Loading...
HomeMy WebLinkAbout124 Brookfield Street (9) ti` + DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT I CAPPRO 1540 SULLIVAN AVENUE Bldg.Permit# 15116 z 644-2511 ext. 230 Date Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job:_ 6f�04-z tic,c \4t .G $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANTG— APPLICANT ADDRESS c�'� �SJS�c1 APPLICANT PHONE# k O\t k 010 N S F OWNER ��� �►c��c � ��s— Co c-.�Sr� OWNER ADDRESSc�a� e�C� OWNER PHONE O S � ESTIMATED COST$ �9 Qj Do IS THIS A CONTRACT COST? (,�Yes No i CJ FEE ENCLOSED$ �f S_O TYPE OF JOB: ds0 C0 New Installation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: VAEATING ❑RESIDENTIAL &5VC 0 05MMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING 0 STEAM LOW PRESS LIMIT LBS. HIGH PRESSURE LIMIT LBS. ElHYDRONIC a-*_AARRM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE l 0 OF INSIDE '7 0 OF DIFFERENCE 'a c) °F TOTAL HEAT LOSS(BTUH)L$L/rF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) ZcrAz, , GROSS HEATING CAPACITY(INPUT—BTUH) `3OC-k-NET RATING(OUTPUT—BTUH) I E�O�pOb TYPE OF FUEL ❑ OIL—GPM OIL TANK LOCATION:❑INSIDE❑OUTSIDE CAPACITY UMAS—INPUT aj:!:jckq0LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE °F INSIDE-7-7°F DIFFERENCE aO OF TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING E UIPMENT(INCLUDIMAKE&MODEL NO.) ^4c_lS$C\LC c 6 c7 TONNAGE COOLING CAPACITY(BTUH) kOD VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT �+ p eA \DATE • HVAC LOAD ANALYSIS for Garrier RHVA RESIDENTIAL AND LIGHT COMMERCIAL.HVAC LOADS Prepared By: John Przybylski Hi Point Heating&Cooling 71 Edwin Road South Windsor,CT 06074 (860)291-0181 5/24IO2 x fi P t, .T ,y gig,, ;- y;, X.�a`4'vru. ,+, F m-m qz_ 'qr,r` i ,� z h�� a;, ?,'u., +>,; tin ,., 'vim'ice _" .,YFxsnea 4.n,t - F„ y: kw� �` f z.xk.'s ,,�; 'rk F,„HIMr,4,-v i,�s,, ,n.. T' ti,x Sri xu� +a� ` £r,.-wJ'�,..�.h =e,s.. - n? •vT �.� c' ty,tr�t%b \..,�v4„-a u <,.,.,r V -.^,,s s. ,.�- �*fv I;s 4 -, „��Sys, ^day_ „_;'.�' „gs,�."��a.,x;':w„dSn-V t �� a Project: Company: Hi Point H ating&Cooling Client: WILLOW BROOK GOLF COURSE Representative: John Przybylski Address: BROOKFIELD ST. Address: 71 Edwin Road City: SOUTH WINDSOR,CT. City: South Windsor,CT 06074 Phone: Phone: (860)291-0181 Fax: Fax: (860)291-0020 Proj ct Name: Reference City: Hartford,Connecticut Daily Temperature Range: Medium Latitud : 41 Degrees Elevation: 19 Feet Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference Wint r: 7 N/A N/A 72 N/A Summer: 88 73 50% 75 33 11,11115INEM Ill Total Building Supply CFM: 2,375 CFM per square foot: 0.884 Square feet of room area: 2,688 Square feet per ton: 361.784 Total heating required with outside air: 60,114 Btuh 60.114 MBH Total sensible gain: 52,221 Btuh 78 % Total latent gain: 14,964 Btuh 22 % Total cooling required with outside air: 67,185 Btuh 5.599 Tons(based on sensible+latent) 7.430 Tons(based on 77%sensible capacity) 1:111!111111m'':!iiiiiiiiiiiiiiiil������,ll Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. §r f .