Loading...
HomeMy WebLinkAbout145 South Satellite Road P a TO THE BUILDING INSPECTOR ' v of APPLICATION FOR PLAN EXAMINATION AND TO" OF SOUTH WI1rDSOR, COrD� BUILDING PERMIT IMPORTANT — Applicant to complete all items in sections: 1, 11, III IV, and IX. O ZONING I• AT (LOCATION) 4 4 D I S T R ICZ%rP LOCATION (NO.) (STREET OF BETWEEN AND BUILDING (CROSS STREE (CROSS STREET) ' r LOT SUBDIVISION + LOT BLOCK SIZE N II. TYPE AND COST OF BUILDING — All applicants complete Parts A — D A. TYPE OF IMPROVEMENT D. PROPOSED USE — For"Wrecking" most recent use rn 1 0 New building Residential Nonresidential 2 ❑ Addition(If residential, enter number 12❑ One family 18 ❑ Amusement, recreational of new housing units added, if any, in Part D, 13) 13 ❑ Two or more family — Enter 19❑ Church, other religious number of units— 20 Industrial 3 ❑ Alteration (See 2 above) 14 ❑ Transient hotel, motel, 21 E] Parking garage 4 ❑ Repair, replacement or dormitory — Enter number 5 ❑ Wrecking (If multifamily residential, of units ——————— — -i 22 ❑ Service station, repair garage enter number of units in building in 15 ❑ Garage 23 ❑ Hospital, institutional Part D, 13) 16 ❑ Carport 24❑ Office, bank, professional 6 ❑ Moving (relocation) 17 ❑ Other — SpeciJy 25❑ Public utility 7 X Foundation only 26 ❑ School, library, other educational B. OWNERSHIP 27❑ Stores, mercantile 8 le Private (individual, corporation, 28 ❑ Tanks, towers nonprofit institution, etc.) 29 ❑ Other — Specify 9 ❑ Public (Federal, State, or local government) C. COST (Omit cents) Nonresidential — Describe in detail proposed use of buildings, e.g., food processing plant, machine shop, laundry building at hospital, elementary 10. Cost of improvement•,..•••••.•••••• school, secondary school, college, parochial school, parking garage for, department store, rental office building, office building at industrial plant. To be installed but not included If use of existing building is being changed, enter proposed use. in the above cost a. Electrical...................... b. Plumbing ...................... c. Heating, air conditioning......... d. Other(elevator, etc.)............ 11. TOTAL COST OF IMPROVEMENT III. SELECTED CHARACTERISTICS OF BUILDING — For new buildings and additions, complete Parts E — L; for wrecking, complete only Part J, for all others skip to IV. E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS 30 Masonry (wall bearing) 40 Public or private company 48• Number of stories................ 31 Wood frame 41 Private (septic tank, etc.) 49. Total square feet of floor area, all floors, based on exterior C 32❑ Structural steel dimensions .................... 33❑ Reinforced concrete H. TYPE OF WATER SUPPLY 50. Total land area, sq. ft. ........... 34❑ Other — Specify 42$ej Public or private company 43 ❑ Private(well, cistern) K. NUMBER OF OFF-STREET PARKING SPACES F. PRINCIPAL TYPE OF HEATING FUEL I. TYPE OF MECHANICAL 51. Enclosed ...................... 35❑ Gas Will there be central air 52. Outdoors....................... 36 Oil conditioning? L. R-ESIDENTIAL BUILDINGS ONLY 37 Electricity 44❑ Yes 45� No 53. Number of bedrooms.............. 38 ❑ Coal 39❑ Other— Specify Will there be an elevator? 54. Number of Full.......... 46❑ Yes 47 VI Flo bathr ms Partial....... NOTES and Data — (For department use) � N I f t r X IV. IDENTIFICATION — To be completed by all applicants Name, Mailing addr ss — Numb r, street, city, and State ZIP code Tel. No. 2/ Owner or hl .17. Z ` Lessee 2. a A • Contracto 3. Architect or ELThowner i of this building and the undersigned agree to conform to all applicable laws of this jurisdiction. of applicant Address Application date 00 NOT WRITE BELOW THIS LINE V. PLAN REVIEW RECORD — For office use Plan Review Date Plans Date Plansr Plans Review Required Check Fee Started BY Approved BY Notes BUILDING $ PLUMBING $ MECHANICAL $ ELECTRICAL $ OTHER Is VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS Permit or Approval Check Do te Obtained Number By Permit or Approval Check ObtDained Number By BOILER PLUMBING CURB OR SIDEWALK CUT ROOFING ELEVATOR SEWER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OIL BURNER WRECKING OTHER OTHER VII. VALIDATION Bui Iding 8099 P rmit numb r Bui Iding 6-i5-73 Permit issued 19 Building 96.00 Permit Fee $ Approved by: Y Jr TI L Vill. ZONING PLAN EXAMINERS NOTES DISTRICT USE FRONT YARD SIDE YARD SIDE YARD REAR YARD NOTES IX. SITE OR PLOT PLAN — For Applicant Use ^ a�_ ro� e. , .-�w, w3._.d .... ., ' .. b..,-�.«k.^a .....v -.^hw o d x$.-.,6-x-v.i. .°.,.- -E�rv.3a✓.-..x�..b..a-.�t.,dw °� ' _ {. �i-�r � # ., ,„,.-s'p-433 rF^z--#-, _� i _"��,-+-t � -fir-> <��ts•� p #-�.p 'i s.f&.�'°?s ✓-�y,.� a ?-L-�. a¢ s y x. s� - ��.q.-w -t-�.a F }a- .s_�.„..��-�-;-fi'�y a--,. «a-s-^•i-:--�....y.n-r v.�,�s-x m-n�g-.c.,�a.-m..€�r o-^!ag�-sa t_`f� }t.,q�✓,�w-v �® i v� y_a-,�a-.,�.°.,_'»-�aa.�..a -��..�..a"-P-�°,,.°�< n-s-�- t 4. a��. a i � �.a e y-» o- 4 �.o-A �,t A�k.}„s,e r-p.z �®^ 2�.,-a+. o�..s. a sr a >-s -.r.,�.,�,g,e�r•-a.,p„„ � »-a a d-e-?r. a y_x N $Y a g x ,'. � ., r^fe`� g$$ s `_ a`&i i-✓ �i _ h i�_ �'c i''.-�, t ���.' .; z_' t am6 -t + a _.t _�a7 L� � ,-r �yg�jy .^ 391^';— n z r z�-,a� y �I>�. �-v q°,a.a�m�3,.�.,«r b�e R�tee.�� y� j� A��s.•a b,'�s �� F,,,.L-' Y�'%.,. ,. '. "ry, q'^}`a ..�.s.- m -•wa,r .�"„� �.- <� .« m „ s; t j °; -,r. �..,gw<'v.,x°'m .,„ -., »,,71"� � T<g tg -c h„ §+ 4-'r i n r Y§rta c•r 6'rr --ei } �5, a _��¢,_`%. 3 e ,,{ < a Lg. ,b i-f + i ¢• "1+ ..-p...�..;..,«�-i-+.� a^»-�."« ,a..d.,a.,.4'-}-•--vd`-y �.-y^�,�. �.��-..�.a'<4�- .1"d-'4na.°i�t,..r✓,§ ^.-'$-� '�._r-S -°P`�_,•b o-�-^_��, o-b ,r.�-'p�..�" .� '�-! �.�." "�""y.'f a+-.ad c t +. ? e } i•ed t is 7 1 4e 6ta bra, t a 6 a- q>i } i aace a9a d 4i- � �4- d> a ¢.,�- .d f # } 4 § g-4 r^a L p .- •p '-�`?' _7-S-a -�"a'$ q^ a ,a .1 } 1 `. }}.� t f-F 1,<, iiq+ •� i�i � »1. }rya baa y�-« �� � a ���. 611.11 r 'f-d.- ti TOWN OF SOUTH WINDSOR BUILDING PERMIT Date June 15, 19 73 Fee Paid $.96..00 Est. Value $. . .�5..)3 00 Permit W 8099 on the side of So.Satellite Rd. Street Street No. 'y� Owner C.R.T.D. Associates Applicant Milton Factor CERTIFICATE OF OCCUPANCY ISSUED: Date No. Fee Paid $ CLASSIFICATION Install foundation as shown on print pursuant to Article 1111..7 of the State of Conn. Basic Bldg. Code. BUILDING PERMIT 8099 OFFICE OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. South Windsor, Conn. June 15 19 73 94is 'to to Terftflj, That Milton Factor is hereby granted permission to Install foundation as shown on print pur s uan t to Article 114.7 of the State of Conn. Basic Bldg. Code ,at estimated value of $_15s300 on the side of S o•�S at e l l i t e Rd. _jrJ*6 Street on land owned by •H•'r•D• Associates Said work to be as described in Application No. 8399 and to conform to specifications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH WINDSOR. I June 15., 9 73 g Inspector. Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECT I C UT: "When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costs and damages which it shall sustain, or be compeller: to reason therefor." INSPECTION REPORT Permit#�g / Job 1 Footing 7 ''°" 73 r � 2 Foundation •� 3 3 Framing 4 Wiring -- 5 Plumbing L - Jj- 7 3 6 Heating 7 Lathing 8 C.O. .s Ts' 773 "fv TOT BUELDING INSPECTOR APPLICATION FOR TOWN OF MUM Wuw-sm COS PLAN EXAMINATION AND BUILDING PERMIT IMPORTAN — Applicant to complete all items in sections: 1, 11, lll, IV, and IX. O ZONING I• AT (LOCATION) DISTRIC, LOCATION I (NO.) (STREET) OF BETWEEN AND BUILDING (CROSS STREET) (CROSS STREET)♦ ' LOT ��jj [� SUBDIVISION m LOT BLOCK SIZEiGCGe3 J N II. TYPE AND COST OF BUILDING — All applicants complete Parts A — D -� A. TYPE OF IMPROVEMENT D. PROPOSED USE — For"Wrecking" most recent use rrf M 1 KNew building Residential Nonresidential 2Addition(If residential, enter number 12❑ One family 18 Amusement, recreational of new housing units added, if any, 13 T family — Ent its Past D, 13) ❑ wo or more 19 Church, other religious Enter ❑ number of units— — — — --)P- 20 Industrial 3 ❑ Alteration (See 2 above) 14 ❑ Transient hotel, motel, 21 ❑ Parking garage 4❑ Repair, replacement or dormitory — Enter number 5❑ Wrecking (1/multifamily residential, of units ——————— — -- 22 ❑ Service station, repair garage enter number of units in building in 15 ❑ Garage 23❑ Hospital, institutional Part D, 13) 16 ❑ Carport 24❑ Office, bank, professional 6 ❑ Moving (relocation) 17❑ Other — Specify 25❑ Public utility 7 F_� Foundation only 26❑ School, library, other educational B. OWNERSHIP 27❑ Stores, mercantile 8 5C Private (individual, corporation, 28 ❑ Tanks, towers nonprofit institution, etc.) 29❑ Other — Specify 9 ❑ Public (Federal, State, or local government) C. COST (Omit cents) Nonresidential — Describe in detail proposed use of buildings, e.g., food processing plant, machine shop, laundry building at hospital, elementary 10. Cost of improvement,,,,,,,,,,,,,,,, school, secondary school, college, parochial school, parking garage for, department store, rental office building, office building at industrial plant. To be installed but not included If use of existing building is being changed, enter proposed use. in the above cost a. Electrical...................... b. Plumbing ..................... Q c. Heating, air conditioning......... � d. Other (elevator, etc.)............ 