Loading...
HomeMy WebLinkAboutApp 14-09P Evergreen Walk General Plan TOWN OF SOUTH WINDSOR rFEB CEIVE® ^_ PLANNING&ZONING COMMISSION APPLICATION FORM [Application Number: l —OQ(' sa Official Receipt Date: / SOUTH WINDSOR PLANNING DEPT, Munis Application 4: APPLICANT: . Evergreen Walk LLC PROJECT NAME: Evergreen Walk COMPLETE LOCATION OF PROPERTY: West side of Buckland Road OWNER OF RECORD ON LAND RECORDS: _ Evergreen Walk LLC _ OWNER ADDRESS: c/o Laurence Rubinow, City place, Hartford, CT_ 06103 GIS PIN : 15300151 _ ZONE GDZ NAME, ADDRESS, TELEPHONE &EMAIL ADDRESS OF PERSON TO WHOM INQUIRIES SHOULD BE DIRECTED: Alan F. Lamson FLB Architecture & Planning, Inc 19 Silver Lane, East Hartford, CT 06118 -alamson@flbarch.com. (860)568-4030 Estimated presentation time:30 min. THIS APPLICATION IS FOR: (Check all that apply): ❑ Zone Change to__(public Hearing and Certificate of Mailin __________ $ Required) ❑ Open Space Subdivision/Resubdivision (Public Hearing and Certificate of Mad- El ng Required) Subdivision ❑ Minor ❑ Major ❑ Resubdivision (Public Hearing Required) [] Minor ❑ Major ❑ Conditional Subdivision ❑ Special Exception to Table_ (public Hearin and Certificate of Mailing $ $Required) ❑ Site Plan of Development ❑ New ❑ Modification Building(s) Sq Ft_ General Plan of Development ❑ Dept of Motor Vehicle License-State Hearing per Section 1 4-55 for ❑ Earth Filling(Sec. 7.6) and/or Earth Removal(Sec. 7.16) (Public Hearing and Certificate of Mailin Re El Regulation Amendment ElZonin $ quired) $ ❑ Subdivision-Attach proposed amendment(Public Hearing Required) ❑ Temporary and Conditional Permit (Public Hearin and Certificate of Mailing $ g Required) For ❑ Temporary and Conditional Permit Renewal (Certificate of Mailing Required) for ❑ Detached In Law Apartment or❑Accessory Apartment(Public Hearing and Certificate of Mailin Re El Major Home Occupation (Certificate of Mailin$Required) for R $ �) ❑ Other (explain in detail) -`---- *An Application Pending Sign is required to be posted on the property for all applications ten(10) days prior to being heard by the Commissio Signature of Applicant John Finguerra, Member ti'n ingueixa,y4 e Evergreen Walk, LLC ,ein�ier Evergreen Walk, LLC RECEIVED FEB 2 4 2014 SOUTH WINDSOR PLANNING DEPT. iL FLB Architecture & Planning, Inc. 19 Silver Lane East Hartford CT 06118 (860)568-4030 fax: (860)568-5129 e-mail:flb@flbarch.com web:www.fibarch.com LETTER OF TRANSMITTAL P:\99508.00\General Plan Of Development 2014\ML 140220 Appl For Date 2/20/14 Project No. 99508.00 GPD.Doc Attention To: Michele Lipe, Town Planner Pro ect General Plan of Development Town of South Windsor Evergreen Walk South Windsor, CT We are sending you x Attached ❑ Under separate cover via the following items: x Prints ❑ Copy of letter ❑ Shop drawings ❑ Original tracings ❑ Copy of memo ❑ Samples ❑ Specifications ❑ Change order proposal request ❑ Code modification request ❑ Request for Payment ❑ Change order x Other as described below Item no. Copies Date No. Description 1 2 Application Form for General Plan of Development 2 1 2/20/14 14715 Application Fee in the amount of$385.00 3 3 2/19/14 URS Traffic Impact Study letter 4 3 2/20/14 F&O Utility Impact Stud 5 3 2/20/14 Z-1 to Z-3 FLB Master Plan—General Plan of Development THESE ARE TRANSMITTED as checked below: ❑ As requested ❑ Approved ❑ Resubmit copies for approval ❑ For your use ❑ Furnish as corrected ❑ Submit copies to distribute ❑ For review ❑ Rejected ❑ Return corrected prints &comment ❑ Submit specific item ❑ x For approval ❑ For bids due ❑ Prints returned after loan to us Remarks: Submitted for reapproval of General Plan of Development. There are no changes in land use type or amount of proposed building from t he last ame ed General Plan of Development approved b the Planning and Zoning Commission. Copy to: file Alan F. Lamson, AIA, AICP ff enclosures are not as noted,kindly notify us at once. ECEIVED FEB 2 4 2U14 February 19, 2014 SOUTH WINDSOR PLANNING DEPT. Mr.John Finguerra Evergreen Walk, LLC 1109 Rose Lane Virginia Beach VA 23451 RE: Evergreen Walk General Plan of Development South Windsor,Connecticut URS File: 36938654 Dear Mr. Finguerra: Pursuant to your request,we have reviewed the Traffic Impact Study that was prepared by FA Hesketh&Associates,Inc. under my direction as part of the application to the Town of South Windsor for approval of the General Plan of Development for the Expansion of the original development. This report, dated June 13, 2007 was also submitted to the State Traffic Commission —STC(now known as the Office of State Traffic Administration-OSTA), as part of an application to amend STC Certificate No. 1533 that was approved in February 2002. The Traffic Impact Study was based on a proposed expansion of Evergreen Walk from a previously approved total square footage of 1,230,00 square feet to a new total of 1,780,000 square feet. This change included the following land use changes: • Retail increase from 375,000 SF to 725,000 SF • Residential to be added as a new use, at 200 units • Indoor recreational to remain unchanged at 75,000 SF • Hotel to remain unchanged at 250 Rooms • Office to be decreased from 650,000 SF to 550,000 SF The proposed modification was projected to increase traffic generated by the site by 1178 vehicles (571 entering and 607 leaving) during the afternoon peak hour, and 1350 vehicles(717 entering and 632 leaving)during the Saturday mid-day peak hour. The total site generated traffic(after the expansion)was projected to be 3202 vehicles during the afternoon morning peak hour,and 33274 vehicles during the Saturday mid-day peak hour. This new traffic was divided between the 4 existing site drives—one unsignalized drive to Deming Street and three signalized drives to Buckland Road. In order to maintain good operations in the corridor, improvements have been proposed at two intersections: 500 Enterprise Drive,Suite 3B •Rocky Hill,CT 06067 • (860)529-8882 • Fax(860)529-3991 Mr. John Finguerra February 19, 2014 Page 2 • Buckland Road and Tamarack Drive—It was proposed to widen Buckland Road to provide a dual left turn for northbound traffic. Design plans for this improvement have already been approved by the Town. • Buckland Street and I-84 Eastbound Exit Ramp—It was proposed to widen the intersection to provide geometry to accommodate three left turn lanes for ramp traffic turning onto Buckland Street Northbound. With the improvements noted, all intersections in the vicinity of the site were expected to operate at LOS D or better during the peak hours. As a result,the STC approved the Certificate modifications, and the Town approved the revised General Plan. We have reviewed the report, and it is our professional opinion that the traffic impact report prepared for the original General Plan application correctly reflects the traffic generation that can be anticipated from the project. The analyses should,therefore,be accurate, and the proposed improvements should adequately mitigate any impacts from site generated traffic. We conclude that the results indicated in the original report are still applicable and sound. Very truly yours, URS CORPORATION AES `���`•�® cONd 'f"t "/" Steph n F. Mitchell,P.E. Z #13321 Highway/Traffic Engineering Manager' s hill i1 (860)990-6755 (Direct) Utility Impact Statement For Evergreen Walk South Windsor, Connecticut June 18, 2001 Revised July 9, 2007 Revised February 21, 2014 Developer: Evergreen Walk Associates,LLC c/o John Finguerra 1109 Rose Lane Virginia Beach,VA 23451 FUSS&O'NEILL Disciplines to Deliver Engineer: Civil and Environmental Fuss & O'Neill 146 Hartford Road Manchester, CT 06040 Project No. 2000-481-A68 RECEIVED FEB 2 4 20114 SOUTH WINDSOR PLANNING DEPT. 3 FUSS&O'NEILL UTILITY IMPACT STATEMENT FOR EVERGREEN WALK SOUTH WINDSOR, CONNECTICUT SECTION PAGE I. INTRODUCTION.................................................................................................... 1 A. Purpose and Scope.............................................................:.............................. 1 B. Site Location..................................................................................................... 1 C. Project Description........................................................................................... 1 A. Projected Public Water Supply Requirements ...................................................2 B. Existing Water System......................................................................................2 C. Proposed Improvements................................................................................... 3 D. Conclusion........................................................................................................ 3 III. SANITARY SEWERS............................................................................................... 3 A. Projected Sewage Flows from Proposed Project............................................... 3 B. Existing Sewerage Facilities...............................................................................4 C. Proposed Improvements................................................................................... 5 D. Conclusion........................................................................................................ 5 IV. STORMWATER MANAGEMENT........................................................................ 5 A. Existing Conditions .......................................................................................... 5 B. Proposed Detention and Storm Sewer System.................................................. 5 A. Electric Power.................................................................................................. 6 B. Gas................................................................................................................... 6 C. Communications............................................................................................... 6 EXHIBITS 1. Site Location Plan 2. Water Supply Exhibit 3. Sanitary Sewer Exhibit \\I IQFS1\SYS\P2000\481\A68\UTILITIES\U1'IL IMPACT'S"PATEMEN'1'\UTILI'I'YREPOR'I'_2014-02-18.DOC Corres.(HQ) 1 FUSS&O'NEILL I. INTRODUCTION A. Purpose and Scope This Utility Impact Statement has been prepared in accordance with the most current revisions to the Town of South Windsor Zoning Regulations. Its purpose is to define,in a general way, the projected impact that the proposed land uses and intensities will have on the Town's infrastructure,with particular emphasis on: 1. Water supply and distribution system 2. Sanitary sewers 3. Stormwater management B. Site Location The development site is located in the south central part of the Town of South Windsor north of the Manchester town line. It is approximately 243 acres in size and is generally bounded on the north by Deming Street, on the east by Buckland Road, on the south by Smith Street and on the west by Plum Gulley Brook (Exhibit 1). On-site existing topographic elevations range from 70 to 150 feet above mean sea level. The major roadway network that will provide primary access to this project has been reviewed and is further discussed in a separate Traffic Impact Study. C. Project Description The 243 acre site has been used for farming for many years. Currently,The Shoppes at Evergreen Walk, a retail center; ECHN, a medical office building, and LA Fitness, an indoor recreation center, have been constructed. Since the previous report, additional medical office buildings, ECHN II, have been constructed south of the existing ECHN building on Tamarack Avenue. Additional projects are in various stages of construction or approval,including the hotel and residential units,west of The Shoppes. The proposed revised Evergreen Walk project anticipates the following development: TABLE 1 Land Use Proposed Size Hotel 250 rooms Indoor recreation 75,000 SF Office 550,000 SF Retail 725,000 SF Residential 200 units The location of Evergreen Walk is shown on the accompanying Location Plan (Exhibit 1). The utilities necessary to support the proposed development area \\HQFS1\SYS\P2000\481\A68\UTILI'I'IES\UTIL IMPACT S'I'ATEMEN'1'\UTILI'I'YREPORT 2014-02-18.DOC Corres.