Loading...
HomeMy WebLinkAbout125 Ellingtion Road (6) BUILDING CODE REVIEW DST Output- New Addition & Existing Building 125 Ellington Road Building Code: The BOCA National Building Code/1996 Use Group: - B Office Area, Table 304.2 -S-1 Warehouse &Generator Building, Table 311.2 - F-1 Printing & Mailing, Table 306.2 Construction Type: -2C Table 602 Area&Height Limitations: Building to be fully sprinklered - Nonseparated Use Groups, Sec. 313.1.227 - Unlimited Areas, Sec. 507.1 - Fire Separation, Exterior Walls, Sec. 507.2, Distance>50 feet= No firerating required Height<85 feet=O.K. Building Area: B: Office Area First Floor 22,875 s.f. Mezzanine 39,644 s.f. Total 62,519 s.f. S-1: Warehouse 61,907 s.f. F-1: Printing & Mailing 125,690 s.f. Total 250,116 s.f. S-1: Generator Building 2,940 s.f. Length of Exit Travel: B, F-1,S-1 with Sprinkler System =250 feet maximum =O.K. Table 1006.5 Occupant Load: See attached sheet from DST Output Facility Parking Requirements: Parking Calculations to be provided by Design Professionals,Inc. Present work force Department 1 st shift 2nd shift 3rd shift Tem s Total Peak Period temL2 adds Peak Period Total Lettershop 48 38 21 7 114 30 144 Maintenance 2 2 2 0 6 0 6 Print 19 0 19 1 39 20 59 DP/LAN 6 2 2 0 10 0 10 COM/ROM 4 0 0 0 4 0 4 Whse/Trans 8 2 2 0 12 0 12 HR/Training 10 0 0 0 10 0 10 All other 165 0 0 0 165 0 165 262 44 46 8 360 50 410 Proposed rowth Del2artment 1 st shift 2nd shift 3rd shift Tem s Total Peak Period tem adds Peak Period Total Lettershop 30 25 15 7 77 30 107 Maintenance 2 2 2 0 6 0 6 Print 19 0 19 1 39 20 59 DP/LAN 0 0 0 0 0 0 0 COM/ROM 0 0 0 0 0 0 0 W hse/Trans 2 1 1 0 4 0 4 HR/Training 2 0 0 0 2 0 2 All other 0 0 0 0 0 0 0 55 28 37 8 128 50 178 GRAND COMBINED TOTAL 317 72 1 83 16 488 100 588