HomeMy WebLinkAbout120 Bridlewood Road (7) �+ r
DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT
TOWN OF SOUTH WINDSOR PERMIT#
Application is hereby:
BUILDING DEPARTMENT
APP 1540 SULLIVAN AVENUE Bldg.Permit#
L4a644-2511 ext. 230 Building Inspector
Application must be printed or typed
Location of/Job:
FEE SCHED�� I I a o 06(-id e kzad D Le I
$0-$1,000=$13.00 Street No. Street Lot No.
Over$1,000=
$13.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT *Z&," =-4 e--
APPLICANT ADDRESS ?O rq�z
APPLICANT PHONE#
W N S OWNER Alf'ft-- /J r
O F
-4� OWNER ADDRESS O act
r
F N
yam; t#
e
OWNER PHONE
ESTIMATED COST$
IS THIS A CONTRACT COST? &.Yes O No
ICJ FEE ENCLOSED$
TYPE OF JOB:
OR-Co
x6ew Installation
0 Alteration/Addition/Repair Revised 8/99
a
APPLICATION FOR HVAC PERMIT (Continued from reverse side
TYPE OF SYSTEM: TYPE OF BUILDING:
All-HEATING ALRESIDENTIAL
�c/C ❑COMMERCIAL
❑ VENTILATION ❑INDUSTRIAL
HEATING
❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
❑HYDRONIC -C�WARM AIR ❑UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE 652 °F INSIDE 7 5- °F DIFFERENCE 7 5 ' OF
TOTAL HEAT LOSS(BTUH)?,tt�F(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
GROSS HEATING CAPACITY(INPUT—BTUH)� ro&P NET RATING(OUTPUT—BTUH) ��
TYPE OF FUEL
❑OIL—GPM OIL TANK LOCATION :❑INSIDE❑ OUTSIDE CAPACITY
Ld GAS—INPUT/ LPG TANK CAPACITY ELECTRIC—KW
AIR CONDITIONING
DESIGN TEMP.OUTSIDE�°F INSIDE 75°F DIFFERENCE Z� °F
TOTAL HEAT GAIN(BTUH)#7,711-- (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
TONNAGE C COOLING CAPACITY(BTUH) ` et
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK ',/u c
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
CONTRACTORS LICENSE NO. E STATE
SIGNATURE OF APPLICANT
�'` DATE 6 ler Z
BRIDLEWOOD RD, SO. WINDSOR
HVAC LOAD ANALYSIS
for
Lt
itejo%vare
RHVACft° nxm°uw
C HVAC LOADS
Prepared By:
Stephen P.Smith
Advanced Heating&AC Inc.
701 Nutmeg Rd.North
So.Windsor,Ct.00074
(860)282-0205
06-26-02
Flamm
Project: Bridlewood Rd, So. Windsor Company: Advanced Heating&AC Inc.
