HomeMy WebLinkAbout15 Bancroft Lane (4) DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT
PERMIT#
TOWN OF SOUTH WINDSOR
Application is hereby: BUILDING DEPARTMENT No o
APPRO 1540 SULLIVAN AVENUE
f 644-2511 ext. 230
Bldg.Permit#
]Jatd Building Inspector
Application must be printed or typed
FEE SCHEDULE Location of Job:
.F (3*V ie4Pr-T 14A14
$0-$1,000=$13.00 Street No. Street Lot No.
Over$1,000=
$13.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT 4,0,rjV Et- 4410;4AIV
. Gc
APPLICANT ADDRESS cTO ?pL �/,Q S' T"
&KT CT_ 06 !og
APPLICANT PHONE# f(,90 Agtl
10%,O W p S F,q OWNER s7Z�A/E C2AE,-r>T C0 N Srgs-c no/J
t r' OWNER ADDRESS
a �lt�T�1 cnI�/vOSv�. CT 066
0_! ` " 4 E•► OWNER PHONE
C ESTIMATED COST$ /D, , - 0 ,
* V
IS THIS A CONTRACT COST? ;K Yes 0 No
FEE ENCLOSED$
SpR. O�� TYPE OF JOB:
C
13,New Installation
0 Alteration/Addition/Repair Revised 8/99
1
APPLICATION FOR HVAC PERMIT (Continued from reverse side
TYPE OF SYSTEM: TYPE OF BUILDING:
f,HEATING K RESIDENTIAL
Ji(A/C ❑ COMMERCIAL
❑VENTILATION ❑INDUSTRIAL
HEATING
❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
❑HYDRONIC A WARM AIR ❑UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE -✓s OF INSIDE 7& - °F DIFFERENCE 7s OF
TOTAL HEAT LOSS(BTUH)J129�°F(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
�,�►?rf c STrINO40ejDj
GROSS HEATING CAPACITY(INPUT—BTUH) /00�a00 NET RATING(OUTPUT—BTUH) �ai d o
TYPE OF FUEL
❑ OIL—GPM OIL TANK LOCATION :❑INSIDE❑ OUTSIDE CAPACITY
'&GAS—INPUT 0o LPG TANK CAPACITY ELECTRIC—KW
AIR CONDITIONING
DESIGN TEMP.OUTSIDE�OF INSIDE�OF DIFFERENCE OF
TOTAL HEAT GAIN(BTUH) 10 6z (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
2W0/" 7 Igo 0 ylyA too 4
7x ok o
TONNAGE 3 k COOLING CAPACITY(BTUH)SOD
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK CO1M� S
LNG.
tY &l.MKOF s .
THE UNDERSIGNED HE BY APPLIES FOR A PERMIT TO PERFORM THE WO�1� ESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
30 7 S- cr
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT DATE
Right-A Work heet Job: 33 Bancroft Lan
oEntire House M Nov.5,2002
Kasd n Fu I Company Ely: DJS J
340 Tolland Street,East Hartford,CT 06108 Phone:860-289-5431 Fax 860-289-2133 Email:dansymolon@aol.com
1 Room name Entire House Room1
2 Exposed wall 210.0 ft 104.0 ft
3 Ceiling h ight 9.9 ft d 12.0 ft heat/cool
4 Room dimensions 40.0 x 24.0 ft
5 Room ar a 1974.0 ft2 960.0 ft2
Ty Construction U-value Or HTM Area Load Area (ft� Load
number (Btuh/ft2--F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 12C-Osw 0.091 n 5.82 1.75 408 387 2254 678 288 267 1555 468
E--D 11 DO 0.390 n 24.96 9.46 21 21 524 199 21 21 524 199
Val 12C-Osw 0.091 e 582 1.75 688 556 3238 974 480 393 2289 688
I---G 1 D-c2ow 0.570 a 36.48 60.15 132 0 4815 7939 87 0 3174 5233
11 IW 12C-Osw 0.091 s 5.82 1.75 312 282 1642 494 0 0 0 0
�---G 1 D-c2ow 0.570 s 36.48 31.61 30 0 1094 948 0 0 0 0
W 12C-Osw 0.091 w 5.82 1.75 688 547 3186 958 480 399 2324 699
�' 1 D-c2ow, 0.570 w 36.48 60.15 120 0 4378 7217 60 0 2189 3609
11 DO 0.390 w 24.96 9.46 21 21 524 199 21 21 524 199
C 1613-30ad 0.032 - 2.05 1.53 1974 1974 4043 3016 960 960 1966 1467
F 19C-19cscp 0.049 - 1.09 0.22 1974 210 2146 443 960 104 1044 215
Envelope loss/gain 27845 23065 15588 12776
12 a) Infiltration 13811 1424 8223 848
b) Ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances @ 1200 0 0 0 0
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 41656 24489 23812 13624
15 Duct loads 15% 17% 6122 4133 15% 17% 3499 2299
Total room load 1 1 47777 28623 1 1 27311 15923
Air required(cfm) 1532 1532 876 852
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
-� wr1g"1tsoft Right-Suite Residential J8 5.8.15 RSR30950 2002-Nov-05 06:05:32
AA C:Wy Documents\Wrightsoft HVAC\TemplateU)rojectl.rrt Calc=MJ8 Orientation=W Pag 1
Right-A Work heet J b: 33 Bancroft Lane
° Entire House Date: "°".s,2002
By: DJs
Ka d n Fu I Company
340 Tolland Street,East Hartford,CT 06108 Phone:860-289-5431 Fax 860-289-2133 Email:dansymolon@aol.com
1 Room name Room2
2 Exposed wall 106.0 ft
3 Ceiling height 8.0 ft heat/cool
4 Room dimensions 26.0 x 39.0 ft
5 Room area 1014.0 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area Load
number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter
Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool
6 W 12C-Osw 0.091 n 5.82 1.75 120 120 699 210
(— D 1111130 0.390 n 24.96 9.46 0 0 0 0
12C-Osw 0.091 a 5.82 1.75 208 163 949 286
1 D-c2ow 0.570 a 36.48 60.15 45 0 1642 2707
11 WI _ 12C-Osw 0.091 s 5.82 1.75 312 282 1642 494
�---c. 1 D-c2ow 0.570 s 36.48 31.61 30 0 1094 948
W 12C-Osw 0.091 w 5.82 1.75 208 148 862 259
�Gp 1 D-c2ow 0.570 w 36.48 60.15 60 0 2189 3609
11 DO 0.390 w 24.96 9.46 0 0 0 0
C 166-30ad 0.032 - 2.05 1.53 1014 1014 2077 1549
F 19C-19cscp 0.049 - 1.09 0.22 1014 106 1102 227
Envelope loss/gain 12256 10289
12 a) infiltration 5588 576
b) Ventilation 0 0
13 Internal gains: Occupants @ 230 0 0
Appliances @ 1200 0 0
Less external load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 17844 10866
15 Duct loads 15% 17% 2622 1834
Total room load 20466 12699
Air required(cfm) J 656 680
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
�- wrvg"ts >Ft Right-Suit R sid ntial J8 5.8.15 RSR30950 2002-Nov-05 06:05:32
AM CAMy DocumentslWrightsott HVAC\TemplatelProjectl.rtt Calc=MJ8 Orientation=W pasow