Loading...
HomeMy WebLinkAboutResubdivision (86) TOWN OF SOIITH WINDSOR PLANNING&ZONUFG COMMISSION a w N s e& APPLICATION FORM Fhtion No: l�h-3�, /7 O ' Receipt Date: `�'-/,�-n�) RECEIVED No: :C20 4 APPLICANT: ) f�SEP 7 ���'Sc�e•ct�r��. �I�rJuv,i d {_ E'qn /cl� ADDRESS: OWNER OF RECORD ON LAND RECORDS: q( t1 d� l Z Eetn o ids ADDRESS: COMPLETE LOCATION OF PROPERTY: 0 d 4 7 ASSESSOR'S MAP# PARCEL#_ ZONE R NAME, ADDRESS, TEL&FAX # OF PERSON TO WHOM INQUIRIES SHOULD BE DIRECTED: Rum,, THIS APPLICATION IS FOR: (Check all that apply): ❑ Zone Change to (Public Hearing required and Certified letter to abutters required) ❑ Subdivision/Resubdivision ❑ Open Space Subdivision (Public Hearing Required) ❑ Subdivision ❑Minor ❑ Major Resubdivision (Public Hearing Required) 2 111nor ❑ Major ❑ Conditional Approval ❑ Special Exception to Article (Public Hearing, Certified letter to abutters required) ❑ Site Plan of Development ❑ General Plan of Development ❑ Earth Filling (Sec. 15) and/or Earth Removal (Sec. 14 - Public Hearing required) ❑ Regulation Amendment: ❑Zoning ❑ Subdivision (Attach proposed amendment) Temporary and Conditional Permit for ❑ Major Home Occupation for ❑ Other(explain in detail) An Application Pending sign is required to be posted on the property for all applications ten (10) days Prior to being heard by the Commission. Sign re of App '6mt Signa of Prope caner (See reverse side for additional information) r e TOWN OF SOUTH WINDSOR CHECKLIST OF REQUIRED SUBMISSION DOCUMENTS SUBDMSIONS/RESUBDMSIOINS APPLICANT 10a4n e 670,1 glein o aS PROJECT NAME--& o i IS Su (Y1VISim This checklist must be signed by plan preparer(P.E/L.S) declaring that all required information is provided. Place a check mark for each item supplied. Subdivision Minor Regular I. PROJECT-PLOT INFORMATION A. General Information ✓ 1. Appl. &owner name, address x x 2. Engineer & land surveyor name, address, license no. / &seal x x K ma at 1 = 100 scale showing location of tract 3. Key p g with reference to surrounding properties, streets, municipal boundaries, etc., within 500'. Key map must include: x x V a. Outline of buildings. b. Layout of streets c. Surrounding property boundaries within 500 feet. ✓ d. Names of abutting property owners. e. Proposed open spaces and recreation areas. f. Driveway cuts on abutting properties and any properties across from proposed site r. Subdivision Minor Regular g. Distance to and name of nearest intersection street. 4. A schedule Pg of.re wired and rovided zonin district G , requirements including lot area, lot frontage, lot depth,yard setbacks, open space. variances granted, etc. x x 5. North arrow and scale. x x 6. Appropriate certification block. x x 7. Date of original drawing and all revisions. x x 8. Name of development. x x B. Plot plan at I" = 40'scale-an standard 18"x 24' or 24" x 36"sheets with a 1/2' ruled margin containing the following data. Developments which require more than two 24" x 36" sheets may submit the plot plan at 1" = ` 100' scale. x x 1. Metes and bounds description showing dimensions, bearings, curve data, length of tangents, radii, arcs, chords, and central angles for all centerlines and rights-of-way, and centerline curves on streets. Monuments are,.required at comers and angles of all new streets and new street lines, at all points of curvature and tangency, and at critical corners and angles of all new Town open space. Coordinates for monuments shall be in tabular form. x x 2. CGS datum shall be used on all subdivisions accessible to controls. The Town Engineer shall / determine the accessibility of these controls. `� 3. Lot layout numbers, square footage of all lots, and all lot dimensions. Iron pins are required at all property angle points. No lots shall be divided on 2 t / sheets. x x v 4. Yard setbacks dimensioned. x x /- 5. Easements, noting grantors, grantees and purpose. x x a Subdivision Minor Regular A 6. Development phasing, if proposed. x x 7. Names of abutting property.owners. x x N A 8. Proposed street names (use approved list of names). x x t,14 9. All open space reserved for common or public uses. x x 10. Appropriate A-2 certification & LS seals. x x II Topographic map at same scale as plot plan containing all data included on the plot plan plus the following: 1. All existing structures, streets, wetlands and existing watercourses, or other environmentally structs sensitive areas, including enough data streets x beyond property boundaries to allow a wetlnds reasonable evaluation of the property's fldpin ecological relationship to surrounding areas, 100 yr. floodplain. x 2. Existing and proposed contours to extend a x sufficient amount beyond subject property, to determine the effects on the properly as follows (town mapping): 100' x up to 3% grade: 1'contour interval 3% grade &over; 2'contour interval v 3. Boundary limits, nature, and extent of wooded areas, specimen trees, and other significant physical features. x x 4. Existing system of drainage of subject site and of any larger tract or basin of which it is a part (can use Town stormwater x x study). 