HomeMy WebLinkAboutWPCA 673 Ellington Road Y r. a�W N sea 0 a u m � 0-le sou� 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074 �OSOR•CO TELEPHONE (860) 644-2511 January 7,2005 Messier&Associates,Inc. 288 Main St. Manchester,CT 06040 Attn: Ray Nelson,Jr. RE: St.Francis of Assisi Church 673 Ellington Rd. South Windsor,CT Dear Mr.Nelson: The South Windsor Water Pollution Control Authority,at its regular meeting of January 4,2005,gave approval for the connection to the Town's sewerage system of a building located at 673 Ellington Road, South Windsor,CT,as more specifically shown on plans entitled"St.Francis of Assisi Church—General Location Plan., .prepared by Messier&.Associates,Inc.,Project No.01-019,Plan No.04-016A,dated_03- 04, with revisions dated 4-26-04,5-11-04,5-26-04,6-18-04, 12-10-04, 1-04-05 and subject to the following conditions: 1. Proper permit,must be,obtained from the State for the grease separator and all requirements by the State and Town must be met. 2. Technical approval of the Town Engineering Department. 3. Final Authority approval and acceptance of the sanitary sewerage connection will be given once the sewer line has been installed and inspected by the Town staff,and based upon the written verification of the Town staff that said sanitary sewer line was installed in substantial conformance with the.design plans previously approved by the Authority,and meeting all Town regulations and appropriate.technical specifications relating to sanitary sewer construction. This approval letter must be superimposed on the final approval plans. Very truly yours, C , J' eph J.Carino,Chairman Water Pollution Control Authority JC:dd Cc: Matthew Galligan,Town Manager Michael J.Gantick,Director of Public Works Jeff Doolittle,Town Engineer Marcia Banach,Director of Planning Chris Dougan,Chief Building Inspector St.Francis of Assisi Church ` TOWN OF SOUTH WINUSOR WATER POLLUTION CONTROL AUTHORITY APPLICATION FORM Application No. Date Received Date Scheduled For / -y-o g' _ Applicant 6SS is 1 CAW—'emir. C-scoe�. ev d-� So`'i'1�.ycc.�i cov►.C..nrF- •a; Address E w . Teleph ne No. 9i6ft) S26- SW Owner of Record on I rnd Records �c.w•e. Owners Address So.,N.e Property Description: Assessor's Map # Z 3 Parcel # 441 Vol. (, R6 Page S o Project Title: r Nka Inquiries to be Directed to: (name, address, telephone no.) F .�ye.irer.,�,,,, p• . Mes,$er Lys-sacS&-Arw , 1yv-T,36 to - SAMee j--P'loa.r���c-r-oCc`Eo C860lb�bola Approvals Previously Received (Check) IWA ✓ P & Z ✓ ZBA Purpose of Application: (Check all that apply) 1. Sewer Extension/Connection -- Residential Use a. Subdivision b. Single Unit c. Other xpTain d. Type o Approval: Concept Final 2. Sewer Extension/Connection -- Industrial/Commercial User a. New Connection b. Request to Increase ow to ✓ c. Change in Nature of Waste Discharge d. Other Explain e. Type o Approval: Concept Final j3J__ i G� 3. Appeal of Sewer User Charge `r a. Residential b. Industrial/Commercial w 4. Sewer AssessmentV- a. Establish Sewer Assessment s�.vvn�®soa b. Appeal of Sewer Assessment c. Change.in Use of Property 5. Regulatory Appeal ; Explain - 6. Other Explain ✓r i�Applica4Ctre ate Owner' Date (See verse Side for Application Submittal Procedures) / so/WPG/appiicarion 111261% Ded 0€} ,l6 08: 17a Progressive Engineering 860-895-8386 p. 2 PR �' G R ENGINEERING ,ESSIVE � INC F(:v q To: Mr. Fred Shaw