Loading...
HomeMy WebLinkAbout1739 Ellington Road (20) . Electric# Ps o 11F ;tp4 1 P`'"A`�' 44�{ r s"`' APPLICATION FOR BUILDING PERMIT Plumbi�ng# p yidD. '� e l9�� 1739 Ellington Road WVAC # 5-0S- : ; molf Date: r4o. 28699 Sprinkler# 4 ILI 0 ' 2 3 De G FINAL A"! V Estimated Cost $`0 ZOSc9oo Building 3 �? a 3 COMPLETE RED BOXED AREAS Permit Fee $ 3 07.r' Engineering TYPE TYPE OR PRINT ONLY Occupancy Fee t Affidavit SIGN ON REVERSE SIDE Appr.for CO. Total Fee $ :5 TO BUILDING'DEPARTMENT,TOWN OF SOUTH WWSOR,CT (Additional Cost) $ The undersigned hereby applies to do work according to t6j+ying specifications: 2 p .lob Locafio0a AirFve RAotNo. Side of Street_Zone Applicant n6r.-a-` E: rgS aalri-&A66 a 6!6P27',tNcTel.#&0 Z a-SS45� Address 70 as `r1A) iZS- So l7CoO^1,4c1,C L] c7-Zip �,002 Lic.#1D00 4 '5' Owner7/�1f' 15"IZW It5fte'r Tess AVBS0114A/DC0C k' ST at/VG Z/6 ArchitectLANyIZy Address A'gj,-0 Sr- fg1-6-Ar7 I/� 030 Sq. Ft.New Area: 1st FI. �` 2nd FI. 969Z,90 3rd Fl. Total New Area #Rooms #Lavatories #Bathrooms #Garages Purpose of this permit: CON 9 f//OjE�Z 5 7'0P SyP��i�G�r.�• City Water Well ❑ Septic System ❑ Sewer Ins. H.O. S.P. Cart. VArea Basement Garage Approved by �AAI Date Ld o Use Group Construction Type Ravi ed 1197 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which is buildiN and its allowed. Signed I hereby apply for a Certificate of Occu ncy for the ribed in this application for the permit. Signed A�nxe ;rZ1 DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS q Location of Job: AFFIDAVIT Additional Fee$ 7 State of Connecticut ss.South Windsor County of Hartford Owner I of Agent for the building erected Contractor under Permit No. 2 8 6 9 9 issued by the Building Department of the Town of South Windsor being duly sworn,make oath and say that the actual cost of the completed work authorized under said permit was Signed Subscribed and sworn to before me this day of A.D.20 Estimated Cost$ 3, 613, 940 . Difference: $ Notary Public ...,,, "',��"., 1 •3C► UbVb44 lldb SOUTH WINDSOR PAGE 05 Ucation of Job*- "FMAVff Addiaond Fees 8 p 0 0 State of Connecticut s:.South WSndsox . Coa�,ty o�'�rtxord I ,MIFF C. ARMO Lh 0� 1�1�T1�'T1- � R� �Cs3tl- C O�►nor Agwd for the b4ftg erected antler Permit No. 2.Q,(0 9 q iced by aw Bob . Cownctor 4Y 5*6M kw u oar*�d:oy that tie atuol ro#of the � of tote Taws,of so%*Windsor , Comp work agtb►ori,�oed wader aid permit was 4 2-14 9Z l wed -t��A..- c� .� .�.�.�e R( • Sfibsc*ed Md MOM to before me day of Mk2Ci A.D.2903 Estabwted Cost Y DMermm Notayy • . 