5. Drainage area map. * x l��• 6. Drainage calculations * x N�. 7. Perc test data, preliminary indication of septic system feasibility if individual sanitary * x sewerage systems provided. Subdivision Minor Regular 8. Proposed utility infra p ty structure plans, including sanitary sewer. water, storm water management. * X J9. Spot and finished elevations at all property comers, comers of all structures or dwellings, / or proposed first floor elevations x x 10. Construction details (per standard specs.) * x N e. 11. Road and paving cross-sections (per, standard specs). * x 12. Proposed street names. x x V3 A 13. Landscape plan and details. x x hob 14. Site identifications signs, traffic control signs, and - - ! directional signs. * x 15. Sight triangles at new road intersections. * x V 16. Sight triangles at driveway entrance x x (where there may be a question).. a- 17. Vehicular and pedestrian circulation patterns (less detail necessary for preapplications, concept plan, and general plan of development. * x III . Plans and profiles (1" = 40' horizontally and 1" = 4'vertically) showing the following: x N o. a. Layout of streets in sections coordinated by stations with the profile. x N 4 b. Street plan showing roadways, drainage, and partial lot lines x Subdivision Minor Regular c. Profile of roadway showing existing and finished grades, all tangent grades, and all vertical curve information x o- d. Profile will show all catch basins and all drainage lines between catch basins with all invert and top of frame elevations. Drainage pipe material to be described. x e. Typical/critical cross-sections where grading is outside street right-of-way or is at street right- of-way. x f. Where any stone drainage line discharges into an existing brook, sufficient profile of this brook will be shown to determine conditions. x N A g. Profiles shall show all sanitary sewer lines and manholes, including pipe material, elevations, sizes, lengths, and slopes of pipes. Top of foundation elevations for habitable buildings shall be shown. * x NA 15. Traffic report (by traffic engineer) t�tl. 16. Open space site improvement plan. * x IAA 17. Architectural elevations/information per Sect. 4.20 of the zoning regulations * - if required by Town Engineer ALL INFORMATION REQUIRED ABOVE IS INCLUDED IN THIS APPLICATION AT THE TIME OF SUBMISSION. (J` L. • Date q " Co Pre A(PE'e PLANNING DEPARTMENT IN-HOUSE REFERRAL FORM TO: Matt,Galligan, Michael Gantick, Thomas Field, Bill Lanning, John Bond, Ray Favreau, Karl Reichle, Mel Stead, John Collins, Bob Deptula, Jerry Iazzetta FROM: Marcia A. Banach, AICP, Director of Planning The Planning & Engineering De artments have received plans for the following project: " n )9 P Location: 0 Site Plan l Subdivision No. Acres Zone_' tZ O Industrial 0 Commercial Residential No. Lots/Units Water: PJ Public 0 Private Well Sewerage: 'ublic 0 Septic system(s) Project Description: M Future Town-owned property involved? 0 Yes Pr No 0 new street(s) 0 new detention area 0 new open space/recreation area 0 active O passive Planning Department notes: Please comment by `�/J l and return to the Planning Department. "j- Jb MEMORANDUM To: Marcia A. Banach, Director of Planning From: Jerry C. Iazzetta, P.E., Town Engineer Date: September 11, 2000 Re: Reynolds Resubdivision 00-39P We have reviewed the plans dated 8-31-2000 for the proposed Reynolds Resubdivision and have the following comments: 1. Streetline in front of the subdivision should be established in deed and a monument placed at corner of lot 1 and lot 2 along the streetline. 2. Sanitary laterals. a. Laterals for lots 1 and 2 should tie into existing sanitary manhole if possible. b. Why doesn't the lateral for lot 1 tie into manhole in front of lot 1, thereby avoiding the need for an easement. C. Laterals are to be a minimum of 6"diameter. d. Inverts are required at houses. e. Cleanouts are required every 100' of sanitary lateral. 3. Footing drain outlet pipe should drain to rear. Also invert required at house. 