Loading...
HomeMy WebLinkAboutChange Order RECEIVED TOWN OF SOUTH WINDSOR S E P 2 0 2006 STAFF SITE CHANGE SOUTH WINDSOR PLANNING DEPT. FOR SITE & SUBDIVISION GENERAL: CHANGE ORDER CONTACT PERSON Kenneth Baldwin Phone No. (860) 275-8345 Address Robinson & Cole LLP, 280 Trumbull St. , Hartford, CT 06103 Site Name Verizon Wireless Store P&Z No. Owner M/S Town Line Associates LLC Phone No. Contractor Verizon Wireless Signature of Owner Date: B Signature of Des ' Engr. Date: • •off CHANGE: (Describe cation a change. Include Four (4 ) copies of plan profile of Change. ) Installation of two (2) roof-top antennas for in-building communications system Antennas are to be located approximately 26' from the roof edge of the Verizon Wireless retail store and extend 3'-6" above the roof. Screening panels designed to match the existing building will be installed around the antennas. Reason for Change: (Why is change required) To improve in-building communication service for technicians and potential customers. APPROVALS: (As Required) Dir. Of Planning Date: Town Engineer Date: ?L Dir. of Public Wor s Date: Other: Date: STAFF COMMENTS: White - Town Engineer Yellow - Applicant Pink - Director of Planning Goldenrod - Engineering Department S CELLCO PARTNERSHIP CELLCO PARTNERSHIP PROJECT SUMMARY \ DBA DBASITE NAME: VERIZON WIRELESS STORE SITE ADDRESS: 9 BUCKLAND ROAD ve✓n7 n wireless SOUTH WINDSOR,CONNECTICUT 06074 CONTACT PERSON CELLCO PARTNERSHIP DBA VERIZON WIRELESS DAVID CROTTY (860)803-8262 A&E FIRM Soo UBSCONIMI NON JURISDICTION: TOWN OF SOUTH WINDSOR 500 ENTERPRISE DRIVE • APPLICANT: CELLCO PARTNERSHIP DBA SUITE 3B vert O n wireless 99THART RD,CO ROCKY HILL,CONNECTICUT EAST EAST PJVE RD,CONNECTICUT 06108 1-(860)-529-8882 ARCHITECT: URS CORPORATION y� 500 ENTERPRISE DRIVE,SUITE 3B ` 6t�!>(�j _ ROCKY HILL,CT06067 Y °.•°ig.°�-�•ff{�t` • IN BUILDING WIRELESS LEGEND a� COMM [ ) NICA-TinNS., SYMBOL DESCRIPTION I v SECTION OR DETAIL NUMBER SHEET WHERE DETAIL/SECTION OCCURS 1�ELEVATION NUMBER VERIZON WIRELESS STORE 0-SHEET WHERE ELEVATION OCCURS ABBREVIATIONS PROJECT NO_ -36931028 9 BUCKLAND R OA U MIN. MINIMUM JOB N0 VZ7-203 V.I.F. VERIFY IN FIELD O.C. ON CENTER DRAWN BY: WRB PSF POUND/SQUARE FOOT SOUTH WINDSOR, CONNECTICUT 06074 Fr. TYPICAL CHECKED BY: SQ.FT. SQUARE FEET ISSUED FOR --_—_-__-—`---_— N/A NOT APPLICABLE -- --------------_._. ____ -_--- --------------____. 08-04-06 REVIEW GENERAL NOTES VIC ATY MAP NO SCALE 0815-061", — I - CODE REFERENCES 08 23-06 ZOM1at; 1. ALL WORK SHALL COMPLY WITH THE CONNECTICUT 9. