. OF MOTORS 26 . NO . OF PANELS l 27 . TOTAL WATTAGE 28 . NO . OF POWER FEEDERS 29 . NO. OF SWITCHES 30. A/C LOAD 31. SIZE OF POWER FEEDERS �- 1 32. NO. OF FIXTURES 33. TOTAL HORSEPOWER_ 34 . NAME OF SUBCONTRACTORS AND THEIR TRADES 35 . REMARKS AND FURTHER DETAILS : �S�g� LICENSE NO. SIGNATURE OF APPLICANT DATE PHONE NUMBER: ��� 'F9c;)8 L-ot NOL r euiiding Permit Zu71 Temporary Service Permanent Service Pursuant to Permit No. L7 y This Certifies that the Electrical Work for which the above named Permit was granted has b n duly Inspected and is hereby approved. Owner �M Electrician Alzl Street np Inspector Lot No. y • Building Permit 2��� Temporary Service Permanent Service , -�--- Pursuant to Permit No.-I �� This Certifies that the Electrical Work for which the abovenamed Permit was granted has been duly inspected and is hereby approved. OwnerY Electrician Street t np Inspector Lot No. �- Building Permit Temporary Service Permanent Service G� Pursuant to Permit No. This Certifies that the Electrical Work for which the above named Permit was granted has been duly inspected and is hereby approved. Owner .S -� Electrician Street Ing Inspector k PERMIT ":0. DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT Application is hereby : TOWN OF SOUTH WINDSOR BUILDING INSPECTION DEPT. APPROVE DISAPPROVED 1540 SULLIVAN AVENUE •`i-3 644-2511 Ext. 230 a Building Inspector Applications must be printed or typed 1. LOCATION OF JOB ?Irv, FEE SCHEDULE 2. OWNER: $ 0 - $19000 - $10.00 3. ADDRESS: G� Over $19000 - $10.00 per $1 ,000 or 4. APPLICANT: fraction thereof 5. ADDRESS: 6. EST. COST: $ /�'�j -7 7. IS THIS A CONTRACT COST? YES NO 8. FEE ENCLOSED: $ •d U X.26'11 9. TYPE OF BUILDING: l-- RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: ORIGINAL ALTERATION INSTALLATION ADDITION REPAIR BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: Z GENERAL PLUMBING 12. KIND OF INSTALLATION: 13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS�_STYLE 15. NO. OF URINALS STYLE 16. NO. OF BATHTUBS 16A. NO. OF SHOWERS . 17. NO. OF LAVATORIES 3 18. NO. OF SINKS_ 19. DISPOSAL "-- 19A. DISWASHER -.I- 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS // SIZE -3 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND `t/, M, 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK? 31. SIZE OF WATER MAIN 31A. SIZES OF WATER PIPING & RISERS 32. REMARKS AND FURTHER DETAILS WATER HEATER 33. TYPE 34. MANUFACTURER TANKS SAFETY DEVICES TEMPERATURE 35. CAPACITY 39. RELIEF VALVE 36. TEST PRESSURE LBS. 40. MANUFACTURER 37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE 38. TYPE 42. MANUFACTURER C>4 :Nply /ZlIrl LICENSE NO. DAlt, SIGNATURE OF APPLICANT PHONE NO. Coc/cd,T��� FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: Q✓ (NO. ) TOWN OF SOUTH WINDSOR EST.COST: / BLDG. PERMIT NO. ao 7 1540 SULLIVAN AVENUE FEE 2, - _ SOUTH WINDSOR, CT 06074 FEES: 644-2511 -.Fxt. 230 , ,_ $ 0 - $19000 - $10.00 $1000 or fraction LOCATION OF BUILDING �� �I IM T�L 1�t b2-7 thereof - $10.00 OWNEU ADDRESS TOWN PHONE NO. zrj�7 VA 60 wc� - HVAC CONT TOR AD SS TOWN PHONE NO. TYPE OF SYSTEM: HEATING TYPE OF BUILDING: RESIDENTIAL A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS N-BUT 5?70&0 ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE -30 OF DIFFERENCE fe OF TOTAL HEAT LOSS (BTUH) 410J7/G HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBP ALL HEAT NG EQUIPMENT (INCLUDING MAKE & MODEL N0.): GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN (BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT) : TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) (PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: STATE LICENSE - NAME & TYPE # DATE SIGNATURE OF APPLICANT j APPROVED DATE BD 4A 11/88 I a B CALCULATION SHEET 1503 (Modern Method) Copyrlght 1977 by The Hydronics Institute � /Or OWNER ADDRESS r w DESIGN TEMPERATURE DIFFERENCE F. DATE C�� COL.A COL.B COL.C COL.D r COL.E COL.F COL.G 1 ROOM tL �(� � �� /�/'� Q��(/ O H L W H L W H L�/ W H L H L yy Design Water Temp.��� r�G 2 ROOM DIMENSIONS, FT. U t2wk 8TUH per Fo t of �! 3 LENGTH EXPOSED WALLS,FT. a Radiation Selected O 4 WINDOW AND OUTSIDE DOOR AREA LL BTUH STUN STUN STUN STUN ^� 5 WALL CONSTRUCTION ROOM LIN.FT.OF (Table 9, Line 3 x H) /1�r V U �y� 0 C) 0 TOTALS RADIATION 6 TYPE OF GLASS / FROM LINE 12 SELECTED (Bottom f table used for Line W 7�L' /0� O /� d 7 CEILING CONSTRUCTION C e L / �� (Table 9, L x W) _ 16-2 00 _/ VOb / `/ 1/0 GG g FLOORCONSTRUCTIONt (Table9, LxWorLin Ft) 9 COLD PARTITION CONSTRUCTION f J (Table 9, L x H) 10 C 1 Wall(With Openings) /Z 6 (� /00 ,2? H c i 2 Wells(With Openings) DX k26 - ©o3 Wells(With Openings) or Ent. Hall11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 0 Q Q S D ©OTOTAL BTUH AT DESIGN TEMP. DIFFERENCE L _- COL.A - ---___ _^ COL.B COL.H _ COL. 1 COL_J COL.K COL.L TOTAL 8TUH TOTAL OF BUILDING RADIATION 1 ROOM ¢ AT SELECTED O H L W H L W H L W H L W H L W DESIGN TEMP.* 2 ROOM DIMENSIONS, FT DIFFERENCE 3 LENGTH EXPOSED WALLS, FT. Q 4 WINDOW AND OUTSIDE DOOR AREA LL BTUH 8TUH BTUH 8TUH BTUH 5 WALL CONSTRUCTION *INCREASE BATHROOM (Table 9,Line 3 x H) - -- 0 V G O D C) Q Q TOTAL 20% 6 TYPE OF GLASS (Gott m of table used for Line 5) -- f 7-, �- �� �.�. /, --,/--�-=- ?F O R CONCRETE FLOOR ON 7 CEILING CONSTRUCTION _ ,} GROUND OR FILL AT (Table 9, L x W) OS OLo GRADE LEVEL,USE LINEAR S FLOOR CONSTRUCTION? FEET OF EXPOSED EDGE (Table 9, L x W or Lin Ft) 9 COLD PARTITION CONSTRUCTION (Table 9,L x H) 10 1 Wall(With Openings) O 00 2 Walls(With Openings) G X 3 Walls(With Openings)or Ent. Hall J - - —�- 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' Q� 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE __ FORM 1503 This form is avatlabie from The Hydronlcs Institute, 35 Russo Place,Berkeley Heights,N J 07922