4. It is unclear what the depression and pipe under driveway are for. The pipe should be connected to the catch basin in the road if possible, however in any case it should not flow across the neighbor's property. 5. The proposed easement should be identified as to whom granted and identified with bearings and distances and located from a property corner. 6. Is the house on lot 1 existing? If so, it should be identified as existing. 7. The pull-off should be located just beyond the streetline. 8. Existing contours should be darker and have additional labeling of same. 9. Details are required for cleanouts, sanitary and storm pipe trenches, driveway pavement, permanent and temporary pavement patch. 10. Roof leaders not addressed. 11. WPCA approval required. JCl/sfg \\TOWN_HALL\VOL2\ENGINEER\Prof.-P&Z Wetland Applications\Reynolds\Review Sept 11.doc Reynolds Resubdivision Planning Comments All building setback lines must be outside of easement areas Additional information is required regarding the"purported limit of the old abandoned road". Specifically any documentation relating to its abandonment WPCA Comments WPCA approval is required. Applicant must provide a 6 inch lateral connections to main line sewer. Sewer easement should favor lot 1. The building sewer lateral should be installed at a 2%slope. _�� �A� Meehan & Goodin Richard Meehan, LLS Marc Goodin, PE _M_ E. Russell Johnston III, PE W Engineers - Surveyors, P.C. Robert E. Dahn, LLS NOW Arthur J. Falcone, PE Vernon S. Reed,Jr., LLS September 22, 2000 Michele R. Lipe Assistant Director of Planning Town of South Windsor 1540 Sullivan Avenue South Windsor, CT 06074 Re: Response to 9/9/00 Staff Comments Reynolds Subdivision plan Meehan &Goodin job no. 00-039 Dear M. Lipe: This letter shall serve to itemize our detailed response to your staff review letter dated September 19, 2000. The items listed below have been incorporated in the revised drawings submitted to your office. These items are as follows: 1. The corners of the proposed property are noted to receive an iron pin. This will adequately monument the proposed subdivision lot. Note that the drawings are marked I.P. (TBS), Iron pin to be set. 2. The following items are with regard to sanitary laterals shown on the design drawings. a. The house and sewer lateral is existing and noted as such on the revised drawing. b. The lot 1 lateral exists and ties in as shown. This location and tie in is based on as- built information. C. The new lateral has been changed to 6°diameter. d. The invert at the proposed house on lot 2 is now shown. e. One cleanout has been added to comply with the 1 00'spacing of cleanouts. 3. The footing drain and inverts are shown on the revised drawing. 4. The depression and pipe has been designed to eliminate ponding on the westerly side of the driveway. Due to the existing grades the required driveway grading would form a depression. It is not desirable to have storm water sheet-flow across the driveway. 5. The proposed easement has been located on the property and dimensioned with bearing and distances. 6. The house on lot 1 is existing, and noted as such on the revised drawing. 7. The pull-off was moved closer to the street line on the revised drawing. 8. The existing contours were darkened on the revised drawing. 9. Details are provided for cleanouts,sanitarily and storm pip trenches, and driveway pavement. 10. Roof leaders connect to the footing drainpipe as shown on the revised drawing. 11. Are we required to submit to the WPCA directly? If so,we will comply with this requirement. Please do not hesitate to call if you have any questions regarding the items addressed above. ve truly yours, eh n &Goodin, P.C. ur J. Falc n , P.E. Principal—D e or of Structural Engineering Services Cc: Mr.Jerry lazzetta, P. E.,Town Engineer 387 North Main Street Manchester, CT 06040 (860) 643-2520 Email: Info@meehangoodin.com FAX (860) 649-8806 Ago_' Meehan & Goodin Richard Meehan, LLS Marc Goodin, PE —�_ E. Russell Johnston 111, PE W�w Engineers - Surveyors, P.C. Robert E. Dahn, LLS Arthur J. Falcone, PE Vernon S. Reed,Jr., LLS September 22, 2000 1 21 Michele R. Lipe 1 Assistant Director of PlanningCE�VEII Town of South Windsor 1540 Sullivan Avenue EP 2 8 South Windsor, CT 06074 cn Re: Response to 9/9/00 Staff Comments ®;ti Reynolds Subdivision plan Meehan &Goodin job no. 00-039 Dear M. Lipe: This letter shall serve to itemize our detailed response to your staff review letter dated September 19, 2000. The items listed below have been