Loading...
HomeMy WebLinkAbout1739 Ellington Road (21) STATE OF CONNECTICUT DEPARTMENT OF PUBLIC SAFETY f DIVISION OF FIRE,EMERGENCY AND BUILDING SERVICES September 11, 2002 Otis Elevator Company 242 Pitkin Street East Hartford, CT 06108 Re: Stop & Shop#699 1"I M Ellington Road South Windsor, CT 06074 To All Contractors: We are returning your approved blueprint No. 466626 for one Passenger Elevator to be located at the above address. These drawings have been reviewed, found to be in compliance with requirements, and are hereby approved for construction. Please note that no deviations from the approved plans are allowed without prior approval from this office. Scheduling new acceptance inspections should be made at least 5 working days prior to the required date. Very truly yours, Nancy C. DiMitruck, State Elevator Inspections Supervisor Approved by: LP/sf 4�� /4090 Enclosure cc: Building Official—South Windsor, CT 1111 Country Club Road P.O.Box 2794 Middletown,CT 06457-9294 An Equal Opportunity Employer STATE OF CONNECTICUT - DEPARTMENT OF PUBLIC SAFETY BUREAU OF ELEVATORS COMMON REASONS FOR NON-ACCEPTANCE OF NEW ELEVATOR INSTALLATIONS: MACHINE ROOM Required door lock and closer. Circuit breaker or disconnect must be lockable and sealable. Disconnect must be interlocked in both positions. Fire rating of machine room enclosure must be in accordance with CT Building Code. Use of machine room as a thoroughfare. Presence of access panels in ceilings or walls. (A suspended ceiling would be considered an access panel). Improperly guarded or unguarded lighting. Machine room ventilation as required by ANSI A17.1. HOISTWAY Hoistway fire rating and venting must be in accordance with CT Building Code. Voids and gaps in hoistway walls or door bucks. Improperly fastened rails and brackets. PITS Water in pit- pit must be kept in clean, dry condition. Pit circuit must have GFI protection. Pit lights must be guarded. Sumps and sump holes must have securely fastened covers. GENERAL When sprinklers are installed in hoistway and machine room, a means of automatically disconnecting main line power before or upon application of water must be provided. Heat detectors when used shall be within 24 inches of sprinkler head. Above system cannot be installed where there is no sprinkler head. Elevator cab must have means of communication to a 24 hour manned station or service. THIS LIST DOES NOT COVER ALL POSSIBLE PROBLEMS THAT MAY BE ENCOUNTERED, IT MERELY REFLECTS SOME OF THE COMMON ISSUES.