Loading...
HomeMy WebLinkAbout16 Stiles Court PFINAL INSPECTIONS:Building —a 2 APPLICATION FOR BUILDING PERMIT Plumbing —2?—9'-Z --- a Z40` � �- HVAC ? —29 -CYZ 16 STILES COURT F Sprinkler 6 8 , 0 0 0 El ctric 7 -'� -" Estimated Cost $ Zonin Permit Fee $ 680 . 00 Zoningit �777 NO. Occupancy Fee $ 3 . 00 AffidaEng. Dept. COMPLETE RED BOXED AREAS. Total Fee $ 6 8 3 . 0 0 Fire Dept. TYPE OR PRINT ONLY Health Dept. SIGN ON REVERSE SIDE. Approved for Co- (Additional Cost) $ TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersign undersignq hereby applies to do work according to the following specifications: Job Location NDSOR CT Lot No. 51 Side of Street R Zone RDF Applicant CLARK REALTY-INC Tel. # 282-0628 Address 658 ELLINGTON RD SO.WINDSOR CT Zip 06074 Lic.# 50035 STREET CITY STATE Owner J .M.J . CONST. CO . INC Address SAMF Architect DAVE GOSSELYN Address SAME. Size New Area: Ft. Front Overall Ft. Deep Overall Total Area 13 8 6 #Garages 1 Lavatories No. of Families No. of Stories 2 Construction Bathrooms Rooms 1st2nd�3rd Size of Lot 1 2 , 6 2 0 Dist. from Street Line Dist. from Side Street Line Purpose of this Permit CONSTRUCTION OF A SINGLE FAMILY DWELLING ING City Water [ Well ❑ Septic ❑ Sewer Approved by Jam- Date G I 2— BD1A 11/88 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in th plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,sid yard lin and required distanc s from all other zon s and is located in a zone in which this building and its us is allowed. /�J ovkll 4SignedCLARK REAL Y INC , BY : I hereby apply for a Certificate of Occupancy for the work described in thig application f ;MV;L_� SignedCLARK REALTY INC , BY: —DO NOT WRITE BELOW THIS LINE— INSPECTION RECORD �/ Footing Framing / Foundation 1 Q Fire lace/Chimne Insulation '� 2 P Y Plumbing Permit# L Inspections: 6 Z uG- 4-4 `Y2 44 C�kL HVAC Permit# e 6 ! Inspections: Electrical Permit#��a�l Inspections: a' r Sprinkler Permit# Inspections: Location of job AFFIDAVIT Additional Fee . . .- . . . . . . . . . . . . State of Connecticut ss. County of Hartford of�1??S.R L'D`►/� Owner I .. . .�.Y�►. . . . . . . . .. . . . . . . . LAgent for building erected under Contractor Permit No. . . . . .2 0.0 91. . . . . . . . . . . . issued by the Dep't of Building of the Zbwn of South Windsor being duly sworn,make oath and say that the actual cost of the completed work authorized under said permit--.%&" 1.id. not. •eXC eed• the. current accepted BOCA Value of $77, 000. 00 . Signed . . ) Z'`�. Q/1'LQ� -'. . . . Subscribed and sworn to before me this . 