Loading...
HomeMy WebLinkAboutSITE PLAN (126) TOWN OF SOUTH WINDSOR, CONNECTICUT PLANNING ANO ZONING COMMISSION _ APPLICATION FORM AUG 11 1989 A NO. U6"r App. IMPORTANTd� SOUth Windsor Date Received: anning & Zoninn Comm Sion ACtiO/ or Public Hearing By; Planning and Engineering Department sta f fq'`X require 14 days to determine application Receipt No. completeness. To ensure receipt of a complete application by PZC, it is strongly recommended that the application be submitted 14 days prior to the Regular Meeting at which-J.' r''= it will be received. • APPLICANT: Prince Associates (Suburban Printers) ADDRESS: 388 Strong Road, South Windsor, CT 06074 TELEPHONE: 289-4371 OWNER OF RECORD ON LAND RECORDS: Ralph Harris & Philip Henshaw (Pri nnP Aggru-_) ADDRESS: 388 Strong Road, South Windsor, CT 06074 COMPLETE LOCATION OF PROPERTY: 388 Strong Road, approximately-450 feet east of Nutmeg Road North ZONE: Industrial NAME, ADDRESS & TELEPHONE NUMBER OF PERSON TO WHOM INQUIRIES SHOULD BE DIRECTED: Peter R. DeMallie, Principal, Design Professionals, Inc. 1170 Ellington Road, South Windsor, CT 06074 TELEPHONE: 291-8755 THIS APPLICATION IS FOR: (Check one of the following) 1. Zone Change to (public hearing required) 2. Subdivision 3 . Open Space Subdivision (public hearing required) 4. Resubdivision (public hearing required) 5. Special Exception to Article (public hearing required) X 6. Site Plan of Development 7 . Earth Filling (Section 10) and/or Earth Removal (Section 9) (public hearing required) 8. General Plan of Development 9 . Regulation Amendment: Zoning Subdivision 10 . Other (explain in detail) THIS APPLICATION MUST BE SIGNED BY THE APPLICANT AND OWNER OF THE PROPERTY AND SUBMITTED IN TRIPLICATE WITH SIX SETS OF THE MAPS (7 if public hearing is ' re ) AND THER DOCUMENTS (see pag ?�—�cj-�� I Applica Owner 1/14/87 (see reverse side) TOWN OF SOUTH WINDSOR, CONNECTICUT - PLANNING AND ZONING COMMISSION APPLICATION FORM This application is complete and ready for Planning & Zoning Commission receipt only upon submission of all required documentation, including, but not necessarily limited to, the following items. Not all items are required with every application. See applicable sections of the South Windsor zoning and subdivision regulations for specific requirements. APPLICATION. CHECKLIST 1. Key Map 2. Architectural Elevations/Floor Plans 3. Completed application form (in triplicate) 4. Required fees 5. Zone Change, Site Plan, Subdivision, Open Space Improve- ment, and/or General Plan of Development maps, in accordance with regulations. (Six sets - seven if public hearing required) 6. Plans & Profiles/Drainage Calculations 7. Conservation Plan 8. Landscaping Plan 9 . Traffic Engineering Report 10. Narrative Statement 11. Sanitary Report 12. Copy of agreement to purchase land (if not the owner) 13. Other ALL PROSPECTIVE APPLICANTS ARE URGED TO CONFER WITH TOWN PLANNING DEPARTMENT AND ENGINEERING BUREAU STAFF PRIOR TO SUBMISSION OF ANY APPLICATION TO THE COMMISSION. CONSULT PLANNING DEPARTMENT FOR FEE SCHEDULE. 1/14/87 South Windsor CHECKLIST REQUIRED INFORMATION 'L+• � � ��� SITE PLANS AUG FlaI7171., . 4h t' fldsor This checklist must be signed by plan preparer (P . E. /L. S . ) declarif�r C� Zo �' mmfssi. that all required information is provided . Items 1-7 are required for all applications ; items 8-11 required where appropriate. Check mark for each item supplies . 1 . On each sheet for plans or maps , title block with the following information : V a. Name , address and PP telephone of applicant . P b . Name , address and telephone number of Land Surveyor or Professional Engineer . C . Name of Development . d . Date when drawings were made . 2 . Key Map : An overall map drawn to a scale of 1 inch equals 200 feet , which can be used as an overlay on Metropolitan District Maps ._ This map will show the overall design of the Development and surrounding property within 500 feet . V a. Data block which gives needed zoning information such as percentage of lot coverage, acreage of tract , number of apartment units, parking requirements , etc . V b . Layout of buildings C . Layout of streets and parking . d . Lines indicating proposed drainage system with direction arrows . e . Lines indicating sanitary sewer system with direction arrows . f . Names of surrounding property owners . g . Proposed open spaces and recreation areas. h . Driveway cuts on surrounding properties . 