Loading...
HomeMy WebLinkAbout150 Laurel Street (2) DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WIl�TDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# 04, 644-2511 ext. 230 Date Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. _ o APPLICANT l A-YYI D 13 A-�b( { APPLICANT ADDRESS T3 J NS AUL f i N 70) O G i< I 9 APPLICANT PHONE# 9r,O G(9 7-&-Z,;r6 S-7 3 - 9 1 Z— i O N Se OWNER YYI e A SS E U, PR . 4� OWNER ADDRESS g s vts-, A w I N�SO,r� c�� O Co 0 7`i- 3 OWNER PHONE 8 6 C) (s 4 4 - ESTIMATED COST$ 0 CT-U Dd IS THIS A CONTRACT COST? Yes No - FEE ENCLOSED$ 30,00 TYPE OF JOB: SpR.CO New Installation Alteration/Addition/Rep air tad 1+ i Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: ❑HEATING ❑RESIDENTIAL %,AC ❑COMMERCIAL ❑l VENTILATION D INDUSTRIAL HEATING ❑STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC ❑WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE °F TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL ❑ OIL--GPM OIL TANK LOCATION:❑INSIDE❑ OUTSIDE CAPACITY ❑GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE 100 OF INSIDE 7,5— OF DIFFERENCE �,S— OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL C LING EQUIPMENT(INCLUDING MAKE&MODEL NO.) EZ-V1N TO - — ili S3-13R- 030)(�A coJ2) E4),S)N6 UNOf K EW I�J A7V(—Z- Q 3 13 M --03 co K-4 JP )re, I+I�f-J DLEFK . TONNAGE�o S COOLING CAPACITY(BTUH) 3 0 U v v VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 59- 0 [ t Cc CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT l C/ DATE /Q , 6 -0 2 J Q B NAME: S G DATE /C7 �- a z ADDRESS: ��c. f)fo07 OUTDOOR TEMP: loo INDOOR TEMP: TEMP DIFFERENCE: Zw5- SENSIBLE LOAD CALCULATIONS ' GLASS SINGLE DOUBLE TRIPLE NO SHADE • DESIGN TEMPERATURE DIFFERENCE COMPASS GLASS AREA 10 15 20 28 30 3S 10 1520 2530 35 10 15 20 23 30 35 BTUH POINT SD. FEET HEAT GAINHEAT TRANSFER MULTIPLIER N 25 29 13 37 41 46120 r2 24 26 21 33 15 16 18 19 20 21 Z.O NE& NW 65 60 65 70 75 80 50 52 54 56 68 60 37 38 40 41 42 44 E&W 80 83 90 95 100 105 70 72 74 76 78 80 55 56 58 69 60 82 SE& sw 70 74 78 82 86 90 60 62 64 66 68 70 47 49 51 52 53 64 S Z 40 44 48 52 56 60 36 37 39 41 43 45 1% 27 29 31 32 33 Z GLASS SINGLE DOUBLE TRIPLE INSIDE SHADE DESIGN TEMPERATURE DIFFERENCE COMPASS GLASS AREA 10 15 20 25 30 35 10 15 20 25 30 33 10 15 20 2930 38 . BTUH POINT 80. FEET HEAT TRANSFER MULTIPLIER HEAT GAIN N 15 19 23 27 31 35 15 17 19 21 23 25 10 12 14 16 17 19 NE& NW 35 39 43 47 51 SS 30 32 34 35 38 40 22 24 26 28 30 31 E'&W 50 54 58 62 66 70 45 47 49 51 53 55 35 36 38 40 42 44 SE& SW 40 44 48 52 58 60 35 37 39 41 43 45 129 30 32 34 38 38 S 25 29 33 37 41 45120 22 24 26 28 30 1 16 18 20 22 24 26 :DW DESIGN TEMPERATURE DIFFERENCEDOORS SaEETf - 10 15 20 30 35 HEAT GAIN HEAT TRANSFER ULTiPLIER SOLI00 6.3 8.6 10.9 13.2 14.4 15.5 SOLID WOOD" 2 4.2 5.7 7.3 6.8 9.6 10.4 METAL URETHANE 2.8 