11. TOTAL COST OF IMPROVEMENT $ rcr III. SELECTED CHARACTERISTICS OF BUIL ING — For new buildings and additions, complete Parts E — L; for wrecking, complete only Part J, for all others skip to IV. E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS 30 Masonry (wall bearing) 40 Public or private company 48• Number of stories................ ?9 31 Wood frame 41 Private (septic tank, etc.) 49. Total square feet of floor area, all floors, based on exterior 32❑ Structural steel dimensions .................... ®4? 33 F—] Reinforced concrete H. TYPE OF WATER SUPPLY 34❑ Other — Specify 42 FV Public or private company 50 Total land area, sq. ft. ........... 43 ❑ Private(well, cistern) K. NUMBER OF OFF-STREET PARKING SPACES F. PRINCIPAL TYPE OF HEATING FUEL I. TYPE OF MECHANICAL 51. Enclosed ....................... 35❑ Gas Will there be central air 52. Outdoors....................... 36 So Oil conditioning? L. RESIDENTIAL BUILDINGS ONLY 37❑ Electricity 44❑ Yes 45 W] No 53. Number of bedro ms.............. 38 ❑ Coal 39 Other— Specify Will there be an levotor? 54. Number of Full.......... 46❑ Yes 47 W No bathrooms Partial....... NOTES and Data — (For department use) IV. IDENTIFICATION — To be completed by all applicants NarVe Mailing address — Number, street, city, and State ZIP code Tel. No. Owner orC ,•—A 2 45 4- • Lessee F—? 2. -1 7zc I—Aggj!v.>f1v c&—Ae- or ogler,-& Contractor GG 3. Architect or Engineer The owner of this building and the undersigned agree to conform to all applicable laws of this jurisdiction. Signature of app icant Addres XZ Application date 07— lF �.. .. 00 NOT WRITE BELOW THIS LINE V. PLAN REVIEW RECORD — For office use Plans Review Required Check Plan Review Date Plans By Date Plans By Notes Fee Started Approved BUILDING 2 • �� 7--- PLUMBING MECHANICAL ELECTRICAL OTHER VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS Permit or Approva I Check Date Number By Permit or Approval I Check Date Number By Obtained Obtained BOILER PLUMBING CURB OR SIDEWALK CUT ROOFING ELEVATOR SEWER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OIL BURNER WRECKING OTHER OTHER VII. VALIDATION Building 8138 Permit number Building i8�,73 Permit issued ?- 19 Bui Iding Permit Fee s 696.00 plus $3.00 for C .0 . Approved by: l f TITLE VIII. ZONING PLAN EXAMINERS NOTES DISTRICT USE FRONT YARD SIDE YARD SIDE YARD REAR YARD NOTES IX. SITE OR PLOT PLAN — For Applicant Use �k- �s.;s�taa ��— 4-v"rw--r.a..„t-,...�-fit+ e.�-,,.r 3.�+ ^.,o a.q�� - �,.�.r-_ m�s.w-r-f .a-'<-����6 -�".r-�a•a=. ��.�...�+� �P Y Y q�t �}'r�-�-we-a�t-`�'-.t'.�' ..a��,wpgi �k.g„b.a-.b^x.,....;,^ ..��.a.��.,�,..m6,-,�..o c -a#�.i�„-�e�-�a..�,a_» m.�. ab yyw+r a g«�,qq � 99 g t+M`ai' a, ail iq ii{ a ,-r. ti §vs.mT -� -4 d aT"d 's-{b t9 t�,1�} � �¢a� -¢ Y �•�-�# <YS �n�,:.q g•e �`d-.�� �a zf Y P�-'4,-aa � t b 4-�.,,y_3 0 -�,. t�. p.�p.q•t-'. w -i �-� d� V` �µ d� E'� T. ,.b.B T-r-i.L a. W"f"" j. .Y° -,�., .sad.,$ pp t¢¢ e � .�. q.b�. _� ��_'�. �� , �..�� p> rap a F �- ni ..{ xt t }t4-� -t- a@at . j�°� s <¢: s�<�ro y; .1: ' f4+t t + S•}"_}p 4 :ta} i1t tt ,Q , }: }v { j: M.' �; � _ r ? * � ¢ i + ��4� t $q f47 TOWN OF SOUTH WINDSOR BUILDING PERMIT Date July 18, , 19 73 Fee Paid $.696..00 Est. Value $116.,.000 Permit N d 8138 on the side of So.Satellite Rd. Street Street No. 145 OwnerC.R.T.D. Assoc. Lessee Applicant Milton Factor CERTIFICATE OF OCCUPANCY ISSUED: Date No.4375 Fee Paid $$ 3.00 CLASSIFICATION Industrial Building BUILDING PERMIT 8138 OFFICE OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. South Windsor, Conn. 'TAT 170 1P 94to to to Terttfi , That Kilton Pastor is hereby granted permission to Indmatri al Building Building wait #80" WPIttOn for fo=datlon for this•buildiag. Total coat $131 300 00 116 000 • at estimated value of a$ on the side of 34. gig'Satelli to Rd. Street on land owned by C'R'T.D. Assoc' Lasass Said work to be as described in Application No. 8438 and to conform to specifications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH WINDSOR. Issue42< JU17 17 103 Bu'ding nspector. Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: "When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costs and damages which it shall sustain, or be compelled' to reason therefor." Permit 1-4o. /C�14" TOWN OF SOUTH WINDSOR SOUTH WINDSOR, CONN. Permit N0 4375 Certificate of Occupancy THIS IS TO CERTIFY th at No. in the Town of South WIndsor, Connecticut, has been erected and completed in accordance with the Building Code and Zoning R gulations of the Town of South Windsor, and is hereby approved for occupant HuffildiAg Inspector %mer, Builder op Fee Pai "� Date 'r 19 5329 ELECTRICAL APPLICATION Application No.,5640 on the side of So.Satellite Rd. Stmt Strect No. 145 Owner Milton Factor for C .R .T.D. Electrician -Milton Levine FILED IN OFFICE OF The Building Inspector 9-4-73 19 INSPECTION. Am No Electrical Work shall be started until a Per- mit is granted by the Building Inspector. In New Buildings no wiring shall be started until the plumbing and heating pipes, and the fire stops (if of wood) are installed, without a special permit from the office of the Building Inspector. APPLICATION FOR PERMIT TO DO ELECTRICAI. WORK. �f 3� 6 0 '� No. .......�r.......�"........................ 5129 PermitNo. ........................................... TO THE BUILDING INSPECTOR of the TOWN OF SOUTH WINDSOR, CONN. ......I..... hereby make application tct perform Electr cal Work according to detailed description below. All provisions of the Rules for Electrical Installation, Section 48, Building By-Laws, shall be complied with whether specified herein or not. /l ' �t/i-/� t South Windsor, Conn., .........L.. ...........7... ............... ............. 19/. Sign here �........... Address ( � / 0 Z'JV 7-h�J\ 1 /' 1-'M)':fo yp c t� /) ....................,...Q...... ................................................................... .........................A.LF..... Location !.....1.. ........J....0........1!t ��.�Tr.......f.�,Ll........ Side of ........... '`.. .. � C 7WC )C Natureof Building .................................... .................................................. How many stories ................................................................................................ Newor old Building ............................... ............................... ............... ..... How many families ................._............................................................................. Kindof Installation ...................................................................................... ..... How many Stores ................................................................._.................................. Owner Milton Factor for C. R.T.D. 145 So.Satellite»�Rd .»_......Address ».... Architect ..................................................................... .. ......................................... Address ............................................................................_................»...._............ ..._.... Builder ......................................................... .......... ....... ................... ....................... Address ......................................................... ..»........................................»... .......... Electrician N.. ..L.. . �.=-:........... E...V.. tqn. p�..`........................ Address .... ....10.....f.............��.�p 6.k.1 Av... .......».»..»L�. L��� /0 l�-a` Sr Size of Main Wires .. No. of Light Loops-----7--'........... ............ ... ....... No. of Heat Loops ........... . .. .. No. of Power Loops ......_.................».»...._.... No. of Light Outlets . No. of Heat Outlets .... No. of Power Outlets .... ............. ............. .................. .. .. ..... . ..................................... Nod of Light Circuits ........... No. of Heat Circuits ................ . . ........ No. of Power Circuits .. ............................. No. of Sockets .................. ........ .. ............. .d-To. of Heat Receptacles ........ .... ...... . No. of Motors ........................................................ No. of Panels .............. .. Size of Heat Circuit ...... ...... ... .... ...... No. of Power Receptacles ................. ....................................... ...... No. of Switches .........1.....�...... .. ............ Total Wattage ..................................................... Size of Power Circuit ................ ...... ....... Total Horsepower ..................................... . No. of Straight Electric Fixtures ... .... . .... . ....................... No. of Combination Fixtures ............. ............................ .... ............ No. of Receptacles ..........3....0.......... .................................... . . ............ No. of Cord Drops ............................................................................................. Remarks: For other kind of Installation ... ............................................................................ ............................................................................... ���. �� 1. .. .... ..................................................................................................................... ....... .......... . .......�'..��YY�1..../.. .................. ........................................................................................................... .............................. ................