Loading...
HomeMy WebLinkAbout114 Sally Drive DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# -If Aj J 644-2511 ext. 230 Date Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: 5�z2zK $0-$1,000=$15.00 FTenant eto. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof esignation Apt.No. APPLICANT � �4 f APPLICANT ADDRESS APPLICANT PHONE# �� a / — �o c)7 O W N St OWNER / C 1 �Ul •� q� OWNER ADDRESS K r� OWNER PHONE C ESTIMATED COST$ 2 c� U IS THIS A CONTRACT COST? Yes No f� FEE ENCLOSED$ 7 TYPE OF JOB: SOR.C) New Installation ,Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR HVAC PERMIT SContinued from reverse side) TYPE OF SYSTEM: TYPE OF B DING: UVATING SIDENTIAL A/C ❑ COMMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING ❑ STEAM LOW PRESS E LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC SMARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE f D OF INSIDE_ 0 F DIFFERENCE °F � TOTAL HEAT LOSS(BTUH) Z OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQ PMENT(INCLUDING MAKE&MODEL NO.) AaitZ GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) � TYPE OF IL-GPM OIL TANK LOCATION:❑INSIDE❑ OUTSIDE CAPACITY ❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP.OUTSIDE INSIDE °F DIFFERENCE�°F TOTAL HEAT GAIN(BTUH) kOF �(HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MO EL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. E STATE SIGNATURE OF APPLICANT DATE �" , O -03 RIGHT-J SHORT FORM Entire House f. L& L Mechanical 28 Pie H01 Rd,Goshen,CT 06756 Phone:(860)4914007 Fax(860)491-9125 e • ect Infohnation For: heidtmann south windso 14 sal we, ® - s r on Htg CIg Infiftratfon Outside db(OF) -10 85 Method Simplified Inside db(OF) 70 75 Construction quality Average Design TD(OF) 80 20 Fireplaces 0 Daily range - M Inside humidity(%) - 50 Moisture difference(gr/lb) - 47 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trad Trade Efficiency 80.0 AFUE Efficiency 0.0 EER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Low output baseboard 580 Btuh/ft Total cooling 0 Btuh Total low baseboard 36 ft Actual cooling fan 657 cfm High output baseboard 740 Btuh/ft Cooling air flow factor 0.053 cfmBtuh Total high baseboard 28 ft Space thermostat Load sensible heat ratio 87 % ROOM NAME Area Htg load Clg load Baseboard(ft) Clg AVF (ft� (Btuh) (Btuh) Low High (cfm) media room 418 21051 12287 36 28 657 Entire House 418 21051 12287 36 28 657 Ventilation air 0 0 Equip. @ 1.00 RSM 12287 Latent cooling 1788 TOTALS 418 21051 14075 36 28 657 C'c Z�r7j BoWhalic vakm have been manually overrWen Printout certified by ACCA to meet all requirements of Manual J 7th Ed. Wrightsoft RW-Suite Residential-5.0.48 RSR28903 2003-Apr-30 07:12:42 Projectl.mr Pag 1