3.5 4.5 5.4 5.9 6.4 METAL URETHANE " 2.2 3.0 3.8 4.8 5.0 5.4 '• Weatherstrl ed or Storm RUNNING FEET Zito- CEILING HEIGHT x CENTRAL AIR SUPPLY WALLS GROSS WALL Z. 118 LEDYARD STAEET WINDOWS& DOOR AREAS �L_ HARTFORD, CT 06114 NET WALL AREA 1 3 (860)296-4240* 1.800-394-2473 DESIGN TEMPERATURE DIFFERENCE BTUH FRAME WALL SQUAREFEET 10 1g 20 25 30 35 HEAT GAIN HEAT TRANSFER MULTIPLIER NO INSULATION 3.7 5.0 6.4 7.8 8.5 9.1 R•11, 3"INSULATION 1.2 1.7 2.1 2.6 2.8 3.0 R-13, 3-1/2"INSULATION 1.1 1.5 1.9 2.3 2.5 2.7 R-13 + 1"POLYSTYRENE 0.8 1.1 1.4 1.7 1.8 2.0 R-19 + 1/2"POLYSTYRENE 0.7 1.0 1.3 1.6 1.7 1.8 DESIGN TEMPERATURE DIFFERENCE MASONRY WALL SQUARE 40 15 20 25 30 35 HEAT ABOVE GRADE FEET HEAT TRANSFER MULTIPLIER HEAT GAIN NO INSULATION 3.2 5.8 8.3 10.9 12.2 13.4 R-5, 1"INSULATION 0.9 1.6 2.3 3.1 3.5 3.8 9-11,3"INSULATION 0.5 0.9 1.3 1.6 1.8 2.0 R•19, 6"INSULATION 0.3 0.5 0.8 1.0 1.2 13 SENSIBLE HEAT GAIN SUBTOTAL 70 . Sensible Heat Gain Subi fioiri'P 1 SQUARE , DEMON TEMPERATURE OIFFERENCEt :,� °STUN ! CEILING FEET 1f3 t8 .20 . 28 rk1.;�+t*30 .... :: ;,. t,.,; HEAT TRANSFER MULTIPUER HEAT OAlN E-19, n 14.9 17.0 19.2 1.4. sulation 2.8 3.2 t 3.7 4.1 4.3 4.5 sulation 1.8 7.1 2.3 2.0 ' "8 2.9 nsulation O 1.1 1.3 1.5 8 f.7 TOnsulation 0.9 1.0 1.1 1.3 2. 1.3 1.4 1-1 FLOOR OVER SQUARE DESIGN TEMPERATURE DIFFERENCE STU" UNCONDITIONED SPACE FEET .10 15 20 25 30 36 HEAT GAIN HEAT TRANSFER UL-TYPLIER No Insulation 1.9 3.9 5.8 K 8.7 9.6 CARPET FLOOR-NO INSULATION Z.C� 1.3 2.6 3.8 5.1 5.7 8.3 Co Z R•11,3" INSULATION 0.4 0.8 1.3 1.7 1.9 2.1 R-19.6" INSULATION 0.3 0.5 0.8 1.1 t.2 1.3 R-30, 10"INSULATION 0.2 0.4 0.6 0.7 0.8 0.9 F L 0 0 R SiQ FT. ,.,x� CEILING HEIGHT -41'rZv CUBIC FT FFILT ENTRATIONf 0,40 x Sew CU61C FT + 60 �0CFM VENTILATION iN MECHANICAL VENTILATION CFM FRESH AIR INTAKE DESIGN TEMPERATURE DIFFERENCE 8TUH CFM 10 1s 20 25 30 35 HEAT TRANSFER MULTIPLIER HEAT GAIN ION 11.0 18.5 22.0 27.0 32.0 38.0 Z o MECHANICAL VENTILATION _ 11.0 16.5 22.0 27.0 32.0 38.4 EKilchen HEAT GAfN BTUH HEAT GAIN Peo le 5 x 300 00 owance 1,200 SENSIBLE HEAT GAIN SUBTOTAL 171(o Z DUCT GAIN BTUH 14EAT GAfN R-4, 1" Flexible Blanket Insulation: ADD 15% 1.15) + R•7, 2" Flexible Blanket Insulation. ADD 10% I.10I &o TOTAL SENSIBLE HEAT GAIN H Sr LATENT LOAD CALCULATIONS Conditions Outdoor Wet Bulb Indoor Wet Bulb Grains Wet 60 62.5 So Medium 75 625 35 Medium Dry 70 62.5 20 Cry 1 65 1 62.5 a Based on 750F Indoor Dry Bulb at 50% Rif. LATENT LOAD-INFILTRATION s r�06? 0 68 x -1: Grains x t*O Infilt?ation CFM LATENT LOAD-VENTILATION 0.68 x -Grains x Ventilation CFM LATENT LOAD-PEOPLE0 Number of People x 230 lV TOTAL LATENT HEAT GAIN TOTAL SENSIBLE AND LATENT HEAT GAIN Z. Ch LL NOTE. All .Beat Transfer Multipliers from ACCA Marual 'J" Sixth Edition and for a medium outdoor daily temperature range. CL 841-L7 002145 L,tno U.S.A.