HomeMy WebLinkAbout171 Beelzebub Road (6) DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT
#
Application is hereby: TOWN OF SOUTH WINDSOR I��a PERMIT
BUILDING DEPARTMENT
APP VED rl
1540 SULLIVAN AVENUE Bldg.Permit#
I- r 644-2511 ext. 230
ate Building Inspector
Application must be printed or typed
FEE SCHEDULE
Location of Job:
$0- $1,000=$13.00 Street No. Street Lot No.
Over$1,000=
$13.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT c
APPLICANT ADDRESS /pU A leSr -'?el �.v.
II •✓p�a N C7
APPLICANT PHONE# 9740 - Ob
OWN S� OWNER
OWNERADDRESS
OWNER PHONE
ESTIMATED COST$ D 00
��.
IS THIS A CONTRACT COST? , Yes 13 No
-� UV
i CJ FEE ENCLOSED$ A) i
OR-CO TYPE OF JOB: i
S
)VNew Installation
O Alteration/Addition/Repair Revised 8/99
d
APPLICATION FOR HVAC PERMIT (Continued from reverse side
TYPE OF YSTEM: TYPE OF UILDING:
15 HEATING VRESIDENTIAL
❑A/C ❑COMMERCIAL
❑VENTILATION ❑INDUSTRIAL
HEATING
❑ TEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
WHYDRONIC ❑WARM AIR ❑UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION �y�
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
PE-cZZss e'os7 ::I_XeyV /.30. G,4 oC.I lva✓ o 51
GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH)
TYPE OF WEL
BOIL—GPM OIL TANK LOCATION INSIDE❑ OUTSIDE CAPACITY Z 7�
❑GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW
AIR CONDITIONING
DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE/ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
e
N/G LlJyliz7�T�!/�'1/in�g /'�ut/4 D/✓��
s
TONNAGE COOLING CAPACITY(BTUH)
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK � e7- Lc%rrc
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
3gs�r, Sl ax vu
CONTRACTORS LICENSE NO. E STATE
SIGNATURE OF APPLICANT 4:�� /_ z DATE
(S� �
RIGHT-J SHORT FORM
Entire House
Homestead Fuel Inc Job: 4-2-01
100 West Rd Unit II,Ellington.CT 06029 Phone 870-8700 Fax 870-7731
Project Information
For- R Schneider Builders/Rood
Hillcrest Dr, Tolland, CT 060-84
Phone: 875-4734
N ' e • It
Htg Clg Infiltration
Outside db (°F) 0 95 Method Simplified
Inside db (°F) 70 75 Construction quality Avera e
Design TD (°F) 70 20 Fireplaces g
Daily range - M 0
Inside humidity(%) - 50
Moisture difference (gr/lb) - 11
HEATING EQUIPMENT COOLING EQUIPMENT
Make Make
Trade Trade
Efficiency 80.0 AFUE Efficiency 0.0 EER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Low output baseboard 560 Btuh/ft Total cooling 0 Btuh
Total low baseboard 146 ft Actual cooling fan 179 High output baseboard 1 cfm
800 Btuh/ft Cooling air flow factor 0.053 cfm/Btuh
Total high baseboard 102 ft
Space thermostat Load sensible heat ratio
93
ROOM NAME Area Htg load Clg load Baseboard (ft) Clg AVF
(ft2) (Btuh) (Btuh) Low High (cfm)
Breakfast/Kit 299 11804 3497 21 15 Dining Room 195 8836 4245 16 11 187
Living Room 270 18602 9655 33 23 227
Foyer 170 7482 1590 13 9 516
LDav/Laundry 190 en 2317 1695 10 7 95
2nd Floor 0 0 60 26 4 3 14
1712 9 6
Bedroom II 143 5200 0 0 6 0
Bath 92
Bedroom III 120 2836 1140 5 4 17
Bedroom IV 106 2053 61
Mas Bath/Closet 169 2832 115906 4 3 48
6 5 4 62
Master-Bedroom 252 11971 6851 21 15
Walk-in Closet 49 1353 366
458 2 2 24
Bold/ltalic values have been manually overridden
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
W r19 h tSQft Right-Suite Residential*'5 0 28 RSR27407
,CCK C\My Doc uments\WrightsoR HVACIR Schneider-Rood rsr
2001-Apr-03 08 32 31
Page 1
Entire House 2076 81697 33486 146 102 1791 .
Ventilation air 0 0
Equip. @ 1.00 RSM 33486
Latent cooling 2333
TOTALS 2076 81697 35819 146 102 1791
BolaVitalic values have been manually ovemdden
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
„4 wright5c3ft Right-Suite ResidentialTM 5 0 28 RSR27407 2001-Apr-03 08 32 31
ACCKC\My Documents\Wnghtsoft HVAC\R Schneider-Rood rsr Page 2