3. Architectural Elevations : Plans of the proposed buildings drawn to a scale of 1/8" = 1 ' - 0" showing the elevations of all sides of the proposed buildings in sufficient detail to show architectural styling . Architect ' s seal on elevations for buildings in excess of 5000 square feet ( per CGS Chapter 390) . Page 2 (Site plans) 4 . Plot Plan : A layout map of the proposed site drawn to a scale of 1 inch equals 40 feet on either of the following size sheets: ( 1 ) 24" X 36" with a 3/4" ruled margin ; ( 2) 18" X 24" with a 1/2" ruled margin , containing the following data: a. Distance and bearings of all boundary lines and acreage of site . Iron pins required at all property angle points and shown on map. ✓ b . Proposed streets and street lines with center line stations , curve data , and parking spaces . ✓ C . Building lines in accordance with zoning regulations . V d . Proposed buildings and other structures , including signs , outside lighting , and dumpsters (on concrete pad and screened) V e. Easements , noting grantors , grantees , and purpose. f . Names of abutting property owners . _ g . Monuments will be indicated at corners and angles of all streets and at all points of curvature and tangency . In areas accessible to Metropolitan . District Commission points , or other coordinated points , the monumented points within proposed site shall be coordinated . These coordinates shall appear in tabular form on the plot plan . The accessibility of these MDC points shall be determined by the Town Engineer . h . All open space or other common or public land uses shall be indicated . i . A-2 certification ; P . E. /L. S . Seal . S. Topographic Map : A map drawn to a scale of 1 inch to 40 feet on sheets not exceeding 24 inches by 36 inches , including ruled margins shall in addition to the requirements of the plot plans show the following: a . All existing and proposed buildings . b . Curb lines and pavement width , sidewalks. C . Existing and proposed sanitary sewers . d . Existing and proposed water and gas main systems . e . Present wooded area indicated by foliage lines . Any individual trees to be saved should be shown. Page 3 (Site Flans ) f . Existing and proposed contours shall be shown in not less than two-foot intervals , but in cases of relatively level land , the contours shall be one-foot intervals and spot elevations . g . Regulated wetlands and 100-year floodplain or note that none are present . h. Proposed storm drainage system, showing all catch basins , endwalls , manholes , lengths and sizes of pipes . (Minimum distance between catch basins shall be 300 feet and minimum size of storm drain lines shall be 15 inches . ) i . Connections of all springs into proposed storm drainage system as needed. V j . Location and indications of existing brook channels , and 100-year flood limits . V/ k. A-2 Certification ; P . E. /L. S , Seal . _L 6. Landscaping plan . 7 . Drainage calculations - Zero Runoff Increase per attached guidelines . . 8 . Traffic report . 9 . Plans and Profiles : A plan and profile of the proposed streets drawn on plan/profile paper of scales 1 inch to 40 feet horizontally , and 1 inch to 4 feet vertically on sheets -not exceeding 24 inches by 36 inches , including ruled margins and containing the following : _i #4 a. Layout of streets in sections coordinated by stations with the profile . NA b . Street plan showing roadways and drainage. C . Sight line at driveway & street intersections. A d. Profile of roadway showing existing and finished grades . Roadway profile will show all tangent grade and all vertical curve information . !UA e. Profile will show all catch basins and all drainage lines between catch basins with all invert and top of frame elevations. Drainage lines will be shown and described as to material . /JA f . Where any storm drainage line discharges into an existing brook sufficient profile of this brook will be shown to determine conditions . NA g . Metropolitan District Commission datum shall be used on all sites accessible to these controls . The Town Engineer shall , based on standard engineering practices , determine the accessibility of these controls . Page 4 (Site Plans ) _ h. Profiles shall show all sanitary sewer lines and manholes , including elevations , sizes , lengths , and slopes of pipes . Top of foundation elevations for building shall be shown . _ /V/Q 10. Open Space Site Improvement Plans : For sites which require or include a provision for open spaces , a plan which contains data for site improvement may be required . This map shall be drawn to a scale of 1 inch equals 40 feet . 