incorporated in the revised drawings submitted to your office. These items are as follows: 1. The comers of the proposed property are noted to receive an iron pin. This will adequately monument the proposed subdivision lot. Note that the drawings are marked I.P. (TBS), Iron pin to be set. 2. The following items are with regard to sanitary laterals shown on the design drawings. a. The house and sewer lateral is existing and noted as such on the revised drawing. b. The lot 1 lateral exists and ties in as shown. This location and tie in is based on as- built information. C. The new lateral has been changed to 6"diameter. d._ The invert at the proposed house on lot 2 is now shown. e. One cleanout has been added to comply with the 1 00'spacing of cleanouts. 3. The footing drain and inverts are shown on the revised drawing. 4. The depression and pipe has been designed to eliminate ponding on the westerly side of the driveway. Due to the existing grades the required driveway grading would form a depression. It is not desirable to have storm water sheet-flow across the driveway. 5. The proposed easement has been located on the property and dimensioned with bearing and distances. 6. The house on lot 1 is existing, and noted as such on the revised drawing. 7. The pull-off was moved closer to the street line on the revised drawing. 8. The existing contours were darkened on the revised drawing. 9. Details are provided for cleanouts, sanitarily and storm pip trenches, and driveway pavement. 10. Roof leaders connect to the footing drainpipe as shown on the revised drawing. 11. Are we required to submit to the WPCA directly? If so,we will comply with this requirement. Please do not hesitate to call if you have any questions regarding the items addressed above. Ve ly yours, eha &Goodin, P Art ur J. Falcon E. Principal—Dire or of Structural Engineering Services Cc: Mr. Jerry.lazzetta, P. E.,Town Engineer 387 North Main Street Manchester,CT 06040 (860) 643-2520 Email: Info@meehangoodin.com FAX(860) 649-8806 MEMORANDUM To: Marcia A. Banach, Director of Planning From: Jerry C. Iazzetta, P.E., Town Engineer Date: September 29, 2000 Re: Reynolds Resubdivision 00-39P We have reviewed the revised plans dated 9-22-2000 for the proposed Reynolds Resubdivision and have the following comments: 1. Streetline in front of the subdivision should be established in deed and a monument placed at corner of lot 1 and lot 2 along the streetline. 2. Footing drain outlet pipe should drain to rear. 3. The pipe under driveway should be connected to the catch basin in the road if possible, however in any case it should not flow across the neighbor's property. 4. Details are required for storm pipe trench, permanent and temporary pavement patch. 5. Roof leaders not addressed. 6. WPCA approval required. 7. The detail for sanitary trench is not the town standard. 8. The proposed easement's boundary lines should be identified differently- they look like the driveway linework. Also the easement label is pointing at contour lines. 9. If roof leaders are connected to the footing drain outlet pipe, the footing drain outlet pipe must be a minimum of 6"and a detail of the connection provided. However, it may be advisable to splash the roof leaders onto splash pads to avoid clogging of the footing drain pipe. JCl/sfg \\TOWN_HALL\VOL2\ENGINEER\Proj.-P&Z Wetland Applications\Reynolds\Review Sept 29.doc Reynolds Resubdivision Public Hearing 10-3-00 1. Request for approval of a resubdivision to create 1 lot on Beelzebub Road, RR zone. 2. Minimum lot size required in the RR zone is one acre; the proposed lot is just over 2 acres. A variance was granted in 1967 to create a lot with 140 feet of frontage, rather than the required 175 feet. 3. There are regulated wetlands on the property; however, no activity is proposed with the regulated areas and IWA/CC approval is not required. There is an easement at the rear of the lot, to the State of Connecticut for flowage rights in connection with the Avery Dam. 4. The site will be serviced by public water and sewer. WPCA approval is required. Also, the grantor and grantee of the sewer easement should be identified on the plan; and the building setback lines should be shown outside of the easement. 5. The plan shows a "purported limit of old abandoned highway." Our Town Attorney has indicated that we need more information regarding this abandoned highway, particularly any documentation regarding the abandonment. This information should be provided before the hearing is closed. If this application is approved, the Planning Dept. requests, in addition to approval modifications already noted, the required zoning data table be provided. G � 9 . 