Loading...
HomeMy WebLinkAbout15 Sunrise Lane Eectric G (4 Y /6 70� APPLICATION FOR BUILDING PERMIT Plumbing# l0 15 Sunrise Lane Date: o� WAC # /0 7 No. 26718 � 13c I Sprinkler# FINAL APPROVALS Estimated Cost 5'Ca0 Building R!5Cs '1 11 po COMPLETE RED BOXED AREAS Permit Fee $ 2�k�PD Engineering TYPE OR PRINT ONLY Occupancy Fee $ S Affidavit SIGN ON REVERSE SIDE Appr.for CO. 06 Total Fee TO BUILDM DEPART ,TOWN OF SOUTH WMSOR,CT (Additional Cost) $ The undersigned hereby applies to do work according to the following specifications: Job Location_15 S�A n r i SQ _ Lane, Lot No. Side of Street LQF-f' Zone Applicant B g M GA f&rnr s PS L h - Tel.# Address 37!o S CT Zip v9 # Q0 oZ 10 Owner�4-(Y\ � Address Architect f f nM OQS i A►1 Address Sq.Ft.New Area: 1st FI. 2nd FI. 3rd Fl. Total New Area #Rooms #Lavatories #Bathrooms t 4 #Gara Purpose of this permit: vW ' L City Water d W II ❑ Septic System ❑ Sewer 6� Ins. H.O. S.P. Cent. Area 355 4 4 Basement E141 Garage 99Z Approved by Date Use Group -4 Construction Type 5 6 Rowed /97 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper d' tance from all street lines,side yard lines,and required distances from all other zones and is located in whic building a is allowed. Signed I hereby apply for a Certificate of Occupanc for the work cri in this application for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Location of Job: AFFIDAVIT Additional Fee S — 0 State of Connecticut ss.South Windsor County of Hartford Brian Edwards B & M Enterpirses, In Owner 1 of Agent for the building erected Contractor under Permit No. 26718 issued by the Building Department of the Town of South Windsor being duly sworn,make oath and say that the actual cost of the completed work authorized er said per 'd not exceed the submitted estimated cost Signed4-.&, X)--, Subscribed and sworn to before me this 21� day of VV\ A.D.200" Estimated Cost S 211 ,830 . Difference: $ 4 , 0 0 0 . o ary Public Inspection / Approval Date By Appl Code Description Due Whom Code Comment --------------------------------------------------------------- ---------- **-26718-B 177,500 B01 FOOTING 02/03/00 JFF D CANCELLED WILL RESCHEDULE B01 FOOTING 02/04/00 DCJ A CONTR. TO COVER FOOTING WIHT BLANKETS AFTER POUR B02 FOUNDATION 02/16/00 DCJ A LETTER ON FILE RE:SOIL CLASSIFICATION/DAMP PROOFING ACCEPTABLE E01 SERVICE 03/24/00 DCJ A RELEASED TO N.U. (VOICE MAIL) B03 FRAMING (ROUGH) 05/22/00 DCJ D NO LVL SPECS, INSULATION BEING INSTALLED! ! ! B03 FRAMING (ROUGH) 05/24/00 JFF A E03 ROUGH 05/24/00 JFF A P03 ROUGH 05/24/00 JFF A H03 ROUGH 05/24/00 JFF A RECEIVED MICRO SPECS. B04 INSULATION 05/31/00 DCJ A PO4 GAS TEST 06/21/00 DCJ A LEFT STICKER B10 FINAL 07/26/00 DCJ D FACING OF INSULATION EXPOSED, COMPLETE ELEC. SIDING B10 FINAL 07/27/00 DCJ A APPROVED FOR CO AND CLOSEOUT **-10587-P 13,500 **-16694-E 6,000 Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-10768-H 14,830 **-16909-E 1,500 Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-26718-B 177,500 B01 FOOTING 02/03/00 JFF D CANCELLED WILL RESCHEDULE B01 FOOTING 02/04/00 DCJ A CONTR. TO COVER FOOTING WIHT BLANKETS AFTER POUR B02 FOUNDATION 02/16/00 DCJ A LETTER ON FILE RE:SOIL CLASSIFICATION/DAMP PROOFING ACCEPTABLE E01 SERVICE 03/24/00 DCJ A RELEASED TO N.U. (VOICE MAIL) B03 FRAMING (ROUGH) 05/22/00 DCJ D NO LVL SPECS, INSULATION BEING INSTALLED! ! ! B03 FRAMING (ROUGH) 05/24/00 JFF A E03 ROUGH 05/24/00 JFF A P03 