HomeMy WebLinkAboutWPCA 765 Sullivan Avenue (3) SOW N Sf4 -0� O-P sloam V&U&O't 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074 �if�OsoR.co TELEPHONE (860) 644 2511 February 19, 2015 Steve Palauskas 136 Trombley Road East Windsor, CT 06088 RE: Connecticut Valley Brewing Co., 765 Sullivan Avenue - WPCA Approval Dear Mr. Palauskas: Motion was made to approve the application as presented for connection to the Town's sewerage system for a proposed commercial building located at 765 Sullivan Avenue, South Windsor, CT and as more specifically shown on plans entitled "Connecticut Valley Brewing, Co., 765 Sullivan Avenue, South Windsor, CT"; prepared by JR Russo & Associates, LLC.; Project No.: 2014-001; dated 11-17-14; Sheet 7 of 10 "Utility Plan" and Sheet 9 of 10 "Detail Sheet". This approval is subject to the following conditions: 1. There will be a monitoring manhole on the outfall pipe installed within the street right-of-way for the purpose of monitoring B.O.D. and solids; 2. A connection charge will be due in the amount of$11,433 for 3 acres at the time of connection, the rates for which will be in effect until June 30, 2015; 3. Technical approval of the Town of South Windsor Department; and 4. Final Authority approval and acceptance of the sanitary sewerage connection will be conditional upon the installed sewer line having been inspected by the Town staff, and upon the written verification of the Town staff that said sanitary sewer line was installed in substantial conformance with the design plans approved by the Authority, and meeting all regulations and appropriate technical specifications relating to sanitary sewer construction. This approval letter must be superimposed on the final approval plans. Very truly yours, tRichar Aries, Chairman Pollution Control Authority cc: Michael J. Gantick, Director of Public Works Jeff Doolittle, Town Engineer Michele Lipe, Town Planner Chris Dougan, Chief Building Inspector TOWN OF SOUTH WINDSOR WATER POLLUTION CONTROL AUTHORITY APPLICATION FORM Application No.: Date Received Date Scheduled F r 3 Applicant Connecticut Valley Brewing Co. Address 765 Sullivan Ave Telephone No.: 860 729-6408 - Owner of Record on Land Records Town of South Windsor Owner's Address Property Description: Assessor's Map# Parcel#_... _ Vol. 2015 Page 221 Project Title: Inquiries to be Directed to: (Nate,Address,Telephone No.) Steve Palauskas 136 Trombiey Road East Windsor,CT 05088(860)729-6408 Approvals Previously Received (Check) IWA x P&.Z x ZBA Purpose of Application: (Check all that apply) 1. Sewer Extension/Connection-- Residential Use a. Subdivision b. Single Unit c. Other. .. ._...._ Explain d. Type of Approval: Concept Final 2, Sewer Extension/Connection--Industrial/Commercial User a. New Connection 'x b. Request to Increase Flow Rate c. Change in Nature of Waste Discharge d. Other Explain e. Type of Approval: Concept Final..._x 3. Appeal of Sewer User Charge a. Residential b, Industrial/Commercial 4. Sewer Assessment a. Establish Sewer Assessment b. Appeal of Sewer Assessment _ c. Change.in Use of Property_,____ 5. Regulatory Appeal ,Explain 5. Other Explain Z Lw Applicant's Signature Date Owner's Signature Date "'S 1 3 r �.