1NA 11 . Sanitary Report: Where individual sanitary sewage disposal systems are proposed , the final plans shall include a Sanitary Report certified by a Professional Engineer . The report shall demonstrate the feasibility of the proposed individual systems ; the report should deal with the area as a whole , discussing the following points: -414.— a. General nature and development of surrounding area. N*4 b . Topography and natural drainage pattern . _ C . Subsurface conditions as shown by subsurface investigation , including soil absorption characteristics , ground water level conditions , ledge rock , and general nature of soil . _AM d . General description of type of development contemplated . .AJA _ e. Detailed description of proposed sanitary sewage disposal facilities , indicating sizes for various ground conditions , materials to be used , and the general layout pattern to be used , etc . f . Special precautions that may be necessary to provide proper functioning of the proposed disposal systems . g . Map of general area with locations of all tests shown on proposed layout . N h. Flood heights of any nearby streams , brooks, or ri v e r s . i . Test results and engineering evaluation per Section 4 . 13 . 5. All information required above is included in this application at the time of submission . PL E RER P L.S . November , 1987 t0'«N Sfq �v 1540 SULLIVAN AVENUE - SOUTH WINDSOR, CONN. 06074 SOR-CO AREA CODE 203/644-2511 November 13 , 1987 �1 r it" Design Professionals "`{n 491 Buckland Road �ApV Iro 19�� South Windsor , CT . 06074 Attention: Richard P . Martel SoUtt, �N'V ld ommiSsion planning & Zoning Dear Mr . Martel : At a Special Meeting of the Water Pollution Control Authority held on October 27 , 1987 , the Authority voted to approve the installation of the line , as presented by Design Professionals and prepared for, Suburban Printers - Project #87-194 - Map dated 10/19/87 up to man-hole #2 , including the 8 inch stub at the depth requested by the Town . If there is a possibility of some form of Developer ' s Agree- ment for reimbursement after the W. P . C . A . drafts their rules and regulations regarding this , this developer may qualify for reimbursement . This approval is subject to the technical approval of the Town Staf f . Finally , the approval is also subject to the approval letter being affixed to the final set of mylars and filed with the Town . , Very truly yo rs , Joseph Carino , Chairman TOWN SOUTH WINDSOR Water Pollution Control Authority JJC : pm CC : A . Bowen Davies , Deputy Town Engineer Chairperson , Planning & Zoning Marcia Banach , Director of Planning Thomas P . D 'Auria , Building Inspector /tOwN "4 a t� U �- 0-1s � 1540 SULLIVAN AVENUE • SOUTH WINDSOR. CONN. 06074 l�oSOR,coN� AREA CODE 203/644-2511 August 28, 1989 M E M O R A N D U M TO: Marcia A. Banach, Director of Planning FROM: Jerry C. Iazzetta, Town Engineer RE: Suburban Printers We have reviewed the drawings dated August 9, 1989 for the proposed Suburban Printers Addition and have the following comment 1 . The plans do not address the sanitary sewer lateral installation. An existing septic system is utilized by the present building configuration and it is located under the proposed addition. This septic system cannot be removed before the existing building is connected to the Sanitary Sewer. The drawings only show a lateral connection to the new building and a note "existing septic system to be removed" . JCl/jsv PLANNING DEPARTMENT IN-HOUSE REFERRAL FORM TO: Jean Zurbr' Karl Reichle, Mike Gantick, Mel Stead, Fred haw Thomas Hart, Fire Marshall Lanning, Jim Snow FROM: Marcia A. Banach, Director of Planning The Planning & Engineering Departments have received plans for the following project:# p�1- S P 24 P- Zone Acreage o�5 Subdivision Site Plan Residential . No. of Lots/units Commercial Industrial Location: Project Description: S Future Town-owned property involved? Yes No (a)new streets (existing frontage also) (b)new open space/recreation area active passive (c)new detention area Planning Department comments Y Please let me know b �� if you will have . comments on this