_........................................................................................................................................................... .................................................................................................. .............................................................................................................................................................................. ..................................... Estimated Cost ......CD.... ............................ ...... 4388 PLUMBING APPLICATION Applinrion Na. 4177 on the _.. _rA-- — Side of 5...o......_ Street NO. ._.. i45 ' ,�a o r Owner ......... �U Filed in Office of The Bing Lrpocooc 8-7-73 19 n�sr�caair. No permn shall camtzu:r, add to or alter my portion of the drainage symem of any bwl&g (except to repair leaks) umiil a Pram'- is gcaoted by the Building LWemw. 4177 Y388 ApplicationNo. ..... .................................. Permit No. ..... ............................ TO THE BUILDING INSPECTOR of the TOWN OF SOUTH WINDSOR. CONN. ........ .... hereby make application to perform plumbing according to detailed description below. All provisions of the Rules for Sanitation, By-Laws, Sections 33 to 47 inclusive, shall be complied with whether specified herein or not. South Windsor, 19 Sig.here ......4....2...................... ....../...... .4Z......2.... ..... ....... ... ................................ Address ...... ....... ............... .......... �'tr'-Ot Location -.56............. ....... side of ..................................................................................................... Street Natureof j3ulldin ... . ............................. ................... How many stories .. ....................................................................................... Owner ................. ........... ............. ....... ................. ....... Address....... .....................................................................I....................................... Architect ... ........................................ Address ....... ...................... .. ................. ..... ............... ................ A0...... ...... .... Builder . . . . ........ . ... ... ............ ... . ........ Address . ................ .... ............. ..... (.tip.......... ........... Plumber . ..... ......................... ................ ................................................ . Address .... .... ....... DRAINAGE CESSPOOLS, How many . ......... ............................... ................. Where located ................................................................................................... Are they water tight . .......................................................................... Of what materials are they built .................... ............................. Size of pipe from house to cesspool ................... ........ .. ..-Km* d of pipe . ............. . ...... MAIN DRAIN IN CELLAR, Material&.. a eter ...............V.......................................................................................... Aboveor below cellar bottom ... ..... .......................................)... .. . . ..................................t.................................................................................... SOIL PIPES, Material . ..e*'�.. ....... .... ... ............ ......... Diameter ....... �/. ....... ..................................................... ............................................ WASTE PIPES, Material . ...... .. . .... .. .......... Diameter ........ TRAPS,Type proposed to use is .. .. . ................................................................................................................................... ................................................................................................. RAIN WATER LEADERS, where do they run to !�'Ce CV REFRIGERATORWASTES, where do they run to ... ... . ............................................................................................... ............................... TANKOVERFLOWS, where do they run to . .. . . .... ..............................................................I............................................... FIXTURES WATER CLOSETS, How many ......... ....5 5 ........ ... Where located �a�'.J)Ke.............. ......az'4�L Distance from trap to vertical soil pipe ....... ............. Pattern V ... .................................................. ............ WASH TRAYS, How many ... ....... ................................... .. Where located .... ..--*......... SINKS, How many .. -- '-/... ............................................................... Where located . .. ....................................................... BUTLER'S SINKS, How many ....................................................... Where located, .................................. .... .......... ......... REFRIGERATOR SINKS, How any ., Where located ....... ....................... ........................ .......a12-6-j LAVATORIES, How many ..........�i... ....... ...................................... Where located ... .......................................................................................... .........**.*."***........ .. ............... BATHTUBS,How many....................................................................... Where located ..................................................................................................... URINALS, How many .......... ............................................. here located ... ... . ............................................................ Are water closets and urinals to be local ented If not, is there a window in outer wall of room where same are to be loii::.at!t ....... ...............................................................................................................................Estimated Cost PERMIT # Application For 4116 W DEPARTMENT DECISION 4-338 Heating Permit 3 O APPLICATION IS HEREBY: DEPARTMENT OF LICENSES AND INSPECTIONS N O APPROVED ❑ DISAPPROVED TOWN OF SOUTH WINDSOR I 0 co 8-14—73 0 00 4) DATE CHIEF INSP 07APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BEL M O .� 1. LOCATION OF JOB O _ $4 c 145 So. Satellite Road NO. STREET +, O � v LOT NO. FLOOR APT. NO. � O N 2. OWNERCentral Records & Tape Dist. ° S. ADDRESS 145 So, Satellite Road �O 3 Sn_ Windsor, Conn. 4.PHONE S. APPLICANT Sffiith Automatic Sprinkler,__ Inc. o s. ADDRESS 6 50 New Ludlow Road 'p 1-413- °2 r' So. Hadley, Mass. .7.PHONE532-9467 w B. LICENSE NO. 10-1-74 O w B. EXPIRATION DATE OF LICENSE v a 10. ESTIMATED COST s 106000, - 11. 18 THIS A CONTRACT COST? ® YES ❑ r" bo � No e 1:. FEE ENCLOSED = permit #b136 k O 12. TYPE OF BUILDING F0 ❑ RESIDENTIAL ® COMMERCIAL +' 14. TYPE OF JOB: INDUSTRIAL cc 3 RIGINAL ALTERATION INSTALLATNIN ❑ ADDITION REPAIR APPLICATION FOR HEATING PERMIT (Continued it m R v rse Sid 11. LOCATION OF JOB 145 So. Satellite Road NO. STREET FLOOR AFT.NO. 12. TYPE OF INSTALLATION: ❑ OIL BURNER ❑ ELECTRIC ❑ VENTILATION 12 SPRINKLER ❑ GAS BURNER ❑ STACK ❑ INCINERATOR ❑ MISCELLANEOUS IDENTIFY SIZE LOCATION SIZE SIZE 13. OF TANK OF TANK OF FILL OF VENT 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NO. B.T.U. OR SO. FT. NET B.T.U. OR SQ. FT. GROSS FIRING RATE FLOORS TO BE HEATED NEW OR OLD BUILDING INSULATED — YES OR NO TYPE OF WALL INSULATION ROOF OR CEILING INSULATION AVG. SYSTEM WATER TEMP. B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE °FAHRENHEIT MAKE OF RADIATION: BASEBOARD. COPPER CONVECTORS. OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SO. FT. OR B.T.U. 15. TO BEDESCRI TUNE OF WORK Same as shown on plans to sprinkler Central Record and T2DP Distributors 16. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS): Roots slzE WINoows AREA - SQUARE FEET e.T.u. s.T.u. o DISTRIBUTION INSTALLED AND DOORS VOLUME TOTAL TOTAL ILI R OM NO. GROSS GLASS NET WALL CEILING FLOOR CU. AT 70•F CORRECTED J j REGISTER L W N AND TEMP. TO <F F TYPE AND SIZE RAD. OR LEADER SIZE < WALL F'Lto ft (INFILT.) DIFF. •F O m m SQ. FT. FREE AREA TOTALS A. HEAT LOSS FROM BUILDING B.T.U./HR. B. DOMESTIC HOT WATER DEMAND B.T.U./HR. C. PIPING. OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY: NAME ADDRESS 1s. THEIROTRADES RS AND SMITH AUTOMATIC SPRINKLER, INC . ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE(OWNER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. /J 'PLICATION TO BE COMPLETELY FILLED IN. 8-2-73 �,ch�(�l1 DATE SIGNATURE 00 A►►LICANT 356070 PERMIT # Application For 4110 DEPARTMENT DECISION 2 Hea Permit 0 433 tmg 3 APPLICATION IS HEREBY: DEPARTMENT OF LICENSES AND INSPECTIONS N 4� APPROVED � DISAPPROVED TOWN OF SOUTH WINDSOR o cd 8-7-73 ' 00 DATE CHIEF INSPE APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOW O C 1. LOCATION OF JOB o � S6 0 �<T` STREET � o � ej cd ! rA LOT NO. FLOOR APT. N O 2. OWNER 164 O S. ADDRESS ' 3 f 4.PHO C! s. APPLICANT r o Sao a. J b r AD ESS T.PHONE ,. 