(HQ) l FUSS&O'NEILL are shown on Exhibit 2 (Water Supply) and Exhibit 3 (Sanitary Sewer). The storm drainage watershed for the site is shown on Exhibit 1. II. WATER SUPPLY A. Projected Public Water Supply Requirements Based on the table of uses indicated in Table 1 and as shown on the Land Use Study, a projection of domestic water requirements was prepared. This projection is detailed in Table 2 below: TABLE 2 Peak Daily Peak Hourly Land Use Unit Flow Average Daily Flow ) Flow(2) Description Size(S.F.) (Gal/Day) Flow(Gal) (Gal) (Gal/Min) Office 550,000 0.11/S.F. 60,500 121,000 242,000 Hotel 250 Rms 150/Rm 37,500 75,000 150,000 Indoor 75,000 0.15/S.F. 11,250 22,500 45,000 Recreation Retail 725,000 0.10/S.F. 72,500 145,000 290,000 Residential 200 150/Rm 45,000 90,000 180,000 Units/300 rooms (1)Peak daily flow is 2.0 times the flow demand for an average day. (2)The peak hour demand is 2.0 times the peak daily flow rate. In accordance with the usual and customary practice, the tabulated flows must be available for usage at residual pressures in the ranging from a low of 25 pounds per square inch to a maximum of about 110 pounds per square inch. Requirements for water for fire protection purposes were determined based on the proposed development. Relative to retail areas, current standards indicate that a fire flow of 2,000 to 3,000 gpm at a 25 psi minimum residual pressure for up to a three hour period may be required. As necessary, flow tests and calculations will be performed for the various phases to confirm adequate fire flow service. B. Existing Water System The existing public water system is owned by the Connecticut Water Company (CWC). The system is operated by the CWC Northern Division,with offices at 25 North Road, East Windsor, CT 06088. A 12 inch water main fronts the site on three sides,Deming Street on the north,Buckland Road on the east, and Smith Street on the south (Exhibit 2). \\I-IQFS1\SYS\P2000\481\A68\UTILITIES\UTIL IMPACT S1'ATEMENT\U'1'ILITY1tEPOWI'_2014-02-18.DOC Corres.(HQ) 2 FUSS&O'NEILL A fire flow test conducted by the CWC on October 23, 2006 at a hydrant on Buckland Road yielded a flow of 1,135 gallons per minute (gpm) with a residual pressure of 70 pounds per square inch (psi). The static pressure was 90 psi. The hydrant tested is located near the existing Old Navy store. Additional fire flow tests were conducted by the CWC on March 11, 2008 and November 16, 2011. On March 11, 2008, the hydrant near Tamarack Avenue at Deming Street was tested and yielded 1,920 gpm with a residual pressure of 74. The static pressure was 104 psi. On November 16, 2011, the hydrant on the southern end of Tamarack Avenue near Johnny Rocket's yielded a flow of 1,404 gpm with a residual pressure of 50 psi. The static pressure was 75 psi. Additional flow tests will be conducted on the water main that is currently being installed. Results will be analyzed and coordinated with the Fire Marshal. Currently, one water main serves ECHN and the approved ECHN II. It branches off of the Deming Street water main and extends south along Tamarack Avenue toward ECHN II. The service for LA Fitness branches off of Buckland Road and extends west along Cedar Avenue. In addition, a water main branches off of Buckland Road at the southern end and extends west along Tamarack Avenue. This water line follows Evergreen Way north fora portion, splits, and then recombines and is capped near the existing Old Navy. This line serves The Shoppes at Evergreen Walk. C. Proposed Improvements Ultimately, the Tamarack Avenue extension at the north end of the site will create a loop to the Cedar Avenue stub once additional development for this area is completed. The Evergreen Way water line will also complete a loop. That configuration has not yet been determined. D. Conclusion In conclusion,it is our opinion that the existing and proposed water facilities will be adequate to provide water service for domestic and fire fighting purposes in the quantities and pressures required to support the development proposed herein. As necessary, calculations will be performed for the various phases to confirm adequate fire flow service. III. SANITARY SEWERS A. Projected Sewage Flows from Proposed Project This General Plan of Development proposes five land uses: office,hotel, recreation,retail, and residential. It is anticipated that sewage will be generated from this project in the following amounts: \\I-IQFS1\SYS\P2000\481\A68\UTILITIES\UTIL IMPACT STATEMENT\UTILIT'YREPORT_2014-02-18.DOC Corres.(HQ) 3 FUSS&O'NEILL TABLE 3 Typical Land Use Unit Flow(1) Average Daily Description Size(S.F.) (Gal/Day) Flow(Gal) Office 550,000 0.11/S.F. 60,500 Hotel 250 rooms 150/rm 37,500 Indoor Recreation 75,000 0.15/S.F. 11,250 Retail 725,000(2) 0.10/S.F. 72,500 Residential 200 units/300 rooms 150/rm 45,000 MAID units of flow were estimated from data generated by Fuss&O'Neill for similar types of establishments/uses. PIncluding restaurants The following table summarizes the total average daily flow and includes a contribution from groundwater inflow: TABLE 4 Contributing Peak Peak Design Sewage Average Daily Peak Daily Area(Acres) Infiltration(2) Flow Source Flow(Gal) Flow( ) (Gal) 243 Ac x 60% Flow(Gal) (gal/day) Project Site 226,750 907,000 146 146,000 1,053,000 (1)Assumes a Peaking Factor of 4.0 for the mixed-use development. (2)peak Infiltration=acreage x 1000 gallons/day B. Existing Sewerage Facilities The Evergreen Walk site lies within the wasteshed area of the Clark Street sewage pump station. Gravity sewers are located in Buckland Road, east of Deming Street (northern boundary of the site), Clark Street (west of the site), Wheeler Road (south of the site) and in Smith Street west of Wheeler Road (southwest of the site). The sewers from Clark Street, Smith Street, and Wheeler Road flow by gravity to the Clark