Loading...
HomeMy WebLinkAbout2164 Ellington Road - WPCA Application & Approval Letter SOW N Sf4 O-P S-o-� ?d&U&Ot w� 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074 son•co`'`� TELEPHONE(860) 644-2511 June 12, 2017 Mr. James Marino Marino Construction, LLC 41 Smith Street East Hampton, CT 06424 Re: 2164 Ellington Road WPCA Approval Dear Mr. Marino: The South Windsor Water Pollution Control Authority, at its regular meeting of June 6, 2017, approved the application as presented for connection to the Town's sewerage system for a proposed residential home at 2164 Ellington Road, South Windsor, CT as more specifically shown on plans entitled "Site Improvement Location Plan, Proposed Lot 91B, Prepared for Zheng Li Kwok, 2164 Ellington Road, South Windsor, CT); Prepared by Joel M. Fuller, Marlborough, CT; Dated March 5, 2017; Revised: 6/05/2017. This approval is subject to the following conditions: 1. Technical approval of the Town of South Windsor Engineering Department; and 2. Final Authority approval and acceptance of the sanitary sewerage connection will be conditional upon the installed sewer line having been inspected by the Town staff, and upon the written verification of the Town staff that said sanitary sewer line was installed in substantial conformance with the design plans approved by the Authority, and meeting all regulations and appropriate technical specifications relating to sanitary sewer construction. This approval letter must be superimposed on the final approval plans. Very truly yours, Anthony E. Manfre Superintendent of Pollution Control cc: Richard Aries, Chairman Michael J. Gantick,Director of Public Works Jeff Doolittle, Assistant Director of Public Works/Town Engineer Michele Lipe, Director of Planning Chris Dougan, Chief Building Inspector TOWN OF SOUTH WINDSOR RECEIVED WATER POLLUTION CONTROL AUTHORITY APPLICATION FORM MAY 0 3 2017 Application No.: TOM OF SOUTH VONDSOR Date Received Date Scheduled For Applicant E (ryl A% o Address Telephone No. U " Owner of Record on Land Records : �,. ? J Owner's Address ' '4-' A - 4y e Property Description: / Assessor's Map # Parcel# _Vol. (1 Page Project Title: Inquiries to be Directed to: (Name,Address,Telephone No.) Approvals Previously Received(Check) IWA P&Z ZBA Purpose of Application: (Check all that apply) 1. Sewer Extension/Connection- -Residential Use a. Subdivision b. Single Unit c. Other Explain d. Type of Approval: Concept Final 2. Sewer Extension/Connection- - Industrial/Commercial User a. New Connection b. Request to Increase Flow Rate c. Change in Nature of Waste Discharge d. Other Explain e. Type of Approval: Concept Final 3. Appeal of Sewer User Charge a. Residential b. Industrial/Commercial 4. Sewer Assessment a. Establish Sewer Assessment b. Appeal of Sewer Assessment c. Change in Use of Property 5. Regulatory Appeal , Explain 6. Other _Explain Applicant' IS' nature Date 0// 7 Owner's Signature Date (See Reverse Side for Application Submittal Procedures) Page 1 of 1 Manfre, Anthony From: Doolittle, Jeffrey Sent: Wednesday, May 31, 2017 3:32 PM To: Diaz, Ether; Manfre, Anthony Cc: Lipe, Michele Subject: 2164 Ellington Road proposed House Sewer Tony, Ether, have reviewed the proposed plan for a new house at 2164 Ellington Road (Lot 91 B), dated March 5, 2017 and I have the following comments: 1. The sanitary sewer lateral has to have a minimum slope of 2%from the house to the main line stub. The proposed sewer is steeper than 2% and can be flattened. 2. The sanitary sewer lateral needs to be labeled 6" PVC SDR 35 or 6" Schedule 40 pipe. 3. Show a proposed water line from the main in the street to the house. The sanitary sewer lateral and water line need to have at least 10 feet horizontal separating distance between them per the CT public health code. 4. All electric, cable and phone lines need to be buried underground from the street to the house. Let me know if you have any questions. Thanks Jeffrey Doolittle, P.E. Town Engineer 1540 Sullivan Avenue South Windsor, CT 06074 860-644-2511 x 245 jeffrey.doolittle@southwindsor.org 5/31/2017