Loading...
HomeMy WebLinkAbout188 Candlewood Drive DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERNIIT# Application is hereby: ��S'�j 0 BUILDING DEPARTMENT �APPRO 1540 SULLIVAN AVENUE Bldg. Permit# Z jx e. 644-2511 ext. 230 ate Building Inspector i Application must be printed or typed FEE SCHEDULE Location of Job: -AIQ�-Jrn(nd J)C--� V(2� $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. 3 i APPLICANTCa2aJjUyl 1 APPLICANT ADDRESS lA I J5 0 yi AUC, CT 06025 APPLICANT PHONE h Cfl 902;— -1`31L r i O N S OWNER a w S I1 n S Yl q� OWNER ADDRESS m ,Q48 VC VQ- OWNER PHONE N 6)�R— 2.4-4 `,t/ /o 6—SS-6Z O C ESTIMATED COST$ 3700—' U IS THIS A CONTRACT COST? :/Yes No j� FEE ENCLOSED$ �O TYPE OF JOB: SOR New Installation �llteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: .RESIDENTIAL 14 A/C ❑COMMERCIAL ❑VENTILATION ❑INDUSTRIAL HEATING ❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC 2!WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) Tnw/e- GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT BTUH) TYPE OF FUEL ❑ OIL-GPM OIL TANK LOCATION:❑INSIDE❑ OUTSIDE CAPACITY ❑ GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 30303Z CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT Z�d DATE 8 �.. Page 1 6/24/2002 Residential H at Loss and Heat Gain Calculation In accordance with ACCA Manual J Registered To: Aiello Plumbing Heating and Air Conditioning For: Jon Dashosh 188 Candlewood Dr. S Windsor, Ct 06074 Design Conditions: Windsor Locks,Bradley Field Indoor: Outdoor: Summer temperature: 72 Summer temperature: 90 Winter temperature: 70 Winter temperature: 4 Relative humidity: 50 Summer grains of moisture: 93 Daily temperature rangeMedium Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Whol House 189065 21031 209096 239968 ( 1.5 tons) First Floor _ _ __ 18,065 2,031 20,096 23,968 -- ---- ---- -- All.-Rooms---- 18,065 2,031 20,096 23,968 Whol House 189065 29031 20,096 239968 ( 1.5 tons) HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only,actual loads may vary due to weather and construction differences. July 9, 2002 TO: Melanie Cruccitti, Director of Finance t FROM: John Collins, Chief Building Official RE: Fee Refund I have attached a fee refund request. Our past policy has been to refund one- half of the fee paid in such cases.