Street pump station. The Buckland Road sewer flows by gravity north. ECHN currently flows by force main to the Buckland Road gravity system. In addition, ECHN II flows southerly by force main to the gravity branch located west of LA Fitness. In 1995,Weston and Sampson performed a sewer study of the Buckland Road wasteshed, and determined the most cost effective sewering plan for the wasteshed. The most cost effective sewer alignment to serve what is now the Evergreen Walk site was found to be a gravity sewer which connected to the existing sewer system on Clark Street. Such an alignment included the installation of 1,900 lineal feet of 12 inch sewer from a manhole north of the Clark Street pump station to the western property line of Evergreen Walk, generally as shown on Exhibit 3. From that point, the entire site could be served. The new alignment is in place and referred to as the Gateway Trunk \\HQFS1\SYS\P2000\481\A68\UTILITIES\UTIL IMPACT STATEMENT\UTII,ITYMPORT 2014-02-18.DOC Corres.(HQ) 4 FUSS&O'NEILL Sewer. This alignment required the crossing of wetlands and Plum Gulley Brook. Improvements to the capacity of the Clark Street pump station are not required to accommodate sewage flows anticipated by the proposed General Plan of Development. C. Proposed Improvements There are no additional off-site improvements required for the proposed Evergreen Walk development. D. Conclusion The quantity of sewage to be discharged from the uses proposed in the preliminary development plan can be adequately served by the existing Town of South Windsor sewerage facilities. IV. STORMWATER MANAGEMENT A. Existing Conditions The proposed project is situated on a parcel of land containing 243 acres located west of Buckland Road, north of Smith Street and south of Deming Street. Plum Gulley Brook runs near the westerly boundary of the project and is actually within the project area for a distance of about 2400 feet.There are two unnamed streams on the site that are tributary to Plum Gulley Brook. One of the streams runs along the southerly boundary and originates south of Smith Street. The larger stream flows west to east from Buckland Road about 2,000 feet north of Smith Street. ,This second stream,which originates on the east side of Buckland Road,joins Plum Gulley Brook within the project area. In addition to the stormwater runoff from within the project area, there are about 190 acres east of Buckland Road that drain to the project. Part of this flow is from the detention basin constructed as a part of the Lowe's/Target project. It is assumed that any future construction within the drainage area east of Buckland Road will include detention facilities that will maintain flow rates equal to existing levels. All of the stormwater runoff from the site and the area east of Buckland Road discharges to Plum Gulley Brook. A little over one mile downstream of the proposed development, Plum Gulley Brook and Whaples Brook join at Vintons Mill Pond to form the Podunk River. B. Proposed Detention and Storm Sewer System In order to minimize environmental damage and the possibility of increased runoff overloading downstream drainage facilities, stormwater best management practices (BMPs) will be utilized both during and after construction. A series of \\I-IQFS1\SYS\P2000\481\A68\UTILITIES\U"I'IL IMPACT STATEMENT\U"I'ILI'MtEPOR'T" 2014-02-18.DOC Corres.(HQ) 5 FUSS&O'NEILL sedimentation and detention basins have been and will be constructed to control sediment and peak storm flows. Infiltration of stormwater will be utilized where geologic conditions permit. During the design stage, efforts will be made to create detention and infiltration basins that are aesthetically pleasing and nuisance free. During construction, erosion control measures will be installed to minimize erosion and sedimentation. Haybale erosion checks and silt fence will be installed where needed. Sedimentation basins will be constructed when needed. In some cases, detention basins may be used as temporary sedimentation basins. All erosion control measures will be constructed in accordance with the requirements of the latest edition of Connecticut"Guidelines for Soil Erosion and Sediment Control". V. OTHER UTILITIES A. Electric Power Past discussions with officials of Connecticut Light and Power indicate that no major problems exist relative to the supply of power to the proposed site. New service to the site is and will continue to be underground. B. Gas Yankee Gas has a main line in Deming Street and Buckland Road that is adequate to serve the proposed development. The Deming Street gas line serves ECHN. The Buckland Road gas line branches off onto the southern Tamarack Avenue by The Shoppes and along Cedar Avenue south of LA Fitness. The Cedar Avenue currently branch serves LA Fitness and ECHN II. C. Communications There is adequate telephone and data service available to the proposed development. \\HQFS1\SYS\P2000\481\A68\U'I'ILI'I'IES\UTIL IMPACT STATEMENT\UTILITYREPORT_2014-02-18.DOC Corres.(HQ) 6 UCS: MS VIEW' LMAtt ICTS: File Path:.113 i1P MOSSIAWPLAMJte Report Exhibita12000481A10 LOC Map uUAwg,Layout location map Mon,MOO,2007.4:02 PM tl{x:Haunch 2-1 daa71 N2 I:OD 35' i 701 raROAO BROOK) 32',30"•• 66O d00 PQ$7' SOS ` wlNasoRwl.l.rc+'•a+Hr. ".•rtiwrrev f a e � , .•f � of \ v` \%' •••.•Rq V„•�,1 to:f• d�"a" . 1 r� `aI' O i '( d ''?nj � �� • � ' � j �`� �' , �� � o biz •4�., r • 1 � '� r • � Z • •� / m'nQ • ••p9 •. .� I ' a lia • ,• `aiiii0. • ' ~ 10� •••,i •lot �•tarry•;', t' • .j � � ... .. .. • .•�y,+ ,I '�� ,• Y���'•'- ..� ••saki i S'•�' j�'' Z'y', � r O •�'� ��,i \♦\\• I • �/ •• .r o Tak'� r 164 ti0 • ��� • •r �F t j�•• �r��• , ' , • ,; � • , • , r•� • O j 11�7 r 1� 1' 'r Y v 1•� 8 ,q•"QA. Ea '11 'P j • 1 • • • 7' • r •• t w 1 yq rjr'+4• ���� � •• ��hri , .� «•,Ip/�'.••.• . t��. • :r '•n�1�t•i.�`•/`•' •11: ,( .• ' 0 o 4. f . . • •V •` ,+�i �J,•, m o m=o r,e+•,IpI,.+Y• ,.• r„ •' 1 ''� •.,. '..r' , Coy • •\ • • `I �"'`•. ~.��. �.��. �•0 +�. •• ��fir• ��� ••Q. ` �� I.1�.