HomeMy WebLinkAbout19-05P NuWay Tobacco Minor Site Plan Mod TOWN OF SOUTH WINDSOR
PLANNING &ZONING COMMISSION
APPLICATION FORM
RECEIVED.,",",--,
Application Number:
Official Receipt Date: "ZZ-" JAN 6 ZO1 411
Munis Application #: O',C)
SOUTH VNNDSOR PLANNING-DEPT.
APPLICANT: NuWay Tobacco, David Fresk
PROJECT NAME: Nu-Way Tobacco
COMPLETE LOCATION OF PROPERTY: 200 Sullivan Avenue
OWNER OF RECORD ON LAND RECORDS: 200 Sullivan Avenue, LLC
OWNER ADDRESS: P.O.Box 415,East Windsor Hill,CT 06028
GIS PIN # 87300200 ZONE I
NAME, ADDRESS, TELEPHONE 8v EMAIL ADDRESS OF PERSON TO WHOM INQUIRIES SHOULD BE DIRECTED:
Suzanne P.Choate,P.E.. Design Professionals, Inc..21 Jeffrey Drive,South Windsor,CT
06074,860-291-8755,schoate@dpinc.co Estimated presentation time:N/A
THIS APPLICATION IS FOR: (Check all that apply):
❑ Zone Change to (Public Hearing and Certificate of Mailing Required)
❑ Open Space Subdivision/Resubdivision (Public Hearing and Certificate of Mailing Required)
❑ Subdivision ❑ Minor ❑ Major
❑ Resubdivision (Public Hearing Required) ❑ Minor ❑ Major
❑ Conditional Subdivision
❑ Special Exception to Table (Public Hearing and Certificate of Mailing Required)
❑✓ Site Plan of Development ❑ New ✓❑ Modification Building(s) Sq Ft 1250 sf
❑ General Plan of Development
❑ Earth Filling (Sec. 7.6) and/or Earth Removal (Sec. 7.16) (Public Hearing and Certificate of Mailing Required)
❑ Regulation Amendment ❑ Zoning ❑ Subdivision -Attach proposed amendment (Public Hearing Required)
❑ Temporary and Conditional Permit (Public Hearing Required) for
❑ Temporary and Conditional Permit Renewal for
❑ Detached In Law Apartment or ❑ Accessory Apartment (Public Hearing and Certificate of Mailing Required)
❑ Major Home Occupation (Certificate of Mailing Required) for
❑ Other (explain in detail)
PLEASE NOTE: An Application Pending Sign is re ' d to be posted on the property for all applications
ten (10) days prior to being heard by the Commis on.
a
Signature of Applicant S` ature o erty Owner
Print Name of Applicant Print Name of Property Owner Revised 1/9/2017
TOWN OF SOUTH WINDSOR CHECKLIST
REQUIRED INFORMATION SITE PLANS
APPLICANT 200 Sullivan Ave.,LLC
PROJECT NAME Nuway Tobacco
This checklist must be signed by plan preparer (P.E./L.S.) declaring that all required information
is provided. Items 1-7 are required for all applications; items 8-11 required where appropriate.
Check mark for each item supplied.
1. On each sheet for plans or maps, title block with the following information:
✓ a. Name, address and telephone of applicant.
✓ b. Name, address and telephone number of Land Surveyor or Professional
Engineer.
✓ c. Name of Development.
✓ d. Date when drawings were made.
✓ 2. Key Map: An overall map drawn to a scale of 1 inch equals either 100 feet or
200 feet. This map will show the overall design of the Development and
surrounding property within 500 feet.
✓ a. Data block which gives needed zoning information such as percentage of
lot coverage, acreage of tract, number of apartment units, parking
requirements, etc.
b. Outline of buildings.
c. Layout of streets.
d. Surrounding property boundaries-within 500 feet.
e. Names of abutting property owners.
N/A f. Proposed open spaces and recreation areas.
✓ g. Driveway cuts on abutting properties and any properties across from
proposed site.
h. Distance to and name of nearest intersection street.
N/A 3. Architectural Elevations: See attached checklist for Architecture and Design
Review.
i
✓ 4. Plot Plan: A layout map of the proposed site drawn to a scale of 1 inch equals
40 feet on either of the following size sheets: (1) 24" x 36" with a 3/4" ruled
margin; (2) 18" x 24" with a 1/2" ruled margin, containing the following data:
✓ a. Distance and bearings of all boundary lines and acreage of site. Iron pins
required at all property angle points and shown on map.
N/A b. Proposed streets and street lines with center line station, curve data, and
parking spaces.
c. Building lines in accordance with zoning regulations.
d. Proposed buildings and other structures, including signs, outside lighting,
and dumpsters (on concrete pad and screened).
N/A e. Easements, noting grantors, grantees, and purpose must be shown in
table format, e.g. below
Grantor Grantee Type of Date Filed Vol/Pg
Easement
✓ f. Names of abutting property owners.
g. Monuments will be indicated at corners and angles of all streets and at all
points of curvature and tangency. The monumented points within
proposed site shall be coordinated. These coordinates shall appear in
tabular form on the plot plan. The accessibility of these CGS points shall
be determined by the Town Engineer.
h. All open space or other common or public land uses shall be indicated.
✓ i. A-2 certification; P.E./L.S. Seal.
5. Topographic Map: A map drawn to a scale of 1 inch to 40 feet on sheets not
exceeding 24 inches by 36 inches, including ruled margins shall in addition to
the requirements of the plot plans show the following:
a. All existing and proposed buildings.
✓ b. Curb Lines and pavement width, sidewalks.
✓ c. Existing and proposed sanitary sewers.