9��o �a66' )£RM IT CAs'f ate SouTAA �1N�So(Z 3 (0 1 -�>) 1 4 0 �Et�MtiT zq 18�> Nov NA1-W'br-0 -14 3,000 Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-28699-B 2,205,000 B01 FOOTING 05/21/02 CJD D SITE LIGHTING FOUNDATIONS INSTALLED WITH NO INSPECTIONS. ENGNEER APPROVAL REQ.W/BRUCE B01 FOOTING 05/28/02 JFF A WITH SUPER JERRY 1LINE 20FT NORTH OF F LINE TO 20FT NORTH OF C LINE 300000NCRETE B01 FOOTING 05/29/02 JFF A REMAINDER OF 1 LINE W/CONTRACTOR B01 FOOTING 05/30/02 JFF A G LINE TO H 1 TO SPT3 B01 FOOTING 05/31/02 CJD N/A B01 FOOTING 06/10/02 CJD A B-LINE APPROX 40' WALLS AT NWEST CORNER 60' B01 FOOTING 06/14/02 WNB A LINE 6 FB-C LINE 10OFT WITH SUPER JERRY B01 FOOTING 06/18/02 CJD D NO INSPECTIONS ON BLINE 1.6-5.9.E.D,F,FB,F.C, F.D,G.B.4.5-7.LINE 6-G.B-A NO WALLS OR FTGS P02 UNDERGROUND 06/18/02 CJD D NO PLMG. PERMIT. 6.51HEAD WOULD NOT HOLD WTR. AT SAN.DRAINS,3.5@E.D,F&4.8-D.0 @ BLDG.EXIT P02 UNDERGROUND 06/19/02 CJD A W/PLUMBER-RELATIVE TO LINES IN PREVIOUS DENIED INSPECTION B01 FOOTING 06/20/02 JFF D LOADING DOCK AREA BLINE TO AB LINE 1 LINE T01 8 APPROVAL UPON RECEIPT OF DR WELTIS REPORT B04 INSULATION . 06/20/02 JFF A PERIMETER SLAB INSULATION 2IN STYROFOAM WITH JERRI BBE SUPER Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- P02 UNDERGROUND 06/21/02 CJD A W/PLUMBR.-10' HEAD ON BALANCE OF SANITARY AND GREASE TRAP LINE B02 FOUNDATION 06/24/02 CJD A W/JERRY-1.0-1.4 LINES A$B WALL P02 UNDERGROUND 06/25/02 CJD A W/ERIC-SANITARY 1.8-3.0 AT LINE B-B.D P02 UNDERGROUND 06/27/02 CJD A WET TEST-101 .GREASE WASTE LINE D-B.C-1-2.5 B09 OTHER 06/28/02 CJD N/A VERBAL W/SUPER JERRY FOR 6' PROTECTIVE BARRIER @ PUBLIC WAY P02 UNDERGROUND 07/05/02 CJD A GREASE TRAP LINE LAST LEG OK P02 UNDERGROUND 08/09/02 CJD A W/PLUMBER-4.3-6. AND A.C-B.D. 3RD COMMUNCATN W/CM REGRDNG.PROTECTIVE BARRIER ARND CONSTR. P02 UNDERGROUND 07/09/02 CJD A SOUTH WEST GRID TO BUFFER BASIN P02 UNDERGROUND 07/12/02 CJD A SE QUADRANT P02 UNDERGROUND 07/17/02 CJD A E02 UNDERGROUND 07/17/02 CJD A NRTHWEST END OF BLDG. TO COLUMN C-LINE S05 HYDRO TEST 07/18/02 CJD A W/TECH 210#S 2HRS. P02 UNDERGROUND 07/18/02 CJD A W/ERIC LAST QUADRANT-SE CORNER E02 UNDERGROUND 07/18/02 CJD A W/ELECTRICIAN TO COLUMN C-LINE FOR FIRST POUR E02 UNDERGROUND 07/19/02 CJD A LINE 2.1-4.2 Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- E02 UNDERGROUND 07/22/02 CJD A W/CONTRCTR. PRIMARY CONDUIT P02 UNDERGROUND 07/24/02 CJD A W/ERIC NE LINE TO BUFFER BASIN AT FISH TANK P02 UNDERGROUND 07/26/02 CJD