HomeMy WebLinkAbout121 Pheasant Way DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT
PERMIT#
Application is hereby: TOWN OF SOUTH WINDSOR
170
BUILDING DEPARTMENT l
APPROVt 1540 SULLIVAN AVENUE Bldg.Permit#
03 644-2511 ext. 230
D e Building Inspector
t
Application must be printed or typed
FEE SCHEDULE Location of Job:
00111/
$0-$1,000=$15.00 Street No. Street Lot No.
Over$1,000=
$15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT
APPLICANT ADDRESS H I Ave,
Wirvi-�Cc-, C= n ro 0 g-
APPLICANT PHONE#
1 (�
( OWN S OWNERtr_C ciarL
OWNER ADDRESS
—ID1 PV I )a V
�OWNER PHONE �9 y"
s
I C ESTIMATED COST$
i
IS THIS A CONTRACT COST? -ZYes No
FEE ENCLOSED$
TYPE 7B*
ew Installation
i
9
Alteration/Addition/Repair
9
r
r
Revised 4/01//2002
APPLICATION FOR HVAC PERMIT (Continued from reverse side)
TYPE OF SYSTEM: TYPE OF B LDING:
U/C
EATING SIDENTIAL
❑COMMERCIAL
❑VENTILATION ❑INDUSTRIAL
HEATING
❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
❑HYDRONIC ❑WARM AIR ❑UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
GROSS HEATING CAPACITY(INPUT BTUH) NET RATING(OUTPUT-BTUH)
TYPE OF FUEL
❑ OIL-GPM OIL TANK LOCATION:❑INSIDE❑ OUTSIDE CAPACITY
❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW
AIR CONDITIONING
DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
ESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
Ll TT x :�C
Ott "7 E :3 F�CAI CaOQ
TONNAGE_�,� COOLING CAPACITY(BTUH)
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
Z )�,0 a S
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT /1,& f 7 bJaila DATE
Page 1 4/1/2003
Resid ntial Heat Loss and He it Gain Calculation
In accordance with ACC A Manual J
R gistered To: Aiello Plumbing Heating and Air Conditioning
For: Clark,Jennifer S Bob
121 Pheasant Way
South Windsor, CT 06074
Design Conditions: Windsor Locks,Bradley Field
Indoor: Outdoor:
Summer temperature: 72 Summer temperature: 95
Muter temperature: 70 Winter temperature: -5
Relative humidity: 50 Summer grains of moisture: 93
Daily temperature rangeiMedium
Building Component Sensible Latent Total Total
Gain Gain Heat Gain H at Loss
(BTUH) (BTUH) (BTUH) (BTUH)
Whole House 29017 sq.ft. 28,556 39120 311,676 79,651
(2.5 tons)
_First Floor 17,421 2,306 19,727 ____57,115
Family Room 280 sq.ft. 3,311 _ 533 3,844 23,449
Breakfast Room 126 sq.ft. _ 3,810 _ _ 265 _4,075 __ - 5,901
Kitchen 140 sq.ft. 2,745 517 3,262 - 3,333
Bathroom_ -- 84 sq.ft.-- - -- 1,554 --- 303--_- 1,857- _ 6,274
Dining Room 156 sq.ft. _ 2,410 246---- _ 2,656 _6,273
Hall 120 sq.ft. 1,229 196 1,425 4,924
Living Room-- -- 204 sq.ft. --- _2,362-----_ - 246 -- 2,608 - - 6,961
Second Floor 11,135 814 11,949 22,537
Master Bedroom__ 208 sq.ft. _ 3,059 246 3,305 -5,993
Master Closet 48 sq.ft. _ 411 _ 0 411 1,044
Master Bathroom 112 sq.ft. 926 _ _ 38 _ __964 _ 1,849
Bathroom --56 sq.ft. -- - 633
Hall _39 sq.ft. 107 _ _ 0 107
Bedroom 120 sq.ft. 1,813 164 1,977 _- _ 4,068
Bedroom (2)--- - 168 sq.ft. --- - 29761 - 246 _ 3,007 5,634
Bedroom (3) --- 120 sq.ft. 1,265 _ _82 1,347 _-_ 2,248
Hall (2) 36 sq.ft. 160 - -_- 160 - - -- 342-
Whole House 29017 sq.ft. 289556 3,120 31,676 79,651
(2.5 tons)
HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101
Load calculations are estimates only,actual bads ma r vary due to weadw and construction►diRerenoes.
f
r
• t
Page 1 4/1/2003
Duct Sizing Rep rt
Registered To: Aiello Plumbing Heating and Air Conditioning
For: Clark, Jennifer&Bob
121 Pheasant Way
South Windsor, CT 06074
Rooms Serviced Supply Material CFM FPM Duct Size
or Return
Family Room-Outlet A Supply Flex 147 600 7"Round
Family Room-Outlet B Supply Flex 147 600 7" Round
Breakfast Room Supply Flex 133 600 6"Round
Kitchen Supply Flex 96 600 5" Round
Bathroom Supply Flex 79 600 5"Round
Dining Room Supply Flex 84 600 5" Round
Hall Supply Flex 62 600 4" Round
Living Room Supply Flex 87 600 5"Round
Master Bedroom Supply Flex 107 600 6"Round
Master Bedroom Supply Flex 107 600 6"Round
Master Closet Supply Flex 14 600 3" Round
Master Bathroom Supply Flex 32 600 3"Round
Bathroom Supply Flex 22 600 3"Round
Hall Supply Flex 4 600 3" Round
Bedroom Supply Flex 63 600 4"Round
Bedroom (2) Supply Flex 97 600 5" Round
Bedroom (3) Supply Flex 44 600 4" Round
Hall (2) Supply Flex 6 600 3"Round
Family Room-Outlet A Supply Rigid 1224 900 16" Round
Family Room-Outlet B
Breakfast Room
Kitchen