Loading...
HomeMy WebLinkAbout176 Oak Street t I 's DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT 220 App 1540 SULLIVAN AVENUE Bldg.Permit# cc 644-2511 ext. 230 o3 JXe—, Date Building Inspector r , , Application must be printed or typed f Location of Job: FEE SCHEDULE 3 f `S r i $0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= $15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANTCC) H A C APPLICANT ADDRESS Sum pz� r_ r)e (o APPLICANT PHONE# f 6 U 1(Q c?� W H $t OWNER /14 G e n F. I/ q� OWNER ADDRESS # OWNER PHONE ESTIMATED COST$ f 3 C i t IS THIS A CONTRACT COST? t/4es No FEE ENCLOSED$ o TYPE OF JOB: OR-Co d k New Installation Alteration/Addition/Rep air Revised 4101H2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: ❑HEATING ❑RESIDENTIAL JAI ❑COMMERCIAL VENTILATION ❑INDUSTRIAL HEATING ❑STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. ❑HYDRONIC ❑ WARM AIR ❑UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL ❑ OIL—GPM OIL TANK LOCATION:❑INSIDE❑OUTSIDE CAPACITY ❑GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE ns COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFMr- (PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. S- 1 -�)a -)cl47 F CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT 01. DATE Page 1 Resid ntial Heat Loss and Heat Gain Calculation 7/7/2003 In accordanc with ACCA Manual J Report Prepared By: Tin Works Inc. For: Geoffroy House South Windsor, CT Design Conditions: South Windsor Indoor: Outdoor. Summer temperature: 68 Summer temperature: 97 Winter temperature: 76 Winter temperature: -4 Relative humidity: 55 Summer grains of moisture: 86 Daily temperature range: High Building Component Sensible Latent Total Total Gain Gain Heat Gain H at Loss (BTUH) (BTUH) (BTUH) (BTUH) Whole House 1,223 sq.fL 19,303 31670 22,973 429904 (2tons) Second Floor— - -_ -- -- -- _ 19,303 ------ ^ 3,671__ 22,974 42,903 ---------- --- Master Bedroom 240 sq.ft. -_ 4,179 1,015 5,194 71551 Bedroom#2 240 sq.ft. 3,519 555 4,074 7,551 - -- --- -- --- - ---- -- --- — ------------------ -- Hall 120 sq.ft. 304 0 304 530 - -- ---- -------------------------------------------- ------------------ -- Bedroom#3 192—sq.ft. 2,636 ---------- ----370 3,006 4,939 ---- ------------------------- ----------------------- -- ---- ---- Bathroom- — _— 96 sq.ft`-- -1,079 139 _ _1,218 2,046 Living Room-downstairs 225 sq.ft. 5,027 1,384 __ 6,411 16,317 'Kitchen-Downstairs 110 sq.ft. 2,559 208 2,767 3,969 VYiMb#louse 1,223 sq.tL 19,303 39670 229973 429904 (2tons) HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates ongr,actual loads may wary due to weather and lion differences. Page 1 Resid ntial H at Loss and H at Gain Calculation 7/7/2003 In accordance with ACCA Manual J Report Prepared By: Tin Works Inc. For: Geoffroy House South Windsor, CT Total CFM: 800 Room Cooling CFM Heating CFM Both Second Floor 800 800 800 -------Master Bedroom 173 141 173 -- ------- ----------------------------------------- ---- - - - Bedroom#2 146 141 146 _Hall 13 10 13 Bedroom#3 ------------------- ----- --- ----109 ----------- 92 ----------- 109 Bathroom 45 38 45 Living Room-downstairs_____ 208 304 304 Kitchen-Downstairs 106 74 106 HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only,actual loads may very due to weather and construction differences.