ROUGH 05/24/00 JFF A H03 ROUGH 05/24/00 JFF A RECEIVED MICRO SPECS. B04 INSULATION 05/31/00 DCJ A PO4 GAS TEST 06/21/00 DCJ A LEFT STICKER **-10768-H 14,830 **-10587-P 13,500 **-16694-E 6,000 Total Est Value 211,830 Dwelling 3,544 145,020.48 Basement 2,147 26,622.80 Garage 992 12,300.80 Smoke Det 7 525.00 BOCA Value 208,450.06 Difference (3,379.94) SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT / Zb-oo.asrs�o' 15 SUNRISE LANE LOT_# 2 Reviewed By y (Engineering) B & M ENTERPRISES Date Reviewed X d/Denied 376 PLEASANT VALLEY RD,SOUTH WINDSOR,C Reviewed By anning) BP_#_26718_ Ph #_(203)528-5418 Date Reviewed �e Approve Denied Date Submitted 00/00/00 ***** FOR C of 0 *** As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1. Approved building permit plan 2. Finish grading per approved building permit plan 3. Site work; i.e. trees, shrubs, dumpsters, required parking 4. Utility location; a. sanitary sewer/septic system b. foundation drain C. electrical & telephone d. water e. other 5. Sewer connection charge paid Qliiavao 6. Appropriate certification 7. Bonding 8. Planning & Zoning/ sw Yz-.Q A,,,,,., Inland Wetlands Considerations A. Lighting B. Signage Freestanding Wall C. Fee in lieu of Open Space Sewer Permit No. A144L T Pavement Excavation No. i 00 r \ COMMENTS: 01 POO QFP�s4? Z� �o✓••ova�'d" A -------- -- � T. �✓ icovls�� ✓ TC "`� ®�t�' Crl Z 1006f0 6 z = s ��tl Y SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 15 SUNRISE LANE LOT_# 2 Reviewed By +.LS _ (Engineering) B & M ENTERPRISES Date Reviewed ® ov /Denied 376 PLEASANT VALLEY RD,SOUTH WINDSOR,C Reviewed By a BP_#_26718_ Ph_#_(203)528-5418 Date Review pprov Date Submitted 01/31/00 ***** FOR BUILD N PERAothe ** In accordance with the Zoning and/or Subdivision Regulations, prior building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include: Approved Denied N/A 1. Name, address & phone number of owner/applicant 2. Name, address & phone number of plan preparer 3. Zoning Information - i.e. zone, open space, floodway, street address. 4. Plot Plan at 1" = 40' scale a. Subdivision reference, abutting properties, etc b. Easements of record C. Lot description, bearings, building lines, distances, area, etc. d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate e. Building location with dimensions. Elevations of proposed finish floor, garage floor & centerline of road at driveway f. Elevations of gravity drainage systems, sanitary & foundation drain at the house and the street g. Tentative utility location (gas, water, electric, septic system, etc.) h. Title block with name and address of preparer, date, appropriate certification, live seal and live signature consistent with the Board of Registration requirements. (P.E. & L.S.) S. Sedimentation and erosion control 6. Special Planning & Zoning, Inland/Wetlands considerations (Plans on file w/Town Clerk) MMENTS: DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: ` BUILDING DEPARTMENT C.