application so that I can follow up with your department when I do a Planning Department report. RECEIVED PLANNING DEPARTI4ENT AUG 25 1989 IN-HOUSE REFERRAL FORM SO. WINDSOR PLANNING DEPT. TO: Jean Zurbrigen, Karl Reichle, Mike Gantick, Mel Stead, Fre Thomas Hart, Fire Marshall Lanning, Jim Snow FROM: Marcia A. Banach, Director of Planning The Planning & Engineering Departments have received plans for the following project:# P AA,,'_�Q,� P A­4 44, Zone Acreage Subdivision Site Plan, Residential . No. of Lots/units Commercial Industrial Location: Project Description: S Future Town-owned property involved? Yes No , (a)new streets (existing frontage also) (b)new open space/recreation area active passive (c)new detention area Planning Department comments Please let me know by_ �(s��� if you will have comments on this application so that I can follow up with your departme when I o a Planning Department report. ,a tow" 8E.4 CO) r o � u Gary K. Ty1w Chief of Police 4��QSOR.CO�� Police Services SOUTH WINDSOR POLICE DEPARTMENT CONSTRUCTION REQUIREMENTS Project Title: Suburban Printers 89-65P Date: 8 September, 1989 Lel 1. Developer is responsible for the purchase and installation of all street and traffic signs. Any signs on or intersecting with a State Highway must be cleared through the Department of Trans- portation. All signs must be in place before a c.o. is issued. 2. Developer is responsible for the purchase of all street lighting through Connecticut Light and Power. CUP will install all lighting once they have received payment from the developer and the locations of the lights has been reviewed by the Police Department. All lighting must be in place before a c.o. is issued. 3. Developer will submit three (3) 811 x 11 or 81� by 14 maps of the proposed project to the Police Department for the purpose of identifying and locating all signs. Completed maps will be distributed to the developer, Town Planner and the Police Department. Any changes in road design will require new maps. �f 4. Temporary street signs must be in place as soon as possible and maintained throughout the project. 5. Emergency phone numbers for the duration of the construction must be provided to the Police Department on a company letter- head. If the developer occupies or owns the building/s after construction emergency numbers must be provided to the Police Department. 6. All buildings located on property which abutts a public highway must be numbered. Such number/s (address) shall be visible from the street. All numbering shall comply with Town Ordinance 6-800 thru 6-802. Barns, garages and outbuilding which are located on the same premises as a numbered structure are excluded. ,/7 . Require street light installation on CLP #26397 Strong Road. 151 Sand Hill Rood • South Windsor, Connecticut 06074 • (203) 644-2551 -2- CONSTRUCTION SUGGESTIONS Y1 . Keep all shrubbery low around doors and windows so as to allow an unrestricted view. 2 . Locate business name , if applicable, on the building. [� 3 . Backlight business name and address . 4 . Provide lights over all doors . 5 . Provide ample lighting of parking areas . Q 6 . Advise the new owner / purchaser to provide the Police Department with emergency numbers - (Business , Commercial and Industrial property only) . MOMM .00l SIGNATURE Sergeant Thomas C. Hart #103 Traffic Services Unit Approved by: Chief Gary K. Tyler ■ esigo rofessionals, inc, civil engineers • planners • surveyors NOV S011 a'7 Windsor jannrnb Zoning Commiss;v November 14, 1989 Chairman Planning and Zoning Commission Dear Sir/Madam: Due to a scheduling conflict and the inability of our client to be present this evening, we hereby request an extension of 65 days for the application of Suburban Printers (#89-65P) . Thank you very much. Very truly yours, DES GN PROFESSIONALS, INC. By � �re�gorJ. Chiara Director of Planning Services 1170 Ellington Road (Route 30), South Windsor, CT 06074 (203) 291-8755 w M SIN t � r _0 �. 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CONN. 06074 4 � R•co AREA CODE 203/644-2511 6 December 1989 Mr. Peter DeMallie Design Professionals, Inc. 1170 Ellington Road South Windsor, CT 06074 Dear Mr. DeMallie: re: Appl. #89-65P, Suburban Printers Site Plan 388 Strong Road We are pleased to advise that the Planning and Zoning Commission voted on December 5, 1989 to approve the above-referenced application for a site plan of development in accordance with Drawings #1 and 2 of 2 dated 8/9/89 (no revisions) prepared by Design Professionals, Inc. , and Drawing #1 dated 5/19/89 (no revisions) prepared by Concepts Unlimited, and with the following modifications: 1 . Prior to commencement of any site work, a meeting must be held with Town Staff. 