Client: MrA Mrs. Harold Thomas Representative: Stephen P. Smith
Address: Address: 701 Nutmeg Rd. North
City. City: So. Windsor, Ct. 06074
Phone: 568-7760 Phone: (860)282-0205
Fax: 568-7760 Fax: (860)528-2949
Comment:
Project Name: Bridlewood Rd, So. Windsor
Reference City: Hartford, Connecticut
Daily Temperature Range: Medium
Latitude: 41 Degrees
El vation: 19 Feet
Elevation Sensible Adj. Factor: 1.000
Elevation Total Adj. Factor: 1.000
Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference
Winter. 7 N/A N/A 72 N/A
Summ r: 88 73 50% 75 33
Total Building Supply CFM: 1497 CFM per square foot: 0.641
Square feet of room area: 2,337 Square feet per ton: 656.13
Total heating required with outside air: 92,621 Btuh 92,621 MBH
Total sensible gain: 32,911 Btuh 90 %
Total latent gain: 3,761 Btuh 10 %
Total cooling required with outside air: 36,672 Btuh 3.056 Tons(based on sensible+ latent)
3.562 Tons(based on 77%sensible capacity)
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
Tuesday,June 25,2002
Component Area Sen. Lat. Sen. Total
Description Quan Loss Gain Gain Gain
3C Window Double Pane Clear Glass Metal Frame 445 20,971 0 17,633 17,633
11A Door Metal Fiberglass Core 20 767 0 196 196
12H Wall R-19+ 1/2"Gypsum Board(R-0.5) 2,629 12,334 0 3,148 3,148
16D C iling R-19 Insulation 1,823 6,280 0 3,574 3,574
19A Floor Over Basement/Encl Crawl Hardwood No Insulation 598 6,064 0 0 0
201 Floor Over Open Crawl Carpet+ R-19 1,315 4,103 0 506 506
Subtotals for structure: 6,830 50,519 0 25,057 25,057
eve People: 0 0 0 0 0
Inacive People: 0 0 0 0 0
Appliances: 0 0 0 0 0
Lighting: 0 0 0
Ductwork: 0 15,437 0 5,485 5,485
Infiltration: Winter CFM: 373.2, Summer CFM: 165.9 465 26,665 3,761 2,369 6,130
V ntilation: Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0
Sensible Gain Total: 32,911
Temperature Swing Multiplier: X1 00
Building Load Totals: 92,621 3,761 32,911 36,672
Total Building Supply CFM: 1497 CFM per square foot: 0.641
Square feet of room area: 2,337 Square feet per ton: 656.13
Total heating required with outside air: 92,621 Btuh 92.621 MBH
Total sensible gain: 32,911 Btuh 90 %
Total latent gain: 3,761 Btuh 10 %
Total cooling required with outside air: 36,672 Btuh 3.056 Tons(based on sensible+latent)
3.562 Tons(based on 77%sensible capacity)
Calculations are based on 7th edition of ACCA Manual J.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads.
Tuesday,June 25,2002
Htg Htg Run Run Clg Clg Clg Zone Clg Air
Room Area Sens Nom Duct Duct Sens Lat Nom Adj Adj Sys
No Name SF Btuh CFM Size Vel Btuh Btuh CFM Fact CFM CFM
-Zone 1-
1 Study 192 5,719 74 1-4 684 1,312 267 60 1.00 60 60
2 Foyer 64 1,392 18 1-4 210 403 24 18 1.00 18 18
3 Dining 144 10,349 134 2-4 691 2,650 534 121 1.00 121 121
4 Kitchen 144 3,313 43 1-5 549 1,645 97 75 1.25 94 75
5 Breakfast 132 11,784 153 3-5 644 5,788 655 263 1.35 355 263
6 Great 306 16,679 217 3-6 461 5,975 728 272 1.18 320 272
7 Master Suite 598 20,608 268 3-5 600 5,394 599 245 1.19 293 245
Zone 1 Subtotal 1580 69,844 908 23,167 2,904 1,054 1,261 1,054
-Zone 2-
8 Bed 3 168 5,152 67 2-5 494 2,960 202 135 1.00 135 135
9 2nd FI. Lav 102 1,316 17 1-4 270 518 24 24 1.00 24 24
10 Bed 4 154 6,319 82 1-5 583 1,747 324 79 1.00 79 79
Zone I Subtotal 424 12,787 166 5,225 550 238 238 23$
-Zone 3-
It Bonus 333 9,990 130 2-6 523 4,519 307 206 1.00 206 2Wf
Zone 3 Subtotal 333 9,990 130 4,519 307 206 206 20tr
System 1 Totals 2337 92,621 1,204 32,911 3,761 1,497 1,704 1,497
Main Trunk Size: 16x16 in.
Cooling Sensible/Latent Sensible Latent Total
Tons Split Btuh Btuh Btuh
Net Required: 3.056 900/0/10% 32,911 3,761 366,672
Recommended: 3.562 770/o/23% 32,911 9,831 42,742
Tuesday,June 25,2002