9. day of A.D.19 . /. Estimate Cost:$ 7 7, 0 0 f4f . . . . .. Difference: $ -0— � lr Pu lip Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- 92-20001-B 68,000 B01 FOOTING 06/11/92 001 D NOT READY B01 FOOTING 06/12/29 003 A REINSPECTION APPROVED B02 FOUNDATION 06/18/92 003 A FOOTING DRAINS B02 FOUNDATION 06/18/92 003 A FOUNDATION COATING P03 ROUGH 06/24/92 003 A UNDERGROUND B03 FRAMING (ROUGH) 07/08/92 003 A P03 ROUGH 07/08/92 003 A H03 ROUGH 07/08/92 003 A E03 ROUGH 07/08/92 003 D NOT COMPLETED B04 INSULATION 07/09/92 003 A E03 ROUGH 07/09/92 003 A COMPLETED E01 SERVICE 07/14/92 004 A RELEASE ISSUED OK PO4 GAS TEST 07/22/92 004 A B10 FINAL 07/27/92 003 A APPROVED FOR CO/CLOSEOUT 92-9061-P 3,000 92-8469-H 3,000 92-12261-E 3,000 Total Est Value 77,000 CERTIFICATE OF OCCUPANCY CHECK LIST Applicant � Certificate of Occupancy o? 0"P01. Address & TIC T. Bldg. Permit No. lJ � Date Reviewed ' Lot No. Pro j No F/ -� Reviewed By -30" Z Date Submitted 7-7-6-`'�Z Z Approved/ - 7' As required in the zoning Regulations, no Certificate-of-Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1 . Approved building permit plan. 2 . Finish grading per approved building permit plan. 3 . Site work; i .e. trees , shrubs, dumpsters, required parking, 4 . Utility location a. Sanitary sewer b. foundation drain C . electrical & telephone d. water f e. other 5 . Sewer connection charge paid. 6 . Appropriate certification JA 7 . Bonding C 8 . Planning & Zoning Sewer Permit No. !e; 7 7�q Pavement Excavation No. COMMENTS: Date : TO : Town of South Windsor Attention : Engineering Dept . 1540 "Sullivan Ave South Windsor , CT 06074 RE : LOT # c�1 __--REDFIELD DEVELOPMENT , South Windsor- To whom it may concern: I/We are the homebuyer( s ) of the above referenced lot at the Redfield development is South Windsor , CT . I/We herby give permission to Clark Realty Inc . , J .M. J . Construc- tion Co . Inc , ( Builders ) and or the Town of South Windsor to enter onto my property to complete work that needs to be done in order to be in compliance with the approved plot plan for my property . examples of the work to be completed : gradi6g , seeding , tree plant- ing etc . a - Homebuyer Nancy Jacq s Ha s Notary VIA —� —_-- Homebuyer My commission expires 3/95 Jim at y C ~ 07 �• e � 1540 SULLIVAN AVENUE SOUTH WINDSOR. CONN. 06074 ~�SOR•co�'� AREA CODE 203/644-2511 June 9, 1992 JMJ Construction Company, Inc. 658 Ellington Road South Windsor, CT 06074 Attention: Nancy Harris Dear Ms . Harris : Re: Lot #51, Redfield; discussion of house relocation (activity in the 401 buffer) At the June 8, 1992 regular meeting of the Inland Wetlands Agency/Conservation Commission, the Agency discussed your letter dated June 4, 1992 and plot plans for lot #51, Redfield as presented by Peter DeMallie of Design Professionals, Inc. The Agency made a motion to, "approve plan B - twisting of house with an 8' encroachment into buffer, previous conditions apply; fence is to be continuous and unbroken as shown on plans submitted for the original approval of Redfield, and placement of proposed deck of 10 , x 10, maximum in northern corner indention at rear of house" . Additionally, the Agency wants to clarify that the tree clearing in the 40 foot buffer area associated with the wetlands is to be selective clearing, not clear-cutting. (See notation on attached Staff Site Change dated May 8, 1992 regarding location of split rail fence and treeline. ) Also the developer is advised by the Commission to notify the homeowners that they cannot dump leaves, grass clippings, etc. into the wetlands or 40 foot buffer area. Should you have any questions regarding this, please call me at 644- 2511, ext. 229 . Very truly yours, 2�L P /AAct.