-A 1540 SULLIVAN AVENUE Bldg.Permit# --42NOc) 644-2511 ext. 230 ��/ ate Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= $13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. P APPLICANT APPLICANT ADDRESS APPLICANT PHONE# O VA N S 4t OWNER OWNER ADDRESS ,'z2-G OWNER PHONE �v ESTIMATED COST$ � ►mil * V " IS THIS A CONTRACT COST? kYes 0 No F FEE ENCLOSED$ �I •A OR-CO TYPE F JOB: New Installation t E3 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A ❑RESIDENTIAL BUILDING PERMIT APPLICATION? ❑ YES ❑ NO ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL ❑ INSTITUTIONAL ENGINEER'S NAME PHONE ❑FACTORY ❑ STORAGE ADDRESS ❑GARAGE ❑MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF SERVICE SIZE OF MAIN CONDUCTORS NUMBER OF METERS_� NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS _ REMOTE DISCONNECT REQUIRED? ❑YES ❑NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. l6 / CONTRACT RS LI ENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE �•2 � INSPECTOR DATE w2 TIME A!Yl LOCATION ZS- 2-G-718 INSPECTION: CODE: RESULT(D/A) : BUILDING: ELECTRICAL: _ PLUMBING: F i HVAC: E OTHER: B & M , Box.1060 South Windsor,CT.06074 July 25, 2000 Town of South Windsor, Building Department: Please be advised that Shea Electric has been released as the Electrician from Lot 2, 15 Sunrise La. He has refused to complete the finish. Rosa Electric of Vernon will be taking out a new permit, and completing the work, which consists of installing fixtures, and some plugs and switches. Sincerely, Aa Brian Edwards �c+ut11 VVIndSor President iL.L�ING DEPAR- T DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT u;�s TOWN OF SOUTH WINDSOR PERMIT# Pr e Application is hereby: // BUILDING DEPARTMENT / c� I 7 l 1 ::PROVED 1540 SULLIVAN AVENUE Bldg.Permit# oo 1�Ige— 644-2511 ext. 230 (c -7 1 Date Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: e �h r� c �.CP NC $0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= $13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT — , f k <)3O 9/4 ! APPLICANT ADDRESS / S�cj �!'k A 0 r i APPLICANT PHONE# i OWNER , 1`� nlcrnriSe � OWNER ADDRESS Oo !D Co D OWNER PHONE S 70 r-- 9/0 0 ESTIMATED COST$ / D Q „d Q `;�► IS THIS A CONTRACT COST? XYes O No FEE ENCLOSED$ � Q Q TYPE OF JOB: i dSOR.C0� 0 Original Installation ! f 0 Alteration/Addition/Repair Revised 8/99 i f APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A ❑RESIDENTIAL I BUILDING PERMIT APPLICATION? ❑ YES ❑NO ❑BUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY ❑EDUCATIONAL ❑INSTITUTIONAL ENGINEER'S NAME PHONE ❑FACTORY ❑ STORAGE ADDRESS ❑ GARAGE ❑MIXED USE CITY STATE ZIP (mauler please spt6f ) TYPE OF INSTALLATION/WIRING METHOD SIZE OF MAIN FEEDERS AND RATING OF WIRE USED NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? ❑ YES ❑NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK i h r e r-o tq w r- r° N THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE & ) DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT Application is hereby: TOWN OF SOUTH WINDSOR PERMIT#Q�g BUILDING DEPARTMENT APPROVE 1540 SULLIVAN AVENUE Bldg.Permit# J1 00 644-2511 ext. 230 o2Co f7 I bale ing Inspector Application must be printed or typed FEE SCHEDULE Location of Job: /S�- Sunrise Lane 2 $0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= $13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT Hany Brothers , Inc. APPLICANT ADDRESS 170 West Main Street Rockville, CT. 06066 APPLICANT PHONE# 8 6 0-8 7 2-4 7 0 6 OW N SFq OWNER B & M Euterpr i ses OWNER ADDRESS P. 0. Box 1060 South Windsor, CT. 06074 0 ! �.