2 1 wd •. LICENSE �0- S-6 a /(j ZI 71 G w II- EXPIRATION DATE OF LICENSE 10. ESTIMATED COST s a� Od *" 11. W THIS A CONTRACT COST? ❑ NO be .R .5 Permit {#8138 "� 12. FEE ENCLOSED s a� 13. TYPE OF SUILDINQ b0 ❑ RESIDENTIAL Of COMMERCIAL �c 14. TYPE F JOB: INDUSTRIAL x ❑ RKINAL a ALTERATION INSTALLATION ADDITI N REPAIR APPLICATION FOR HEATING PERMIT (Continued tr m Reverse Side) f- " 11. LOCATION OF JOB 516 . NO. STREET FL OR AFT.NO. 12. TYPE OF INSTALLATION: I� OIL BURNER ❑ ELECTRIC ❑ VENTILATION ❑ SPRINKLER ❑ GAS BURNER ❑ STACK ❑ INCINERATOR ❑ MISCELLANEOUS IDENTIFY SIZE 5 6 a LOCATION ®/ SIZE �t SIZE 13. OF TANK OF TANK _ L 'F( OF FILL OF VENT 14. B.T.U. EQUIP. AT REGISTER ^FURNACE MAKE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NO B.T.U. OR SQ. FT. �N�__B.T.U. OR SQ. FT. GROSS FIRING RATE FLOORS TO BEP16 ED NEW OR OLD BUILDING �1 INSULATED — YES OR NO ,�J TYPE OF WALL INSULATION ROOF OR CEILING INSULATION AVG. SYSTEM WATER TEMP. B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE °FAHRENHEIT MAKE OF RADIATION: BASEBOARD. COPPER CONVECTORS. OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SO. FT. OR B.T.U. DESCRIPTION OF WORK CX�tSG 15. TO BE DONE: 16. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS): R OM SIZE WINDOWS AREA SQUARE FEET B.T.U. e.T.U. F D A -NO Dooas voLUME <F DISTRIBUTION INSTALLED TOTAL TOTAL LL ROOM NO. GROSS GLASS NET WALL CEILING FLOOR CU.FT. AT 70•F CORRECTED j t RAD. REGISTER L W N AND ` TEMP. TO 8�6 TYPE AND SIZE OR LEADER SIZE WALL F'oto (INFILT.) DIFF. •F F Ii a SQ. FT. FREE AREA TOTALS A. HEAT LOSS FROM BUILDING B.T.U./HR. B. DOMESTIC HOT WATER DEMAND B.T.U./HR. C. PIPING, OTHER THAN NORMAL B.T.U./HR. ' ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY; NAME ADDRESS SUBCONTRACTORS AND 18. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE ( ER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. APPLICATION TO BE COMPLETELY FILLED IN. '5� 4e661��_ ATE SIGNATURE OF APPLICANT TO THE BUILDING INSPECTOR of dw APPLICATION FOR PLAN EXAMINATION AND TOWN OF SOUTH WINDSOR, CONK BUILDING PERMIT IMPORTANT — Applicant to complete all items in sections: 1, 11, III, IV, and IX. o ZONING I• AT (LOCATION) DISTRI�__E LOCATION (NO.) (STREET) OF BETWEEN AND BUI LDING (CROSS STREET) (CROSS STREET) LOT SUBDIVISION LOT BLOCK SIZE V1 II. TYPE AND COST OF BUILDING — A11 applicants complete Parts A — D A. TYPE OF IMPROVEMENT D. PROPOSED USE — For"Wrecking" most recent use M M 1 ❑ New building Residential Nonresidential 2 ❑ Addition(If residential, enter number 12❑ One family 18 ❑ Amusement, recreational of new housing units added, if any, 13 ❑ Two or more family — Enter 19 Church, other religious in Part D, 13) number of units— — — — --)P. 20� Industrial 3 � Alteration (See 2 above) 14 Transient hotel, motel, ❑ 21 Parking garage 4 Repair, replacement or dormitory — Enter number 5 ❑ Wrecking (If multifamily residential, of units ——————— — -i 22 ❑ Service station, repair garage enter number of units in building in 15 Garage 23 Hospital, institutional Part D, 13) 16 ❑ Carport 24 Office, bank, professional 6 Moving (relocation) 17❑ Other — Specify 25 ❑ Public utility 7 ❑ Foundation only 26 School, library, other educational B. OWNERSHIP 27 Stores, mercantile 8 ❑ Private (individual, corporation, 28 ❑ Tanks, towers ' nonprofit institution, etc.) 29 ® Other — Specify 6Ole 9 ❑ Public (Federal, State, or y���R. & E� local government) C. COST (Omit cents) Nonresidential — Describe in detail proposed use of buildings, e.g., food f-e processing plant, machine shop, laundry building at hospital, elementary 10. Cost of improvement,,,,,,,,,,,,,,,, O� " school, secondary school, college, parochial school, parking garage for, department store, rental office building, office building at industrial plant. To be installed but not included If use of existing building is being changed, enter proposed use. in the above cost r a. Electrical...................... , _/ . N "z b. Plumbing ...................... J c.Heating, air conditioning......... s� C d. Other (elevator, etc.)............ 11. TOTAL COST OF IMPROVEMENT $ Oo III. SELECTED CHARACTERISTICS OF BUILDING — For new buildings and additions, complete Parts E — L; for wrecking, complete only Part J, for all others skip to IV. E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS 30❑Masonry (wall bearing) 40 ❑ Public or private company 48• Number of stories................ 31 Wood frame 41 ElPrivate (septic tank, etc.) 49• Total square feet of floor area, all floors, based on exterior 32 Structural steel dimensions ..................... 33❑ Reinforced concrete H. TYPE OF WATER SUPPLY 50. Total land area, sq. ft. ........... 34❑ Other — Specify 42 ❑ Public or private company 43 ❑ Private(well, cistern) K. NUMBER OF OFF-STREET PARKING SPACES 51. Enclosed ...................... F. PRINCIPAL TYPE OF HEATING FUEL 1. TYPE OF MECHANICAL 35❑ Gas Will there be central air 52. Outdoors....................... 36 ❑ Oil conditioning? L. RESIDENTIAL BUILDINGS ONLY 37❑ Electricity 44❑ Yes 45❑ No 53. Number of bedrooms.............. 38 ❑ Coal 39❑ Other— Specify Will there be an elevator? 54. Number of Full.......... 46❑ Yes 47❑ No bathrooms Partial....... NOTES and Data — (For department use) IV. IDENTIFICATION — To be completed by all applicants Name Mailing addres Number,,,&;reeA city, and State ZIP code Tel. No. Owner or Lessee 2. Contractor 3. Architect or Engineer The owner of this building and the undersigned agree to conform to all applicable laws of this jurisdiction. Signatur of applicant Address Application date 3 / I de .. 00 NOT WRITE BELOW THIS LINE V. PLAN REVIEW RECORD — For office use Plans Review Re wired Check Plan Review Date Plans B Date Plans B Notes q Fee Started y Approved y BUILDING PLUMBING MECHANICAL ELECTRICAL OTHER VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS Date Permit or Approval Check Obtained Number By Permit or Approval Check Obtained Date Number By BOILER PLUMBING CURB OR SIDEWALK CUT ROOFING ELEVATOR SEWER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OIL BURNER WRECKING OTHER OTHER VII. VALIDATION Building 8319 Permit number Bui Iding Permit issu d Jan 3 19 ?4 Building 12.00 P rmit F Approved by: i 4)0 / TITLE VIII. ZONING PLAN EXAMINERS NOTES DISTRICT USE FRONT YARD SIDE YARD SIDE YARD REAR YARD NOTES IX. SITE OR PLOT PLAN — For Applicant Use , r e iy z `° Lr f, i a.,b �b z x .. ,� " �. 1 z-&F � { -,-�,�i q t� - }-a �d_t, , " d n ♦k-....$ b � .* { r y �_ F�i<y,,.8 Y v. a f a�➢,..,.,.. s•�s_7 ¢x ss '� C� ,.-. a , , e �., - d � $ ,. ,r. „i..�{:n .:�..�,..t� �¢, N -`� , , �� o�-�� Y� ofq g-»7 a$ u m l°e � $$< e ? �, P�,� o e - .- ' ,_ E L 3{s 'A--�"q„-w-•__ •'g -" , .,, � a ?�q^° 5 d_ c D .qre�$�.� e �. �3•,t p-i , _x� a by q � .,yf r �4 D = -, 7 � r a r 4$-t -. f x [ 49 Ek`., m .,,A e .i {• _,._ Lµ rs ! a .. . t a r e 1 -k� ,. , > ., � � �°n g` .�n R.g, �„ _{ b z �.-d 2 �, q ✓�. c ti i �i' m+-�y - {[ y $ a y >.. � r_ «4C x5b,Ka ¢_ j� � ram$,¢-e _♦a - i .Y � r a ,, + }x �-8 `� 'r , �. } n .__a }� t��x e-0x _' � , F r , _ � a ,. � <. s ; 9. >„ , ) V � a .-.A w,. _I� �• - �- �� ♦- #3 4 o<Y-o �� ' � . yt.» j$ " f E 3 ' e$ •,Lf � � i `_ � � _� � .�� _,� vg ��.-p a._.� e� ¢Y.g.,,�, t �,� �`T r ez .. �� � n �.. � �y�,' � �� E , � �� ��•` _ _ °y ,. � e e e e ., e "' § o - �' &-f �< 5 5 .,.>✓,_ ?,4=9-< ? ,, w,,a r�r-z v ,A,w�# s�,b s 4,.�w.u[e x,,ro<L. I _$ - + +{ ��k-azg er r�qqi ��-�gd-do-.��-d m•�•1,'1�-0'°Wfm w�,:-a� ice« , _ -.�fi4 t'§P-}LI. b- •.p. -.br} _F�-#-'tr-r-:.-m- gt -+ �+"`--r-,r:^-s--'--t`. - ', '3"-.°t' -i�s -f,w_ .t-L-_w-+ ,.m...4.g-w„t�,t-.•.. ,_..,.�.-q„S�w.-,-,-R -s„ $r d d-?+.'�`'; r m t, :a s e_s -•y t ;a- #,F,-, cI! p g-+.. e- �- " « $$ $ -}}-�� -§ tb},» 1 } i��4 Q_' ��,��r'a ej �.at �. ��l� ,y.._e.r .a.§i �.; .,K�[ .}. i., .}v- r jb b r }s...e w .§. �... { .• F p.�." .: t�` +`.y'§ g r A -,,,s -�.� p wcy <.+,4{-A-; tt+- .g a%a--? i f�-�d-'-4 j c P t '-t r g; b a.. t 4 :8.1 x a ,..x�., 4»§ ab gnraatj" s,tusff ka€<e bf ; 1 a-# # p m- aad� #� fb' f i " Yq rmt" �,��,_. «}. t-+, tt .}.... n� q� �t •� �a, yd � "� +w°-��ft. "°*s 7re s# Via` ',at «aryry tt - t€t q o- `i} _f> "§ v ei t� �� $ � �+ §f d 2-r} -+L+3 �f m r s� f# �.+-t t�_,� +t 1-� 3_.�d �.�. -�'� �"Y�' +,-a— }} i i d 1 3 ff 1 il`t big ! r# t+t a�� y ,• t i*ga addkq <* 9f f•o,- ", s ? >d t b m Po e b i <.,$ ! a a h•b P�'°"�-+'.y P` { {'b 4 -s -i i F j k p i d-g y iy. t + h �.i -$- l$- '� ®e ,�,�.�_ #- pfy ep} ..tr p T •r4 4-k tt` r3 -� .- S% -6' s ,-'dY _ b YF a..� s 4 -t� 3,a ♦ a �i { •;-{ A d O},tat r �+s. i'>-� r� �$ 3 #f f $'i • t t 'm + s �`z a d #+ '-a } {} � t t-'4• }� # i b ,. a .q+ ;.- E-��r _.._ o}-b a e i-` a-t-L �' � tt c 4if - ix 41- }-�6t e§ Ee` �g # a € ,. •4Y 4 ¢ i i 1 tt e� 'i rg} 1 # ab qe vq: *b $Y'id TOWN OF SOUTH WINDSOR BUILDING PERMIT Date Jan. 3 , 19 74 Fee Paid $.12.00 Est. Value $.1 p 2 00.00 Permit lr? 8319 on the side of South Satellite Rd. Street Street No. 145 Owner National Telephone On. Applicant George Wi ti lr CERTIFICATE OF OCCUPANCY ISSUED: Date No. Fee Paid $ CLASSIFICATION Construction of tool crib and manager' s office within the :ibuildirw BUILDING PERMIT N? 8319 OFFICE OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. South Windsor, Conn. Jan. 3— 1974 94is to to Terttf1 j, That leorge Wi tik is hereby granted permission to Construct tool crib and manager' s office within the building, at estimated value of $ 00 on the side of 145 ou th Satellite R d. Street on land owned by `dational TeleT)hone Company Said !',o rk to be as described in Application No. 8619 and to conform to specifications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH WINDSOR. I Jan. 3 9 74. Z91 /vBui ' g Inspector. Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: "When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costs and damages which it shall sustain, or be compeller: to reason therefor." r • r INSPECTION REPORV Permit # f" Job t 1 Footing Ad- 2 Foundation 3 Framing 4 Wiring �- 9 5 Plumbing 6 Heating 7 Lathing 8 C.O. --2 % 4502 %n, PLUMBING APPLICATION App>i<at. No. 4291 on the . A&of .80. Satellite Road Slslp- Street No. ........