Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Site Plan of Development (61)
TOWN OF SOUTH WINDSOR PLANNING&ZONING COMMISSION ow N s q` APPLICATION FORM /- Application No: Official Receipt Date: Receipt No: ��.�t}r�' APPLICANT: /�i U�Y 9` f�/>zi4W Al/ Re r/I1I" �Q41/°. //lam ADDRESS: -30c) ��/� ST' $, 0/N/l75769,oie CT 04;071 , OWNER OF RECORD ON LAND RECORDS: 5**g1i ADDRESS: -3©o R -"/c - COMPLETE LOCATION OF PROPERTY: ASSESSOR'S MAP # I zZ PARCEL# 8_ ZONE NAME, ADDRESS, TEL & FAX # OF PERSON TO WHOM INQUIRIES SHOULD BE DIRECTED: p'# Z Fr Z>o 7I X 43S-7 �{745- THIS APPLICATION IS FOR: (Check all that apply): ❑ Zone Change to (Public Hearing required and Certified letter to abutters required) ❑ Subdivision/Resubdivision ❑ Open Space Subdivision (Public Hearing Required) ❑ Subdivision ❑ Minor ❑ Major ❑ Resubdivision (Public Hearing Required) ❑ Minor ❑ Major ❑ Conditional Approval ❑ Special Exception to Article (Public Hearing, Certified letter to abutters required) Site Plan of Development ❑ General Plan of Development Earth Filling (Sec. 15) and/or Earth Removal (Sec. 14 - Public Hearing required) ❑ Regulation Amendment: ❑Zoning ❑ Subdivision (Attach proposed amendment) Temporary and Conditional Permit for ❑ Major Home Occupation for ❑ Other (explain in detail) An Application Pending sign is required to be posted on the property for all applications ten (10) days prior to being heard by the Commission. ignature of ApplicaAt igna re of Property Owner (See reverse side for additional information) r TOWN OF SOUTH WINDSOR CHECKLIST REQUIRED INFORMATION SITE PLANS APPLICANT �Va PROJECT NAME ��20 ©� r3 v ctd'�c•(�G -OQ�Tc�� This checklist must be signed by plan preparer (P.E./L.S.) declaring that all required information is provided. Items 1-7 are required for all applications; items 8-11 required where appropriate. Check mark for each item supplied. 1. On each sheet for plans or maps, title block with the following information: a. Name, address and telephone of applicant. b. Name, address and telephone number of Land Surveyor or Professional Engineer. c. Name of Development. d. Date when drawings were made. _(Z 2. Key Map: An overall map drawn to a scale of 1 inch equals either 100 feet or 200 feet. This map will show the overall design of the Development and surrounding property within 500 feet. a. Data block which gives needed zoning information such as percentage of lot coverage, acreage of tract, number of apartment units, parking requirements, etc. b. Outline of buildings. c. Layout of streets. L d. Surrounding property boundaries-within 500 feet. �L e. Names of abutting property owners. f. Proposed open spaces and recreation areas. g. Driveway cuts on abutting properties and any properties across from proposed site. V h. Distance to and name of nearest intersection street. l 3. Architectural Elevations: See attached checklist for Architecture and Design Review. J� 4. Plot Plan: A layout map of the proposed site drawn to a scale of 1 inch equals 40 feet on either of the following size sheets: (1) 24" x 36" with a 3/4" ruled margin; (2) 18" x 24" with a 1/2" ruled margin, containing the following data: 1S a. Distance and bearings of all boundary lines and acreage of site. Iron pins required at all property angle points and shown on map. b. Proposed streets and street lines with center line station, curve data, and parking spaces. c. Building lines in accordance with zoning regulations. d. Proposed buildings and other structures, including signs, outside lighting, and dumpsters (on concrete pad and screened). e. Easements, noting grantors, grantees, and purpose. _ f. Names of abutting property owners. g. Monuments will be indicated at corners and angles of all streets and at all points of curvature and tangency. The monumented points within proposed site shall be coordinated. These coordinates shall appear in tabular form on the plot plan. The accessibility of these CGS points shall be determined by the Town Engineer. h. All open space or other common or public land uses shall be indicated. i. A-2 certification; P.E./L.S. seals and signatures. 