► OWNER PHONE 8 6 0-6 4 4-5 2 8 8 C ESTIMATED COST$ 13,6 0 0.0 0 U �'%W IS THIS A CONTRACT COST? 91 Yes 13 No MPS _, (J FEE ENCLOSED$ 182 .00 OR-CO TYPE OF JOB: dS 3 New Installation 0 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A .I�RESIDENTIAL BUILDING PERMIT APPLICATION?U YES ❑ NO ❑BUSINESS CURRENT USE AND OCCUPANCY New construction ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY single family ❑EDUCATIONAL ❑INSTITUTIONAL ENGINEER'S NAME PHONE ❑FACTORY ❑ STORAGE ADDRESS ❑ GARAGE ❑MIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION all plumbing SIZE OF MAIN DRAIN 4" A B S NO.OF TOILETS 4 STYLE 1 . 6 NO.URINALS STYLE NO.OF BATHTUBS 2 NO.OF SHOWERS 1 NO.OF LAVATORIES 6 NO. OF CONDUCTORS SIZE NO.OF STACKS 2 SIZE 3" & 12 AREA OF ROOF NO. OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES 2 KIND 1 whirlpool; 1 laundry set t u b ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW X❑YES ❑NO SIZE OF WINDOW 2 x 5 IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER SEPTIC TANK SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER 3/4" & 1/2" WATER HEATER: TYPE g a s MANUFACTURER State DESCRIPTION OF WORK All plumbing for 32 bath residence . THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. P1 #00203726 P1 CT CONTRACTORS LICENSE NO. E STATE SIGNATURE OF APPLICANT C DATE 5/3/0 0 � •r DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# Oo 644-2511 ext. 230 7 at Building Inspector Application must be printed or typed . J Loca 'on of Job: FEE SCHEDULE -5_�L 4 f 5 C $0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= $13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT a APPLICANT ADDRESS 7 o l /Z L, 1-;weQ APPLICANT PHONE# OWN S OWNER6 _ —c ,f Q 5 l q� OWNER ADDRESS �, = 0� /e lra f� E� 4 OWNER PHONE C ESTIMATED COST$ 0 3Q .. cxn V IS THIS A CONTRACT COST? WYes 0 No �CJ FEE ENCLOSED$ S O�� TYPE OF JOB: ORS C Installation 13 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: P344EATING 2(RESIDENTIAL ef,p/C ❑COMMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING ❑STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE ---5—°F INSIDE 7 -5--°F DIFFERENCE OF TOTAL HEAT LOSS(BTUH)Y&gF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) hLFe —J�� c cyj " t !T gr--:j -470- GROSS HEATING CAPACITY(INPUT—BTUH) 5 0 cLNET RATING(OUTPUT—BTUH) TYPE OF FUEL ❑OIL—GPM OIL TANK LOCATION:❑INSIDE❑ OUTSIDE CAPACITY ❑ GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING _ DESIGN TEMP.OUTSIDE I�5 OF INSIDE_=F DIFFERENCE Z--Q) OF TOTAL HEAT GAIN(BTUH)!r2 (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) 0 VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK -� THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. :�6,391 51 C CONTRACTORS LICENSE NO. TYPE ST TE SIGNATURE OF APPLICANT DATE 6 ADVANCE HEATING JOB NAME: BIN Enterprises So. Windsor DESIGN CONDITIONS TOTAL BLDG. HEAT LOSS/GAIN PHONE 644-5288 P.O. Box 1060 CT. --- -------------------- - -------------------------- BLDG : Lot 1 2 Heating: 80 deg f.t/d BLDG Heat Loss BTU Estimator: NOTES: 15 Sunrise Lane Gaoling: 20 deg f.t/d BLDG A/C Gain BT Stephen Smith ? Room 1 Room 2 Room 3 Room 4 Room 5 Room 6 Room 7 Room 8 Room 9 Room 10 Room 11 Roos 12 AREA NAME; Mas. bed Nas.clos Mas lav Study Foyer Great dinette Kit Dining Laundry Bed 2 Bed 3 Outside Wall Length; 22.0 16.0 23.0 19.5 19.0 18.5 27.5 16.0 27.0 27.0 39.5 61.0 Outside Wall Height; 12.0 9.0 9.0 9.0 19.0 9.0 11.0 9.0 9.0 9.0 9.0 9.0 Sq/Ft S or W Glass ; 0.0 0.0 21.0 49.0 43.0 0.0 13.0 0.0 49.0 9.0 27.0 40.0 Sq/Ft N or E Glass ; 77.0 0.0 0.0 0.0 0.0 56.0 75.0 0.0 0.0 9.0 0.0 12.0 No of Doors ; 0.0 0.0 0.0 0.0 1.0 0.0 0.0 0.0 0.0 2.0 0.0 0.0 Floor Width ; 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Floor