-A"_ John E. McCahill Zoning/Wetlands Enforcement Officer JEM/pmm Enclosure cc: Town Engineer Planning & Zoning Commission Inland Wetlands Agency/Conservation Commission Design Professionals, Inc. , Attention: Peter DeMallie TOWN OF SOUTH WINDSOR STAFF SITE CHANGE f-7 0,1' FOR SITE & SUBDIVISION GENERAL: CHANGE ORDER CONTACT PERSON FchertAxsemault, P.E. Phone No. 291-q755 Addre s s ppsj,= P-rofe, la. Tnc- 4Al(- rni7pv-nr,,rq -4 cr-r- rm.- t Site Name Fedfield P&Z No. jjtj__ ,j,j, d I Owner- Clark Fealty, Inc. Phone No- 282-0629, Contractor LT1,1T Construction Cc many., Inc. /11`/�A�, //.' /Ar,�ent Date: 5/.9/9,) Signature of owner' /,v Y 11 Signature of Design Engr._�"", Date: 5/9-/9 2. V - / I CHANGE: (Describe location and nature of change. Include three (3) copies of plan/profile of Change. ) Mcdify lccaticn of split rail fencne cand trE�!Lne 4.. locati 'f s . r- L.0 en as c�%;r- ,,-i attached nm&-). r"Lluis will allay for resit er-t use Nrcs-_'ective rur&,aser is a gardener) Of armro.=' nately cr-e-halc of e .I -eir bp_ckyarr, tather t,,mm ro tie whatsoever. Vne 1preV' 2*.ousl'KT armrm,-ed lcca-,_J'Xn cc.=,, Ietelv bisects the var,�. P-11 !-OetlanCs will still ramin cn t;ie cther sie.2- Cf the fence. Reason for Change: (Why is change required) See ahcv-,- e:,.plarztim. APPROVALS: (As Required) Dir. Of Planning il Date: _Town Engineer 7 Date: z Dir. of Public Works Date: Other: C\".0 P A", 'I ( /- Date: got STAFF CO ENTS: g64.(=C_ A 4 :5 W tit I ag"I a 0, GZ�q 14 r7046 Ex#0 W� 6,6 CAW 4 V r -White - Town Engineer Pink - Director .of Planning Yellow - Applicant BUILDING PEPJ1IT CHECK LIST - Applicant Clark Realty, Inc . Building Permit No. Address 658 Ellington Rd. Date Submitted 6/9/92 a R VISED Lot No. 5 6 Stiles Court Reviewed by �1'✓3� Project Redfield Subdivision Date In accordance with the Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include : Approved Denied N/A ✓ 1. Name, address & phone number of owner/ applicant. 2. Name, address & phone number of plan preparer. AAA 3. Zoning information - i.e. zone, open space, fl oodway, etc. I 4. Plot plan at 1" =ow scale. a. Subdivision reference, abutting properties, etc. b. Easements of record. V_ c. Lot description, bearings, distances, building lines, area, etc. .� d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate. e. Building location with dimensions. Elevations of proposed finish floor, garage floor & center line of road at driveway. i49 f. Elevations of gravity drainage systems, 'If/ W;Z vP& �l`b/� sanitary & foundation drain at the i¢S /*,f7vr 1Al+*--'Ps' house and the street. 1� g. Tentative utility location gas, electric, water, etc. h. Title block with name and address of preparer, date appropriate certification, live seal and signature. 