-,YF ry FF t . Proposal Prepared For: Connecticut Valley Brewing Company Attn: Steve Palauskas 765 Sullivan Ave South Windsor, CT 06074 Woodard Curran Attn: Michael J. Burns, P.E. 1699 King Street, Suite 406 Enfield, CT 06082 8,000 GPD HOOT MTS System Based on the information provided to us by the owner, we have chosen to recommend a 8,000 GPD Hoot MTS Series to Pre-Treat the wastewater to better than residential levels for discharge into gravity sewer. This facility is proposed to be a Brewery and the wastes generated from the facility are estimated to be approximately 1,000 to 2,500 mg/L of BOD at 1,000 gallons per day for a total of 21.0 lbs. of BOD and pH Neutral (6-9). All human wastes will be diverted around the system and directly drain into the city sewer. The system has been designed to deliver the amount of air necessary to complete digestion in %Z of the day (running 720 of 1440 minutes), and the Aeration can be increased to 100% and essentially double either the flow or the strength, or a combination there of. We assume residential strength of wastewater, which is not to exceed on average 238 on BOD5i 200 on TSS and maintain a pH of 6-9. pH adjustment, via the addition of chemicals in the main drain along with Anti-Foaming agents or microbes to encourage digestion may be required, and are in addition to this proposal, if necessary. Hoot Systems, LLC. 2885 Highway 14 East Lake Charles, LA 70607 Hoot/CT Valley Brewing January 20, 2015 Page 2 of 4 Grease Trap/Trash Trap: • The first compartment (1,000 gallons) of a Heavy Duty 2,000 Gallon tank will be used for settling of Solids, and provide for separation of Grease as the first compartment of the Pre-Treatment tank. • A PL-625 Solids Filter from Polylok of Wallingford, CT with High Water Alarm Package. Equalization Tank: • 1,000 Gallon Pre-Cast Tank as the 2nd compartment of the 2 compartment tank • Troy Air H-820 Blower and coarse air diffuser bar to deliver air to mix the waste and begin the treatment process. • Blower Control Panel — o 96 pin Cycle timer will be provided to time EQ air delivery • All piping for Simplex Aeration and Duplex Meter Dosed Pumping. • Charcoal Filtered Vent Cover. • Cast Iron Ring and covers brought to grade on Concrete Risers over the openings (24" on Inlet and Filter, 30" over the pumps.) • Stilling Well for Float switches • Two, 2" Solids Transfer pumps (Gould's WW511) for duplex equalization. • Rhombus IFS Meter Dosing Pump Control Panel — o NEMA U Duplex Control Panel, Single Phase, 120 Volt • 3" Sleeve for Electrical Pass Through and 8"x8" junction Box Aeration Chamber Packages Includes: • 3,000, 5,000 or 8,000 Gallons of Aeration Chambers, in 2 Castings. The Second casting (MTS 1) will contain the clarifier. • 60"x60" Aluminum Pedestrian Rated (300 lbs. per square foot) to cover openings on treatment plant. • Fine Air Diffuser assembly package. Hoot Systems, LLC. 2885 Highway 14 East Lake Charles, LA 70607 Hoot/CT Valley Brewing January 20, 2015 Page 3 of 4 Aeration Chamber Packages (Continued): • Polylok Charcoal Filtered Vent Cover • Miscellaneous mounting hardware, boots and clamps kit. • Blower Package Includes o Duplex URAI-24 blowers with 1.5 HP motors o Blower Frame with S.S. Hardware with Aluminum housing. o NEMA 4 X, duplex control panel, Single phase, 230 volt. • Blower & Systems Controls Include o NEMA 4 X, Duplex Control