APPLICATION FOR HVAC PERMIT (Continued from reverse side
TYPE OF SYSTEM: TYPE OF BUILDING:
❑HEATING KRESIDENTIAL
AA/C ❑COMMERCIAL
❑VENTILATION ❑INDUSTRIAL
HEATING
❑ STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
❑HYDRONIC ❑WARM AIR ❑UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH)
TYPE OF FUEL
❑ OIL—GPM OIL TANK LOCATION:❑INSIDE❑OUTSIDE CAPACITY
❑GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW
AIR CONDITIONING
DESIGN TEMP.OUTSIDE OF INSIDE 71!r OF DIFFERENCE 010 OF
TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
j4KE-e 9iga <nWoO C414 Ohs . 7400 Iva#
6foLtC44 Sr OIW +10- ffvWDa-X. rWC 0� 140It
TONNAGE 3� COOLING CAPACITY(BTUH)_CAM
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
(PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK_ IA(571 jc l rl d lJ d l " C&"rAm- 01;f' G"1 n®1�tlAf L
Lj
THE tJNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
$v 34/1$ 9-1 Cr
CONTRACTORS LICENSE NO. TYPE STATE
DATE p Z 7 d 3
SIGNATURE OF APPLICANT
Right-A Worksheet Job: 38 Bancroft Lane South W11
° Entire Hous Date: F bruary 21,2W3
o By: DJS
Ka d n Fuel Company
340 Tolland Street,East Hartford,CT 06108 Phone:860-289-5431 Fax 860-289-2133 Email:dansymolon@aol.com
1 Room name Entire House Room1
2 Exposed wall 264.0 ft 132.0 ft
3 Ceiling height 8.0 ft d 8.0 ft heat/cool
4 Room dimensions 40.0 x 26.0 ft
5 Room area 2080.0 ft' 1040.0 ft2
Ty Construction U-value Or HTM Area (ft-) Load Area (ft-) Load
number (Btuh/ft2-'F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 12C-Osw 0.091 n 5.82 1.75 640 511 2976 895 320 251 1482 440
L::oG 1 D-c2ow 0.570 n 36.48 18.25 108 0 3940 1971 48 0 1751 876
11 DO 0.390 n 24.96 9.46 21 21 524 199 21 21 524 199
W 12C-Osw 0.091 a 5.82 1.75 416 392 2283 687 208 196 1142 343
11 L--G 1 D-c2ow 0.570 a 36.48 60.15 24 0 876 1443 12 0 438 722
V�J 12C-Osw 0.091 s 5.82 1.75 640 562 3273 984 320 266 1549 466
-G 1 D-c2ow 0.570 s 36.48 31.61 78 0 2845 2466 54 0 1970 1707
W 12C-Osw 0.091 w 5.82 1.75 416 383 2231 671 208 187 1089 328
Ejo1 D-c2ow 0.570 w 36.48 60.15 12 0 438 722 0 0 0 0
II DO 0.390 w 24.96 9.46 21 21 524 199 21 21 524 199
C 16B-30ad 0.032 - 2.05 1.53 2080 2080 4260 3178 1040 1040 2130 1589
F 19C-19cscp 0.049 - 1.09 0.22 2080 264 2261 466 1040 132 1131 233
Envelope loss/gain 26431 13881 13709 7101
12 a) Infiltration 22437 2414 11218 1207
b) Ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances a@ 1200 0 0 0 0
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 48867 16295 24928 8308
15 Duct loads 15% 17% 7311 2822 15% 17% 3729 1439
Total room load 56178 19118 28657 9747
Air required(cfm) 1023 1023 522 522
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
fi w W-IQ"tsoft Right-Suit Resid Mial J8 5.8.15 RSR30950 2003-Feb-21 08:10:31
AM C:\My DocumentslWrightsoft HVAC\TemplateU(asden Fuel Project.rrt Calc=MJ8 Orientation-N Page 1