Length ; 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Roof Width ; 16.0 10.0 11.0 14.0 15.5 23.5 21.0 6.0 0.0 12.0 19.0 19.0 Roof Length ; 18.0 6.0 12.0 5.5 18.0 18.5 16.0 16.0 0.0 15.0 22.0 17.5 -------------------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- -------- Area Cubic Feet 3,456 540 1,188 693 5,301 3,913 3,696 864 0 1,620 3,762 2,993 Gross Wall sq/ft 264 144 207 176 361 167 303 144 243 243 356 549 Net Wall sq/ft 187 144 186 127 297 111 215 144 194 183 329 497 Wall Heating BTU 598 461 595 405 950 354 686 461 621 586 1,051 1,590 Wall Cooling BTU 299 230 298 202 475 177 343 230 310 293 526 795 S/W Glass sq/ft 0 0 21 49 43 0 13 0 49 9 27 40 S/W Glass Heating BTU 0 0 924 2,156 1,892 0 572 0 2,156 396 1,188 1,760 S/W Glass Cooling BTU 0 0 231 539 473 0 143 0 539 99 297 440 S/W Glass Solar BTU 0 0 10470 3,430 3,010 0 910 0 3,430 630 1,890 2,800 N/E Glass sq/ft 77 0 0 0 0 56 75 0 0 9 0 12 N/E Glass Heating BTU 3,388 0 0 0 0 21464 3,300 0 0 396 0 528 NIB Glass Cooling BTU 847 0 0 0 0 616 825 0 0 99 0 132 N/E Glass Solar BTU 2,695 0 0 0 0 1,960 2,625 0 0 315 0 420 Doors sq/ft 0 0 0 0 21 0 0 0 0 42 0 0 Door Heating BTU 0 0 0 0 538 0 0 0 0 1,075 0 0 Door Cooling BTU 0 0 0 0 168 0 0 0 0 336 0 0 Floor sq/ft 288 60 132 77 279 435 336 96 0 180 418 333 Floor Heating BTU 0 0 0 0 0 0 0 0 0 0 0 0 Floor Cooling BTU 0 0 0 0 0 0 0 0 0 0 0 0 Roof sq/ft 288 60 132 77 279 435 336 96 0 180 418 333 Roof Heating BTU 553 115 253 148 536 835 645 184 0 346 803 638 Roof Cooling BTU 202 42 92 54 195 304 235 67 0 126 293 233 Lights Cooling BTU 246 51 113 66 238 371 287 82 0 154 357 284 Appliance Cooling BTU 202 42 92 54 195 304 235 67 0 126 293 233 People Cooling BTU 87 18 40 23 85 132 102 29 0 55 127 101 Latent Cooling BTU 78 16 36 21 75 117 91 26 0 49 113 90 Ventilation Heat BTU 636 81 248 379 548 511 728 90 389 392 426 632 Ventilation Cool BTU 652 56 332 614 688 557 811 70 599 319 545 774 Duct Heat Loss BTU 310 39 121 185 268 250 356 44 190 191 208 309 Duct Cool Loss BTU 318 27 162 300 336 272 396 34 293 156 266 378 Area Heating BTU 5,485 696 2,142 3,273 4,732 4,413 6,288 780 3,355 3,392 3,676 5,458 Area Cooling BTU 5,625 483 21866 5,304 5,939 4,811 7,004 606 5,171 2,756 41706 6,679 Area Air Heating CFM 72 9 28 43 62 58 83 10 44 44 48 72 Area Air Cooling CFM 188 16 96 177 198 160 233 20 172 92 157 223 TTL Building. Square feet-> 2,966 Heating Air Changes/Hour -> 1.25 TTL Building. Cubic feet-> 31,018 Cooling Air Changes/Hour -> 3.82 TTL Building Heating CFM -> 648 Heating CFM per SQ/FT -> 0.22 TTL Building Cooling CFM -> 1,973 Cooling CFM per SQ/FT -> 0.67 7-20-1999 4;42PIA FROM C WELTI ASSOC 203 657 2514 P. 1 DR. CLARENCE WELTI, P.E., P.C. GEOTEOMNICAL ENGINEERING 227 V1fiWays Strut • P.O.Box 397 GkM6AbUM CT Oe033 July 20, 1999 (om)633.4623/FAX(8t30)667.2514 Mr. Brian Edwards 13&M Construction Fax 644-7525 Re:Sons beneath Foundations at CoUins Crossing; South Windsor,CT, Dear Brian: Regarding the above the soils at the subject sift fall in Class A and art generally sands with relatively high permeability and a water table below footings, for most of the area at least 10 feet Based on desuiPtions in sections 1813.5.1 and 1813.5.3 in the building code this would exclude any dedicated drainage system. Damp proofing is however normally recommended,as are Footing drains. Very ours. iv'' rlC� Elt cc Weld,PhD,Pe Be # �+ .Dr. Clarence WClt4 P. E.,P.C. v� .••�,� . \ r.