Loading...
HomeMy WebLinkAbout122 Dart Hill Road (2) DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT T# MI Application is hereby: TOWN OF SOUTH WINDSOR //PER BUILDING DEPARTMENT APPROVE 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Date Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: a-c--� L)a F4 il 1 1 Rd $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT A�P i K n R r l A C APPLICANT ADDRESS C-k OHO q d APPLICANT PHONE# O W N St OWNER ie. nan OWNER ADDRESS �+A R C-T 7'Y OWNER PHONE (0t — Z00 D�, 0 C ESTIMATED COST$ �CJ � IS THIS A CONTRACT COST? Yes No FEE ENCLOSED$ 1� TYPE OF JOB: �SOR.Co New Installation 7X7 Alteration/Addition/Repair f { Revised 410IH2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: ❑HEATINGtESIDENTIAL C• ❑COMMERCIAL /❑3 VENTILATION ❑INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC ❑WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL ❑ OIL—GPM OIL TANK LOCATION :❑INSIDE❑ OUTSIDE CAPACITY ❑GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) cDT TB 1 C:fin A I nnl A A i r Hacrl�Pc ' Tw E- a n r 1 L/o� V TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) Q FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK i r P FTC W tk C L)Cf W 0rj<- �e�eC+ v n G 0 i r- C fore THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. n�6 2-5c-:-;� f5 < C T CONTRACTORS LICENSE NO. TYPE STATE �-- , DATE ��-� SIGNATURE OF APPLICANT Page 1 Residential Heat Loss and Heat Gain Calculation 5/28/2003 In accordance with ACCA Manual J Registered To: Aiello Plumbing Heating and Air Conditioning For: Mancuso 122 Dart Hill Rd South Windsor, CT. 06074 Total CFM: 1,000 Room Cooling CFM Heating CFM Both First Floor 1,000 1,000 1,000 Kitchen -- - -- - 328 330 330 - - -------- - - Bathroom - --- - - -- ---- - --- -- ----- 9 17 _ 17 -- ------------ -- - -------- --- aster Bath -- -- - -- - ---- - - ------ 33 42- - 42 Master Bedroom _ - 98 117 117 Hall 7 18 18 Dining Room 134 113 134 Foyer 24 50 50 Living Room 167 137 167 Bedroom 87 73 87 Bedroom (2) 113 - 104 113 HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only,actual loads may vary due to weather and construction differences. Page 1 5/28/2003 Residential Heat Loss and Heat Gain Calculation In accordance with ACCA Manual J Registered To: Aiello Plumbing Heating and Air Conditioning For: Mancuso 122 Dart Hill Rd South Windsor, CT. 06074 Design Conditions: Windsor Locks,Bradley Field Indoor: Outdoor: Summer temperature: 72 Summer temperature: 95 Winter temperature: 70 Winter temperature: -6 Relative humidity: 50 Summer grains of moisture: 93 Daily temperature rangeMedium Building Component Sensible Latent Total Total' Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Whole House 1,142.4 sq.ft. 22,468 2,726 25,194 55,058 (2 tons) First Floor 2.2,467 2,724 25,191 55,060 Kitchen 320 sq.ft. 7,361 1,631 _8,992 1.8,163 ---- --- - - - - - - -- - - - ---------- - -- - - ----------- - - -- - ----- ----- -- - - Bathroom 30 sq.ft. 204 _ 0 204 911 --------------- - - -- ----------- - - - - - - - ----- - --- - - - - --- - Master Bath 60 sq.ft. 743 _ _ 42 785 2,286 - - - - - - - - -- -- - - -- - - ---- - - - --- Master Bedroom 161 sq.ft. 2,213 139 2,352 6,437 Hall 54 sq.ft. 149 0 149 987 Dining Room - 110 sq.ft.------ 3,010 209 3,219 6,207 Foyer 45 sq.ft.- - - -- 535----- ----1- -- --46 681---- ,745 - -- -- - - - ------- -------- ---------- -- - ----- ----- ----- ---- -- --- - --- - - -2- - Living Room_ 150 sq.ft_ 3,761 279 4,040 7,552 --------- -- - - - ---- -- - - --------- -- - --- - --- --------- --- - - Bedroom 80 sq.ft. 1,944 139 2,083 4,019 Bedroom (2) 132 sq.ft. 2,547 139 2,686 5,753 Whole House 1,142.4 sq.ft. 22,468 2,726 25,194 55,058 (2tons) HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only,actual loads may vary due to weather and construction differences.