_.145 Owner ___ ,Milton Factor Plumber .� Donald D'Adde o Filed in Office of The Building Itrpocmc Jan 7 19—ZLL 0�. No person 9611 crosau:t, add to or alp say portion of the drainage system of aa9 bml&g (except to repair leans) until a Penn it is granted by the Building Lupector. Application No. ...................... Permit N . ...........45.QR.......... TO THE BUILDING INSPECTOR of the TOWN OF SOUTH WINDSOR, CONN. ....... ........... ......hereby make application to perform plumbing according to detailed description below. All provisions of the Rules for Sanitation, By-Laws, Sections 33 to 47 inclusive, shall be complied with whether specified herein or no South Windsor, ... ........!..........� ........................... 19 -Z' Sign here ...................... ...... ........ ... .... .... ...... ..... Address.........;;2. . ..... .... ....... .......... .......... ........................................ Location ..... ..................................................... w.. ....... .......... side of ...................................................................................................... Street Nature of Build, . ........................ How many stones .. ................ Z7................. A*_1^ ' 'A*'*i** * " . . ......... Owner ......... .. ... . .... .... ........ ............................ . ..... Address ....... Architect .................................... ................ ........................................................ Address ....................................................................................................................... Builder . ....................................... Address .........5;Z". ... ............ . .. ............. ................................ 6 ........ ............................' M� ......................................... ...................................................... Plumber ............................................... ............. Address .... ..................... DRAINAGE CESSPOOLS, How many ........ .. ............................ .................... Where located ..................................................................................................... Are they water tight -.. - - ....................................................................... Of what materials are they built ................................................... Sizeof pipe from house to cesspool ....................... . ........ Kind of pipe ................ ..................................................................................... MAINDRAIN IN CELLAR, Material ................ .... . Diameter ................................................................................................................. Aboveor below cellar bottom . ........................................ ... .............. ........................................................................................................................ ............................................................ SOIL PIPES, Material ........................... Diameter ................4/ WASTE PIPES, Material .......... ...................................CA............................ ....It',................ . ... .... .......... Diameter ......... TRAPS,Type proposed to use is ... .................... ....... . . ... .. ....................................................................................................................................... RAINWATER LEADERS, where do they run to .. .................................................................................................................... REFRIGERATORWASTES, where do they run to .. .... ...................................................................................................... ............................... TANKOVERFLOWS, where do they run to .... .... ....... .................................................................................................................. C , FIXTURES WATER CLOSETS, How many .............. . ................. ...... Where located ... . .. ................................ ............................................... Distance from trap to vertical soil pipe ........................................ Pattern . ... .................. .................................................................. WASHTRAYS, How many .-- .... .. ........................................ Where located . . ................. ............................................................... SINKS, How many ................................ .......................................... Where located . . ............................. ..................................................... BUTLER'S SINKS, How many ........................................................ Where located. .. ................................................................................................ REFRIGERATORSINKS, How many...................................... Where located ................................................................................................... LAVATORIES,How many .. a ........ Where located .......................................................................... BATHTUBS,How many....................................................................... Where located ..................................................................................................... URINALS, How many ............................................................................ Where located ................................................................................................. Are water closets and urinals to be local vented - )00*.... .. If not, is there a window in outer wall ofroom where same are to be located ......... /Y6 . ....................................................................................................................................... Estimated Cost C;25_06 r...0.0. PERMIT # Application For 18 DEPARTMENT DECISION 1a- -o9 $� ' Permit 4 7 I o ( 3 APPLICATION IS HEREBY: DEPARTMENT OF LICENSES AND INSPECTIONS N APPROVED ❑ DISAPPROVED TOWN OF SOUTH WINDSOR 4 0 G® .c iy �°/vCo'✓ 74 00 O �/I/E F ddpECT4w APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE SEL W O V1 .a 0 '8 1. LOCATION OF JOB 1 � ® . .S�- � � � � WJ G NO. STREET cd 0 .L+ LOT NO. FLOOR APT. NO. O N E O C 2. OWNER ` O s. ADDRESS c, tj v C( C( Lo74�° ebc . 4.PHONE D S. . APPLICANT � �` s ,1 s Co I v� aid /1 a. ADDRESS 3 2 ��� �- `"��c_ 78 7.PHONE w •. LICENSE NO. Q o w II- EXPIRATION DATE OF LICENSE v 10. ESTIMATED COST scq ago ~ 11. IS THIS A CONTRACT COST?b0 ❑ YES �NO 12. FEE ENCLOSED S Permit 8 319 v I a. TYPE OF BUILDING: jJ� / be ❑ RESIDENTIAL L_7 COMMERCIAL O .0 r, ❑ Mc 3 14. TYPEE_/F JOB: INDUSTRIAL r+r �r 0 ORIGINAL ❑ ALTERATION INSTALLATION ADDITION REPAIR APPLICATION FOR HEATING PERMIT (C ntinued it m Reverse Side) \1. LOCATION OF JOB ��'�'��• N0. STREET FLOOR AFT.N0. ❑ OIL BURNER ClELECTRIC ❑ VENTILATION ❑ SPRINKLER 1Y. TYPE OF INSTALLATION; ❑ GAS BURNER ❑ STACK ❑ INCINERATOR ❑ MISCELLANEOUS P cf —r Imo/ 'A' IDENTIFY SIZE LOCATION SIZE SIZE 13. OF TANK OF TANK OF FILL OF VENT 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NO. B.T.U. OR SQ. FT. NET B.T.U. OR SO. FT. GROSS FIRING RATE FLOORS TO BE HEATED NEW OR OLD BUILDING INSULATED — YES OR NO TYPE OF WALL INSULATION ROOF OR CEILING INSULATION AVG. SYSTEM WATER TEMP. B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE °FAHRENHEIT MAKE OF RADIATION: BASEBOARD. COPPER CONVECTORS. OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SO. FT. OR B.T.U. DESCRIPTION OF WORK 15. TO BE DONE: .1 5 T l J ✓ C, c IG. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS): t v R oN slzE WINDOWS AREA — SQUARE FEET (.- e.T.U. 0.T.U. DISTRIBUTION INSTALLED AND DOORS VOLUME TOTAL TOTAL NO. 1tt �F� REGISTER R ON L W M AND W GROSS GLASS NETWALL CEILING FLOOR CU. AT�F CORTEOCTED j IL TYPE AND SIZE RAO. OR LEADER SIZE WALL ��GtO (INFiLT.) DIFF. •F I.: SO. FT. FREE AREA H m 75< TOTALS A. HEAT LOSS FROM BUILDING B.T.U./HR. B. DOMESTIC HOT WATER DEMAND B.T.U./HR. C. PIPING. OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY- NAME ADDRESS SUBCONTRACTORS AND �1�C4 -C— I s. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE(OWNER) OR (AGENT) OF THIS P PERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. w :l APPLICATION TO BE COMPLETELY FILLED IN. Z DA E SIGNA RE OF APPLICANT Y r TO THE BUE D INSPECTOR of rho APPLICATION' FOR TOWN OF PLAN EXAMINATION AND 50l)'tH W COW PLAN PERMIT z IMPORTANT — Applicant to complete all items in sections: 1, 11, III, IV, and IX. ZONING I I• AT (LOCATION I//rS �*t}_}t gaij i to DISTRICT LOCATION (NO.) (STREET) OF BETWEEN AND BUILDING (CROSS STREET) (CROSS STREET) LOT SUBDIVISION LOT BLOCK SIZE N II. TYPE AND COST OF BUILDING — All applicants complete Parts A — D A. TYPE OF IMPROVEMENT D. PROPOSED USE - For"Wrecking" most recent use r" 1 ❑ N w building Residential Nonresidential I 2 Additi n(11 residential, enter number 12 One family 18 U Amusement, recreati nal of new housing units added, if any, in Part D, 13) 13 ❑ Two or more family - Enter 19 ❑ Church, other religious number o/ units- - - - -i 20 .Industrial 3 ❑ Alteration (See 2 above) 14 ❑ Transient hotel, motel, 21 ❑ Parking garage 4 ❑ Repair, r placement or dormitory — Enter number 5 ❑ Wrecking (1/multifamily residential, of units ------- - i Service station, repair garaq enter number of units in building in 15 ❑ Garage 23 ❑ Hospital, institutional Part D, 13) 16 ❑ Carport 24❑ Office, bank, professional 6 ❑ M ving (rel cation) 17❑ Other - SpeciJy 25 ❑ Public utility 7 ❑ Foundation only 26❑ School, library, other educational B. OWNERSHIP 27❑ Stores, mercanti le 8 ® Private(individual, corporation, 28 ❑ Tanks, towers n npr fit institution, etc.) 29 ❑ Other — Specify 9 ❑ Public (Federal, State, or local government) C. COST (Omit cents) Nonresidential - Describe in detail proposed use of buildings, e.g., food processing plant, machine shop, laundry building at hospital, elementary 10. Cost of improvement,,,,,,,,,,,,,,,, S 116soM school, secondary school, college, parochial school, parking garage for. department store, rental office building, office building at industrial plant. To be installed but not included If use of existing building is being changed, enter proposed use. in the above cost a. El ctrical...................... b. Plumbing ...................... c. Heating, air conditioning......... d. Oth r(elevator, etc.)............ 11. TOTAL COST OF IMPROVEMENT s116,000 III. SELECTED CHARACTERISTICS OF BUILDING — For new buildings and additions, complete Parts E — L; for wrecking, complete only Part J, for all others skip to IV. E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS 301]Mas my (wall bearing) 40 Public or private company 48• Number of stories................ 31 ❑ Wo d framj 41 u Private (septic tank, etc.) 49• Total square feet of floor area, all floors, based on exterior 32❑ Structural steel dimensions ..................... 6,,48o 33❑ R inforced concrete H. TYPE OF WATER SUPPLY 50. Total land area, sq. ft. ........... 34❑ Other - Specify 42 Public or private company ' 43 Private(well, cistern) K. NUMBER OF OFF-STREET PARKING SPACES F. PRINCIPAL TYPE OF HEATING FUEL I. TYPE OF MECHANICAL 51. Enclosed ....................... Will th r be central air 52. Outdo rs.. 36 Oil c nditioning?. L. RESIDENTIAL BUILDINGS ONLY 37❑ Electricity 44❑ Yes 45 F-1 No 53. Number df bedrooms.............. 38❑ Coal 39❑ Other- Specify Will there be an el votor? Full.......... _ 54. Number f 46 E] Yes 47 R N bathrooms Partial........ Id. IDENTIFICATION — To be completed by all applicants Name Meiling eddr ss — .Number, street, c:tv, and State ZIP cod T I. No. 1. c x Owner or 'R a 0 J hl2 L I 1 �+ Lessee 2• Andre' Charbo ne u Contractor 3. Ira Davison Architect or Engineer 7 F The ownerjo this building and the undersigned agree to conform to all applicable laws of this jurisdiction. Si Address Application dot DO NOT WRITE BELOW THIS LINE V. PLAN REVIEW RECORD — For office use Plans R view Required Check Plan Review Date Plans By y Date Plans B Notes q Fee StartedA pproved BUILDING $ PLUMBING $ MECHANICAL $ ELECTRICAL $ OTHER w VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS Permit or Approval Check ObDta ate ned Number By Permit or Approval Check ObDtained Number By� BOILER PLUMBING CURB OR SIDEWALK CUT ROOFING ELEVATOR SEWER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OiL BURNER R€CKIlly OTHER OTHER VII. VALIDATION Bui Iding P rmit number /YL Bui Iding _ Permit issued //�7 .19 Building Permit Fe A rov d y: t TITLE s O TOWN OF S41TH WINDSOR BUILDII '' PERMIT - r i-+ Date Mr. 17 a+ 1986 Fee Paid ,$ 7 0 0 Est Valuq'$116 r 0 Permit 14 913 1 � r F on the aide of SCUMM Satellite Sava Street No. 5 R Owner CILAI ReCordil Tape Applicant w e Charrbonneau r CERTIFI TE 6F OCCUPANCY ISSUED: r D L No. Fee Paid !i CLASSIFICATION Addition f tl-� ----------------------------------------------------------- ----------------------- -- -------- BUILDING PERMIT NY 14913 OFFICE OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. Mar. 17 19 86 South Windsor, Conn. Trig iS tlt fajerti fg, That Andre Charbonneau is hereby granted permission to Addition at estimated value of $ 116 ,0 0 0 on the side of 145 South Satellite Road Sum on land owned by Central Record & Tape Said Work to be as described in Application No. 1 S 21 1 and to conform to specifications and plans filed with said Application, and Building By. Laws of THE TOWN OF SOUTH WINDSOR. Issued 19 86 ,-" uilding Inspector. Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: "When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costs and damages which it shall sustain, or be compelled to reason therefor." FINAL INSP S: Building APPLICATION FOR BUILDING PERMIT Plumbing - i` u HVAC Date: Sprinkler 145 SO. SATELLITE ROAD El ctric xt �0 cJ Estimated Cost $ 5,oo O Zoning Permit Fee$ oZSO Affidavit NO. 18106 Occupancy Fee $ Eng. Dept. COMPLETE RED BOXED AREAS. a.S3 Fire Dept. TYPE OR PRINT ONLY Total Fee $ Health Dept. Approved for CO: SIGN ON REVERSE SIDE. f (Additional Cost) $ TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Job Location J',Q. LK.CL Lot No. Side of Street Zone Applicant Tel. # --/.l"}7 Address .f L �d lJ_4 Zip 11/._n 7 Lic.# STREET GITY STATE Owner s�2f,��1 �� Address 117 Architect Address Size-tiew Area: Ft. Front Overall Ft. Deep Overall Total Area #Garages 4t Lavatories No. of Stories Construction Bathrooms Rooms 1st 2nd 3rd Size of Lot Dist. from Street Line Dist. from Side Street Line Purpose of this Permit 46'yoE- City Water La/ Well 0 Septic 0 Sewer 0 OR Approved by V Date BD 1 A >>/8s I h reby agree to conform to all the requirements of the Laws of the State of Connecticut and th Ordinanc s of th Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines required distances from all other zones and is located in a zone in which this building and its use is allowed. Signed - I hereby apply for a Certificate of Occupancy for the work described in this ication for permit. Signed —DO NOT WRITE BELOW THIS LINE— INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation Plumbing Permit# �y�� � Inspections: Z4 AL 2 C2 HVAC Permit# Inspections: Electrical Permit# ��J'`?� '" Inspections: Sprinkler Permit# Inspections: BUILDING INSPECTION DEPARTMENT SOUTH WINDSOR, CONNECTICUT ° FEE PAID: $3.00 CERTIFICATE OF OCCUPANCY ZONE: DATED &/2 5 1 9 90 This is to certify that^ 145 so. Sat-Pllite Road Altered under permit No. 18106 conforms substantially to the requirements of the building ordinances and the zoning regulations of the Town of South Windsor and is hereby approved for occupancy as indicated below. Approved for Occupancy— Renovate building for laundry service Use Gr up: F Constr. Type: 2C Building Official Notice:If this certificate is lost or destroyed, a duplicate should be obtained immediately from the Building Department. Any change or extension of the use herein approved requires a new certificate of occupancy. ` PERMIT # DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is hereby: TOWN OF SOUTH WINDSOR APPROVED DIS VED BUILDING INSPECTION DEPT. 644-2511 Ext . 230 1' Application must be printed or typed. Date Building Ins or 1. LOCATION OF JOB FEE SCHEDULE No . Street $ 0 - $19000 - $10.00 Floor Apt . No . Over $1,000 - $10.00 per $1,000 or 2 . OWNER LA)' L ,E" .D�EL -oYJ ��,�, D �:r��'`� fraction thereof 3. ADDRESS f t�r �'a ;z, S L L i TF b2--D 4. APPLICANT i7-0s"-qP1, 5 . ADDRESS ' ° 3 0 5' 31 FRQr"., � lvit 6 . ESTIMATED COST $ o 0 0 l 7 . IS THIS A CONTRACT COST xf- Yes No x9 8 . FEE ENCLOSED $ 9 . TYPE OF BUILDING: RESIDENTIAL kCOMMERCIAL 10. TYPE OF JOB : Original Installation �Alteration/Addition/Repair BD 3A 11/88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11 . LOCATION OF JOB -IK5 S a v ITT- S nA-- A b NO . STREET APT. NO 12 . TYPE OF INSTALLATION /tJ rr.✓ /,2.c� s4•--� �o o/2—7 7 -5 V c 13 . SIZE OF MAIN FEEDER U 14 . NO. OF LIGHT LOOPS 15 . NO. OF HEAT LOOPS 16. NO. OF POWER LOOPS 17 . NO. OF LIGHT OUTLETS 18 . NO. OF HEAT CIRCUITS 19. NO. OF POWER OUTLETS 20. NO. OF CONVENIENCE OUTLETS 21. NO. OF HEAT CIRCUITS 22 . NO. OF POWER CIRCUITS 23 . NO. OF LIGHT CIRCUITS 24. SIZE OF HEAT CIRCUITS 25 . NO. OF MOTORS 26 . NO. OF PANELS S 27 . TOTAL WATTAGE 28 . NO. OF POWER FEEDERS 29 . NO. OF SWITCHES 30 . A/C LOAD 31. SIZE OF POWER FEEDERS 32 . NO. OF FIXTURES 33. TOTAL HORSEPOWER 34 . NAME OF SUBCONTRACTORS AND THEIR TRADES 35 . REMARKS AND FURTHER DETAILS : LICENSE NO. SIGNATURE OF APPLICANT DATE PHONE NUMBER: w Lot No. Building Permit a Temporary Service i Permanent Service i Pursuant to Permit No. I This Certifies that the Electrical Work for which the above named Permit was granted has been duly inspected and is hereby approved. OwnerhA -utA V e Ir ' v Electrician Street !� 1 0 YA 19 Building` pector PERMIT # DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT l/g Application is hereby: TOWN OF SOUTH WINDSOR APPROV DISAPPROVED BUILDING INSPECTION DEPT. 644-2511 Ext . 