Loading...
HomeMy WebLinkAboutSite Plan of Development (42) TOWN OF SOUTH WINDSOR, CONNECTICUT R ECEIVED PLANNING & ZONING COMMISSION APPLICATION FORM Application No..: �'V3P AR 171..998 Date Received: Action/Receipt No. Hearing by: KANNNS DEPT. APPLICANT: D `t 1/�/I I GJ I I ] ) ADDRESS: V V i( d w o f o OWNER OF RECORD ON LAND RECORDS 962 l'-1- V,0 ADDRESS: -S ►t ci at> o_J DY COMPLETE LOCATION OF PROPERTY: Assessor's Map. # {�g Parcel: # 7ZJ Zone_ NAME, ADDRESS,. & TEL FAX # OF PERSON TO WHOM INQUIRIES SHOULD BE-� : OOQ 1 DIRECTED _ r r .:_b� �D J7 1 I-l�I fo b �0 +�I THIS APPLICATION IS FOR: (Check all that apply) . bVT i 1 �{i� � CA �(0Q? 1. Zone Change to (Public Hearing required) : 2. Subdivision/Resubdivision a. _ Subdivision Minor Major b. _ Resubdivision _ .Minor Major (Public Hearing_Required) c. — Conditional Approval d. -Open Space Subdivision (Public Hearing Required) _3. Special Exception to.Article (Public Hearing Required) 4. Site Plan of Development _5. General Plan of Development _6. Earth Filling (Sec. 151 and/or Earth Removal (Sec. 141 (Public Hearing Req) _7. Regulation Amendment: Zoning _. Subdivision: _8. Amendment to Town Plan of Development _9_ Temporary and,Conditional Permit XI0. Other (explain in detail) : M 0 W �5wa 1) .AdJ-.{ Applicant Property Owner. (See reverse side for additional information) TOWN OF SOUTH WINDSOR CHECKLIST REQUIRED INFORMATION SITE PLANS APPLICANT PROJECT NAME This checklist must be signed by plan prep arer (P.E./L.S.)-•dec.)aring that.all.required information is provided. Items 1-7 are required for all applications; items:#=1:1:required where.appropriate. Check mark for each item supplied. 1. On each sheet for plans or maps, title block with the following information: a. Name, address and telephone of applicant. b. Name, address and telephone number of Land Surveyor or Professional Engineer. c. Name of Development. Jd. Date when drawings were made. 2. Key Map: An overall map drawn to a scale of 1 inch equals 200 feet, which can be used as an overlay on Metropolitan District Maps. This map will show the overall design of the Development and surrounding property within 500 feet. a. Date block which gives needed zoning information such as percentage of lot coverage, acreage of tract, number of apartment units, parking requirements, etc. b. Layout of buildings. c. Layout of streets and parking. Jd. Lines indicating proposed drainage system with direction arrows. NA e. Lines indicating sanitary sewer system with direction arrows. f. Names of surrounding property owners. g. Proposed.open spaces and recreation areas. h. Driveway cuts on surrounding properties. 3. Architectural Elevations: See attached checklist for Architecture and Design Review. 4. Plot Plan: A layout map of the proposed site drawn to a scale of 1 inch equals 40 feet on either of the following size sheets: (1) 24" x 36" with a 3/4" ruled margin; (2) 18" x 24" with a 1/2" ruled margin, containing the following data: a. Distance and bearings of all boundary lines and acreage of site. Iron pins required at all property angle points and shown on map. b. Proposed streets and street lines with center line station, curve data, and parking spaces. c. Building lines in accordance with zoning regulations. d. Proposed buildings and other structures, including signs, outside lighting, and dumpsters (on concrete pad and screened). �Ti e. Easements, noting grantors, grantees, and purpose. ✓ f. Names of abutting property owners. ✓ g. Monuments will be indicated at corners and angles of all streets and at all points of curvature and tangency. In areas accessible to Metropolitan District Commission points, or other coordinated points, the monumented points within proposed site shall be coordinated. These coordinates shall appear in tabular form on the plot plan. The accessibility of these MDC points shall be determined by the Town Engineer. h. All open space or other common or public land uses shall be indicated. i. A-2 certification; P.E./L.S. Seal. 5. Topographic Map: A map drawn to a scale of 1 inch to 40 feet on sheets not exceeding 24 inches by 36 inches, including ruled margins shall in addition to the requirements of the plot plans show the following: a. All existing and proposed buildings. J b. Curb Lines and pavement width, sidewalks. c. Existing and proposed sanitary sewers. d. Existing and proposed water and gas main systems. Je. Present wooded area indicated by foliage lines. Any individual trees to be saved should be shown. .J f. Existing and proposed contours shall be shown in not less than two-foot intervals, but in cases of relatively level land, the contours shall be one-foot intervals and spot elevations. J S. Regulated wetlands and 100-year floodplain or note that none are present. h. Proposed storm drainage system, showing all catch basins, endwalls, manholes, lengths and sizes of pipes. (Maximum distance between catch basins shall be 300 feet and minimum size of storm drain lines shall be 15 inches. / i. Connections of all springs into proposed storm drainage system as needed. j. Location and indications of existing brook channels, and 100-year flood limits. k. A-2 Certification; P.E./L.S. Seal. 0�A_ 6. Landscaping plan: N 7. Drainage calculations: - Zero Runoff Increase per attached guidelines. N�A 8. Traffic Report: - 2 - 9. Plans and Profiles: A plan and profile of the proposed streets drawn on plan/profile of scales 1 inch to 40 feet horizontally, and 1 inch to 4 feet vertically on sheets not paper Y Y exceeding 24 inches by 36 inches, including ruled margins and containing the following: a. Layout of streets in sections coordinated by stations with the profile. b. Street plan showing roadways and drainage. c. Sight line at driveway & street intersections. d. Profile of roadway showing existing and finished grades. Roadway profile will show all tangent grade and all vertical curve information. e. Profile will show all catch basins and all drainage lines between catch basins with all invert and top of frame elevations. Drainage lines will be shown and described as to material. f. Where any storm drainage line discharges into an existing brook sufficient profile of this brook will be shown to determine conditions. g. Metropolitan District Commission datum shall be used on all sites accessible to these controls. The Town Engineer shall, based on standard engineering practices, determine the accessibility of these controls. h. Profiles shall show all sanitary sewer lines and manholes, including elevations, sizes, lengths, and slopes of pipes. Top of foundation elevations for building shall be shown. N 10. Open Space Site Improvement Plans: For sites which require or include a provision for open spaces, a plan which contains data for site improvement may be required. This map shall be drawn to a scale of 1 inch equals 40 feet. 1 ' 11. Sanitary Report: Where individual sanitary sewage disposal systems are proposed, the final plans shall include a Sanitary Report certified by a Professional Engineer. The report shall demonstrate the feasibility of the proposed individual systems; the report should deal with the area as a whole, discussing the following points: a. General nature and development of surrounding area. b. Topography and natural drainage pattern. c. Subsurface conditions as shown by subsurface investigation, including soil absorption characteristics, ground water level conditions, ledge rock, and general nature of soil. d. General description of type of development contemplated. e. Detailed description of proposed sanitary sewage disposal facilities, indicating sizes for various ground conditions, materials to be used, and the general layout pattern to be used, etc. f. Special precautions that may be necessary to provide proper functioning of the proposed disposal systems. g, map of general area with locations of all tests shown on proposed layout. h. Flood heights of any nearby streams, brooks, or rivers. - 3 - i. Test results and engineering evaluation per Section 4.13.5. All information required above is included in this application at the time of submission. . A r17,=995 -4 LETTER OF TRANSMITTAL 400+ •tot O � 9 V PLANNING DEPARTMENT TOWN OF SOUTH WINDSOR 0 SULLIVAN A 154 VENUE SOUTH WINDSOR, CT 06074 DATE TO : WE ARE SENDING YOU : plans P & Z initial p Drainage comps Bond estimate requests P & Z final plans Bond reduction requests IWA/CC plans Change order form Final plans for filing Correspondence Other 1 . No. Project Copies APP THESE ARE TRANSMITTED as checked below: For review and comment For your fileReturned with revisions For your use As requested Other PLEASE RETURN/COMMENTS BY: COMMENTS : From: Copy to : S0*N Sp 0 e /- ? U Wn OPS C J -GU4A 40t;nd6at afi 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CONN. 06074 �ftioSOR co��� AREA CODE 860/644-2511 May 4, 1998 Certified Mail Robert Delisle Metals Testing Company 80 Kimberly Drive South Windsor, CT 06074 Dear Mr. Delisle: Re: Appl #98-23P, Metals Testing Company Site Plan Modification We are pleased to advise you that the .above referenced application for a Site Plan Modification on property located at 80 Kimberly Drive, I zone as shown on plans prepared by Design Professionals, Job No. 89-413 and revised through April 16, 1998, is hereby approved. This approval is subject to the following modifications: 1. No building permit will be issued until the final mylars have been filed in the town Clerk's office. 2. An as-built plan is required prior to issuance of a Certificate of Occupancy per Section 8.1.10 of the Zoning Regulations. 3. Footing drains are required if the building has a basement. 4. All plans used in the field by the developer must bear the stamp and authorized signature of the Town of South Windsor. Black and white transparent mylars of Sheet 2 with the above modifications, together with three blueprint copies of the entire set of plans must be submitted to this Commission within 30 days to be stamped and signed. The letters of approval of this Commission must be reproduced on the mylars. After the Commission has signed the mylars, they will be returned to you for filing in the Office of the Town Clerk by August 15, 1998. After filing these plans, a copy of the receipt must be submitted to the Planning Department. Very truly yours, We Marcia A. Banach, AICP Director of Planning MAB/pmm Cc: Town Engineer Chief Building Official Assessor Superintendent of Pollution Control Fire Marshal Design Professionals, Inc. + K