Panel, Single Phase, 230 volt. Clarifier • 5,000 GPD Rated Clarifier. • Aluminum Double Weir Trough & Baffle. • Aluminum Baffled Stilling Well. • 30"x72" Aluminum Pedestrian Rated (300 lbs. per square foot) • 3" Air Lift Return Activated Sludge Line. • 2" Air Lift Adjustable Surface Skimmer and Return Line. • Valving to control return flow rate and air delivery. Other Items • Aluminum and Galvanized Panel Rack and with load Center • 3 Days factory trained professional time for assistance (providing direction for install) is included in the purchase price of the system. Estimated Projected Total (Excluding any Taxes): $60,000.00 Refundable Deposit Due to complete design and drawings: $6,000.00 Hoot Systems, LLC. 2885 Highway 14 East Lake Charles, LA 70607 Hoot/CT Valley Brewing January 20, 2015 Page 4of4 From this Bid, if accepted, a full contract will be developed. Prior to release of final submittal documents and drawings to the DEP for approval, a deposit of 10% ($6,000) of the projected cost is required to complete the work. The final price will be determined by any additional components that are required to obtain the permit, as required by either the engineer or the local or State Health Department/DEP. From that final price, a contract will be developed. Please Note: • You will need to provide a CT licensed Installer to complete this project. They will need to be present, onsite, each day that construction takes place and be responsible for the installation. They will be responsible for the excavation, setting of tanks including crane, installation, hook-up of drain lines to the first tank and from the Clarifier of the Hoot Tanks to the city sewer line. • Any watertight testing required and the lines to and from the system are the responsibility of the owner. • You will need to employ a licensed Maintenance provider for the lifetime of the treatment system. • We will work with your engineer to provide the required drawings, documents and any additional information required, and attend meetings with them or the State or L.H. Department, if needed. • No excavation work is included with this bid. • No setting of tanks by a crane is included, only delivered in Full truck load quantities to the site. (Crane rental responsibility of Installer) • No electrical work or supply is included, other than supply of components listed above (listed pumps, motors, load center, etc.) • Plumbing to the system from the structures and between final tank and the city drain line is not included. • No permit (s) (construction, impact, environmental or otherwise) are included. • We recommend a fence around the system, but it is not included. Hoot Systems, LLC. 2885 Highway 14 East Lake Charles, LA 70607 South Windsor Calculations @ 1,000 GPD CFM Calculatio ns ppm Gallons Rate Lbs Lbs of BODs/D 2,500 1,000 0.00000834 20.9 OZ rate per Total Lbs Lb Lbs Needed 02 Needed per lb of BOD 1.8 20.9 37.5 lbs of 02 Needed 37.5 Cubic Feet of Air Needed (58.2 CF= 1 lb of 02) 2,184.2 CFM Needed @ 100% uptake at 720 min 3.0 effiency of uptake with Fine Air Diffusion (20%) 15.2 Additional Air Needed for Air Lift 10.0 Total CFM Needed 25.2 Basin Sizing Calculations VA= (BOD x Q x 8.34)/BLF VA=Volume of Aeration Basin in 1000 ft 3 BOD Loading in ppm Q= Influent Flow in MGD BLF= BOD Loading Factor of 20 ppm of BOD 2,500 Gallons 1,000 Cubic Feet Needed at 20 BLF 1,042.5 7,797.9 Recommended Basin Size in Gallons 8,000 Diffuser Requirement Calculations CFM 15.2 Rate Per Diffuser 2.5 Total Diffusers 6 ..