HomeMy WebLinkAboutWPCA 765 Sullivan Avenue z ' SOWN stq - a 1540 SULLIVAN AVENUE• SOUTH WINDSOR, CT 06074 f�OSoe•c°��� TELEPHONE (860) 644-2511 June 19,2009 Matthew Galligan Town Manager Town of South Windsor 1540 Sullivan Avenue South Windsor,CT 06074 Re: South Windsor Fire and Ambulance Facility(Approval) 765 Sullivan Avenue South Windsor, CT Dear Mr.Galligan: The South Windsor Water Pollution Control Authority, at its regular meeting of June 2, 2009, approved the application for the South Windsor Fire and Ambulance Facility, 765 Sullivan Avenue, for connection to the Town's sewerage system, as more specifically shown on plans entitled: "New Facility for the South Windsor Fire and Ambulance, 765 Sullivan Avenue, South Windsor, Connecticut", Prepared by TO Design, LLC, New Britain,CT.,Grading and Utilities Plan,Drawing No.: L-3,Project No.: 5033A-L,Dated 04/27/09,with revision dates of 05/12/09 and 05/20/09; also Site Details, Drawing No.: L-504, Project No.: 5033-L, Dated 04/27/09, with revision dates of 05/12/09 and 05/20/09. This approval is subject to the following conditions: 1. Technical approval of the Town Engineering Department. 2. Final Authority approval and acceptance of the sanitary sewerage connection will be given once the sewer line has been installed and inspected by the Town staff, and based upon the written verification of the Town staff f that said sanitary sewer line was installed in substantial conformance with the design plans approved by the Authority, and meeting all Town regulations and appropriate technical specifications relating to sanitary sewer construction. This approval letter must be superimposed on the final approval plans. Very truly yours,y J0414 f Joseph J. Carino, Chairman Water Pollution Control Authority JC:dt cc: Marcia Banach,Director of Planning Chris Dougan,Chief Building Inspector Michael J. Gantick,Director of Public Works Jeff Doolittle,Town Engineer 05/27/2009 WED 15:05 FAX IM002/004 TOWN OF SOUTH WINDSOR WATER POLLUTION CONTROL AUTHORITY APPLICATION FORM Application No.: Date Received --�— Da a Scheduled For Applicant / own o sott AA �- Address O .570et o C o o -7 f Telephone No.: . q-a S// x �o Owner of Record on Land Records - 'TozAl .S' orOwner's Address /Cj�� Src�/i'VQh ,�r/e Sou U126 c(ror 67- 06 D7� Property Description: Assessor's Map# �q a Parcel# 81 3 a�74ol. a�i o/S Page a�a Project Title: S o W,- .r o r f ey/v.9 a,G Inquiries to be Directed to: (Name,Address Telephone No.) G/inhLex Approvals Previously Received(Check) IWA P&Z V- ZBA . Purpose of Application: (Check all that apply) 1. Sewer Extension/Connection--Residential Use a.Subdivision b. Single Unit c. Other Explain d. Type of Approval:Concept Final 2. Sewer Extension/Connection--Industrial/Commercial User a. New Connection t✓ b. Request to Increase Flow Rate c. Change in Nature of Waste Discharge d. Other Explain. e. Type of Approval: Concept Final I Appeal of Sewer User Charge a. Residential b. Industrial/Commercial 4. Sewer Assessment a. Establish Sewer Assessment b. Appeal of Sewer Assessment c.