5. -Topographic Map: A map drawn to a scale of 1 inch to 40 feet on sheets not exceeding 24 inches by 36 inches, including ruled margins shall in addition to the requirements of the plot plans show the following: a. All existing and proposed buildings. b. Curb Lines and pavement width, sidewalks. c. Existing and jr4�ese6 sanitary sewers. _1Z d. Existing and ftpOe4 water and-all existing utilities. e. Present wooded area indicated by foliage lines. Any trees to be saved should be shown. f. Existing and proposed contours shall be shown in not less than two-foot intervals, but in cases of relatively level land, the contours shall be one- foot intervals and spot elevations. g . Regulated wetlands and 100-year floodplain or note that none are present. h. Proposed storm drainage system, showing all catch basins, endwalls, manholes, lengths and sizes of pipes and elevations of structures. (Maximum distance between catch basins shall be 300 feet and minimum size of storm drain lines shall be 15 inches, within Town ROW.) If plan/profile sheet is provided all of this does not need to be shown. Only top of frame elevations and inverts of open discharge pipe shall be shown on this plan. i. Connections of all springs into proposed storm drainage system as needed. j. Location and indications of existing brook channels, and 100-year flood limits. k. A-2 &T 2 Certification; P.E./L.S. seals and signatures. 6. Landscaping plan: 17�Drainage calculations: - Zero Runoff Increase per attached guidelines. .Traffic Report: 9. Plans and Profiles: A plan and profile of the proposed streets drawn on plan/profile paper of scales 1 inch to 40 feet horizontally, and 1 inch to 4 feet vertically on sheets not exceeding 24 inches by 36 inches, including ruled margins and containing the following: a. Layout of streets in sections coordinated by stations with the profile. b. Street plan showing roadways, drainage, sanitary sewer (including house sewer), foundation drains, lot lines, buildings including all utilities with elevations (top frame and inverts), size, type, length, slopes of pipes. c. Sight line at driveway &street intersections. d. Profile of roadway showing existing and finished grades. Roadway profile will show all tangent grade and all vertical curve information. e. Profile will show all catch basins and all drainage lines between catch basins with all invert and top of frame elevations, sizes, lengths and slopes of pipes. • y , f. Where any storm drainage line discharges into an existing brook sufficient profile of this brook will be shown to determine conditions. g. CGS datum shall be used on all sites accessible to these controls. The Town Engineer shall, based on'standard engineering practices, determine the accessibility of these controls. h. Profiles shall show all sanitary sewer lines and manholes, including elevations, inverts, top of frame, sizes, lengths, and slopes of pipes. Top of foundation elevations for building shall be shown. 10. Open Space Site Improvement Plans: For sites which require or include a provision for open spaces, a plan which contains data for site improvement may be required. This map shall be drawn to a scale of 1 inch equals 40 feet. 11. Sanitary Report: Where individual sanitary sewage disposal systems are proposed, the final plans shall include a Sanitary Report certified by a Professional Engineer. The report shall demonstrate the feasibility of the proposed individual systems. PLAN REPARER (P.E./ . .) DATE June 23, 1998 PLANNING DEPARTMENT IN-HOUSE REFERRAL FORM TO: Matt Gallig Fre S , Michael Gantick, Thomas Field, Bill Lanning, John Bond, Ray Favreau, Karl Reichle, Mel Stead, John Collins, Bob Deptula FROM: Marcia A. Banach, AICP, Director of Planning The Planning & Engineerin Departments have received plans for the following project: Location: eLl ------------- Site Plan ❑ Subdiv # Acres —._._ Zone ..1r dustrial ❑ Commercial ❑ Residential # Lots/Units Water: 17 Public ❑ Private Well Sewerage: 17 Public ❑ Septic stem s Project Description: Future Town-owned property involved? ❑ Yes 0 ❑ new street(s) ❑ new detention area ❑ new open space/recreation area ❑ active ❑ passive Planning Department notes: Please comment by (feel free to use this form); return to Planning Department. Thank you. G -�o- 59 3 G STANDARD']APPROVAL MODIFICATIONS FOR SITE PLAN PROJECT 1 J; t u APPL. # � ENGINEER/ARCHITECT PROD. # ❑ 1. Prior to commencement of any site work, a meeting must be held with Town Staff. 