HomeMy WebLinkAbout2164 Ellington Road - WPCA Application & Approval Letter SOW N Sf4
O-P S-o-� ?d&U&Ot
w� 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074
son•co`'`� TELEPHONE(860) 644-2511
June 12, 2017
Mr. James Marino
Marino Construction, LLC
41 Smith Street
East Hampton, CT 06424
Re: 2164 Ellington Road
WPCA Approval
Dear Mr. Marino:
The South Windsor Water Pollution Control Authority, at its regular meeting of June 6, 2017,
approved the application as presented for connection to the Town's sewerage system for a proposed
residential home at 2164 Ellington Road, South Windsor, CT as more specifically shown on plans
entitled "Site Improvement Location Plan, Proposed Lot 91B, Prepared for Zheng Li Kwok, 2164
Ellington Road, South Windsor, CT); Prepared by Joel M. Fuller, Marlborough, CT; Dated March 5,
2017; Revised: 6/05/2017. This approval is subject to the following conditions:
1. Technical approval of the Town of South Windsor Engineering Department; and
2. Final Authority approval and acceptance of the sanitary sewerage connection will be
conditional upon the installed sewer line having been inspected by the Town staff, and upon the
written verification of the Town staff that said sanitary sewer line was installed in substantial
conformance with the design plans approved by the Authority, and meeting all regulations and
appropriate technical specifications relating to sanitary sewer construction.
This approval letter must be superimposed on the final approval plans.
Very truly yours,
Anthony E. Manfre
Superintendent of Pollution Control
cc: Richard Aries, Chairman
Michael J. Gantick,Director of Public Works
Jeff Doolittle, Assistant Director of Public Works/Town Engineer
Michele Lipe, Director of Planning
Chris Dougan, Chief Building Inspector
TOWN OF SOUTH WINDSOR RECEIVED
WATER POLLUTION CONTROL AUTHORITY
APPLICATION FORM MAY 0 3 2017
Application No.: TOM OF SOUTH VONDSOR
Date Received
Date Scheduled For
Applicant E
(ryl A% o
Address
Telephone No. U "
Owner of Record on Land Records : �,. ? J
Owner's Address ' '4-' A - 4y e
Property Description: /
Assessor's Map # Parcel# _Vol. (1 Page
Project Title:
Inquiries to be Directed to: (Name,Address,Telephone No.)
Approvals Previously Received(Check) IWA P&Z ZBA
Purpose of Application: (Check all that apply)
1. Sewer Extension/Connection- -Residential Use
a. Subdivision
b. Single Unit
c. Other Explain
d. Type of Approval: Concept Final
2. Sewer Extension/Connection- - Industrial/Commercial User
a. New Connection
b. Request to Increase Flow Rate
c. Change in Nature of Waste Discharge
d. Other Explain
e. Type of Approval: Concept Final
3. Appeal of Sewer User Charge
a. Residential
b. Industrial/Commercial
4. Sewer Assessment
a. Establish Sewer Assessment
b. Appeal of Sewer Assessment
c. Change in Use of Property
5. Regulatory Appeal , Explain
6. Other _Explain
Applicant' IS' nature Date
0//
7
Owner's Signature Date
(See Reverse Side for Application Submittal Procedures)
Page 1 of 1
Manfre, Anthony
From: Doolittle, Jeffrey
Sent: Wednesday, May 31, 2017 3:32 PM
To: Diaz, Ether; Manfre, Anthony
Cc: Lipe, Michele
Subject: 2164 Ellington Road proposed House Sewer
Tony, Ether,
have reviewed the proposed plan for a new house at 2164 Ellington Road (Lot 91 B), dated March 5, 2017 and I
have the following comments:
1. The sanitary sewer lateral has to have a minimum slope of 2%from the house to the main line stub. The
proposed sewer is steeper than 2% and can be flattened.
2. The sanitary sewer lateral needs to be labeled 6" PVC SDR 35 or 6" Schedule 40 pipe.
3. Show a proposed water line from the main in the street to the house. The sanitary sewer lateral and water
line need to have at least 10 feet horizontal separating distance between them per the CT public health
code.
4. All electric, cable and phone lines need to be buried underground from the street to the house.
Let me know if you have any questions.
Thanks
Jeffrey Doolittle, P.E.
Town Engineer
1540 Sullivan Avenue
South Windsor, CT 06074
860-644-2511 x 245
jeffrey.doolittle@southwindsor.org