A WET TEST AT NORTH EAST BUFFER BASIN LAST RUN E02 UNDERGROUND 07/29/02 CJD A W/ELECTRICIAN-CONDUIT TO TRANSFORMER VAULT E02 UNDERGROUND 07/31/02 WNB A WITH CONTRACTOR CHIP,WALKER DUCT EAST SIDE 80 FT E02 UNDERGROUND 08/01/02 CJD A W/CHIP E02 UNDERGROUND 08/02/02 CJD A W/ELEC-LAST POUR AREA AT NORTHEAST QUADRANT B09 OTHER 08/13/02 JFF WITH NORM INT DEVELOPEMENT LETTER ON SHEATHIN TEST RESULTS ROOF COMPLETED E02 UNDERGROUND 08/14/02 CJD D LIGHTPOLE BASES NOT TO PRINT SPECS E02 UNDERGROUND 08/15/02 CJD A WEST LOT 4 UNITS B09 OTHER 08/21/02 JFF WENT OVER REQUIREMENTS FOR GENERATOR B09 OTHER 08/22/02 JFF WENT OVER GENERATOR REQUIREMENTS AN EXTERIOR BLOCK WALL AN SEISMIC E01 SERVICE 09/03/02 CJD D PROVIDE PROTECTION FROM RAIN WATER Q ELEC. PANEL/CABINETS B09 OTHER 09/04/02 CJD D SERV.DENIED UNTILL BLDG. DRIED IN,REMOVE SHT RCK.&INSUL.FROMSE WALL.CEASE PERIMETERWALL Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- B09 OTHER 09/04/02 CJD D CEASE WORK ON PERIMETER WALLS UNTILL DRIEDIN INSTALL TEMP LGHTNG TO CODE (FINAL WARNING) E03 ROUGH 09/05/02 CJD A MEZZININE AREA OK-PROGRESS MADE ON MAKING BLD WATER TIGHT,TEMP.LGHTNG. OK,SHTRCK.INSULREMVD P03 ROUGH 09/06/02 CJD A MEZZININE EMPLOYEE BTHRMS, DRAINS FIXTURE SUPPORTS E01 SERVICE 09/11/02 CJD A W/CHIP E03 ROUGH 09/17/02 CJD A W/CHIP-DELI, BAKERY,FISH TANK, UNDER MEZZININ P03 ROUGH 09/17/02 CJD A H2O,DWV FOR DELI,BAKERY,FISH TANKS E03 ROUGH 09/26/02 CJD A W/CHIP-PRODUCE AND FISH E03 ROUGH 10/03/02 JFF A WITH CHIP WEST WALL MEAT DEPT B03 FRAMING (ROUGH) 10/15/02 JFF A CEILING SALES AREA OK TO DROP PADS WALLS EAST HALF MEZZANINE WITH NORM E03 ROUGH 10/15/02 JFF A WALLS MEZZANINE WITH NORM EAST HALF OF MEZZ PO4 GAS TEST 10/16/02 JFF A TEMP GAS HOOK UP TO ROOF TOP UNIT WITH NORM PO4 GAS TEST 10/21/02 CJD A W/ERIC PLUMBNG CONTRACTOR-ROOFTOP UNITS E03 ROUGH 10/22/02 JFF A WEST ENTRYWAY WITH ELECT SUPER RIC B01 FOOTING 10/23/02 JFF A FRONT AN REAR WEST SIDE CONNECTOR FOOTINGS WITH NORM Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- B01 FOOTING 10/24/02 CJD A E03 ROUGH 10/31/02 CJD A FRONT EAST ENTRANCE.WALL ABOVE CEILING. B09 OTHER 11/01/02 CJD A TEMP. CO FOR EMPLOYEE HIRING ONLY.RESTRICTED SQ.FT AREA FRONT OF STORE.FIRE SAFETY OK B03 FRAMING (ROUGH) 11/12/02 JFF A CEILING OK TO DROP PADS BAKERY AN DELI AREA WITH NORM P03 ROUGH 11/21/02 CJD A SOUTHWEST ROOF DRAIN CONDUCTOR WET TESTED NORTHEAST SET FOR 11/252002 B10 FINAL 11/25/02 CJD A W/NORM (SEE INSPECTION TICKET 11252002) B10 FINAL 03/17/03 JRC A CLOSED OUT. **-11061-P 300,000 **-11141-P 2,000 **-11505-H 143,000 **-1240-S 144,500 **-17880-E 777,000 **-1243-S 2,000 **-17971-E 4,300 **-17998-E 16,000 **-18039-E 8,000 Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------------------- **-18060-E 4,140 **-18065-E 8,000 Inspection / Approval Date By Appl Code Description Due Whom Code Comment ------------------------------------------------------------------ P03 ROUGH 09/06/02 CJD A MEZZININE EMPLOYEE BTHRMS, DRAINS FIXTURE SUPPORTS E01 SERVICE 09/11/02 CJD A W/CHIP E03 ROUGH 09/17/02 CJD A W/CHIP-DELI, BAKERY,FISH TANK, UNDER MEZZININ P03 ROUGH 09/17/02 CJD A H2O,DWV FOR DELI,BAKERY,FISH TANKS E03 ROUGH 09/26/02 CJD A W/CHIP-PRODUCE AND FISH E03 ROUGH 10/03/02 JFF A WITH CHIP WEST WALL MEAT DEPT B03 FRAMING (ROUGH) 10/15/02 JFF A CEILING SALES AREA OK TO DROP PADS WALLS EAST HALF MEZZANINE WITH NORM E03 ROUGH 10/15/02 JFF A WALLS MEZZANINE WITH NORM EAST HALF OF MEZZ PO4 GAS TEST 10/16/02 JFF A TEMP GAS HOOK UP TO ROOF TOP UNIT WITH NORM PO4 GAS TEST 10/21/02 CJD A W/ERIC PLUMBNG CONTRACTOR-ROOFTOP UNITS E03 ROUGH 10/22/02 JFF A WEST ENTRYWAY WITH ELECT SUPER RIC B01 FOOTING 10/23/02 JFF A FRONT AN REAR WEST SIDE CONNECTOR FOOTINGS B01 FOOTING 10/24/02 CJD A WITH NORM E03 ROUGH 10/31/02 CJD A FRONT EAST ENTRANCE.WALL ABOVE CEILING. B09 OTHER 11/01/02 CJD A TEMP. CO FOR EMPLOYEE HIRING ONLY.RESTRICTED SQ.FT .FIRE B03 FRAMING (ROUGH) 11/12/02 JFF A CEILINGREA OK TOONT DROPFPADSRBAKERY ANFETY DELIOAREA WITH NORM P03 ROUGH 11/21/02 CJD A SOUTHWEST ROOF DRAIN CONDUCTOR WET TESTED NORTHEAST SET FOR 11/252002 B10 FINAL 11/25/02 CJD A W/NORM (SEE INSPECTION TICKET 11252002) **-11061-P 300,000 **-11141-P 2,000 **-11505-H 143,000 **-1240-S 144,500 **-17880-E 777,000 **-1243-S 2,000 **-17971-E 4,300 **-17998-E 16,000 **-18039-E 8,000 **-18060-E 4,140 **-18065-E 8,000 940 Total Est Value 3,613, Inspection / Approval Date By Appl Code Description Due Whom Code Comment --------------------------------------------- **-28699-B 2,205,000 B01 FOOTING 05/21/02 CJD D SITE LIGHTING FOUNDATIONS INSTALLED WITH NO INSPECTIONS. ENGNEER APPROVAL REQ.W/BRUCE B01 FOOTING 05/28/02 JFF A WITH SUPER JERRY 1LINE 20FT NORTH OF F LINE TO 20FT NORTH OF C LINE 300000NCRETE B01 FOOTING 05/29/02 JFF A REMAINDER OF 1 LINE W/CONTRACTOR B01 FOOTING 05/30/02 JFF A G LINE TO H 1 TO 5PT3 B01 FOOTING 05/31/02 CJD N/A B01 FOOTING 06/10/02 CJD A B-LINE APPROX 40' WALLS AT NWEST CORNER 60' B01 FOOTING 06/14/02 WNB A LINE 6 FB-C LINE 10OFT WITH SUPER JERRY B01 FOOTING 06/18/02 CJD D NO INSPECTIONS ON BLINE 1.6-5.9.E.D,F,FB,F.C, F.D,G.B.4.5-7.LINE 6-G.B-A NO WALLS OR FTGS P02 UNDERGROUND 06/18/02 CJD D NO PLMG. PERMIT. 