-Change in Use of Property 5. Regulatory Appeal ,Explain 6. 'Other Exp in - A licant's Signature Date OJ Owner's Signature Date (See Reverse Side for Application Submittal Procedures) TRANSMITTAL To: C. Fred Shaw Date: 5-27-09 Superintendent Y Bureau of Pollution Control Town of South Windsor 1540 Sullivan Avenue South Windsor, CT 06074 From: Glen Martin Y TO Design,LLC Subject: WPCA Application Proposed Fire and Ambulance Facility y 765 Sullivan Avenue x # of Copies Drawing Drawing Description No. Rev.Date Site Plans—including grading and utility plan E, and floor plan 1 • Plumbing Plans ri N 2 • Application 2 • Grease Interceptor Information Sheets Remarks Please find the above referenced items attached for this application. If you have any questions please contact me at(860) 612-1700 xt. 24. Signed: U91 Now M CT 1 P:860-612.1700 1.8 -612-17 7 Enclosures } cciii Job#: 5033 0 TOWN & COUNTRY PLASTICS, INC. P.O. BOX 269, MORGANVILLE N.J. 07751 USA 732-780-5300 . FAX: 732-294-0001 OVERALL, INSTALLATION DI MENSIONS (FLOW CONTROL FITTINGS ARE SEPARATE OF THESE DIMENSIONS Model .. Approx. Approx. Approx. Approx. Inlet / Outlet Approx. "Body" Size Length Overall Number Y ' Fittings Length O.D. * 9 O.D. w/ O.D. Height I.D. w/ Cover Width two Fitting Skimmer L x W x H Size centerlines (LC) (LF) (W) (OH) # TCAGI -20 18 x 12 x 18 2" 16" 22" 28" 16" 19.1 # TCAGI -25 24 x 12 x 24 2" 20" 28" 32" 16" 24" #TCAGI -35 24 x 16 x 24 3" 20" 28" 38" 20" 25" # TCAGI -50 30 x 18 x 24 3" 20" 35" 44" 23" 25" NOTE: Add approx. 10" x 7" x 7" above unit for skimmer housing assembly. * Other fitting sizes available on special order. # TCAGI -20 30 x 18 x 12 2"# 9" 34" 42" 22" 14„ # TCAGI -35 36 x 24 x 12 3" g" 40" 50" 29" 13TCAGI -50 36 x 24 x 18 3" 13" 50" 29" 19" NOTE : • Larger, smaller or custom units always available. • .The 20 GPM rated and 25 GPM rated units had been certified by PDI (The Plumbing Drainage Institute) and one of the only approved independent testing labs to meet the ASME Standard #A112.14.3. Also, all our units have tested and certified skimming devices that meet the ASME Standard #A112.14.41 TOWN & COUNTRY PLASTICS, INC. P.O. BOX 269, MORGANVILLE, N.J. 07751 USA 732-780-5300 • FAX: 732-294-0001 LC SIDE VIEW ; SKIMMING OPTIONAL MOTOR PIPE AND ELBOW HOOKUP HEAT SENSOR AND ALARM TO COLLECTION]AR (BATTERY OPERATED) (PROVIDED WITH UNIT) SEPARATE THREADED (AVAILABLE AT EXTRA COST) i FLOW CONTROL TEE , SHIPPED WITH NOTE: INSTALLER INTERCEPTOR i HINGED COVER ' ' MUST ALSO VENT VENT DRAINLINE,AFTER SEDIMENT ANTI- C.O. GREASE INTERCEPTOR. BASKET SIPHON S.S. VENT O SKIMMING O BELT s QO 0 FPT