2. No building permits will be issued until the final mylars have been filed in the Town Clerk's Office. 3 . An as-built plan is required prior to issuance of a Certificate of Occupancy per Section 4 . 13 .10 of the Zoning Regulations. 4 . A landscape bond in the amount of $2,000 is required and must be submitted prior to filing of mylars. 5 . All plans used in the field by the developer must bear the stamp and authorized signature of the Town of South Windsor. 6 . Iron pins . are to be set at property corners . 7 . Add note that existing trees along the west boundary are to be relocated. 8 . Street light is required by Local Traffic Authority on Pole #26397 . Mr. Pet r DeMallie -2- 6 November 1989 9 . Show foundation plantings. Black and white transparent mylars of Design Professionals' Sheet #1 with the above modifications, together with four blueprint copies of the entire set of plans, must be submitted to this Commission within 30 days to be stamped and signed. The letters of approval of this Commission, as well as the Inland Wetlands Agency/Conservation Commission, must be reproduced on the mylars. After the mylars have been signed by the Commission, they will be returned to you for filing in the Office of the Town Clerk within 90 days. After filing these plans, a copy of the receipt must be submitted to the Planning Department. Very truly yours, PLANNING AND ZONING COMMISSION Louise C. Evans Chairman cc: Inland Wetlands Agency/Conservation Commission M. Banach, Planning Director J. Collins, Chief Building Official J. Iazzetta, Town Engineer F. Shaw, Supt. of Pollution Control E. Belleville, Assessor W. Lanning, Fire Marshal Registrar of Voters Engineer pplicant PZC File tow" T-0�� ap Sau� C � � V s 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CONN. 06074 f��SOR•CO�� AREA CODE 203/644-2511 TO BE PUBLISHED IN THE JOURNAL INQUIRER SATURDAY, DEC. 9, 1989 LEGAL NOTICE TOWN OF SOUTH WINDSOR PLANNING AND ZONING COMMISSION At its Dec. 5, 1989 meeting, the Planning and Zoning Commission voted to take the following action: 1. Approve, with modifications, Appl. #89-103P, Ludwick Szeluga, for subdivision plan modifications (detention basins) , Lawrence Road, A-30 zone. 2. Approve, with modifications, Appl. #89-65P, Sub'drban Printers, for a site plan of development for property at 388 Strong Road, I zone. 3 . Approve, with modifications, Appl. #89-67P, Paul Capuano, for a Zone Change to A-20 for approximately 22 acres of property on the southerly side of Governor's Highway westerly of Beldon Road, RR zone. 4 . Approve Appl. #89-82P, Children's Corner Nursery School, for a Special Exception to Article 4 .1.8.c of the Zoning Regulations to allow operation of a nursery school at property at the easterly side of Sullivan Avenue and westerly side of Ellington Road, RR zone. 5 . Initiate the calling of certain bonds. Dated at South Windsor, Connecticut this 6th day of December, 1989 . PLANNING AND ZONING COMMISSION Louise C. Evans, Chairman Bernard Hart, Secretary 710 O-Ps ?An� s v 1540 SULLIVAN AVENUE - SOUTH WINDSOR. CONN. 06074 4�~�soe•c �� AREA CODE 203/644-2511 oN August 14, 1990 Mr. Ralph Harris Suburban Printers, 388 Strong Road South Windso T 06074 RE: SUBURBAN PRINTERS Dear Mr. Harris: , The South Windsor Water Pollution Control Authority, at their regular meeting of June 50, 19900, approved the above referenced application in accordance with plans prepared by Design Professionals, Inc. titled "Plan/Profile Sheet" dated 10/19/87, revised 5/25/90, and with the following conditions: 1 . Subject to Town Staff technical approval. 2 . That the proposed sanitary sewer be located in the center of the eastbound travel lane. 3 . That this approval letter be affixed to the final set of mylars and filed with the Town of South Windsor. Very truly yours, Ccl#_ ",—/C�& Jqseph Carino, Chairman Town of South Windsor Water Pollution Control Authority cc: Jerry Iazzetta, Town Engineer✓ Louise Evans, Chairman P & Z Marcia Banach, Director of Planning John Collins, Chief Building Inspector John McCahill, Zoning Enforcement Officer