6.5'HEAD WOULD NOT HOLD WTR. AT SAN.DRAINS,3. .DF&4. . P02 UNDERGROUND 06/19/02 CJD A W/PLUMBER-RELATIVEETO,LINES-INCPREVIOUSEXIT DENIED INSPECTION B01 FOOTING 06/20/02 JFF D LOADING DOCK AREA BLINE TO AB LINE 1 LINE T01 8 APPROVAL UPON RECEIPT OF DR WELTIS REPORT B04 INSULATION 06/20/02 JFF A PERIMETER SLAB INSULATION 2IN STYROFOAM P02 UNDERGROUND 06/21/02 CJD A W/PLUMBR.-10' HEADEON BALANCE OF SANITARY P LINE B02 FOUNDATION 06/24/02 CJD A W/JERRY-1.0D GREASE T11..4 LINES A$B WALL P02 UNDERGROUND 06/25/02 CJD A W/ERIC-SANITARY 1.8-3.0 AT LINE B-B.D P02 UNDERGROUND 06/27/02 CJD A WET TEST-10' .GREASE WASTE LINE D-B.C-1-2.5 B09 OTHER 06/28/02 CJD N/A VERBAL W/SUPER JERRY FOR 6' PROTECTIVE WAY P02 UNDERGROUND 07/05/02 CJD A GREASERTRAPUBLIC LINE LAST LEG OK P02 UNDERGROUND 08/09/02 CJD A W/PLUMBER-4.3-6. AND A.C-B.D. 3RD COMMUNCATN P02 UNDERGROUND 07/09/02 CJD A SOUTHRWESTNGRIDOTIVE TOCBUFFERARRIER BASIN ARND CONSTR. P02 UNDERGROUND 07/12/02 CJD A SE QUADRANT P02 UNDERGROUND 07/17/02 CJD A E02 UNDERGROUND 07/17/02 CJD A NRTHWEST END OF BLDG. TO COLUMN C-LINE SOS HYDRO TEST 07/18/02 CJD A W/TECH 210#S 2HRS. P02 UNDERGROUND 07/18/02 CJD A W/ERIC LAST QUADRANT-SE CORNER E02 UNDERGROUND 07/18/02 CJD A W/ELECTRICIAN TO COLUMN C-LINE FOR FIRST POUR E02 UNDERGROUND 07/19/02 CJD A LINE 2.1-4.2 E02 UNDERGROUND 07/22/02 CJD A W/CONTRCTR. PRIMARY CONDUIT P02 UNDERGROUND 07/24/02 CJD A W/ERIC NE LINE TO BUFFER BASIN AT FISH TANK P02 UNDERGROUND 07/26/02 CJD A WET TEST AT NORTH EAST BUFFER BASIN LAST RUN E02 UNDERGROUND 07/29/02 CJD A W/ELECTRICIAN-CONDUIT TO TRANSFORMER VAULT E02 UNDERGROUND 07/31/02 WNB A WITH CONTRACTOR CHIP,WALKER DUCT EAST SIDE 80 FT E02 UNDERGROUND 08/01/02 CJD A W/CHIP E02 UNDERGROUND 08/02/02 CJD A W/ELEC-LAST POUR AREA AT NORTHEAST QUADRANT B09 OTHER 08/13/02 JFF WITH NORM INT DEVELOPEMENT LETTER ON SHEATHIN TEST E02 UNDERGROUND 08/14/02 CJD D LIGHTPOLELTS BASESONOTOETED TOLPRINT SPECS E02 UNDERGROUND 08/15/02 CJD A WEST LOT 4 UNITS B09 OTHER 08/21/02 JFF WENT OVER REQUIREMENTS FOR GENERATOR B09 OTHER 08/22/02 JFF WENT OVER GENERATOR REQUIREMENTS AN EXTERIOR BLOCK WALL AN SEISMIC E01 SERVICE 09/03/02 CJD D PROVIDE PROTECTION FROM RAIN WATER @ ELEC. PANEL/CABINETS B09 OTHER 09/04/02 CJD D SERV.DENIED UNTILL BLDG. DRIED IN,REMOVE SHT RCK.