Loading...
HomeMy WebLinkAboutApplication 10&apos; X 12&apos; Shed (5) ZONING COMPLIANCE FOR SMALL STRUCTURES (Sheds and detached decks 200 sq. ft. and smaller) Address of Proposed Structure: 97 FcLzer- F'c /20ad Zone: tiRROS Name of Owner: Jubmid Sdi wac---" GIS PIN: 39 13 018-7 Phone Number: 833 - SONZ Application #: 1. Name of Applicant: i✓CLV i d ScA Address: .-Y7 F—r-c-zec F'r- Foa, � � �✓� c s�>�; 0(o Phone Number: (66c)) 933 _ 5-9q Z 2. Structure cannot exceed 200 square feet. ,aw�N �a TYPE OF STRUCTURE: V SHED DECK (not to exceed 30"from grade) DIMENSIONS OF PROPOSED STRUCTURE: C o x L Z- 3. A Class D survey must be submitted with the application showing the property lines, all other buildings and the location of the proposed structure. 4. Is the property served by a septic system? Yes ✓No If yes, the applicant must complete and submit a B100a Application to the Health Department for review and approval. The undersigned hereby permits Town staff to enter onto and inspect this property during reasonable hours for the purpose of reviewing this application and to determine final compliance once construction is completed. I, the undersigned, acknowledge that the above information is true to the best of my knowledge and that the above requirements are understood. Applicant Signature: ! Date: (�1-311 S Owner Signature: ��/ Date: G / Reviewed and approved by: 62U Date: 3 / Zoning Enforcement Officer Reviewed and approved by: Date: Environmental Health Officer cc: Assessor Building File 04/15/14 ,\ ?80, ?moo -------- -. % .�` N 68 \` N 144 266 ,PROPOSED YARD.DRAIN 18B v Tf= 264.2 ----- 264 =----- + v FL OUT= 260.2 .. . 262.4 RIGHT TO DRAIN (TYPICAL) 12-0 HD OPOSE�. 264.7 o I N NOTE - N / 263.4 l YARD DRAINS AND STORM DRAINAGE P/PES ' CONNECTING THE YARD DRAINS SERVE POSED YARD DRAIN f18A 5' /'264.9 PR/VATE LOTS AND WILL NOT BE MAINTAINED +++ BY THE TOWN. W & OUT= 257.8 Z 262.4 o' + 264.1 v : � +263 4 01 / + 265.3 266.1 6� 52 0.7' 2nd FLOOR STAIR ,OVERHANG Q66. L265.3 ; HATCHWAY 1 265.4 16' 267.0 267.2 33.2 24.1 DECK N 22.7' --'�<. + 267.1 I I' .WENT 35.5' i EXISTING HOUSE 04 o` ` EM (11-6:-13) d c OD BITUMINOUS CONCRETE o FD FL- 259.7* 268.57 NON w,o SAN DRIVEWAY � M . FL= 258.5t / 3'x8' COVERED 267.E , ?s� , %" a 'cM cv 3s.o'.sroOP m z2.o' 68.49:1 R=37500. ! Mi 1405 L=148.24 N L 67.65 De/fa=22;38'55" 20' WIDE STREET TREE Y266.8 �� ------ � 4.5y, 267.1! �_ IN FAVOR OF 7HE TOW c� 268.72I BRICK l BRICK �. �. If `0. 3 PAVER WALK W N�� 266.8 _TE', 265 6` 10' WIDE C.L.& P. CO. AND 10 WIDE YANKEE i ' _262'/26214e"�-G-L_ _ 08 `265,41 NMN28 ER I SP��6Lg1 4' W1DE CONCRETE WA! sEw N. I k.--'-263.98 265 �c\�'8w wA>FR MAIN . %fro ` �p R ROAD B#29 L I SAN.MH 27 FRAZGR FIR A - L_��E=_ 4.30_-----' ;261. g I Gf-2 ca #28 CAANTADV CCWCD /ATCDAI - - - - GE T1FICATION OF.ZONING CMAPLIANCE Proposed building(s), uGe(s) and/or structure(s) as shown on this plan appear(s)to be ii�7 confo:rrea;Ice with current South Windsor regulations. Variances and special exceptions may apply. ®ate 3 / rA Zoning Enforcement Officer l J`F I L .s k,of