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ON-SITE SAFETY a1 � CONNECTICUT STATE BUILDING OD STATE BUILDING AND LIFE SAFETY CODES, SUPPLEMENTS FROM THE TIME THE JOB IS AWARDED UNTIL ALL WORK IS b AND AMENDMENTS. COMPLETE AND ACCEPTED BY THE OWNER. N ° 2003 INTERNATIONAL BUILDING CODE 2003 INTERNATIONAL PLUMBING CODE 2. CONTRACTOR IS TO REVIEW ALL DRAWINGS AND 10. CONTRACTOR TO REVIEW ALL SHOP DRAWINGS AND SUBMIT 2003 INTERNATIONAL MECHANICAL CODE SPECIFICATIONS IN THE CONTRACT DOCUMENT SET. COPY TO ARCHITECT FOR REVIEW. DRAWINGS MUST BEAR 2003 NTERNATIONAL EXISTING BUILDING CODE CONTRACTOR SHALL COORDINATE ALL WORK SHOWN THE CHECKER'S INITIALS BEFORE SUBMITTAL TO THE 2005 CONNECTICUT SUPPLEMENT IN THE SET OF DRAWINGS.THE CONTRACTOR SHALL ARCHITECT FOR REVIEW. a 2005 NATIONAL ELECTRICAL CODE PROVIDE A COMPLETE SET OF DRAWINGS TO ALL B- SU CONTRACTORS AND ALL RELATED PARTIES.THE 11.THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, <% � CONN TI T cTAT RE SAFETY OD SUB-CONTRACTORS SHALL EXAMINE ALL THE DRAWINGS ELEVATIONS,ANGLES,AND EXISTING CONDITIONS AT THE 2003 INTERNATIONAL FIRE CODE AND SPECIFICATIONS FOR THE INFORMATION THAT SITE, PRIOR TO FABRICATION AND/OR INSTALLATION OF s THE INFORMATION CONTAINED AFFECTS THEIR WORK. ANY WORK IN THE CONTRACT AREA SUBMIT TO THE cy IN THIS SET OF DOCUMENTS 3. CONTRACTOR SHALL PROVIDE A COMPLETE BUILD-OUT ARCHITECT ANY DISCREPANCIES FROM THE DRAWINGS. g IS PROPRIETARY BY NATURE. WITH ALL FINISHES, STRUCTURAL, MECHANICAL,AND ANY USE OR DISCLOSURE ELECTRICAL COMPONENTS AND PROVIDE ALL ITEMS 12.THE COMRACTOR IS SOLELY RESPONSIBLE TO DETERMINE "°" OTHER THAN THAT WHICH AS SHOWN OR INDICATED ON DRAWINGS OR WRITTEN CONSTRUCTION PROCEDURE AND SEQUENCE,AND TO ENSURE IN SPECIFICATIONS. THE SAFETY OF THE EXISTING BUILDING AND ITS COMPONENT RELATES TO VERIZON WIRELESS PARTS DURING CONSTRUCTION. THIS INCLUDES THE ADDITION y gyp. IS STRICTLY PROHIBITED. 4. CONTRACTOR SHALL FURNISH ALL MATERIAL, LABOR AND OF WHATEVER SHORING, BRACING, UNDERPINNING, ETC.THAT SHEET INDEX EQUIPMENT TO COMPLETE THE WORK AND FURNISH MAY BE NECESSARY. p W7ETt A COMPLETED JOB ALL IN ACCORDANCE WITH LOCAL CHE AND STATE GOVERNING AUTHORITIES AND OTHER 13. COORDINATE ALL CIVIL AND ELECTRICAL DRAWINGS FOR THE ZOWN 0 pf DESCRIPTION VERIZON WIRELESS AUTHORITIES HAVING LAWFUL JURISDICTION OVER THE WORK. LOCATION OF ALL OPENINGS, RECESSES, BUILT-IN WORK, ETC. jpWN SHT. 5. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND 14. CONTRACTOR TO CONTACT"CALL BEFORE YOU DIG"AT 1-800- - NO.' STORE ALL INSPECTIONS REQUIRED AND SHALL ALSO PAY FEES 922-4455 TO VERIFY AND IDENTIFY THE EXACT LOCATIONS OF ALL REQUIRED FOR THE GENERAL CONSTRUCTION,PLUMBING, UNDERGROUND UTILITIES AND OBSTRUCTIONS IDENTIFIED PRIOR ELECTRICAL AND HVAC. SUB-CONTRACTORS SHALL PAY TO COMMENCING WORK IN THE CONTRACT AREA SITE ^ FOR THEIR PERMITS. 