MPT INLET �0 LOWER OUTLET FLOW O� 115 V HEATER PULLEY O 1"F.T. O FLOW FPT= FEMALE PIPE THREADS(IPS) , MPT= MALE PIPE THREADS(IPS) ; LF , NEW! AUTOMATIC SKIMMING GREASE INTERCEPTOR (AGRU) TOWN& COUNTRYIDLASTICS, INC. -- {{ P.O. BOX 269, MORGANVILLE, N.J. 07751 USA END VIEW 732-780-5300 • FAX: 732-294-0001 SKIMMER -------------------- -------------- OH INLET AND OUTLET D ' pr HEATER WR TOWN& COUNTRY PLASTICS, INC. P.O. BOX 269, MORGANVILLE N7 07751 USA 00!. 732-780-5300 • FAX 732-294-0001 WHAT'S NEW AND WHAT'S AVAILABLE: OUR HISTORY: WITH ABOUT 35 YEARS OF EXPERIENCE IN TOWN&COUNTRY PLASTICS,INC.(T&C)NOW KJROCKOFFERING THE BEST INTERCEPTORS"ON OFFERS YOU THE LATEST,MOST ADVANCED THE MARKET",CHOOSE BETWEEN T&C (AGRU)"AUTOMATIC SKIMMING GREASE AND OIL "AUTOMATIC SKIMMING GREASE INTERCEPTORS", INTERCEPTORS"ON THE MARKET! THESE AUTOMATIC INTERCEPTORS(TRAPS)FEATURE NUMEROUS BACTERIA INJECTION UNITS,SEMI-AUTOMATIC IMPROVEMENTS IN DESIGN AND PERFORMANCE, UNITS OR MANUAL GREASE TRAPS. T&C EVEN WHILE ADHERING TO THE CONCEPTS OF OFFERS HAZARDOUS AND DELETERIOUS WASTE SIMPLICITY AND EASE OF MAINTENANCE AND COLLECTION TANKS WITH MONITORING, INSTALLATION.IN ADDITION,THESE-AUTOMATIC- TREATMENT AND/OR ALARM SYSTEMS. OUR UNITS ARE VERY COMPETITIVELY PRICED. EQUIPMENT IS RELIABLE AND DEPENDABLE. VARIOUS SIZED UNITS AVAILABLE FOR ALL FOR ABOUT 35 YEARS NOW,T&C HAS BEEN THE CONDITIONS NEEDED. LEADER IN POLLUTION CONTROL EQUIPMENT AND SYSTEMS IN THE PLUMBING INDUSTRY. THE AUTOMATIC SKIMMING UNITS MEET AND T&C OFFERS GREASE,OIL AND SEDIMENT EXCEED GREASE AND OIL REMOVAL INTERCEPTORS,HAIR AND LINT TRAPS, REQUIRMENTS BY MOST GOVERNING AGENCIES. HAZARDOUS WASTE SUMPS AND TANKS, THE SKIMMED GREASE AND OIL IS DISCHARGED PHOTOGRAPHIC/X-RAY WASTE SILVER RECOVERY THROUGH A PIPE AND ELBOW INTO A LARGE UNITS,NEUTRALIZATON/DILUTION CHEMICAL COLLECTION JAR FURNISHED BY T&C. WE CAN WASTE TREATMENT TANKS AND SYSTEMS, ALSO FURNISH A COLLECTION PAILS AND DRUM,AT BIOLOGICAL WASTE"KILL"TANKS AND SYSTEMS, EXTRA COST. THE ACCUMULATED GREASE AND MONITORING,RECORDING& OIL MUST BE PROPERLY DISPOSED OF. THE ALARMS SYSTEMS,ETC. HAROLD MERMEL OF OWNER MUST HIRE A COMPANY THAT IS LICENSED T&C IS A CHEMIST AND CHEMICAL ENGINEER AND AND INSURED TO HAUL AWAY THIS"HAZARDOUS" IS A WELL KNOWN,HIGHLY SOUGHT AFTER GREASE AND OIL,PERIODICALLY. "EXPERT"IN THE TREATING OR COLLECTING OF ALL KINDS OF POLLUTED PLUMBING WASTEWATER ANOTHER CHOICE: (SPECIAL SANITARY WASTES). WITH OVER 100,000 SUCCESSFUL INSTALLATIONS,T&C REMAINS THE FOR ANYONE DESIRING THE BEST ANSWER FOR COMPANY OF CHOICE FOR THESE PRODUCTS ELIMINATING THESE"HAZARDOUS"GREASE AND THROUGHOUT THE USA AND THE WORLD. OIL WASTES,T&C RECOMMENDS OUR DIFFERENT, PROVEN"AUTOMATIC LIVE BACTERIA INJECTION THIS NEW INTERCEPTOR: GREASE AND OIL INTERCEPTORS"INCORPORATING OUR TRAP-ZAP SYSTEM. OUR LIVE BACTERIA