} 41 ww" , Component Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain 3B Window Double Pane Clear Glass TIM Frame 482 19,079 0 22,732 22,732 1 OD Door Wood Solid Core 105 31140 0 802 802 12H Wall R-19+ 112"Gypsum Board(R-0.5) 1,921 7,493 0 1,912 1,912 16F Ceiling R-26 Insulation 2,640 6,522 0 3,712 3,712 22D Slab on Grade 2"Edge Insulation(R-11) 224 3,058 0 0 0 Subtotals for structure: 5,372 39,292 0 29,158 29,158 Active People: 28 0 6,440 8,400 14,840 Inactive People: 20 0 3,000 5,000 8,000 Appliances: 0 0 41000 0 4,000 Lighting: 0 0 0 0 0 Ductwork: 0 10,019 0 8,703 8,703 Infiltration:Winter CFM: 151.2,Summer CFM:67.2 587 10,803 1,524 960 2,484 V ntilation:Winter CFM:0.0,Summer CFM:0.0 0 0 0 0 0 Sensibl Gain Total: 52,221 Temperature Swing Multiplier: X1.00 Building Load Totals: 60,114 14,964 52,221 67,185 Total Building Supply CFM: 2,375 CFM per square foot: 0.884 Square feet of room area: 2,688 Square feet per ton: 361.784 ONEEMENEW Total heating required with outside air: 60,114 Btuh 60.114 MBH Total sensible gain: 52,221 Btuh 78 % Total latent gain: 14,964 Btuh 22 % Total cooling required with outside air: 67,185 Btuh 5.599 Tons(based on sensible+latent) 7.430 Tons(based on 77%sensible capacity) MAN IN Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Fs �� z"� 4y A.iM - £ • i i U <,s. ar-,. ", `'"�a�"a.'Fs•;. ,S e '£";.`�'-�, r"`��r ,'"-0�' ar7'.E . t, , _ .� a, r "�`,..P - .� •�.s - NOW Htg Htg Run Run Cig Clg Clg Zone Clg Air Room Area Sens Nom Duct Duct Sens Lat Nom Adj Adj Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM —Zone 1- 1 Grille/bar 840 30,865 401 8-7 585 27,506 13,124 1,251 1.00 1,251 1,251 System 1 Totals 840 30,865 401 27,506 13,124 1,251 1,251 1,251 "Main Trunk Size: 16A 2 in. "Main Trunk velocity constraints were not met due to duct schedule limitations. Main Trunk Air Velocity= 1,005 Feet/Minute Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 3.386 68%/32% 27,506 13,124 40,630 Recommended: 4.755 77%/23% 43,937 13,124 57,061 2 111'1_ +.���r -1 4fi7'" "'F + •,f"'$...+`" ��r� , ."S.i.,t' vlT f„ r'' ^si'�pp ,"3`"-'` JIF'a'�4'',',, ;s�<fid : � �EM.�i Ell Htg Htg Run Run Clg Clg Cig Zone Cig Air Room Area Sens Nom Duct Duct Sens Lat Nom Adj Adj Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM —Zone 1- 2 Pro Shop 840 19,213 250 5-7 636 18,674 1,840 849 1.15 980 849 4 Kitchen 480 3,834 50 1-6 301 1,300 0 59 1.00 59 59 Zone 1 Subtotal 1320 23,047 300 19,974 1,840 909 1,039 909 —Zone 2- 3 Lays/lobby 528 6,202 81 2-6 549 4,741 0 216 1.25 270 216 Zone 2 Subtotal 528 6,202 81 4,741 0 216 270 216 System 2 Totals 1848 29,249 380 24,715 1,840 1,124 1,309 1,124 *Main Trunk Size: 16A 2 in. *Main Trunk velocity constraints were not met due to duct schedule limitations. Main Trunk Air Velocity=903 F et/Minut Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 2.213 930/o/7% 24,715 1,840 26,555 Recommended: 2.675 77%/23% 24,715 7,382 321097