��lulrs .us i ■ . , �7� �� 1111 'ala ''����1••u,:;r:iiGii�lnl�uj .I -- nwXn III I I * i - �u •��r I II -- - it • • [a�il�u: �• ��� ci1,111 - l :� 1 .. ........................ . HOOT SYSTEMS STEMS LLC - - ................::::......... . WNAINYM.11 1.D U A 0 1 Z 1 j Eo .. CT _ . . CT— HOOT . . .. 3"SCH 40 COUPLING I I I I �_ 8.00 0 I 6.00 I 5.00 � I I I II I I I I I II I II I III I I LJ I I II I III I I I I I II LJII I I I I I n n I I I I I 79.00 I 61.00 I I I I I I I I I I I 6a.00 I I I I I I I II II I I I I I I I I i I I I kAAA AA L-------- I I II I I I I II I I I L-- ----J �--— ----------J -- — J �600 FRONT VIEW SIDE VIEW 121.00 1 s.00 14.00 I —_ -__ ___ — 16.00 O O INLET II I OUTLETS 16.00 TO + LET 4'IN AERATION r TANK I •{}• II I 024.00 I I 030.00 I I I 85.00 I II II I II 3'CONDIUT 030.00 II I I II II I I I6'0 I I I II II I O O HOOT SYSTEMS LLC I II II I 36.00 I I I OLYLOK II I I I I 22.00 EFFLUEENf I I I Fl-= THIS DRAWING IS THE PROPRIETARY PROPERTY OF HOOT SYSTEMS LLC. REPRODUCTION, DISCLOSURE OR USE OF ANY PART OF THIS DRAWING OR ANY INFORMATION THEREIN IS —— ———— ———————————— EXPRESSLY PROHIBITED WITHOUT PRIOR WRITTEN CONSENT OF HOOT SYSTEMS LLC. DESCRIPTION. PART$ TOP VIEW CT VALLEY BREWING CO. - S WINDSOR, CT HOOT GREASE TRAP/ TT/EQ TANK DATE: DRAWN BY. CNECIL BY: MILE: GREASE & TRAS H 01-20-2015 AY RS N.T.S. TRAP & EQ 8. ------------- ' ----------�aII6'.sa ( 9.38 / ---- 54.00 54.00 i 43.00 I I I I -------- I I I I 82.00 I 82.00 'Z°° arHaHaararioarraoraioiarai raiararoaaaHrHiHiaiaiaiHi ��o����o�om�n�o��ooaoo���� I rHHr./////Il/raHa/ai/II!/HHr HmHmruHrHHr/H//aHr �v���� ���----��o�u 1200 .50 I ,w/war µwTa.q I 20.00 a00 J_ 8.00 FRONT VIEW —� 600 204.00 SIDE VIEW 192.00 12.00 90.00 ,z.o0 3.00 72.00 84.00 HOOT SYSTEMS LLC I I I 024.00 ' _- ______ Moo THIS DRAWING IS THE PROPRIETARY PROPERTY OF HOOT SYSTEMS LLC. REPRODUCTION, L ————————————————— _ J DISCLOSURE OR USE OF ANY PART OF THIS DRAWING OR ANY INFORMATION THEREIN IS fioo EXPRESSLY PROHIBITED WITHOUT PRIOR WRITTEN CONSENT OF HOOT SYSTEMS LLC. DESCRIPTION: PART# 16.00 CT VALLEY BREWING CO. — S WINDSOR, CT PLAN VIEW HOOT 8K MTS — AERATION 2 DATE: DR DW BY. CHECK BY. SCALE. AERATION 01-20-2015 1 AY IRS N.T.S. 2 i 6Oo 6es 14.00 8.869.38 11 18.42 0.50 I 54.00 I 19.00 I I I I I I I FROM O IFROMI I 8200 I // /////////// ///////////// 1 T- / moo FIRE 606PA.E DPFusERs w 54.50 / 11T// I `'i 24.00 rk- 6.00 L FRONT VIEW 204.00 RIGHT SIDE 1 iz.00 192.00 3 00 84.75 12.00 6.O0 Y'�� Y AIR ME fROM CLARIFIER 6'DNMEIER ———————— ° T 1RASFER PPE 7.25 ------- 24.00 -- 30.00 I 16.00 / I aw 91fMIMER k P-1ItM I I r/6ERNCE PORT 72.00 3,SLUDGE 84.DO FROM \ I CE 24k7Y I wxFss Fum \ • . HOOT SY STEMS LLC 6.00 6.00 33.00 THIS DRAWING IS THE PROPRIETARY PROPERTY OF HOOT SYSTEMS LLC. REPRODUCTION, DISCLOSURE OR USE OF ANY PART OF THIS DRAWING OR ANY INFORMATION THEREIN IS PLAN VIEW EXPRESSLY PROHIBITED WITHOUT PRIOR WRITTEN CONSENT OF HOOT SYSTEMS LLC. DESCRIPTION. PART M CT VALLEY BREWING CO. - S WINDSOR, CT MTS AERATION 1 + CLARIFIER DATE. DRAAN BY. CHECK BY. SCALE: MTS 1 1-20-2015 AY IRS N.T.S. CLARIFIER