230 l V w Application must be printed or typed. to Building Inspector 1. LOCATION OF JOB � v FEE SCHEDULE No . / Street $ 0 - $19000 - $10.00 Floor Apt . No. Over $1 ,000 - $10.00 oa4 per $1,000 or 2 . OWNER kl,�2 fraction thereofA3. ADDRESS Z (,( 4. APPLICANT dL C zs 5 . ADDRESS 6. ESTIMATED COST $ j 7 . IS THIS A CONTRACT COST y da Yes No 8. FEE ENCLOSED $ 9. TYPE OF BUILDING: RESIDENTIAL C1,16OMMERCIAL 10. TYPE OF JOB : Original Installation _LAlteration/Addition/Repair BD 3A 11/88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11 . LOCATION OF JOB ` _(� �Pi /- 4,�/ NO . STR ET APT. NO 12 . TYPE OF INSTALLATION 13. SIZE OF MAIN FEEDER 14 . NO. OF LIGHT LOOPS 15 . NO. OF HEAT LOOPS 16. NO. OF POWER LOOPS 17 . NO. OF LIGHT OUTLETS 18 . NO. OF HEAT CIRCUITS 19 . NO. OF POWER OUTLETS 20. NO. OF CONVENIENCE OUTLETS 21. NO. OF HEAT CIRCUITS 22 . NO. OF POWER CIRCUITS 23 . NO. OF LIGHT CIRCUITS 24. SIZE OF HEAT CIRCUITS 25 . NO. OF MOTORS 26. NO. OF PANELS 27 . TOTAL WATTAGE 28 . NO. OF POWER FEEDERS 29 . NO. OF SWITCHES 30. A/C LOAD 31. SIZE OF POWER FEEDERS 32. NO. OF FIXTURES 33 . TOTAL HORSEPOWER 34 . NAME OF SUBCONTRACTORS AND THEIR TRADES 35 . REMARKS AND FURTHER DETAILS : U Pr, r� sus G . � /fz2- vj .AL Z2yc'), LICENSE NO. SIGNATURE OF APPLICANT DATE PHONE NUMBER: ' �� r PERMIT NO. sly DEPARTMENT DECISION APPL I CAT I O N FOR Application is hereby : PLUMBING PERMIT TOWM OF SOUTH WINDSOR APPROVED DISAPPROVED BUILDING INSPECTION DEPT. 644-2511 Ext. 230 Date Bu ng Inspector Application must be printed or typed. 1. LOCATION OF JOB: FEE SCHEDULE 2. OWNER: $ 0 - $19000 - $10.00 3. ADDRESS: 7� S G� A00 Over $1 ,000 $10.00 per $1 ,000 or 4. APPLICANT: fraction thereof .- • 5. ADDRESS: (2 Ala /flw vY ler, rtL.,/ U� yC 6. EST. COST: 7. IS THIS A CONTRACT COST? YES ENO 8. FEE ENCLOSED: $ L -WAMAgA 9. TYPE OF BUILDING: o/s/-61 RESIDENTIAL 1'COMMERCIAL 10. TYPE OF JOB: ORIGINAL ALTERATION INSTALLATION ADDITION REPAIR BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: GENERAL PLUMBING 12. KIND OF INSTALLATION: 13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS STYLE 15. NO. OF URINALS STYLE 16. NO. OF BATHTUBS 16A. NO. OF SHOWERS 17. NO. OF LAVATORIES 18. NO. OF SINKS 19. DISPOSAL 19A. DISWASHER 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS SIZE 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK? 31. SIZE OF WATER MAIN 31A. SIZES OF WATER PIPING & RISERS _ 32. REMARKS AND FURTHER DETAILS WATER HEATER 33. TYPE 34. MANUFACTURER TANKS SAFETY DEVICES TE1PERATURE 35. CAPACITY 39. RELIEF VALVE 36. TEST PRESSURE LBS. 40. MANUFACTURER 37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE 38. TYPE 42. MANUFACTURER '2 o? S �o LICENSE NO. ' DATt SIGNATURE OF AP ICANT PHONE NO. � T l PERMIT NO. DEPARTMENT DECISION APPLI CAT ION FOR Application is hereby : PLUMBING PERMIT TOWM OF SOUTH WINDSOR APPROVED DISAPPROVED BUILDING INSPECTION DEPT. 644-2511 Ext. 230 Date /-,�lding Inspector Application must be printed or typed. 1. LOCATION OF JO`B`'S SGz 146L11 mob& Lar ��r�L~ FEE SCHEDULE 2. OWNER: 3. ADDRESS: P4 73,RS yLq A7 $ 0 - $19000 - $10.00 _ Over $1 ,000 - $10 .00 /VcSJ per $1 , 000 or 4. APPLICANT: fraction thereof 5. ADDRESS: Ales �?2 6. EST. COST: $ SoDo t 7. IS THIS A CONTRACT COST? YES j//NO 8. FEE ENCLOSED: 9. TYPE OF BUILDING: RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: ORIGINAL ALTERATION INSTALLATION ADDITION REPAIR BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: � Sle Z I+T2 GENERAL PLUMBING 12. KIND OF INSTALLATION: 13. SIZE OF MAIN DRAIN (p 14. NO. OF TOILETS STYLE 15. NO. OF URINALS STYLE 16. NO. OF BATHTUBS 16A. NO. OF SHOWERS 17. NO. OF LAVATORIES 18. NO. OF SINKS 19. DISPOSAL 19A. DISWASHER 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS SIZE 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? / y-Zu S T a u 29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK? 31. SIZE OF WATER MAIN 4 4 31A. SIZES OF WATER PIPING & RISERS 32. REMARKS AND FURTHER DETAILS ✓ l c< WATER HEATER 33. TYPE 34. MANUFACTURER TANKS SAFETY DEVICES TEMPERATURE 35. CAPACITY 39. RELIEF VALVE 36. TEST PRESSURE LBS. 40. MANUFACTURER 37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE 38. TYPE 42. MANUFACTURER LICENSE NO. DATE SIGNATURE OF APPLIC PHONE NO. bnnecticut Veparftmt of Public'Saf ty h 10 of St t Police iP-1009-C BUREAU OF STATE FIRE MARSHAL INVESTIGATION REPORT s N r. Charact r of Case: Dot of Report: P90-OQ �9- June 20 1990 Report By: Tovin GAS FIRED HOT WATER South Windsor HEATER (INDUSTRIAL) Pagel of: Insp. T.H. Ray #2877 1 Pag s { INITI AL SUPPLEMENTARY Fmi CLOSING D Summary: Daniel Tierney of the State Building Inspectors Office requested assistance with an inspection of an unlisted industrial hot water heater unit installation. Action Taken: On June 20, 1990 this Inspector. Fire Marshal William Lanning and Chief Building Official John Collins of the Town of South Windsor met to conduct the inspection. The installation is located at the Cupid Laundry in the South Windsor Industrial Park. The subject hot water heater is manufactured by Kemco Systems, Inc. , 11880 29th street north, St. Petersbury, F1 33716-1815 and is rated at 200 gallons of hot water per minute. The proposed unit installation in Ellington, CT is a 750,000 btu per hour input of similar design. Neither unit, however, is A.G.A. or U.L. listed. The applicable regulations referenced in NFPA #54 (National Fuel Gas Code), dated 1974 contains provision for the installation of unlisted gas fired equipment (Sec. 5.1.1). The hot water heater appeared to be installed in accordance with the provisions of NFPA #54. All gas related components appeared to be U.L. listed. However, examination of the unit in operation disclosed that it had vibrated enough to break solder ioints made up with 95/5 solder. Doubled two by fours were found braced against the wall and wiping in an attempt to dampen the vibrations. Thw owners of Cupid Laundry were subseauently by ordered by Building Inspector John Collins to have the unit repaired by a factory represen- tative or he would order the hot water heater shut down. Inspection was terminated pending completion ofAINSTIGATING air . Case Open. o� �> ENDORSING OFFICER OFFICER 2nnec ti cu t pep ar tmen t of Public'Sa f ty ivision of St t P lice BUREAU OF 'STATE FIRE MARSHAL P-1008-C INVESTIGATION REPORT s N r. Charact r of Cas : Dat of Report: June 22 1990 P9 - - Tovrn: Report By: GAS FIRE HOT WATER HEATER (INDUSTRIAL) Page 1 of: � Pag s Insp. T.H. Raj #2877 sonvownINITI AL M SUPPLEMENTARY ® CLOSING Action Taken: On June 229 1990 this Inspector spoke with John R. Collins, Chief Building Official for the Town of South Windsor. Mr. Collins stated that he had observed the factory representative correct the virbration problem in the hot water heater. Apparently a hot water feed valve on the unit was out of adjustment causing a pulsation that was magnified by the piping, As the problem has been corrected by the manufacturer the unit appears to be in compliance with the provisions of NFPA #54 as an unlisted, hot water heater for the service intended. Case Closed. ,e4w AO, a� ENDORSING OFFICER A G 10FFICER FINAL INSPE TI Building APPLICATION FOR BUILDING PERMIT Plumbing oq HVAC Date: � Sprinkler 145 S0. SATELLITE ROA Electric Estimated Cost $ Zoning 21955 Permit Fee $ Affidavit NO. Occupancy Fee $ Eng. Dept. COMPLETE RED BOXED AREAS. J� Fire D pt. Total Fee $ TYPE OR PRINT ONLY Health Dept. SIGN ON REVERSE SIDE. Approved for CO: - (Additional Cost) $ TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Job Location a- Lot No. Side of Street Zone Applicant Tel. # Address 1 2 Cl- Zip 0 Lic.# SP41EET CITY S7ATE Owner ddress Architect Address Size New Area: Ft. Front Overall Ft. Deep Overall Total Area #Garages Lavatories Size of Lot Dist. from St r et Line Bathrooms Rooms 1st 2nd 3rd Purpose of this Permit r-t City Water 0 Well 0 Septic 0 Sewer O Use Group l&I Construction Type Approved by dP- Date �� �� BD1A 11/88 I hereby agree to conform to all th requirem nts of th Laws of th State of Conn cticut and th Ordinanc s of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Buildi for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard li es a e ired distances from all other zones and is located in a zone in which this building and its use is allowed. Signed I hereby apply for a Certificate of Occupancy for the work described in this application for permit. Signed —DO NOT WRITE BELOW THIS LINE— INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation Plumbing Permit# Inspections: HVAC Permit# Inspections: Electrical Permit# Inspections: Sprinkler Permit# Inspections: Electric# APPLICATION FOR BUILDING PERMIT Plumbing# 145 so. SATELLITE ROAD Date: HVAC # 23389 _ V1&6 No. Sprinkler# FINAL APPROVAL Estimated Cost $ m) Building '7 COMPLETE RED BOXED AREAS Permit Fee $ /Zl-<) Engineering TYPE OR PRINT ONLY Occupancy Fee $ Affidavit SIGN ON REVERSE SIDE Appr.for CO. Total Fee $ LO TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR,CT (Additional Cost) $ The undersigned hereby applies to do work according to the following specifications: Job Location 145 So. Satellite Rd. Lot No. Side of Street Zone Applicantnndre' r harbonnaau & SQns Tel.