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CONN. 06074 SOR•co AREA CODE 860 / 644-2511 November 14, 2000 CERTIFIED MAIL Mr. &Mrs. Wayne Reynolds 80 Cider Mill Road Ellington, CT 06029 Dear Mr. &Mrs. Reynolds: Re: Appl 00-39, Reynolds Resubdivision We are pleased to advise you that the Planning &Zoning Commission voted on 10/31/00, to approve with modifications application #00-39P, Resubdivision on 2 acres to create 1 lot to be known as Reynolds Resubdivision on property located on 161 Beelzebulb Road, RR zone as shown on plans prepared by Meehan & Goodin, project #99318 and dated 8/31/00, as revised. This approval is subject to the following modifications: 1. This approval is for 1 lot, numbered 2. 2. Drainage and construction for this subdivision is subject to the approval of the Town Engineer. 3. The lot shall be serviced by the Town of South Windsor sanitary sewer system and is subject to the approval of the Water Pollution Control Authority. 4. Water shall be supplied to this subdivision by public water. 5. All plans used in the field by the developer must bear the stamp and authorized signature of the Town of South Windsor. 6. All easements for conservation purposes, drainage or utilities, that may be required in connection with the approval of this subdivision,must be submitted on standard Town easement form where appropriate, to this Commission prior to filing the mylars and issuance of building permits. All deeds for open space,public'improvements and roadways must be submitted prior to request for Town acceptance; all deeds must be in accordance with the policy for accepting deeds and must be approved by the Engineering Department and Town Attorney. 7. Footing drains are required for each house. Prior to the building of any structure on a lot, a topographic map, drawn to a scale of 1" =40', shall be submitted for each lot in the subdivision, showing proposed contours, elevations and the location of the footing drains. No building permits will be issued until the proposed contours, floor elevations and location of footing drains have been approved by the Town Engineer. 8. If, for any reason, finished grading and other individual lot site work is not completed, the Town Engineer shall determine the amount of a cash bond to ensure final grading and site work. This cash bond must be submitted prior to issuance of a Certificate of Occupancy. 9. Quantity estimates must be submitted to the Town Engineer(on the enclosed form) for the purpose of determining subdivision bonding. All bonds shall conform to the enclosed bond policy and shall be posted prior to filing the final plans in the Town Clerk's office. If the developer chooses to submit a Letter of Credit for a one year term, said Letter of Credit must be renewed on a yearly basis until completion of the development. If a new Letter of Credit has not been received within 30 days before the expiration date, the Commission may, at its option, call the Letter it is holding. 10. A drainage assessment fee in the amount of$50.00 shall be submitted to this Commission. 11. No building permits will be issued until all modifications have been complied with, and the final plans have been filed in the Town Clerk's office. 12. The Commission's approval is conditioned upon the Town's reliance upon representations made by the applicants that they own the property involved in the application and that they will not interfere with property rights of others by using their property as proposed in the application. 13. Required zoning data table must be provided. 14. Town Engineer's comments dated September 29, 2000,must be addressed to the Town Engineer's satisfaction. Black and white transparent mylars of Sheets#2 with the above modifications, together with three blueprint copies of the entire set of plans (including architectural elevations)must be submitted to this Commission within 30 days to be stamped and signed. The letters of approval of this Commission, as well as the Inland Wetlands Agency/Conservation Commission,must be reproduced on the mylars. After mylars have been signed by the Commission, they will be returned to you for filing in the Office of the Town Clerk by February 17,2001. After filing these plans, a copy of the receipt must be submitted to the Planning Department. Sincerely, Walter J. Mealy, Chairman Planning and Zoning Commission Enclosures cc: Town Engineer Chief Building Official Assessor Superintendent of Pollution Control Fire Marshal Board of Education �towa af,�� O Y Ga ' Wn Cl7 V�OZL • s . 