Loading...
HomeMy WebLinkAbout19 Cody Circle (2) DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT APPROVE 1540 SULLIVAN AVENUE Bldg.Permit# -A 644-2511 ext. 230 Date Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: e re e $0-$1,000=$W,80/-5- Street No. Street Lot No. Over$1,000= per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT P APPLICANT ADDRESS 76/ 0 r- �'d------ Z6,; a 5-or- r,-7--' e 6 ef"7 APPLICANT PHONE# W N S OWNER //7,4`7 /dl/- Y �Q c� Ns� ' q� OWNER ADDRESS 167ore7 N. E., OWNER PHONE i p C ESTIMATED COST$ U IS THIS A CONTRACT COST? &Yes 0 No f � Q ,• �C� FEE ENCLOSED$ (n Ca F O�� TYPE OF JOB: OR•C New Installation Iteration/Addition/Repair Revised 8/99 3 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: 4 ' ❑HEATING 21-RESIDENTIAL ! 7,/ G1�, M.A/C ❑COMMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC ❑WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT BTUH) TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION:❑INSIDE❑ OUTSIDE CAPACITY ❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP.OUTSIDE ��°F INSIDE��`F DIFFERENCE Z"O OF TOTAL HEAT GAIN(BTUH)V5,2- (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) 7Aa o / Z. /,� TONNAGE f COOLING CAPACITY(BTUH)_Z; �g� VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. jej y l CONTRACTORS LICENSE NO. STATE SIGNATURE OF APPLICANT - �i�- DA L 3 Z i BEAULIEU HVAC LOAD ANALYSIS for RHVACCOMbtERCU11,WAC LOAM Prepared By: Stephen P.Smith Advanced Heating&AC Inc. 701 Nutmeg Rd.North So.Windsor,Ct.08074 (860)282-0205 0SQ3J02 Project: Beaulieu Company: Advanced Heating&AC Inc. Client: Matt and Cindy Beaulieu Representative: Stephen P. Smith Addr ss: 19 Cody Circle Address: 701 Nutmeg Rd. North City: So. Windsor, Ct. 06074 City: So. Windsor, Ct. 06074 Phone: Phone: (860)282-0205 Fax: Fax: (860)528-2949 Comment: Project Nam Beaulieu Reference City: Hartford, Connecticut Daily Temperature Range: Medium Latitude: 41 Degrees El vation: 19 Feet Elevation Sensible Adj. Factor 1.000 Elevation Total Adj. Factor 1.000 Outdoor Outdoor Indoor Indoor Grains Bulb We Bulb Rel.Hum. Dry Bulb Difference Winter: 7 N/A N/A 72 N/A Summer: 95 73 50% 75 22 Total Building Supply CFM: 313 CFM per square foot: 0.92 Square feet of room area: 340 Square feet per ton: 456.761 Total heating required with outside air: 13,516 Btuh 13.516 MBH Total sensibl gain: 6,878 Btuh 94 % Total latent gain: 407 Btuh 6 % Total cooling required with outside air: 7,285 Btuh 0.607 Tons(based on sensible+latent) 0.744 Tons(based on 77%sensible capacity) Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Tuesday,May 21,2002 Component Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain 3C Window Double Pane Clear Glass Metal Frame 74 3,488 0 3,878 3,878 12H Wall R-19+ 1/2"Gypsum Board(R-0.5) 538 2,098 0 762 762 16G Ceiling R-30 Insulation 340 729 0 494 494 19D Floor Over Basement/Encl Crawl Hardwood+ R-19 340 575 0 0 0 Subtotals for structure: 1,292 6,890 0 5,134 5,134 Active People: 0 0 0 0 0 Inactiv People: 0 0 0 0 0 Appliances: 0 0 0 0 0 Lighting: 0 0 0 Ductwork: 0 2,253 0 1,146 1,146 Infiltration: Winter CFM:61.2, Summer CFM: 27.2 74 4,373 407 598 1,005 Ventilation: Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0 Sensible Gain Total: 6,878 Temperature Swing Multiplier: X1.00 Building Load Totals: 13,516 407 6,878 7,285 Total Building Supply CFM: 313 CFM per square foot: 0.92 Square feet of room area: 340 Square feet per ton: 456.761 Total h ating required with outside air: 13,516 Btuh 13.516 MBH Total sensible gain: 6,878 Btuh 94 % Total latent gain: 407 Btuh 6 % Total cooling required with outside air: 7,285 Btuh 0.607 Tons(based on sensible+latent) 0.744 Tons(based on 77%sensible capacity) Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. B sur to select a unit that meets both sensible and latent loads. Tuesday,May 21,2002 s Room Length: 20.0 Feet System Number: 1 Room Width: 17.0 Feet Zone Number 1 Area: 340.0 Square Feet Supply Air: 313 CFM C iling H ight: 12.0 Feet Required Vent.Air: 0 CFM Volume: 4,080.0 Cubic Feet Actual Winter Ventilation Air. 0 CFM Number of R gisters: 3 %of Supply: 0 % Runout Air 104 CFM Actual Summer Ventilation Air 0 CFM Runout Duct Size: 6 Inches %of Supply: 0 % Runout Air Velocity: 531 Feet/Minute Actual Winter Infiltration Air: 61 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air 27 CFM allot. Actual Loss: 0.181 In.wg/100 Ft. Item Area -U- Htg Sen. Clg Latent Sen. D scription Quantity Value HTM Loss HTM Gain Gain W-WALL-121-1 20 X 9 168 0.060 3.9 655 1.4 0 238 E-WALL-121-1 20 X 9 158 0.060 3.9 616 1.4 0 224 S-WALL-121-1 17 X 12 170 0.060 3.9 663 1.4 0 241 N-WALL-12H 4 X 12 42 0.060 3.9 164 1.4 0 59 W-GLAS-3C 2-P 0-0 S-1 0%S 12 0.725 47.1 566 72.0 0 864 E-GLAS-3C 2-P 0-0 S-1 0%S 22 0.725 47.1 1,037 72.0 0 1,584 S-GLAS-3C 2-P 0-0 S-1 0%S 34 0.725 47.1 1,602 38.0 0 1,292 N-GLAS-3C 2-P 0-0 S-1 100%S 6 0.725 47.1 283 23.0 0 138 UP-CEIL-16G DARK 20 X 17 340 0.033 2.1 729 1.5 0 494 FLOOR-19D 17 X 20 340 0.052 1.7 575 0.0 0 0 Subtotals for structure: 1,292 6890 0 5134 Infiltration: Winter. 61.2, Summer: 27.2: 74 59.095 4,373 8.081 407 598 Ductwork: 0.200 2253 0.200 0 1146 Active People: 230 lat/per, 300 sen/per 0 0 0 I nactiv People: 150 lat/per, 250 sen/per 0 0 0 Appliances: 0 0 Lighting: 0 S nsibl Gain Total: 6878 Temperature Swing Multiplier X1 00 Room Totals: 13,516 407 6,878 Tuesday,May 21,2002 i i Htg Htg Run Run Clg Cig Clg Zone Clg Air Room Area Sens Nom Duct Duct Sens Lat Nom Adj Adj Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM_ --Zone 1- 1 New Family 340 13,516 176 3-6 531 6,878 407 313 1.17 365 313 Room System 1 Totals 340 13,516 176 6,878 407 313 365 313 Main Trunk Size: W in. 1 i I f Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 0.607 94%/6% 6,878 407 7,285 Recommended: 0.744 77%/23% 6,878 2,054 8,932 i i I i i I I � I i li i I I II I I I I I I, i Tuesday,May 21,2002