� �•�l • 1 • •{��d. `.(\. C�4�?'y� r}�f 1. �• i j' •+\ D � q '.�j.•t�,7.6ry " i Y 1`4 I •. � 'jll/ ,OF . •,,,:�f••A�• I • _`[ O'! 'I • •'�J•,••��i/\�,•� �^ •• w drS'RON •'b .•w�1n .. ' Y�4 �` •••' Sri' ,•••M19 • • • ••♦ •7• .•:R•v ',� Aiu •'r•. ..i.. A' : •V•' 1 '.tM'� �. rw I r '/ � � C'^ • • '. • a{�dt•�• ', • ••\ \[��\l{�i . +1•�••�.,,•:q• ♦ r• N••WWI • JQT � I • _• ��y/'p.� t � �` , 1.P • •�,! �'LYi� r ..• �. \ll \��• 1,� �.. �+�_ '' _._. _ if. • / �� .w•��. `':j:�1V/Cj� 1, l�' Rr�! 1•( .• r n ._� t��� / • i`�� '�'.,\!. EXISTING 12" WATER LINE �F I EXISTING WATER LINE J cc ta I _ / / - - PROPOSED WATER LINE " > EXISTING 1 2' 0e WATER LINE n ill: �r qe 'i it EXISTING WATER OFF �Q J11 - V x x J/ r Y ti _ _ • J� Y J x x:x EXISTING SAN ITARY r rr •' ,\FM SEWER LINE 1 .5 SDR 9 HDPE IPS ' m�ha �l �•�� r ; � � G R C r" b I PROPOSED SANITARY - °° ` SEWER LINE (TYP.) T EXISTING 8" SANITARY si i SEWER LINE Dav i EXISTING 12 SANITARY o.. '. � � � x SEWER LINE r PAYMENT SUMMARY RECEIPT TOWN OF SOUTH WINDSOR 1540 SULLIVAN AVENUE SOUTH WINDSOR CT 06074 DATE: 02/24/14 CUSTOMER#: 000000000 TIME: 11:25 CLERK: laurenlz RECPT#: 20696364 PREV BAL: TP/YR: MS/2014 AMT PAID: 385.00 BILL: ADJSTMN'T: EFF DT: 02/24/14 BAL DUE: PERMITS/INSP PAYMENT -----------------TOTALS----------------- PRINCIPAL PAID: 385.00 INTEREST PAID: .00 ADJUSTMENTS: .00 DISC TAKEN: .00 AMT TENDERED: 385.00 AMT APPLIED: 385.00 CHANGE: .00 PAID BY: FLB ARCHITECTURE & P PAYMENT METH: CHECK PAYMENT REF: 14715 PLANNING DEPARMENT IN-HOUSE REFERRAL FORM DATE: 2/25/14 TO: Matt Galligan, Fred Shaw, Michael Gantick, Walter Summers, Jeff Doolittle Ray Favreau, Mark Owens, Chris Dougan, Sherry McGann, Ron Asselin, John Caldwell, Dennis Sheridan, Glen Buonanducci FROM: Michele Lipe,AICP, Town Planner The Planning &Engineering Departments have received plans for the following projects: I Appl 14-09P, Evergreen Walk General Plan of Development renewal Location: 151 Buckland Road ❑ Site Plan ❑ Subdivision No. Acres 232+ Zone BGZ ❑ Industrial ® Commercial ® Residential No. Lots/Units 200 Water: ® Public ❑ Private Well Sewerage: ® Public ❑ Septic System Project Description: Renewal of general plan of development Future Town-owned property involved? ❑ Yes ® No ❑ new street(s) ❑ new detention area ❑ new open space/recreation area ❑ active ❑passive Planning Department notes: Please comment by 3/7/14 and return to the Planning Department. FLB Architecture & Planning, Inc. 19 Silver Lane East Hartford CT 06118 860 568-4030 fax: (860)568-5129 e-mail:flbQflbarch.com web.www.flbarch.com LETTER OF TRANSMITTAL GPD.Doc00\General Plan Of Development 2014\ML 140225 Appl For Date 2/25/14 Project No. 99508.00 Attention To: Michele Lipe, Town Planner Project General Plan of Development Town of South Windsor Ever reen Walk South Windsor, CT We are sending you x Attached ❑ Under separate cover via the following items: x Prints ❑ Copy of letter ❑ Shop drawings ❑ Original tracings ❑ Copy of memo ❑ Samples les❑ Specifications ❑ Change order proposal request Code modification request ❑ Request for Payment ❑ Change order x Other as described below Item no. Copies Date No. Descri tion 5 3 Rev Z-1 to Z-3 FLB Master Plan—General Plan of Development 2/24/14 KI THESE ARE TRANSMITTED as checked below: j" ZC014 ❑ As requested ❑ Approved 92=1 PLANNING DEFT• pies for approval El Foryouruse El Furnish as corrected copies to distribute ❑ For review ❑ Rejected ❑ Return corrected prints &comment ❑ Submit specific item ❑ x For approval ❑ Forbids due ❑ Prints returned after loan to us Remarks: Revision to GPD is only to correct some confusion with4he 65-foot setback and the 75-foot buffer along the west property line of the land of EvergreenWaTk. L Copy to: file :�AilanbV�Lamson, AIA, AIC If enclosures are not as noted,kindly notify us at once. S O.iN Stl 7-0� o-P S_ate V&U&ot C� 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074 sox•co TELEPHONE(860) 644-2511 February 26, 2014 Alan F. Lamson FLB Architecture & Planning, Inc. 19 Silver Lane East Hartford, CT 06118 Dear Mr. Lamson: Re: Appl. #14-09P, Evergreen Walk General Plan of Development Renewal Please be advised that the above referenced matter_ has been scheduled on the Planning & Zoning Commission agenda for Tuesday, March 11, 2014. The Regular Meeting is held in the Madden Room of the South Windsor Town Hall, 1540 Sullivan Avenue following the Public Hearing which begins at 7:30 p.m. Someone must be present at the meeting to represent the application. One sign advertising the meeting must be posted on the property for ten (10) consecutive days prior to the hearing and must be clearly visible from a town street. A sign must be posted on Buckland Road by Friday, February 28, 2014. Signs can be obtained in the Planning Department, Monday through Friday, 8:00 a.m. - 4:30 p.m. If you have any questions regarding this letter, please call 860-644- 2511, Ext 253. Sincerely, Lauren Zarambo Administrative Secretary 1 1�t,E p"r 1,Ep A.............Iiii LB Architecture & Punning, Inc. 19 Silver Lane East Hartford CT 0118 (860)568-400 fax: 860568-5129 e-mail:flbflbarch.co web,www.fiarc .cm LETTER OF TRANSMITTAL P:\99508.00\General Plan Of Development 2014\ML 140303 Additional Date 3/3/14 Project No. 99508.00 Copies.Doc Attention To: Michele Lipe, Town Planner Project General Plan of Development Town of South Windsor Evergreen Walk South Windsor, CT We are sending you x Attached ❑ Under separate cover via the following items: x Prints ❑ Copy of letter ❑ Shop drawings ❑ Original tracings ❑ Copy of memo ❑ Samples ❑ Specifications ❑ Change order proposal request ❑ Code modification request ❑ Request for Payment ❑ Change order ❑ Other as described below Item no. Copies Date No. Description 1 9 2/19/14 URS Traffic Impact Study letter 2 9 2/20/1/4 F&O Utility Impact Stud 3 3 Rev Z-1 to Z-3 FLB Master Plan—General Plan of Development 2/24/14 MAR RECEIVED PLANNING DEPT. THESE ARE TRANSMITTED as checked below: SOUTH WIND30R x As requested ❑ Approved ❑ Resubmit copies for approval x For your use ❑ Furnish as corrected ❑ Submit copies to distribute ❑ For review ❑ Rejected ❑ Return corrected prints &comment ❑ Submit specific item ❑ ❑ For approval ❑ Forbids due ❑ Prints returned after loan to us Remarks: Additional copies of previously submitted documents A%3evdM e uest Copy to: file Alan F. Lam , AIA, AICP If enclosures are not as noted,kindly notify us at once. T6,'ProwLe,Ka4e, Slaps O EVERGREEN WALK March 10, 2014 RECER50 Michele Lipe,AICP,Town Planner ,H s F,:, Town of South Windsor `''` ' r.