Loading...
HomeMy WebLinkAbout96 Griffin Road - WPCA Application, Approval Letter (2 Lot Subdivision) 10 N Sfq �� 010 7 r O w J C u 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074 f�OSOR-CO TELEPHONE (860) 644-2511 May 6, 2010 Wayne C. Gerlt, Esq. 112 Deming Street P. O. Box 1132 South Windsor, CT 06074 Re: WPCA Final Approval-2 Lot Resubdivision- 96 Griffin Road, East Windsor, CT Dear Atty. Gerlt: The South Windsor Water Pollution Control Authority, at its regular meeting on May 4, 2010, gave approval to the application for connection to the Town of South Windsor sewerage system of a proposed 2 lot single family residential subdivision in East Windsor, CT for connection to the existing South Windsor sanitary sewer on Griffin Road; as more specifically shown on plans entitled "Resubdivision Plan; Mitchell Resubdivision Prepared for Dustin Mitchell, East Windsor and South Windsor, Conn.", prepared by Aeschliman Land Surveying, PC, East Hartford, CT. Sheet No 2 of 3 "Topographic Map" Dated 1-13-10 and Revised on 4-19-10 "Staff Comments" and 4/1/10. This approval is subject to the following conditions: 1. The proposed 8 inch sanitary building sewer between the proposed manholes should be changed to a 6 inch sanitary building sewer to service the two houses. 2. The property owner will be billed with the same sewer charge that is billed to out of town sewer users; 3. Final Approval from the East Windsor WPCA; 4. Technical approval of the Town of South Windsor Engineering Department; 5. Final South Windsor Water Pollution Control Authority approval and acceptance of the sanitary sewerage connection will be conditional upon the sewer•line having been installed and inspected by the South Windsor Town staff, and upon the written verification of the South Windsor Town staff that said sanitary sewer line was installed in substantial conformance with the design plans approved by the South Windsor Water Pollution Control Authority, and meeting all South Windsor Town regulations and appropriate technical specifications relating to sanitary sewer construction. Very truly yours, Joseph J. Carino, Chairman Water Pollution Control Authority JC:ead cc: Michael J. Gantick, Director of Public Works Jeff Doolittle, Town Engineer Marcia Banaeh, Director of Planning Chris Dougan, Chief Building Inspector TOWN OF SOUTH WINDSOO WATER POLLUTION CONTROL AUTHORITY APPLICATION FORM Application No.: Date Received Applicant DUSTIN MIT41!ELL Date Scheduled For Address C/O ATTORNEY GERLT PO BOX 1132 SOUTH WINDSOR CT 06074 Telephone No.: 860-644-2565 Owner of Record on Land Records DUSITN MITCHELL Owner's Address 90 Brookfield Street South Windsor CT 06074 Property Description: Assessor's Map# Parcel# Vol. Page Project Title: Mitchell Subdivision, nrenared for Environmental Services Inc. East Windsor, Conn. Inquiries to be Directed to: (Name, Address, Telephone No.) Wayne C. Gerlt Esquire 112 Demine Street South Windsor CT 06074 860 644 2565 Approvals Previously Received (Check) IWA P&Z ZBA Purpose of Application: (Check all that apply) 1. Sewer Extension/Connection- - Residential Use a. Subdivision b. Single Unit c. Other X Explain EXTEND SERVICE TO 2 LOT SUBDIVISION IN EAST WINDSOR ON NORTHERLY SIDE OF GRIFFIN ROAD PORTION OF PROPERTY IS IN SOUTH WINDSOR d. Type of Approval: Concept Final X 2. Sewer Extension/Connection - - Industrial/Commercial User a. New Connection b. Request to Increase Flow Rate c. Change in Nature of Waste Discharge d. Other Explain e. Type of Approval: Concept Final 3. Appeal of Sewer User Charge a. Residential b. Industrial/Commercial 4. Sewer Assessment a. 'Establish Sewer Assessment b. Appeal of Sewer Assessment c. Change in Use of Property 5. Regulatory Appeal , Explain 6. Other Explain (See Reverse Side for Application, mittal Procedures) Applican ' ignat re Dat Owner' r Date APPLICATION SUBMITTAL PROCEDURES 1. The Water Pollution Control Authority (W.P.C.A.) meets regularly on the first Tuesday of each month, except during the months of July and August. Check with W.P.C.A. Office (644-2511, extension 247) for meeting dates during these months. 2. All applicants requesting "final" approvals are required to have the prior approvals of IWA, P&Z and ZBA as appropriate. 3. It is suggested that prospective applicants contact the W.P.C.A. Office prior to submission of application. 4. Two sets of completed plans must be included, where appropriate, at the time the application is submitted. 5. Applications must be submitted to the W.P.C.A. Office in the Town Hall, 1540 Sullivan Avenue, South Windsor, Connecticut at least seven (7) working days prior to the date of the W.P.C.A. meeting. 6. After staff review, the Town will notify applicant if any further information is required, and the date of the W.P.C.A. meeting at which the application will be considered by the Town. w:poll.control/shaw/poll.control/ad _ ./WPCA/WPCA Appl. BOND TRANSMITTAL DATE: APPLICANT NAME 1 -ADDRESS w � r PROJECT LOCATION/ADDRESS T t�l K-oa Ct LOT SUBDIVISION b lisfln P&Z OR M/CC APPLICATION NUMBER .AMOUNT OF BOND U,3 CHECK NUMBER DEPARTMENT SUBMITTED BY NAME DATE RECEIVED BY FINANCE G p 3o to NAME DATE SUB ACCOUNT NUMBER 5 O O /6 6 \F«=wamts-sOO&A8OND riaxsh 11TAL 08-27.ol.&«