1540 SULLIVAN AVENUE SOUTH WINDSOR, CONN. 06074 R•c� AREA CODE 860/644-2511 December 19, 2000 Mr. & Mrs. Wayne Reynolds 80 Cider Mill Road Ellington, CT 06029 Dear Mr. & Mrs. Reynolds: Re: Appl 00-39, Reynolds Resubdivision Please be advised that the Planning & Zoning Commission voted on December 12, 2000, to grant a 90-day extension for filing subdivision plans for the above-referenced subdivision in the Town Clerk's office. The original filing deadline was; the new filing deadline is May 18, 2001. State statutes authorize one additional 90-day filing extension. If you wish to request an additional extension, please request in writing prior to that date. Very truly yours, ala_4&L g. -�a,� Walter J. Mealy, Chairman Planning and Zoning Commission WJM/dlf RECEIVI- 0 REYNOLDS FINANCIAL SERVICES INVESTMENTS-INSURANCE-RETIREMENT PLANS DEC ?'J (860)875-1475 Toll Free(877)295-1310 Fax(860)875-1475 December 6, 2000 Town of South Windsor Planning Department 1540 Sullivan Avenue South Windsor, CT 06074 Dear Planning Department Representative, Because of some delays in working with the engineer, would you please ant us a 90 day extension to file the required mylars on the Reynolds Resubdivisio , Appl 00-39:'Thank you for your assistance on this request. -- Sincerely, W e L. RIs ail L. Reynolds Securities offered through Commonwealth Financial Network,Member NASD, SIPC _AMA —A— Meehan & Goodin Richard Meehan, ILLS —�_ Marc Goodin, PE E. Russell Johnston III, PE W Engineers - Surveyors, P.C. Robert E. Dahn, LLS NAIW Arthur). Falcone, PE Vernon S. Reed,Jr., LLS December 21, 2000 Mr. Jerry C. lazzeta, P.E. " Town Engineer Town of South Windsor 1540 Sullivan Avenue South Windsor, CT 06074 Re: Survey Monumentation of Street Line Reynolds 1 Lot Subdivision Meehan &Goodin job no. 99-318 Dear Mr. lazzeta: The purpose of this letter is to inform you that we have set the proposed iron pin in the northeasterly comer of the proposed new lot. As of the date of this letter our firm has set location ties to the proposed concrete monument that has not yet been installed. It is our intent to place the permanent concrete monument as soon as weather permits. We hope that the work done to date, including the statements made in this letter will be sufficient for approval of the subdivision. If there are any further questions regarding placement of the boundary monuments, please do not hesitate to call either Bob Dahn, or myself at 643- 2520. Very truly yours, Meehan&Goodin, P.C. J t Arthur J. Falcon , P.E. Principal— Director of Structural Engineering Services 387 North Main Street Manchester, CT 06040 (860) 643-2520 Email: Info@meehangoodin.com FAX(860) 649-8806 �)d 3 SOVIM •e, C ~ TIOW-n 0_,teSVadl ?d 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CT 06074 soe.co� TELEPHONE (860) 644-2511 January 10,2001 Wayne Reynolds 80 Cider Mill Road Ellington,CT 06029 RE: Approval to Connect—Reynolds Subdivision Beelzebub Road South Windsor,CT Dear Mr.Reynolds The South Windsor Water Pollution Control Authority,at its regular meeting of January 2,2001,gave approval for the connection to the Town's sewerage system of a residential lot for a single family residence to be built on Lot#2 located east of 161 Beelzebub Road,as more specifically shown on plans entitled "Key Map and Subdivision Plan",prepared by Meehan&Goodin,Project No.99318,Drawing No(s). 1 dated 8-31-200 with no revisions and Drawing No.2 dated 8-31-2000,with revisions dated 9-22-00 and 11-29-00 and subject to the following conditions: 1. Technical approval of the Town Engineering Department. 2. Final Authority approval and acceptance of the sanitary sewerage connection will be given once the sewer line has been installed and inspected by the Town staff,and based upon the written verification of the Town staff that said sanitary sewer line was installed in substantial conformance with the design plans previously approved by the Authority,and meeting all Town regulations and appropriate technical specifications relating to sanitary sewer construction. This approval letter must be superimposed on the final approval plans. Very truly yours, o Hilids6n,Chairman Water Pollution Control Authority TH:dd CC:Matthew Galligan,Town Manager Michael J.Gantick,Director of Public Works Jerry Iazzetta,Town Engineer Marcia Banach,Director of Planning John Collins,Chief Building Inspector Meehan&Goodin,Engineers