2. No building permit will be issued until the final mylars have been filed in the Town Clerk's office. ❑ 3. This application is subject to the conditions of approval of the Inland Wetlands Agency/Conservation Commission, including a bond in the amount of $ 4. An an-built plan is required prior to issuance of a Certificate of Occupancy per Section 8.1.10 of the Zoning Regulations. 5. Footing drains are required if the building has a basement. ❑ 6. A landscape bond in the amount of $ is required and must be submitted prior to filing of mylars. 7. All plans used in the field by the developer must bear the stamp and authorized signature of the Town of South Windsor. ❑ 8. WPCA approval is required. 9. If a State Traffic Commission certificate is required, no building permits will be issued until the certificate has been issued (per CGS §14-311). PLANNING DEPARTMENT TRANSMITTAL DATE: 7/�/I� �r?t.Yvt ,t�cre,ci WE ARE SENDING YOU: PZC initial plans O Drainage computations O PZC revised plans O Bond estimate request O PZC Final plans for review O Bond reduction request O PZC Final plans for filing O Correspondence O IWA/CC plans 4 Other 0- J L, NO.OF COPIES APPLICATION NUMBER PROJECT/APPLICANT THESE ITEMS ARE TRANSMITTED: AFor review and comment - O For your files O For your use O As requested 1 8 3 O Other 1N PLEASE RETURN/COMMENT BY: '1► COMMENTS: 666j 9 ,7 jiP 7/is/ o .." Cb 8 � Copy to: From: Planning Department artment- 10/98 tpr1N d�� �-0 u-n o-SoaA ` di m 1540 SULLIVAN AVENUE• SOUTH WINDSOR,CT 06074.2786 OR.CO AREA CODE 860/644.2511 FAX 860/644-3781 CERTIFIED MAIL July 14, 1999 Handy & Harman Refining Group, Inc. James Chapman, Chief Engineer 300 Rye Street South Windsor, CT 06074 Dear Mr. Chapman: Re: Appl #99-49, Handy & Harman Site Plan We are pleased to advise you that the Planning & Zoning Commission approved on July 8, 1999, the above referenced application for a Site Plan of Development. This approval is for the construction of a 5,000sq. ft. addition on property located at 300 Rye Street; I zone, as shown on plans prepared by Close, Jensen& Miller, P.C., Job No. 36902, 6/30/99, as revised. This approval is subject to the following modifications: 1. No building permit will be issued until the final mylars have been filed in the Town Clerk's office. 2. An as-built plan is required prior to issuance of a Certificate of Occupancy per Section 8.1.10 of the Zoning Regulations. 3. Footing drains are required if the building has a basement. 4. All plans used in the field by the developer must bear the stamp and authorized signature of the Town of South Windsor. 5. If a State Traffic Commission certificate is required, no building permits will be issued until the certificate has been issued (per CGS §14-311) Black and white transparent mylars of Sheet#2 with the above modifications, together with three blueprint copies of the entire set of plans must be submitted to this Commission within 30 days to be stamped and signed. The letters of approval of this Commission as well as the Inland Wetlands Agency/Conservation Commission must be reproduced on the mylars. After the mylars have been signed by the Commission, they will be returned to you for filing in the Office of the Town Clerk. After filing these plans, a copy of the receipt must be submitted to the Planning Department. Sincerely, 771a4 ua Zee'n Marcia Banach Director of Planning MB/dlw cc: Town Engineer Chief Building Official Assessor Superintendent of Pollution Control Fire Marshal Ed Fabrizzio, via fax