5. Sedimentation and erosion control. 6. Special Planning & Zoning, Inland/Wetlands considerations. (Plans on file w/Town Clerk) BUILDING DEPT. PZC IWA/CC � t; +� ,� ',r� a,c� ��� �# r4 �-, ,� � � �� t� � a5 =`�` " INN tb WPCASt I C C�,v OTHERS ��� r. et �: j ;L J ' �v Al,[. �uNDA�Io W Ct.�1J A�ioN 7� F3E •- R. lit rail fences shall be installed behind lots 26-37, 39-44, COMMENTS: and - P 7 art p u nnc ar !ssue- . T Ic V&11-�Cf� r/Z1D�� locaTiT n a note regarding mandntory nstallation of tlip split rail fences on the lots shall by included on the final plans. A not shall also lve included which requires th homeowner to maintain and repair th fences as needed. 9. Marker" hell he installed, by the developer rrior to the issuance of Fp Fate of occupancy, indicating that thwre ar regu a e area nil the Into which ar in the wetlnnri buffer limits. PERMIT �E DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT 2(01 Application is hereby : TOWN OF SOUTH WINDSOR APPROVED DISAPPROVED BUILDING INSPECTION DEPT. 644-2511 Ext . 230 ?--ao — C1.2 Application must be printed or typed , Date Building Inspector 1 . LOCATION OF JOB -70/6 4 FEE SCHEDULE No . Street G 0 - $1 000 - $10.00 Floor Apt . No . + Over $1 , 000 - $10 .00 2 . OWNER per $1 ,000 or ffraction thereof � 3 . ADDRESS t E)- bC� 4 . APPLICANTS L t� 5 . ADDRES S ?� \ If �Z' 6 . ESTIMATED COST $ ':2joC)o 7 . IS THIS A CONTRACT COST Yes No 8 . FEE ENCLOSED $ � vaet 9 . TYP OF BUILDIN RESIDENTIAL COMMERCIAL 10 . TYP OF JOB : Original Installation Alteration/Addition/Repair BD 3A 11/88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11 . LOCATION OF JOB 1-b 5 ) , C- t 5 (� } NO . STREET APT. NO 12 . TYPE OF INSTALLATION 13. SIZE OF MAIN FEEDER pr 14 . NO . OF LIGHT LOOPS _ 15 . NO. OF HEAT LOOPS � 16 . NO . OF POWER LOOPS 17 . NO. OF LIGHT OUTLETS_ 18 . NO . OF HEAT CIRCUITS { 19. NO. OF POWER OUTLETS 20. NO. OF CONVENIENCE OUTLETS 21. NO. OF HEAT CIRCUITS 22 . NO. OF POWER CIRCUITS 23. NO. OF LIGHT CIRCUITS 24. SIZE OF HEAT CIRCUITS_ 25 . NO. OF MOTORS 26 . NO. OF PANELS_ 27 . TOTAL WATTAGE a C`5 Kt�J 28 . NO OF POWER FEEDERS 29 . NO. OF SWITCHES �G 30 . A/C LOAD 31. SIZE OF POWER FEEDERS � 32 . NO. OF FIXTURES 33 . TOTAL HORSEPOWER 34o NAME OF SUBCONTRACTORS AND THEIR TRADES 35 . REMARKS AND FURTHER DETAILS : �6 C;� '*' .1��L LICENSE NO. SIGNATURE OF APPLICANT ATE PHONE NUMBER: x -.--T^r,.�.� ___-•-' -,.�=ew..w+.•�-�-*�-r+f-- ,,... -r .��-.,r,.�..E..R,.�.o�-,+rP.F�,eq'e-�,�a�--r,�g^.-s T•-•--•.._-...>_„ ,.-.�.<-e-. --.-er4 ,,...�.....-v+„^-r,^-.R- i �-, ->-.,.-. ,.� Lot No. Building Permit Temporary Service Permanent Service Pursuant to Permit No. ; 'r This Certifies that the Electrical Work for which the above named Permit was granted has been duly inspected and is hereby approved. Owner` ,' 6 t�, ' t Electrician Street ti ��4 r ' d `�• t Building Inspector PERMIT NO. 90 61 DEPARTMENT DECISION APPLI CAT ION FOR Application is hereby : PLUMBING PERMIT TOWM OF SOUTH WINDSOR APPRO DISAPPROVED BUILDING INSPECTION DEPT. 644-2511 Ext. 230 ate Building Inspector Application must be printed or typed. 