Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1075 Pleasant Valley Road (6)
r DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR 7 BUILDING DEPARTMENT APPRO 2 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 r�9,,2 90 ate Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: 0—1 S {�L 6 q sE�nr T C t-c.Y $0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= $13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT � A r4"XX IsYS 17 "-s APPLICANT ADDRESS ..( 9 R O �Pt vim.., CDa121— 3 _ ",owTF..4 _ �— n 6I ca B- 3 APPLICANT PHONE# SZS — 3/ $7 ONN N S OWNER 4kaL01 m4a.0 u sg '4< OWNER ADDRESS 1 y 7 S PL"s*#-4 T VA!-t& ad A. OWNER PHONE cc) ?.A C ESTIMATED COST$ o c� U i IS THIS A CONTRACT COST? Yes 0 No CJ FEE ENCLOSED$ �� S TYPE OF JOB: SOR.CO M'New Installation 0 Alteration/Addition/Repair Revised 8/99 F APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OFF B�DING: IR zc- i ATING MIESIDENTIAL f� l ❑COMMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC ❑ WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH)JWF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) 'Q Rr,4.4 T �b � 0 3G /o S� ©�` v+�.►r a o.� GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) 97 TYPE OF FUFL IL—GPM OIL TANK LOCATION :S INSIDE❑ OUTSIDE CAPACITY ❑ GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE b_OF INSIDE _OF DIFFERENCE Z<s OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) S'C�3 c•J x onto 030 d� TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) 12M_ FRESH AIR INTAKE(CFM) -- (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK SYBJaeM THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 3 o Z G '77 ls�— ( CSl— CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE _ ( � .1 : Job Number: 1608 Temp Dif. (Heating): 70 F Date: 19•Feb-03 Job Name: SURBER Temp Dif. (Cooling): 25 F Air Change/Hour: 0.3 Quoted By: gerry U FACTORS 0.62 0.62 0.62 0.43 0.62 0.08 0.80 0.04 0.56 1.64 -- 0.04 Room Room Area Exp. Ceiling GLASS(Sq.Ft.) Floor Floor Exp. Std. Patio Misc. Net F/A Extra # Room Name Length Width Sq.Ft. Wall Height N E/W S Skylight SE/SW Area Edge Ceiling Doors Doors BTUH Wall CFM F/A CFM 1 LIVING 23 12 276 23 8 40 276 276 20 124 11.0 2 BEDROOM 1 17 12 204 27 8 28 204 _ 204 188 8.2 3 BATH 2 12 6 72 6 8 3 !72 72 45 2.9 4 KITCHEN 19 12 228 12 8 10 228 228 86 9.1 1 5 DINING 12 10 120 10 8 38 120 120 42 4.8 6 BATH 1 5 9 45 5 8 45 45 40 1.8 7 BEDROOM 3 12 13 156 25 8 14 156 156 186 6.2 8 BEDROOM 2 14 12 168 25 8 14 168 168 186 6.7 9 MUD ROOM 25 6 150 37 8 54 150 150 60 182 6.0 10 MUD ROOM 13 11 143 24 8 192 5.7 11 12 I 13 14 15 16 17 — 18 HEATING TOTALS: 32,083 BTUH LOSS x 1.10 HEAT UP FACTOR= 35,291 BTUH TOTAL 1,562 SQ.FT.TOTAL COOLING TOTALS: 22.421 BTUH GAIN x 1.15 COOL DOWN FACTOR= 25,784 BTUH TOTAL ENERGY SAVING PRODUCTS LTD. VENTILATION TOTALS: 4,745 HEATING BTUH u% COOLING BTUH 62 CFM F/A NEEDED HC 2 os PAGE 2 ,i ROOM BTUH ROOM BTUH # NAME HEATGAIN # NAME HEATLOSS 1 LIVING 4,830 1 LIVING 6,626 2 BEDROOM 1 3,398 2 1 BEDROOM 1 4,482 3 BATH 2 713 3 BATH 2 1,188 4 KITCHEN 2,167 4 KITCHEN 3,611 5 DINING 3,175 5 DINING 3,453 6 BATH 1 361 6 BATH 1 689 7 BEDROOM 3 2,239 7 BEDROOM 3 3,204 8 BEDROOM 2 2,309 8 BEDROOM 2 3,355 9 MUD ROOM 5,946 9 MUD ROOM 7,613 10 MUD ROOM 647 1:10: MUD ROOM 1,069