ACT THESE LATEST"AUTOMATIC SKIMMING GREASE LIKE"PAC-MEN"AND EAT UP VIRTUALLY ALL THE AND OIL INTERCEPTORS"FEATURE COMPACT GREASE,OIL,FOOD PARTICLES,SUGARS, DESIGN,SUPERIOR LIGHT-WEIGHT,HIGH CARBOHYDRATES,PROTEINS,STARCHES,SOAPS, TEMPERATURE MATERIALS(HDPE AND PP)OF ETC. AND THE RESULT IS ONLY CARBON DIOXIDE CONSTRUCTION,STAINLESS STEEL SKIMMING AND WATER. ASK ABOUT OUR TRAP-ZAP GREASE BELTS,SKIMMING HOUSINGS AND HEATER AND OIL INTERCEPTORS. THE SPECIAL LIVE ASSEMBLIES,THREADED CONNECTIONS,FLOW BACTERIA WE USE IS SAFE FOR USE IN FOOD PREP CONTROL AND SOLIDS BASKET(FOR EASY AREAS. CLEANING),COMPACT S.S.HEATER WITH BUILT-IN TEMPERATURE LIMIT THERMOSTAT WITH BACTERIA INJECTION SYSTEMS WORK WELL AND ELECTRICAL PLUG,BATTERY OPERATED(EXTRA HAVE BEEN SOLD BY US FOR YEARS. (LIVE COST)TEMPERATURE SENSOR PROBE WITH BACTERIA ARE NOT LIKE ENZYMES OR DEGREASER ALARM,EASILY-MOUNTED COMPACT SKIMMING CHEMICALS.) ELIMINATING THE OIL AND GREASE UNIT WITH ELECTRICAL PLUG,DISCHARGE PIPE WITH NATURAL BIOLOGICAL BACTERIA IS BETTER WITH ELBOW AND LARGE GREASE/OIL THAN SKIMMING AND COLLECTING THE OIL AND COLLECTION JAR. THE PROVEN,SUPERIOR HIGH GREASE AND THEN PAYING SOMEONE TO DISPOSE DENSITY POLYETHYLENE(HDPE),POLYPROPYLENE OF IT PROPERLY. (PP) AND STAINLESS STEEL MATERIALS OFFER AN ADDED ADVANTAGE OF NON-STICK SURFACES FOR EASE OF CLEANING(IF NECESSARY). NOTE:THESE T&C AUTOMATIC SKIMMING GREASE INTERCEPTORS SHOULD BE SIZED THE SAME WAY AS MANUAL UNITS,BASED UPON"P.D.I."ESTABLISHED AND APPROVED INTERCEPTOR SIZING STANDARDS. ALL THESE AUTOMATIC AGRU UNITS HAVE SKIMMERS CERTIFIED TO MEET THE ASME CODE.THE BODIES OF A COUPLE OF THE UNITS HAVE ALSO BEEN TESTED AND CERTIFIED TO MEETTHE ASME CODE. TOWN & COUNTRY PLASTICS, INC. P.O. BOX 269, MORGANVILLE, N.J. 07751 USA 732-780-5300 • FAX: 732-294-0001 NEW! IMPROVED AUTOMATIC SKIMMING GREASE INTERCEPTORS (TRAPS)) MADE OF SUPERIOR HDPE, PP & SS MATERIALS HEAT SENSOR ALARM (AT EXTRA COST) nSKIMMERHDPE=HIGH DENSITY POLYETHYLENEPP=POLYPROPYLENE IN FLOWSS=STAINLESS STEEL O HEATOUT T & C HAS BEEN THE LEADING INNOVATOR OF GREASE, OIL AND SEDIMENT (PLASTER, CLAY, HAIR AND LINT) INTERCEPTORS/TRAPS FOR WELL OVER THIRTY-FIVE (35)YEARS NOW! T & C OFFERS MANUAL, SEMI-AUTOMATIC, AUTOMATIC SKIMMING AND AUTOMATIC LIVE BACTERIA INJECTION UNITS... T &C ALSO OFFERS SUPERIOR, LARGE, RIGID PLASTIC, UNDERGROUND MANUAL UNITS TO COMPETE WITH CONCRETE AND STEEL UNITS. WHATEVER YOUR GREASE AND OIL NEEDS, CONTACT T & C FOR SUPERIOR PERFORMANCE, SIMPLICITY OF MAINTENANCE AND INSTALLATION AS WELL AS COMPETITIVE PRICES. DOUBLE COMPARTMENT SINK (Above Floor Installation) ' FLOW CONTROL, VENTED WITH AIR INTAKE WASTE (VENT) F LQW IN . ..."�,". OUT , _ .M.M:f: :':^J!/..._,.: ^_ f�'_::!rJ ::�/r` ;`.'fi.>•' ...:..i`%-. '< _'^.f',' �-�,`.f V''_,'!� ..;;lr,'� .,.. _ , CLEANOUT NEEDED FOR PERIODIC CLEANING OF LINE