✓ d. Existing and proposed water and-all existing utilities.
2
✓ e. Present wooded area indicated by foliage lines. Any trees to be saved
should be shown.
N/A_ f. Existing and proposed contours shall be shown in not less than two-foot
intervals, but in cases of relatively level land, the contours shall be one-
foot intervals and spot elevations.
g . Regulated wetlands and 100-year floodplain or note that none are
present.
N/A h. Proposed storm drainage system, showing all catch basins, endwalls,
manholes, lengths and sizes of pipes and elevations of structures.
(Maximum distance between catch basins shall be 300 feet and minimum
size of storm drain lines shall be 15 inches, within Town ROW.) If
plan/profile sheet is provided all of this does not need to be shown. Only
top of frame elevations and inverts of open discharge pipe shall be shown
on this plan.
N/A i. Connections of all springs into proposed storm drainage system as
needed.
N/A j. Location and indications of existing brook channels, and 100-year flood
limits.
N/A k. A-2 &T-2 Certification; P.E & L.S. Seals.
N/A 6. Landscaping plan
N/A 7. Drainage calculations: - Zero Runoff Increase per attached guidelines.
Minor increase in runoff will a negligible effect on site drainage.
N/A_ 8. Traffic Report
N/A 9. Site Lighting Plan
N/A 10. Plans and Profiles: A plan and profile of the proposed streets drawn on
plan/profile paper of scales 1 inch to 40 feet horizontally, and 1 inch to 4 feet
vertically on sheets not exceeding 24 inches by 36 inches, including ruled
margins and containing the following:
N/A a. Layout of streets in sections coordinated by stations with the profile.
N/A b. Street plan showing roadways, drainage, sanitary sewer (including house
sewer), foundation drains, lot lines, buildings including all utilities with
elevations (top frame and inverts), size, type, length, slopes of pipes.
N/A c. Sight line at driveway &street intersections.
3
d. Profile of roadway showing existing and finished grades. Roadway profile
will show all tangent grade and all vertical curve information.
e. Profile will show all catch basins and all drainage lines between catch
basins with all invert and top of frame elevations, sizes, lengths and
slopes of pipes.
f. Where any storm drainage line discharges into an existing brook sufficient
profile of this brook will be shown to determine conditions.
g. CGS datum shall be used on all sites accessible to these controls. The
Town Engineer shall, based on standard engineering practices, determine
the accessibility of these controls.
h. Profiles shall show all sanitary sewer lines and manholes, including
elevations, (inverts, top of frame) sizes, lengths, and slopes of pipes.
Top of foundation elevations for building shall be shown.
11. Open Space Site Improvement Plans: For sites which require or include a
provision for open spaces, a plan which contains data for site improvement
may be required. This map shall be drawn to a scale of 1 inch equals 40
feet.
12. Sanitary Report: Where individual sanitary sewage disposal systems are
proposed, the final plans shall include a Sanitary Report certified by a
Professional Engineer. The report shall demonstrate the feasibility of the
proposed individual systems.
Suzanne P. Choate, P.E.
i
PLAN PREPARER (P.E./L.S.) DATE
February 2002; Rev. 4-04
4
PLANNING DEPARMENT
IN-HOUSE REFERRAL FORM
DATE: 1/17/19
TO: Matt Galligan, Michael Gantick, Walter Summers, Jeff Doolittle
Ray Favreau, Chris Dougan, Heather Oatis, Kevin Cooney, Tony Manfre,
John Caldwell, Andrea Confrancesco,_Chris Duchesne, Vincent Stetson
FROM: Michele Lipe, AICP, Director of Planning
The Planning & Engineering Departments have received plans for the following projects:
Appl 19-05P,NuWay Tobacco Site Plan Minor Modification
Location: 200 Sullivan Ave
® Site Plan ❑ Subdivision No. Acres 9.8 Zone I
❑ Industrial ® Commercial ❑ Residential No. Lots/Units
Water: ® Public ❑ Private Well Sewerage: ® Public ❑ Septic System
Project Description: 1,250 sf farm tek storage building behind existing building
Future Town-owned property involved? ❑ Yes ® No
❑ new street(s) ❑ new detention area
❑ new open space/recreation area ❑ active ❑passive
Planning Department notes:
Please comment by 2./1/19 and return to the Planning Department.
SOWN Sf4
O
c �
s �
7_aa� O-P S_0� ?d&U&Ot
1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074
SOR'CO TELEPHONE (860) 644-2511
CERTIFIED MAIL 70171450 0001 3280 5846
January 28, 2019
NuWay Tobacco
David Fresk
200 Sullivan Avenue
South Windsor, CT 06074
Dear Mr. Fresk:
Re: Appl. 19-05P,NuWay Tobacco —site plan modification, for a 1,250 sf storage building
We are pleased to advise you that your request for a minor site plan modification has been
approved. This approval is for a 1,250 sf storage building, on property located at 200 Sullivan
Avenue, I zone, as shown on plans prepared by Design Professionals, Inc., Project No. 2829,
dated January 9, 2019 as revised. This approval is subject to the following modifications:
1. No building permit will be issued until the final mylars have been filed in the Town Clerk's
office.
2. An as-built plan is required prior to issuance of a Certificate of Occupancy per Section 9.1.3
of the Zoning Regulations.
3. All plans used in the field by the developer must bear the stamp and authorized signature of
the Town of South Windsor.
4. The building street number must be included on the final plan.
Three print copies of the entire set of plans with live signatures and raised seals must be
submitted to this Commission to be stamped and signed.
Sincerely,
Y
Michele Lipe, AICP
Director of Planning
MRL/llz
Cc: Town Engineer
Chief Building Official
Assessor