1. LOCATION OF JOB: Lot # 51 16 Stiles CT. South Windsor, CT FEE SCHEDULE 2. OWNER: JMJ Construction $ 0 - $19000 - $10.00 3. ADDRESS: 658 Ellingto Road Over $19000 - $10.00 South Windsor, CT 06074 per $1 ,000 or 4. APPLICANT: G & R Valley, Inc. fraction thereof 5. ADDRESS: 350 Chapel Road South Windsor, CT 06074 6. EST. COST: $ 39000.00 7. IS THIS A CONTRACT C,�OS�T? X YES 1,0 FENCLOSED: Vim+ 8. EE $ D 9. TYPE OF BUILDING: _RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: _ORIGINAL ALTERATION INSTALLATION ADDITION REPAID. BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: Lot # 51 16 Stiles CT. South Windsor, CT GENERAL PLUMBING 12. KIND OF INSTALLATION: New 13. SIZE OF MAIN DRAIN 4 11 14. NO. OF TOILETS STYLE 15. NO. OF URINALS STYLE 16. NO. OF BATHTUBS 16A. NO. OF SHOWERS 17. NO. OF LAVATORIES 18. NO. OF SINKS 19. DISPOSAL 19A. DISWASHER 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS SIZE 3" 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30 SEWER R SEPTIC TANK? 31. SIZE OF WATER MAIN lit 31A. SIZES OF WATER PIPING & RISERS 3/4" 32. REMARKS AND FURTHER DETAILS As per plans WATER HEATER 33. TYPE Tankless nnil nff hoiler 34. MANUFACTURER AMTI H _atmaker TANKS SAFETY DEVICES TEMPERATURE 35. CAPACITY 20 gal 39. RELIEF VALVE 150 psi 2101 36. TEST PRESSURE 45 LBS. 40. MANUFACTURER Watts 37. WORKING PRESSURE 15 LBS. 41. PRESSURE RELIEF VALVE 30 lh 38. TYPE Hot Water 42. MANUFACTURER Watts 2 P 201758 E.A. Rodr i Queue �-- LICENSE NO. DAT SIGNATU PPLICANT PHONE NO. -76,q Q FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: 04 (NO. ) TOWN OF SOUTH WINDSOR EST.COST• 3,000. _ BLDG. PERMIT N0. o?,001) 1540 SULLIVAN AVENUE FEE _• balk SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 $ 0 - $19000 - $10.00 $1000 or fraction LOCATION OF BUILDING Lot # 51 16 Stiles CT. South Windsor, CT thereof - $10.00 OMJ Construction 658 E11ington Road South Windsnr, CT 2R2-0628— OWNER ADDRESS TOWN PHONE NO. G & R Valley, Inc. 350 Chapel Road South Windsor, CT 289-6896 HVAC CONTRACTOR ADDRESS TOWN PHONE NO. TYPE OF SYSTEM: HEATING X TYPE OF BUILDING: RESIDENTIAL_ A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC X WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT 1009000 ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS (BTUH) (HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): AMTI Heatmaker See attached heat loss sheet GROSS HEATING CAPACITY (INPUT-BTUH) 1 NET RATING (OUTPUT-BTUH) 84,000 IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN (BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT): TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) (PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: S 306817 E.A. Rodrigue STATE LICENSE - NAME & TYPE # AT IG RE f7 ICANT Q Ak 410-1 0jilfri APPROVED 6ATt BD 4A 11/88 I = B - R CALCULATION SHEET 1503 (Modern Method) Copyright 1977 by The Hydronlcs Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL.A COL.B COL.C COL.D COL.E COL.F COL.G 1 ROOM R O H L W H L W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS, FT. ~ _ V BTUH per t of 3 LENGTH EXPOSED WALLS, FT. Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA LL BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION (Table 9, Line 3 x H) ROOM LIN. FT.OF TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED (Bottom of table used for Line 5) 7 CEILING CONSTRUCTION C (Table 9, L x W) - --- —- D g FLOOR CONSTRUCTIONt (Table 9, L x W r Lin. Ft) E 9 COLD PARTITION CONSTRUCTION F (Table 9, L x H) _ G 10 1 Wa11(With Openings) H 2 Wells(With Openings) D J 3 W ell s(W ith Openings) or E nt.H all I 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE K -- COL.A _ -_ COL.B COL.H _ COL.1 COL_J _ COL. K COL.L TOTAL BTUH TOTAL OF BUILDING RADIATION 1 ROOM ¢ AT SELECTED O H L W H L W H L W H I L W H L W DESIGN TEMP.- 2 ROOM DIMENSIONS, FT DIFFERENCE U - - 3 LENGTH EXPOSED WALLS, FT. Q 41 WINDOW AND OUTSIDE DOOR AREA LL BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION *INCREASE BATHROOM (Table 9, LIne 3 x H) TOTAL 20% 6 TYPE OF GLASS (Bottom of table used for Line 5) 7 -- - — - tFOR CONCRETE FLOOR ON CEILING CONSTRUCTION ( GROUND OR FILL AT Table 9, L x WI GRADE LEVEL,USE LINEAR B FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE (Table 9. L x W or Lin Ft) 9 COLD PARTITION CONSTRUCTION (Table 9, L x H) 10 C 1 Wa11(With Openings) 0 e -- — ----- --- ------ CZ 2 EWallsrth OPenings) GX 3 ith Openings)or Ent. Hall He.J 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE This form is available from The Hydronics Institute,36 Russo Place,Berkeley Heights,N J 07922 FORM 1503 iTm -,-._.�_ �_ ___,__.���_ .....__.._._ __�__� ,� ft:',`4y,' ,�.^, '� _ •ice t l '?�'twg'�►��.,I` .._._ - ' F W WE-•KH COMPANY IBR HEAT' LOSS CALCULATION #122052 04/03/9��,°�;���� JOB NAME sSTYLES JOB LOCATION sSOUTN ,WINDSOR WHOLESALER m FW WEBB CONTRACTOR s G�►R,,,Vi�LLEY PREPARED BY sF PINTO JOB REMARKS s Rp '. WOM ;NAM��� � FACTOR ROOM SIZE BTU LOSS 1. `,.��� �a 1 �FT1 BASeBOARD� 1 �,'7'CHEN 2. 00 8X 9 X 9 3j8@2. 92 DIIVNC3 `' � 0, " A 1 z; 3.0tD 8 X lax 1 i h 4828. 46,.s `� 8. �1M`�, `a �i,[y�,��:.'• 4• @@ t,�,�1 X 3 6 X , 12 < t5B9,3if 9.0� � ;�� ` ' 5. 00 x 1@X i 739.21 _ `�� 1 2 ` 1 H �+� .r • � ��' �.,,• a r � 11►INS' t 6. @@ . 3X ` i b X 14.y 5631,9 tea _' 9. 4 /. •J@ SX �,,16 X 2 1039•-,7 ,. ".{ 'p 1 • 7 • , - _'v BID AMk ,t^�s` 8 0@ #' lC_' 12X 13 5839 68�'' ;' �" 9 7 ,. s �T. :,, �` 9. 00 `j$X> : SX 1287. 7 `,�s F, • 1 I fj,"� 12 x',.r�•:.T�fi r7L, �..� �x..ay�.¢. y �.,yu ' .�.�./ *�, ir' . ��'. • i ', ;w fin' ,, # r"N 40 ,'�'� 'BTU"`CALCULATIONS',.HAVE BEEN -°I NCR EB``2o% 1rp,`ALL FOR�;�����`#IA HEAT IN BATHROOM 7``� n,�j r t; .. ,}., �3. !°'•-., 2= 'F�'m� � ,. ^�. k". ,vr •l,' ;4�cv i�:�`r _ ``I'� c"�i_>'.��*_ ,%� s' ; ,"'- �x.��,b�*+i��•� y'R•�.a:� F�,�J x*, ,,M"`'L � "+``Y .. �..y DI MENS aONA DA q� . • . �, . :n ,. �'s_,T +��.y"� !