# '71f,1/ Address , 2 Bawin Roadip so- - windeezv., n+. Zip 06074 Lic. # Owner —F. S Sd C199 GAS Address 00 A nEL.z. l 7-4- RI) S- Architect Address Sq. Ft.New Area: lst FI. 2nd FI. 3rd FI. Total New Area #Rooms # Lavatories #Bathrooms #Garages Purpose of this permit:Construct Concrete slab with founclat•i n ri:-tiiig paved area. City Water 2- Well 0 Septic System ❑ Sewer 2 Us Group Construction Type /v Area / Base ent Garage Approved by Date R•v:.d 6/95 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zon in which this building and its use is allowed. Signed I hereby apply for a Certificate of Occupancy for the work described in this application for the permit Signed -- DO NOT WRITE BELOW THIS LINE -- INSPECTION COMMENTS 'OVI Sfq y , _ G 1540 SULLIVAN AVENUE SOUTH WINDSOR, CONN. 06074 soR co AREA CODE 860/644-2511 September 26, 1996 CEASE AND DESIST Hand Delivered E.K. Associates Cupid Diaper Service Mr. Morton Koppel - Secretary/Treasurer 145 South Satellite Road South Windsor, CT 06074 LOCATION: 145 South Satellite Road. Dear Mr. Koppel: ZONE: Industrial SOUPS WINDSOR REGULATION SECTION: Section 6.1.5.2 Storage of material, Section 8.1 Site development plan. TYPE OF VIOLATION: The erection of a structure without site plan approval. Section 6.1.5.2 Storage of Material, plastic carts are being stored on the property north of the parking area. Section 13.1.2 employee and visitor parking is not being accommodated in parking shown on the original site plan. A review of impervious coverage is needed, the proposed structure may exceed allowable impervious coverage requirements Section 10.2. CORRECTIVE ACTION REQUIRED: Cease all construction activities. Immediately remove the illegal structure. Submit an up to date site plan for review and approval by the Planning and Zoning Commission using the enclosed Site Plan Checklist as a guide. Absolutely no use is allowed on the existing illegal structure until the proper approvals and permits have been acquired. Failure to comply with the terms of this notice will result in referral to the Town Attorney for legal action. If 31. 1 have any questions regarding this matter, feel free to cont, t me at 644-2511, ext. 229. Sincerely, Jeffrey H. Folger Zoning/Wedand Enforcement Officer CC: Planning/Zoning Commission Director of Planning Town Manager Town Attorney Sectric# APPLICATION FOR BUILDING PERMIT Plumbing# 145 S 0. SATELLITE ROAD Dat : La-?) IC4 WAC # No. 24840 Sprinkler# FIMAPPROVALS Estimated Cost Building 2 7 �3 KQ— COMPLETE RED BOXED AREAS Permit Fee $ Engineering TYPE OR PRINT ONLY Occupancy Fee Affidavit SIGN ON REVERSE SIDE Appr.for CO. [: Total Fee TO BULDlt-C DEPARTM W,TOWN OF SOUTH Wt4DSOR,CT (Additional Cost) $ The undersigned hereby applies to do work according to the following specifications: Job Location 1 k 51 SaA<-t 1 J Lot No. Side of Street Zone Applicant l JAL"rc>,A c Tel# Address 43— ibp C!L<:j L.c, 5N nASbvuy u Lic.# P1;T-ZaA(n 2¢. Owner-,�ak��. � : �� Address ocs SOc�—jt't-t Sc � 1 -�-R Architect Address Sq.Ft.N w Area: ]st Fl. 2nd Fl. 3rd Fl. Total New Area #Rooms #Lavatories #Bathrooms #Garages Purpose of this permit: 9.,ejMox)s�- � c, City Water ❑ At Well ❑ Septic System 0 Sewer ❑ Ins. H.O. P. Cert. � Area i Basement Garage Approved by i5D Dot 1 S Use Group Construction Type RwiNd 1197 INSPECTION COMMENTS APPLICATION FOR BUILDING PERMIT Electric CD a` 145 SO. SATELLITE ROAD Plumbing# I o SS3 HVAC # 10 7610 26659 Date: �L-70 4`1 Sprinkler# NO' FINAL APPROVALS Estimated Cost b Uo O Building 3o cJu `l.C.Q_ COMPLETE RED BOXED AREAS Permit Fee $ (�SU Engineering TYPE OR PRINT ONLY Occupancy Fee $ Affidavit SIGN ON REVERSE SIDE Appr.for CO. G�3o ��N Total Fee $ L S TO BUILDING DEPARTM W,TOWN OF SOUTH WN)SOR,CT (Additional Cost) $ The undersigned h reby applies to do work according to the following specifications: Job Location /�/S SOVT� S��E 1�� /�� Lot No. Side of Street Zone Applicant AIV W C C Allf-e Qp N Nb19 y &0 NS Tel# 3Jcf-7,SS l Address (2.!;- EDW(&-' �lO SO UT-f f w fovo s o 2 Zip O C,)O-�l Lic.# Own r 0 N i I& e r P Address 14� ,SOU rG. �;,a f6//i 716 PCI Architect Address Sq. Ft.New Area: 1st FI. 7-�CO0 2nd Fl. 3rd Fl Total New Area 2coo O #Rooms #Lavatories #Bathrooms #Garages Purpose of this permit: 461VC ASt &x SST/NC 40/tQ1•v6 ID 0 C k- htt f 4 c.✓r f� /����' V C"{veL City Water ❑ Well ❑ Septic System ❑ Sewer ❑ Ins. H.O. S.P. Cert. VArea Basement Garage Approved by /46,#E�et_ Dat fl/96A2 Use Group Construction Type 39 Rovwpd 1197 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which building and its use is allowed. >eSigned I hereby apply for a Certificate of Occupancy for the work described inthis application for the permit. iy=igned DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Inspection / Approval Date By Appl Code Description Due Whom Code Commend ------------------------------------------------------------------------------- 99-26659-B 50,000 P02 UNDERGROUND 02/24/00 JFF A WITH CONTRACTOR P03 ROUGH 02/24/00 JFF A WITH CONTRACTOR B03 FRAMING (ROUGH) 12/15/99 JRC A MASONRY WALLS E03 ROUGH O1/17/00 JRC A B10 FINAL 03/01/00 JRC A **-16622-E 8,000 [Date RTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT PERMIT# plication is hereby: TOWN OF SOUTH WINDSOR i\ � BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# y �� 644-2511 ext. 230 Building Inspector Application must be printed or typed Location of Job: FEE SCHEDULE $0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= f $13.00 per$1,000 Apt.No. t or any fraction thereof Tenant Designation P cq v�`G I j c.�vvvG= APPLICANT 727 f .1 ` APPLICANT ADDRESS • ` r o APPLICANT PHONE# OWN St-4 OWNER U i T'zf Yc � OWNER ADDRESS �, IU'1 TLC Y. -),r lJ %x OWNER PHONE U Jai i 'i-C. c cl r A��7 C ESUMATED COST$ )"Feyy,oo IS THIS A CONTRA!i& COST? `Yes 0 No �CJ FEE ENCLOSED$ Y.oa TYPE OF JOB: SOR-CD Wkew Installation 13 Alteration/Addition/Repair Revised 8/99 f APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? ❑ YES ❑NO ❑RESIDENTIAL QtUSINESS CURRENT USE AND OCCUPANCY ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY A vv►e" ❑EDUCATIONAL ❑INSTITUTIONAL ENGINEER'S NAME I ►Q C PHONE ❑FACTORY ❑ STORAGE ADDRESS ❑GARAGE LrMIXED USE CITY STATE ZIP (Other please specify) TYPE OF INSTALLATION/WIRING METHOD EYwr �' u��lcv i �' 'M4 14 K) (f�yu d OC To r n� SIZE OF SERVICE t—::Xi i SIZE OF MAIN CONDUCTORS NUMBER OF METERS 1 NUMBER OF DISCONNECTS AND RATINGS rl NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? ❑YES U'<1O NUMBER OF LIGHT CIRCUITS Ucw NUMBER OF POWER CIRCUITS I "CtO NUMBER OF SWITCHES 2JUCW NUMBER OF OUTLETS JY Ale(,L) NUMBER OF LIGHT FIXTURES 0 NUMBER OF HEAT CIRCUITS we-Lo NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK J c2S THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE TYPE STATE SIGNATURE OF APPLICAN DATE DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT TOWN OF SOUTH WIl�TDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# �i1A 644-2511 ext. 230 atef ilding Inspector Application must be printed or typed Location of Job: FEE SCHEDULE RL $0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= $13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. WMMM l APPLICANT APPLICANT ADDRESS SO jiy t ✓� ��o� �� APPLICANT PHONE# mA W N 3 OWNER Cf,0,P l)A) O OWNER ADDRESS S • s Q.61t U� OWNER PHONE C ESTIMATED COST$ 5 ��- * V �'�► IS THIS A CONTRACT COST? O Yes IT No { �CJ FEE ENCLOSED$ C TYPE OF JOB: SOR-CO O New Installation *rAlteration/Addition/Repair Revised 8/99 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? id YES ❑NO ❑RESIDENTIAL ❑BUSINESS CURRENT USE AND OCCUPANCY CG 1M Yv'\° 0 L ❑ASSEMBLY ❑MERCANTILE FUTURE USE AND OCCUPANCY n!' ❑EDUCATIONAL �Otcj �, 1❑INSTITUTIONAL ENGINEER'S NAME Al ChX f g V t O Jay PHONE �_0 jd FACTORY f ❑ STORAGE ADDRESS —, ❑GARAGE ❑MIXED USE CITY (Alt STATE CT ZIP t (Other please specify) TYPE OF INSTALLATION (ZT-Yy►z/4, �j yt 0 SIZE OF MAIN DRAIN G� NO.OF TOILETS STYLE NO.URINALS 1 STYLE (AP, Q&tvy`' NO.OF BATHTUBS NO.OF SHOWERS `— NO.OF LAVATORIES / NO.OF CONDUCTORS SIZE NO.OF STACKS SIZE AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES f KIND .� ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW ❑YES W NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER 0- WATER HEATER: TYPE MANUFACTURER Ily 01 DESCRIPTION OF WORK 1,4 THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE S PERFORMANCE OF SUCH�W'ORK. p[ 0 C1_a-,tl tat c 7- CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE (� e/� DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR f G #7 0 BUILDING DEPARTMENT PRO 1540 SULLIVAN AVENUE Bldg.Permit#24 � 1400 644-2511 ext. 230 C,0 Date Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: � 0 $0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= $13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. I q � I APPLICANT � F /�E� `�/ S 1/,E APPLICANT ADDRESS 2 � APPLICANT PHONE# 2- — Ll q4� OWN 3 OWNER ' Z/t— !`� 1� t1- q� OWNER ADDRESS y So , S /���LL- /7` (,�� So, zj l A i /)S a1Z ' OWNER PHONE _7 O ao C ESTIMATED COST$ 2 2 o O • �l U IS THIS A CONTRACT COST? )%Yes 0 No �J FEE ENCLOSED$ J TYPE OF JOB: 490 CO stew Installation 0 Alteration/Addition/Repair Revised 8/99 i 1 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: ❑HEATING ❑RESIDENTIAL ❑A/C WOMMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC ❑WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION :❑INSIDE❑OUTSIDE CAPACITY ❑GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. � C) 2- V 6 V CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT. DATE E E Z G Plimpton & Hills Corp. Springfield/Hartford 1-800-582-3161 BTUH LOSS 184294 GAIN 67349 320.51 BASEBOARD FT. @ 575 BTU/FT @ 180 F. ROOM NUMBER 1 2 3 4 ROOM NAME MAIN HEIGHT 25 .00 LENGTH 51 .00 WIDTH 39.00 EXPOSED WALL LENGTH 90 .00 # WALLS WITH OPENINGS 2 EXPOSED GLASS AREA 180 .25 L INFILTRATION .027 83240 0 CEILING .11 13565 S FLOOR SQ FT S SLAB LINEAR FT 0 .53 2957 E COLD PARTITION 0.33 46035 S WALL 0 .30 38497 GLASS TOTAL LOSS @ 62 DTD 184294 BASEBOARD FEET @ 180 320.5 GAIN 67349 ROOM NUMBER 5 6 7 8 ROOM NAME HEIGHT LENGTH WIDTH EXPOSED WALL LENGTH # WALLS WITH OPENINGS EXPOSED GLASS AREA L INFILTRATION 0 CEILING S FLOOR SQ FT S SLAB LINEAR FT E COLD PARTITION S WALL GLASS TOTAL LOSS @ 62 DTD BASEBOARD FEET @ 180 GAIN