� 14 1540 Sullivan Avenue SOUTNWINDSOR P0NIN�DEPT. South Windsor,CT 06074 VIA: Hand Delivery RE: Appl. 14-09P, Evergreen Walk LLC- request for a reapproval of the General Plan of Development layout including 725,000 sf of retail; 200 residential dwelling units; 75,000 sf of recreation space; 250 hotel rooms; 550,000 sf of office space to be located on 151 Buckland Road (within 'Evergreen Walk'), on the westerly side of Buckland Road,on the southerly side of Deming Street and northerly of Smith Street, Buckland Road Gateway Development Zone Dear Ms. Lipe: In regard to traffic safety on Tamarack Avenue,we ask that you consider approval of a 4-way stop at the intersection of Tamarack Avenue and Evergreen Way versus the current 2-way stop. Landlord is concerned over the number of near accidents that have been reported or witnessed firsthand at this intersection. Installing stop signs on Tamarack Avenue would alleviate the uncertainty many drivers seemingly have coming upon the intersection as some proceed as if it is a 4-way stop already while others are aware that it is not and proceed without caution through the intersection when there are no pedestrians to yield to in the crosswalk. Vehicles exiting from Evergreen Way onto Tamarack Avenue continually make the assumption that cross-traffic on Tamarack Avenue will "stop" and therefore proceed through the intersection and exacerbate the issue. To keep traffic continually moving,when entering the property via Tamarack Avenue from Buckland Road there is a bypass road to the right just past the monument sign that provides an alternate access to the Center and its parking. Upon installation of the new stop signs, additional signage could be added to draw attention to this route. Thank you for your consideration. I look forward to hearing from you. Sincerely, y,' , / c_4_ ti-fit-_—. Elizabeth Maheu, General Manager 501 Evergreen Way, Suite 503, South Windsor, CT 06074 Phone 860-432-3398 Fax 860-432-3484 www.thepromenadeshopsatevergreenwalk.com �p%qN Sf4 _0� O-P S_a� V&U&olt y F 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074 SOR-CO TELEPHONE (860) 644-2511 March 11, 2014 Michele Lipe Town Planner Town of South Windsor Re: Buckland Road Area Development Water Supply Dear Michele, This area has been under substantial commercial development for sometime now and the concerns of this Office with water supply needs have not been addressed. The Fire Marshal's Office has expressed two areas of concern for the current design of water supply for this area. The use of a single feed for water supply from the provider and the ability to meet certain water supply demands. Connecticut Water Company supplies this area of significant commercial development with a single 12"main from Deming Street. If this main becomes compromised without a redundant feed from the East Windsor area, the area will be without water until back up measures have been put into place. Current back-up plans include a hydrant to hydrant hookup with MDC at Deming and Buckland. MDC operates a water system at a lower pressure than CWC. An emergency valve has been placed in the Lowes' parking lot to connect to Manchester Water. This valve has not been turned on and in dispute for the last two years. If this main becomes compromised,the need for a second redundant feed from CWC to this area is obvious. In researching the NFPA documents for preliminary fire fighting flows and demands for these projects, proposed developments will require 2,000 gallons per minute for duration of 4 hours. This figure does not include the required fire sprinkler demand which could range up to 1,300 gallons per minute for duration of 2 hours. Also, if standpipes are required to be installed in the hotels then the demand of those systems could be 750 gallons per minute at 100 pounds per square inch. These figures represent a significant demand for fire protection in this area which is presently supported by a single main feed. Also, some sprinkler design could require a fire pump to be attached to the fire sprinkler system. CWC does not allow fire pumps to be connected directly to the water mains requiring the developer to install water tanks to supply the fire pump. With the future of this area growing at such a fast pace and the need to address the problems in front of us, it will be the position of the Town of South Windsor Fire Marshal any future development projects require a written plan of action in place to provide this area a second water supply feed. Respect y, Walter Summers Fire Marshal 4 Appl #14-09P, Evergreen Walk General Plan of Development 3-11-2014 Planning Department Report 1. This is a request for reapproval of the General Plan of Development for development on 243 acres on the west side of Buckland Road, Buckland Gateway zone, in accordance with the provisions of Section 8.1.2. 