From: Robert Chamberland (Health Inspector for South Windsor) Fax: 860 644-7280 Pages: 3 (including cover sheet) Phone: 860 803-8886 Date: December 6,2006 Re: St.Francis of Assisi,South Windsor,CT CC: PN:06044 file folder Interior Grease Trap catalog cut and c/c Kirk Bostwick-Bostwick Architects @860 570 1318 Calculations ❑Urgent ❑For Review ❑Please Comment ❑Please Reply ❑ Please Recycle •Comments: Fred, Attached are catalog cuts and calculations for the Interior Grease Trap as per your request. If you have any questions or comments,please feel free to contact us. 28 Main Street East Hartford Connecticut 06118 telephone 860.895.8385 fax 860.895.8386 www.ProgressiveEng.com Dec 08 �06 08: 18a Progressive Engineering 860-895-8386 p. 3 PR IMGRESSIVE Page:_of 1 �!i G,'-,`[Jab: —J— ENGINEERING, INC Designer: - t Date: /HILL Cp �1PA le: 'r� k —23 ; . . gg> t i : 3 : l T� v� ���LLL�tw.$•" 1 � � JA 4--- f T`f . _. tt +...:...�.. AV— 4- 7 a �...... r._...:..-.. I.- i - _. - : . _ Dec 08 ,06 08: 18a Progressive Engineering 860-895-8386 p. 4 r WS-2006-US b r � • b M -G-AD Automatic Recovery Grease Interceptor MI-G-AD SCHEMATIC - - `---- FJectronicdrain valve Inlet baffle tofrse�nsors and afiama INLET r. �+ OUTLET Colleowr Box 20"x 72"x 6-high outlet baffle • Inlet baffle MI-G-AD 3.7s . OPTIONAL EXTERNAL 75.5• - to.z5 BASKET STRAINER BOX 14•�f4• OPERATION: EFFLUENT ENTERING THE INTERCEPTOR IS FORCED DOWNWARD BY THE INLET BAFFLE TO FACILITATE SEPARATION BY SPECIFIC GRAVITY.A THERMOSTATICALLY CONTROLLED HEATING ELEMENT MAINTAINS A CONSTANT TEMPERATURE SO THE GREASE DOESN'T CONGEAL.AS THE GREASE UNI ACCUMULATES AT THE SURFACE,IT IS REMOVED TO THE COLLECTOR BOX.A SENSOR PROTECTS THE T FROM SUDDEN CHANGES IN WATER LEVEL,SHUTTING OFF THE ELECTRONIC DRAIN VALVE TO PREVENT WATER FROM ENTERING THE COLLECTOR BOX. AN AUDIBLEMSUAL ALARM REMINDS THE OPERATOR TO EMPTY THE COLLECTOR BOX. DETAILED INSTALLATION AND MAINTENANCE INSTRUCTIONS ARE SHIPPED \. WITH THE UNIT.FOR A SEPARATE COPY,PLEASE CONTACT YOUR LOCAL MIFAB•REPRESENTATIVE. ounizeT !; f F B A lit (s.r v� Cap. A B C D E F Number Lbs IN IN IN IN IN 1N MI-G-AD ROUGH-IN DIMENSIONS NOTE: ADD 8"(200)TO THE "A"DIMENSION TO OBTAIN THE OVERALL LENGTH OF THE INTERCEPTOR(THIS ALLOWS FOR THE MI-GAD-5 25 50 30 19 6.5 10 16.5 3 DRAW-OFF VALVE AND CONNECTIONS) ModM"-G-AD-5 US MI-G-AD W External GPM List price basket >`bs strainer 20 P.O.A. 65 P.O.A. ' 25 P.O.A. 75 P.O.A. 35 P.O.A. 120 P.O.A. 50 P.O.A. 150 P.O.APage :n'? (D ; :`3:'�1T:r:�•Y' 'Y _ Design snd dimensions are e tea-. ;.. :*�n'ti''^' =- -.,.a'.-n..^X°�s` `: Prices do not include applieaba ie,taxesmodifieatlon WWW.MIFAR.COM Dew 08. 06 08: 17a Progressive Engineering 860-895-8386 p. 1 Robert Chamberland From: Fred Shaw[shaw@southwindsor.org] Sent: Thursday, December 07,2006 5:43 PM To: Robertc@progressiveeng.com Subject: St. Francis Of Assisi Church-Grease Interceptor Bob: T have reviewed your submittal dated December 6, 2006 for the proposed interior grease interceptor MIFAB Model No. MI-G-AD-5 along with associated calculations to support the selection of the unit size. I have found them to be acceptable and approve of its use in the Ches food Preparation area. urch C. Frederick Shaw, Superintendent Pollution Control Town of South Windsor 1540 Sullivan Avenue South Windsor, CT 06074 TEL. : (860) 644-2511, EXT. 247 CELL: (860) 803-8886 FAX: (860) 644-7280 1