&INSUL.FROMSE WALL.CEASE PERIMETERWALL B09 OTHER 09/04/02 CJD D CEASE WORK ON PERIMETER WALLS UNTILL DRIEDIN INSTALL TEMP LGHTNG TO CODE (FINAL WARNING) E03 ROUGH 09/05/02 CJD A MEZZININE AREA OK-PROGRESS MADE ON MAKING BLD WATER TIGHT,TEMP.LGHTNG. OK,SHTRCK.INSULREMVD TRANSMISSION VERIFICATION REPORT TIME 03/07/2003 12:31 DATE,TIME 03/07 12:30 FAX NO./NAME 92438929 PAGE(S) :01:10 05 RESULT OK MODE STANDARD ECM FAX COVER SHEET BUILDING DEPARTMENT TOWN OF SOUTH WINDSOR 1540 SULLIVAN AVENUE Y SOUTH WINDSOR, CT 06074 x �` (860) 644-2511 EXT. 230 FAX (860) 644-3781 �1`�'dsOR.co�`'�G Date: Arc 02 U TO: ( n� f l� v (� COMPANY: FAX NO.: FROM: n C� TITLE: MESSAGE:- r P �- If you did not receive all pages (including the cover), or if you have any questions, please call 644-2511 ext. 230 as soon as possible. Location of Job: AFFIDAVIT Additional Fee$ State of Connecticut ss.South Windsor County of Hartford Owner I of Agent for the building erected Contractor under Permit No. 2 8 6 9 9 issued by the Building Department of the Town of South Windsor being duly sworn,make oath and say that the actual cost of the completed work authorized under said permit was Signed Subscribed and sworn to before me this day of A.D.20 Estimated cost$ 3,613, 940o Difference: $ Notary Public Location of Job: AFFIDAVIT Additional Fee S State of Connecticut ss.South Windsor County of Hartford Owner I of Agent for the building erected Contractor under Permit No. issued by the Building Department of the Town of South Windsor being duly sworn,make oath and say that the actual cost of the completed work authorized under said permit was Signed Subscribed and sworn to before me this day of A.D.20 Estimated Cost S Difference: S Notary Public II ii. 70 GRIFFIN ROAD SOUTH, BLOOMFIELD, CT 06002-1352 (860) 242-5565 FAX (860) 243-8929 March 14, 2003 Mr. John Collins Chief Building Official Building Department Town of South Windsor 1540 Sullivan Avenue South Windsor, CT 06074 RE : Bartlett Brainard Eacott Permit#28699 Attached is the cost Affidavit for Permit#28699 - Stop & Shop from Bartlett Brainard Eacott, Inc.. The total for all costs on this project were $4,242,492. This exceeded the original estimate of$3,6566,940 by $585,552. A check for$8,790 ($586*$15/1000) has been included as a final true-up payment for this permit. The original estimate consists of$3,613,940 per you worksheets plus permit#29188 from Otis Elevator for$43,000 which should be part of this job. If you have any questions, or require additional information, please contact me at (860) 380-5530. Sincerely, �J James C.D. Arnold Controller/CFO