2. This plan was originally approved in 2001 and had five year expiration. Due to lawsuits filed, and the time it took to resolve all cases, the effective date of this approval was in 2009 with expiration in 2014. Our regulations were changed in 2007 such that general plans no longer have a time period associated with them. 3. Changes from the original approval include: • retail increase form 375,000 sf to 725, 000 sf; 200 units of residential added, office decreased from 650,000 to 550,000 sf • the number of hotel rooms at 250 and indoor recreation at 75,000 sf remain unchanged 4. The stated purpose of the Buckland Gateway zone is "to create an attractive entrance to South Windsor. This zone should foster high-quality development of businesses and sites, with careful attention to the appearance of buildings and surrounding site." The stated general concepts include: • Sites developed.under this zone ar_e intended_to_be carefully planned, both within the site's own boundaries and in relation to surrounding properties and the entire Gateway zone. • Retail design determines much of the character and attractiveness of major streetscapes. In recognition of this, the Gateway zone includes special standards and guidelines for retail developments. • Avoidance of prototypical franchise-type buildings unless the building truly demonstrates architectural excellence. • Access management, in order to reduce the number of driveway cuts onto Buckland Road and mitigate the deterioration of traffic flow generally caused by driveways on arterial streets. • Shared retention/detention basins. 5. The access management requirements of Section 3.A, Sullivan Avenue-Buckland Road Corridor limit the number of driveways on a commercial site with more than 450 feet of frontage to two access points. In 2001, the applicant received a waiver to be allowed the third signalized access after it was determined that this would provide the best i balance between traffic flow on Buckland Road and access requirements for this large project. 6. In 2007, the applicant had requested and received approval from the STC for the changes in the proposed square footages. With that approval, the applicant has to complete improvements included adding an additional turn lane off Buckland Road on to Tamarack Drive and an additional turn lane off the exit ramp onto Buckland Street. The Buckland Road turn lane is intended to be constructed at the time of the hotel. 7. Pedestrian access has been provided throughout the site, with sidewalks currently along the entirety of Buckland Road, the interior roadway network through the Shoppes. The sidewalk network heading north will soon be interconnected with the extension of the access drive connecting to Tamarack Road and out to Deming Street. A walking trail system is proposed along the western portion of the site and the first phase of that trail system will be built along with the hotel and residential projects. Bikeways are not formalized; however the inner road network has traffic speeds slow enough to accommodate bikers. As development continues, we want to continue to ensure that there is a strong pedestrian and bicycle connection between the many facets of the project. 8. Maximum impervious coverage allowed is 60%, with a minor bonus for consolidated parcels and a minor reduction for 6-story hotel. There is a requirement in the Gateway zone that area reserved for open space and set aside to meet impervious coverage requirements shall be distributed throughout the site in such a manner that the land is visible from public streets and/or useable (for example, for pedestrian circulation, outdoor entertainment and cultural events, bandshell, or arts/crafts shows). 9. The Gateway zone allows increased height for increased setback from Buckland Road. All of the retail buildings are proposed to be one or two stories. The office buildings vary from two to four stories, and the current hotel proposals are for four stories. A waiver would be required for the six-story hotel. That waiver may be granted by the Commission for a building located at least 200 feet from any public street and from any residential zone boundary, and the Commission determines it meets other criteria listed in Section 4.2.8G. The approved Cambria Suites hotel will be four stories. I O.All of the parking is proposed to be surface parking. The Gateway zone regulation notes that it is the intent of this regulation to create off-street parking that is creative and to achieve attractive, innovative parking layouts that will accent and highlight buildings and features of the zone. The view of parking areas from Buckland Road shall be minimized through the use of perimeter landscaping and berms. To the fullest extent possible, existing trees shall be saved by appropriate welling and mounding. Other landscaping elements such as decorative fencing, sculpture, fountains, stone walls, or attractive walkways and pedestrian spaces are highly encouraged. Off-street parking must generally be distributed around buildings. 2 11.Existing trees and hedgerows must be incorporated into site design and preserved to the maximum extent possible. The applicant should be aware that at the site plan stage, tree and hedgerow preservation must be satisfactorily addressed. 12.We want to emphasize that outdoor storage is not permitted in the Gateway zone. All business must conducted within completely enclosed buildings, with a few exceptions such as seasonal outdoor dining and outside display on the interior part of a pedestrian environment, such as a village-style shopping center. 13.Decorative lighting used for this development has set the standard for the remainder of the zone. 14.A 75-foot buffer is required along residential zone boundaries and has been shown on the development plan. The Commission approved a combined buffer and yard. 15.There are regulated wetlands on the site. IWA/CC approval is required at the site plan stage. 16.Public water is available in Buckland Road. Public sewerage is provided via a cross- country line that connects to the existing system in Clark Street. 17.Prior to any actual building or site construction, a full site plan of development that is in conformance with the approved general plan must be submitted and approved by the Commission. The site plan will include all of the engineering details as well as final building design and site layout. 18.If this General Plan is approved, Planning Dept. requests that several of original approval conditions related to general development of the site be incorporated into this approval. 