15. CONTRACTOR SHALL COMPLY WITH OWNER ENVIRONMENTAL ENGINEER 7�,,�/ SI I T E T-1 TITLE SHEET-GENERAL NOTES AND LEGENDS 9 BUCKLAND ROAD SOUTH WINDSOR, CONNECTICUT 6. CONTRACTOR SHALL MAINTAIN A CURRENT SET OF DRAWINGS ON ALL METHODS AND PROVISIONS FOR ALL EXCAVATION ACTIVITIES 'Sig. 06074 AND SPECIFICATIONS ON SITE AT ALL TIMES AND ENSURE THE INCLUDING SOIL DISPOSAL.ALL BACKFILL MATERIALS TO BE PROVIDED DISTRIBUTION OF NEW DRAWINGS TO SUB-CONTRACTORS AND BY THE CONTRACTOR. Z-1 PARTIAL ROOF PLAN OTHER RELEVANT PARTIES AS SOON AS THEY ARE MADE x"+�""' AVAILABLE.ALL OLD DRAWINGS SHALL BE MARKED VOID / SCALE: AS NOTED TH AND REMOVED FROME CONTRACT AREAL CONTRACTOR 16. CONTRACTOR SHALL COORDINATE DELIVERY AND INSTALLATION OF - - Z-2 PARTIAL SOUTH ELEVATION SHALL FURNISH AS-BUILT' SET OF DRAWINGS TO OWNER PRE-FABRICATED MODULAR EQUIPMENT SHELTER WITH VERIZON UPON COMPLETION OF PROJECT. WIRELESS. INSTALLATION Of THE SHELTER SHALL BE THE -S, TITLE SHEET RESPONSIBILITY OF THE CONTRACTOR. 7. INSTALLATION OF THIS WIRELESS COMMUNICATIONS EQUIPMENT GENERAL NOTES SITE REQUIRES WORK IN THE IMMEDIATE VICINITY OF EXISTING 17.ALL ANTENNAS,ANTENNA DOWN TILT BRACKETS,ANTENNA PLATFORM, m TELECOMMUNICATION SYSTEMS.THE CONTRACTOR SHALL COAXIAL CABLES AND COAXIAL CONNECTORS ARE FURNISHED AND ( AND LEGENDS PROVIDE AND COORDINATE THE METHODS OF PROTECTION INSTALLED BY OTHERS AND ARE SHOWN FOR COORDINATION WITH THE VARIOUS TELECOMMUNICATION CARRIERS. PURPOSES ONLY. 8. ALL EQUIPMENT AND PRODUCTS PURCHASED ARE TO BE REVIEWED BY CONTRACTOR AND ALL APPLICABLE SUB-CONTRACTORS FOR ANY CONDITION PER MFR'S 84 RECOMMENDATIONS. CONTRACTOR TO SUPPLY THESE Buckland / ITEMS AT NO COST TO OWNER OR ARCHITECT. T-1 CELLCO PARTNERSHIP DBA vent n W►.e►Bss A&E FIRM UBSCOBPOmT/ON 500 ENTERPRISE DRIVE SUITE 3B ROCKY HILL,CONNECTICUT 1-(860)-529-8882 0-0 po.co r� • V 1 ]� PROPOSED CELLCO PARTNERSHIP ROOF PENETRATION ® ® p -REFER TO 2/Z-2 `�- , E PROPOSED CELLCO PARTNERSHIP ROOF C�9_ .4 d„ EXISTING TELCO CLOSET MOUNTED CABLE SUPPORT TRAY(TIP.) (BELOW) - REFER TO 3/Z-2 C� /✓� h `1\\\'� I I I L- J PROPOSED CELLCO PARTNERSHIP ANTENNAS ON BALLAST MOUNTED FRAME MANUFACTURED BY _____ ❑ NELLO CORPORATION WITHIN PROPOSED 4'-O"x4'-O'x3'-6"HIGH RF TRANSPARENT -_--- ANTENNA SCREEN (TO MATCH EXISTING BUILDING COLOR) EXISTING ROOFfOP� PROJECT NO: 36931 228 - � JOB NO: Wl-203 r� __ _____ _ ❑ pQ DRAWN BY: WRB `EXISTING ROOFTOP .