{xt'!`.•4,*''r .,x, ��_�f.'��`L' �S <N'�fA� M1.�, C eyJf .. �L,`�1 �n i Y a, "� 41� ,;,�,,•'q4.« ,#���' �� a m, ar ^.� yr� 'g,.,^ ,.,� fG=°,.,"�a,1!'��S� ati' �K 4�+°P"i'.�, ,'� y,f,.�'9 , SQ.FT ± �;,r+;, SGt. 7.;, �«�Q `; "�� �* "',�,P}` r `� � C .y� R EQ. Fi`' RM. # NET LA88 X "�;;a;.r:.�: ,: Mf V^« . •� R _ L IV. AREA: ya W _�,. .}'�. « iFL,'s y8� mik k 2 153 5 196 `' �x��,° ( Ji'. �� _ r s� 4 ;; yk.,K.:w, a� 14 •. 284 •*� „ , .t. ,' `�'`� "'���*sue��r�'.; r+ °�.''„""„" : ' " BTU HEAT LOSS DATA � RM. # WALL LOSS GLASS;;: A ON `faTAL BTU 1 945. 00 409. 50 ,,;; M3M-'7 0� 4�*72, ,- �=z,,, 3202. 92 2 1071. 00 1410. 50 ';'fit' '► , :�@."5���"�" .'° 4828. 46 3 182@. @@ 1638. 00 f�. �'t0 � , 5393. 36 4 ti 336. 00 @. � 5 1372. 00 2002. @@ ', @ @iih, �� '� 6 1988. 00 1638. 00 1478, 40 "Tllf .` e, 13�S�fiCs" 7@39. 76 7 1428.00 1638. QIQI 12@ 1. 2 •: ` ` '' y "" : 572. 48 ' :5839. 68 6 @ � . .r 8 336. @@ @. @@ 5@6. 2@ r{,,0 ` l0.: ap 443. 52 1287. 72 " ,.�., TOTALS 9296. 00 8736. 00 4827. 90 12, 33963. 02 I (A I f 14 vi THE AVERAGE BTU PER SO. FT. OF LIVING AREA IS 31. 39 THE AVERAGE BTU PER CU. FT. OF LIVING AREA IS 3. 92 FACTORS USED IN CALCULATION BTU\FT FACTOR # WALL GLASS CEILING FLOOR INFILT. OUTPUT, TEMP 2. 00 0. 10 0. 65 0. 11 0. 09 0. 27 600 70 3. 00 0. 10 0. 6.5 0. 11 0. 09 0. 18 600 70 4. 00 0. 10 0. 65 0. 11 0. 09 0. 18 600 70 5. 00 0. 10 0. 65 0. 11 0. 09 0. 12 600 '70 6. 00 0. 10 0. 65 0. 11 0. 09 0. 18 600 70 7. 00 0. 10 0. 65 Q-1. 11 0. OZ19 0. 18 600 70 8. 00 0. 10 0. 65 0. 11 0. 09 0. 18 600 70 9. 00 0. 10 '0. 65 0. 11 0. 09 0. 12 600 '70 G&R VALLEY, INC. MECHANICAL CONTRACTORS-LIC# 1020 Since 19664 PLUMBING •HVAC•SPRINKLERS Town of South Windsor August 27, 1992 Building Department RE: Redfield Community Boiler Flue Pipe Dear Sir, Please find enclosed the information that you requested regarding the Redfield Community project. Sincerely, G & R Valley, Inc. Timothy Rodrigue Vice President Encl. 350 CHAPEL ROAD SOUTH WINDSOR, CT 06074 (203) 289-6896 • FAX (203) 282-1675 ism ' New England Group Manufacturer's Representative Town of South Windsor Building Department Attn: Building Inspector Dear Sir, This correspondence concerns the venting/combustion air system design alternatives for the Heatmaker boiler. The manufacturer provides a standard vent kit that includes both a four foot and three foot length of the outer five inch 26 gauge metal pipe and the hi-temp three inch diameter plex-vent pipe. It is acceptable to extend this concentric vent/combustion air system to a maximum of fifteen feet (with two ninety degree elbows of each size pipe) . We are prepared to provide any additional information that may be required. If necessary, we will gladly review this matter with you personally at the Red Field Commons location. If you have any further questions, feel free to contact me. Sincerely, Elliott P. Shyer EPS :pak ar «a J L, L i992 -,_LEY INC. 174 Quassett Rd. P.O. Box 209 Pomfret Center, CT 06259 (203) 653-2381 Fax: 203-928-7671