3 ,�OYI N Sf4 C /J E" -0� ?40&U&0t s 1540 SULLIVAN AVENUE ° SOUTH WINDSOR, CONN. 06074 �r`�°soa•ca��� AREA CODE 860/644-2511 CERTIFIED MAIL October 17,2001 Mr. Alan Lamson FLB Architecture&Planning, Inc. 19 Silver Lane East Hartford, CT 06118 Re: Appl 01-26P,Evergreen Walk at Buckland Hills, General Plan of Development Dear Mr. Lamson: At its October 9, 2001, meeting, the Planning and Zoning Commission voted to approve your request for Evergreen Walk at Buckland Hills, General Plan of Development as shown on plans prepared by FLB Architecture&Planning,Inc, Job No. 99508.00, sheets Zl-Z8,dated June 18, 2001 as revised. This approval is subject to the following conditions: 1. This approval is for a General Plan of Development;which does not address many engineering and site design details. The applicant must submit an application for a site plan of development approval,at which time the Commission will review all specific details of the project,including but not limited to concerns raised during the General Plan application process. 2. In accordance with Section 3.A.4.b of the Buckland Road/Sullivan Avenue Corridor zoning regulations,a waiver is hereby granted to allow three signalized driveway intersections with Buckland Road, as shown on the General Plan. 3. The Plum Gulley Brook/Podunk River watershed is a highly sensitive watershed and stream corridor,hydrologically,hydraulically and ecologically. Storm drainage design at the site plan stage must thoroughly and adequately address storm water quality and quantity, including both on-site and downstream impacts. FF Black and white mylars of sheet 3 of the General Plan of Development(on 24"06"sheets),with this approval letter reproduced thereon,must be submitted. After the mylars have been endorsed by the Commission, they will be returned to you for filing in the office of the Town Clerk. Three blueprint copies of the entire set of plans must also be submitted. Sincerely, Walter J. Mealy, Chairman Planning and Zoning Commission WJM/kag cc: Fuss&O'Neill Town Engineer Chief Building Official Assessor i `O N N Sf4 co X F a ` 1540 SULLIVAN AVENUE ® SOUTH WINDSOR, CT 06074 l�dsox•co� TELEPHONE (860) 644-2511 CERTIFIED MAIL 7011 1570 0000 6337 4472 March 13, 2014 Mr. Alan Lamson FLB Architecture &Planning, Inc. 19 Silver Lane East Hartford, CT 06118 Re: Appl. 14-09P, Evergreen Walk, General Plan of Development Reapproval Dear Mr. Lamson: At its March 11, 2014, meeting, the Planning and Zoning Commission voted to approve your request for Evergreen Walk, General Plan of Development Reapproval as shown on plans prepared by FLB Architecture &Planning, Inc, Job No. 99508.00, sheets Z3-1 through 3, dated 02/24/2014 as revised. This approval is subject to the following conditions: 1. Site Plan of Development approval is required prior to construction,per Section 4.2.15.1) of the zoning regulations. Construction phasing must be included on Site Plan of Development if appropriate. 2. No building permits will be issued until any required STC certificate has been issued(per CGS §14-311). 3. The Commission notes that this approval is for a General Plan of Development, which does not address all engineering and site design details. The applicant must submit an application for a site plan of development approval, at which time the Commission will review all specific details of the project, including but not limited to the following concerns raised during the Zone Change/General Plan application process: • The applicant must evaluate modifying the existing intersection at Tamarack and Evergreen Way for consideration of incorporating a four-way stop. • Any application for approval of a"Final Plan" for the development of an additional area within Evergreen Walk, which area is not as of this date the subject of an approved"Final Plan", shall require submission of a written plan of action to provide adequate water supply for the proposed use. This requirement shall not apply to a modification of any existing "Final Plan" approval for any portions of Evergreen Walk. 3. The Plum Gulley Brook/Podunk River watershed is a highly sensitive watershed and stream corridor,hydrologically, hydraulically and ecologically. Storm drainage design at the site plan stage must thoroughly and adequately address storm water quality and quantity, including both on-site and downstream impacts. 4. Views of parking areas from Buckland Road must be minimized through the use of berms and perimeter landscaping. Parking lot lighting in close proximity to Buckland Road will be pedestrian-style (but may be higher and brighter). 5. Roofs and roof equipment must be screened from Buckland Road, Smith Street and Deming Road. 6. Pedestrian and bicycle interconnection between the lifestyle center("main street"retail center), indoor recreation facilities, office and housing must be provided. 7. Delivery trucks must use routes other than the "main street"to make site deliveries. 8. When details of Buckland Road widening are finalized at the site plan stage, adequate additional right-of-way along Buckland Road must be provided. 9. Trees and hedgerows must be preserved to the maximum extent possible; preservation details to be shown on the site plan. 10. No outdoor storage is allowed in the Gateway zone, per Section 5.8.6.c of the zoning regulations. 11. Construction phasing, including phasing of external roadway improvements, must be shown on the site plan. 12. As additional green space is added, it should include some of the site's existing natural features. Black and white mylars of Sheets Z3 -1 through 3 of the General Plan of Development, with this approval letter reproduced thereon,must be submitted. After the mylars have been endorsed by the Commission, they will be returned to you for filing in the office of the Town Clerk. Three blueprint copies of the entire set of plans must also be submitted. Sincerely, Bart Pacekonis, Chairman Planning and Zoning Commission BP/llz cc: Fuss & O'Neill Town Engineer Chief Building Official Assessor