__ o — Q CHECKED BY: ❑ `EXISTING ROOF p ISSUED FOR L..._ DRAIN (ttP.) z 08-04-06 REVIEW L_ J � j6-14-06 Renex V08-15-06 REVIEW REFER TO 4/Z-2 FOR DETAILED 08-23-06 ZONING PLAN OF ANTENNA MOUNTING co ---: o ❑EXISTING EQUIPMENT (TYP.) EDGE OF BUILDING THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO VERIZON WIRELESS IS STRICTLY PROHIBITED. 1 EXISTING HVAC Z-2 VERIZON WIRELESS EQ UIPMENT STORE EXISTING WALKING PADS 9 BUCKLAND ROAD (TYP) SOUTH WINDSOR CONNECTICUT 06&4 SCALE: AS NOTED PARTIAL ROOF PLAN 1 PARTIAL ROOF PLAN Z_1 SCALE: 1/8"=1'-D" III I 1 0 2 4 8 16 32 ^_1 CELLCO PARTNERSHIP DBA \Ve► Zon wireless CONDUIT PROPOSED CELLCO PARTNERSHIP ANTENNAS ON CLAMPING RING WITH WATER-CUT OFF MASTIC BALLAST MOUNTED FRAME MANUFACTURED BY NOTE: A&E FIRM NELLO CORPORATION (TYP.OF 2) CABLE TRAY COVER BE PRE-FABRICATED PIPE SEAL UBSCOBPOBAT/OH IN-SEAM SEALANT P-W INDUSTRIES CABLE 6" 1'-6" 6" LAP SEALANT 500 ENTERPRISE DRIVE o TRAY(OR ENGINEER SUITE 3B a APPROVED EQUAL) CABLE TRAY COVER - 1/2-0 COAXIAL CABLE COAXIAL CABLES(TYP.)W/SNAP-IN HANGERS ROCKY HILL,CONNECTICUT - FOR GPS(TYP.OF 2) COAXIAL CABLE AND ANDREWS SNAPSTAK 1-(860)-529-8882 HANGER KR JSSH-158(TYP.) SELF-TAPPING ^ MICROFLECT B1190 HALFSRRAP W/UNISTRUT �pM�E-SEAI, 1/4"DW0/4"HEX HEAD CAP SCREW AND 0 PROPOSED 4'-0"x4'-0"x3'-6"HIGH RF SCREW�') 1/4"DIA SPRING NUT OYP.)TO SUPPORT/2 �,.(,. C,OJWy�... TRANSPARENT ANTENNA SCREEN (TO MATCH EXISTING ROOF AWG,BARE TINNED COPPER GROUND WIRE. ylJp'p®pp p! r EXISTING BUILDING COLOR) 4"50.FVC SLEEPER O 4-0"O.C.ON EXISTING �V®p. ��� ! RUBBER PROTECTION MAT(TYP.) ROOF SYSTEM p� 2-0 MIN. HORIZONTAL SEPARATION •,:'a ANTENNA MOUNTING PLAN 3 HORIZONTAL CABLE TRAY DETAIL 2 COAX PENETRATION DETAIL ROOFTOP (TYP.)4 # Z-2 SCALE: 3/4" = 1'-0" Z-2 SCALE:3/4" = 1'-0" Z_2 SCALE: NTS 9 PROJECT NO: 36931028 PROPOSED CELLCO PARTNERSHIP ANTENNAS ON BALLAST MOUNTED FRAME MANUFACTURED BY JOB N0: VZ1-203 NELLO CORPORATION PART#103489 WITHIN TOP OF EXISTING PARAPET PROPOSED 4'-0"x4'-0"x3'-6" HIGH RF TOP OF EXISTING ROOF TRANSPARENT ANTENNA SCREEN(TO MATCH DRAWN BY: WRB _. EXISTING BUILDING COLOR) CHECKED BY: TOP OF ANTENNA SCREEN ISSUED FOR 08-04-06 REVIEW 08-14-06 REVIEW TOP OF PARAPET 08-15-06 REVIEW Ffl veri�n wireless THE INFORMATION CONTAINED H IN THIS SET OF DOCUMENTS a IS PROPRIETARY BY NATURE. ;R o N ANY USE OR DISCLOSURE i OTHER THAN THAT WHICH RELATES TO VERIZON IS STRICTLY PROHIBT DIRELESS VERIZON WIRELESS STORE 9 BUCKLAND ROAD SOUTH WINDSOR, CONNECTICUT 06074 SCALE: AS NOTED APPROXMIATE GRADE PARTIAL SOUTH ELEVATION 1 PARTIAL SOUTH ELEVATION Z-2 SCALE: 1/4"= 1'-0" 0 1 2 4 8 16 Z-2