Loading...
HomeMy WebLinkAbout15 Bancroft Lane (4) DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# TOWN OF SOUTH WINDSOR Application is hereby: BUILDING DEPARTMENT No o APPRO 1540 SULLIVAN AVENUE f 644-2511 ext. 230 Bldg.Permit# ]Jatd Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: .F (3*V ie4Pr-T 14A14 $0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= $13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT 4,0,rjV Et- 4410;4AIV . Gc APPLICANT ADDRESS cTO ?pL �/,Q S' T" &KT CT_ 06 !og APPLICANT PHONE# f(,90 Agtl 10%,O W p S F,q OWNER s7Z�A/E C2AE,-r>T C0 N Srgs-c no/J t r' OWNER ADDRESS a �lt�T�1 cnI�/vOSv�. CT 066 0_! ` " 4 E•► OWNER PHONE C ESTIMATED COST$ /D, , - 0 , * V IS THIS A CONTRACT COST? ;K Yes 0 No FEE ENCLOSED$ SpR. O�� TYPE OF JOB: C 13,New Installation 0 Alteration/Addition/Repair Revised 8/99 1 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: f,HEATING K RESIDENTIAL Ji(A/C ❑ COMMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC A WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE -✓s OF INSIDE 7& - °F DIFFERENCE 7s OF TOTAL HEAT LOSS(BTUH)J129�°F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) �,�►?rf c STrINO40ejDj GROSS HEATING CAPACITY(INPUT—BTUH) /00�a00 NET RATING(OUTPUT—BTUH) �ai d o TYPE OF FUEL ❑ OIL—GPM OIL TANK LOCATION :❑INSIDE❑ OUTSIDE CAPACITY '&GAS—INPUT 0o LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE�OF INSIDE�OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) 10 6z (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) 2W0/" 7 Igo 0 ylyA too 4 7x ok o TONNAGE 3 k COOLING CAPACITY(BTUH)SOD VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK CO1M� S LNG. tY &l.MKOF s . THE UNDERSIGNED HE BY APPLIES FOR A PERMIT TO PERFORM THE WO�1� ESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 30 7 S- cr CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE Right-A Work heet Job: 33 Bancroft Lan oEntire House M Nov.5,2002 Kasd n Fu I Company Ely: DJS J 340 Tolland Street,East Hartford,CT 06108 Phone:860-289-5431 Fax 860-289-2133 Email:dansymolon@aol.com 1 Room name Entire House Room1 2 Exposed wall 210.0 ft 104.0 ft 3 Ceiling h ight 9.9 ft d 12.0 ft heat/cool 4 Room dimensions 40.0 x 24.0 ft 5 Room ar a 1974.0 ft2 960.0 ft2 Ty Construction U-value Or HTM Area Load Area (ft� Load number (Btuh/ft2--F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12C-Osw 0.091 n 5.82 1.75 408 387 2254 678 288 267 1555 468 E--D 11 DO 0.390 n 24.96 9.46 21 21 524 199 21 21 524 199 Val 12C-Osw 0.091 e 582 1.75 688 556 3238 974 480 393 2289 688 I---G 1 D-c2ow 0.570 a 36.48 60.15 132 0 4815 7939 87 0 3174 5233 11 IW 12C-Osw 0.091 s 5.82 1.75 312 282 1642 494 0 0 0 0 �---G 1 D-c2ow 0.570 s 36.48 31.61 30 0 1094 948 0 0 0 0 W 12C-Osw 0.091 w 5.82 1.75 688 547 3186 958 480 399 2324 699 �' 1 D-c2ow, 0.570 w 36.48 60.15 120 0 4378 7217 60 0 2189 3609 11 DO 0.390 w 24.96 9.46 21 21 524 199 21 21 524 199 C 1613-30ad 0.032 - 2.05 1.53 1974 1974 4043 3016 960 960 1966 1467 F 19C-19cscp 0.049 - 1.09 0.22 1974 210 2146 443 960 104 1044 215 Envelope loss/gain 27845 23065 15588 12776 12 a) Infiltration 13811 1424 8223 848 b) Ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 41656 24489 23812 13624 15 Duct loads 15% 17% 6122 4133 15% 17% 3499 2299 Total room load 1 1 47777 28623 1 1 27311 15923 Air required(cfm) 1532 1532 876 852 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. -� wr1g"1tsoft Right-Suite Residential J8 5.8.15 RSR30950 2002-Nov-05 06:05:32 AA C:Wy Documents\Wrightsoft HVAC\TemplateU)rojectl.rrt Calc=MJ8 Orientation=W Pag 1 Right-A Work heet J b: 33 Bancroft Lane ° Entire House Date: "°".s,2002 By: DJs Ka d n Fu I Company 340 Tolland Street,East Hartford,CT 06108 Phone:860-289-5431 Fax 860-289-2133 Email:dansymolon@aol.com 1 Room name Room2 2 Exposed wall 106.0 ft 3 Ceiling height 8.0 ft heat/cool 4 Room dimensions 26.0 x 39.0 ft 5 Room area 1014.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 W 12C-Osw 0.091 n 5.82 1.75 120 120 699 210 (— D 1111130 0.390 n 24.96 9.46 0 0 0 0 12C-Osw 0.091 a 5.82 1.75 208 163 949 286 1 D-c2ow 0.570 a 36.48 60.15 45 0 1642 2707 11 WI _ 12C-Osw 0.091 s 5.82 1.75 312 282 1642 494 �---c. 1 D-c2ow 0.570 s 36.48 31.61 30 0 1094 948 W 12C-Osw 0.091 w 5.82 1.75 208 148 862 259 �Gp 1 D-c2ow 0.570 w 36.48 60.15 60 0 2189 3609 11 DO 0.390 w 24.96 9.46 0 0 0 0 C 166-30ad 0.032 - 2.05 1.53 1014 1014 2077 1549 F 19C-19cscp 0.049 - 1.09 0.22 1014 106 1102 227 Envelope loss/gain 12256 10289 12 a) infiltration 5588 576 b) Ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances @ 1200 0 0 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 17844 10866 15 Duct loads 15% 17% 2622 1834 Total room load 20466 12699 Air required(cfm) J 656 680 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. �- wrvg"ts >Ft Right-Suit R sid ntial J8 5.8.15 RSR30950 2002-Nov-05 06:05:32 AM CAMy DocumentslWrightsott HVAC\TemplatelProjectl.rtt Calc=MJ8 Orientation=W pasow