Loading...
HomeMy WebLinkAboutSITE PLAN (WITHDRAWN) (5) o TOWN OF SOUTH WINDSOR , CONNECTICUT • y Y i PLANNING AND ZONING COMMISSION �co APPLICATION FORM 4��oSO2 .Co�� Application No. : 3'9 -K � 1 — 119 - Date Rec ived : , , Yk Action by : /V .S-g�- AUG 30 1989 Receipt No. : South Windsor APPLICANT: m a I nnin & Zoning Commission ADDRESS : —/3 TELEPHONE: 1`} OWNER OF RECORD ON LAND RECORDS : TAB A on Aasoo t aA �g ADDRESS: or COMPLETE LOCATION OF PROPERTY: ��R Q 11 ; yo_�• �ve�u� ZONE: NAME, ADDRESS , & TELEPHONE NUMBER OF PERSON TO WHOM INQUIRIES SHOULD BE DIRECTED: O ocooriL4 TELEPHONE: (,Oqq- q q THIS APPLICATION IS FOR : (Check one of the following) 1 . Zone Change to (Public Hearing required) . 2 . Subdivision . 3. Open Space Subdivision (Public Hearing required) . 4. Resubdivision (Public Hearing required) . S. Special Exception to Article (Public Hearing Required) . 6. Site Plan of Development. 7. Earth Filling [Section 10] and/or Earth Removal [Section 91 (Public Hearing Required) . 8 ! e-� • of Development . 9. Regulation Amendment : Zoning Subdivision _10. Other (explain in detail) : CONSULT PLANNING DEPARTMENT FOR FEE SCHEDULE. THIS APPLICATION MUST BE SIGNED BY THE APPLICANT AND OWNER OF THE PROPERTY AND SUBMITTED IN TRIPLICATE WITH ALL MAPS AND DOCUMENTS REQUIRED ON ATTACHED CHECKLIST. (Z&L'� '9 d '# 04444L ojla� � , Applicant Owner PLANNING AND ZONING COMMISSION APPLICATION , CONT' D. TIME FRAMES AND PROCEDURES FOR SUBMITTING APPLICATIONS/PLANS 1 . All prospective applicants are urged to confer with Town Planning Department and Engineering Department staff prior to submission of any application to the Commission . 2. Plans are officially received only on the fourth Tuesday of each month at the Regular Meeting of the Planning & Zoning Commission (PZC) . 3 . Three ( 3) sets of blueprints are required on the second Tuesday of the month for review by the Town Planning and Engineering Departments . This deadline must be met if you want to ensure that your application is officially received by PZC. These plans must be submitted as complete plans -- which includes application plus all required information contained on checklist . No plans will be accepted at the counter if checklist is incomplete . It is the applicant ' s responsibility to ensure that all information required on the checklist is submitted in one package at the time of submission -- including landscaping plans , architectural elevations, traffic report , etc . Planning Department staff will not accept checklists with blank spaces , or with "by others" in any space . 4. Town staff will notify the applicant with any changes required to make the plans in complete compliance with our Zoning/Subdivision Regulations . 5 . All changes requested must be made and new, complete blueprints must be submitted . At this time six sets of plans must be submitted . If a Public Hearing is required ( or optional but likely) then seven sets are required . 6. Planning Department/Engineering Department staff will review plans only once -- if the resubmissions are not complete/correct , the Town Planner ' s report will reflect that revisions were not made as requested . CHECKLIST RUT REQUIRED INFORMATION SITE PLANS AUG 30 1986 This checklist must be signed by plan preparer (p 'South Windsor that all required information is provided . Itemsp�+gr`e re uuired for all applications ; items 8-11 required where appropriate . Check mark for each item supplies . 1 . On each sheet for 1 p ans or maps , title block with the following information : a. Name add ress and telephone of applicant . b . Name , address and telephone number of Land Surveyor or Professional Engineer . C . Name of Development . d . Date when drawings were made . 2 . Key Map : An overall map drawn to a scale of 1 inch equals 200 feet , which can be used as an overlay on Metropolitan District Maps . This map will show the overall design of the Development and surrounding property within 500 feet . a Data 1 'a a block which gives needed zoning information such as percentage of lot coverage , acreage of tract , number of apartment units , parking Jrequirements , etc . b . Layout of buildings c . Layout of streets and parking , d . Lines indicating proposed drainage system with direction arrows . e . Lines indicating sanitary sewer system with direction arrows . f . Names of surrounding property owners . N +� g . Proposed open spaces and recreation .areas . ' h. Driveway cuts on surrounding properties . 3. Architectural Elevations : Plans of the proposed buildings drawn to a scale of 1/8" = 1 ' - 0" showing the elevations of all sides of the proposed buildings in sufficient detail to show architectural styling . Architect ' s seal on elevations for buildings in excess of 5000 square feet ( per CGS Chapter 390) . Page 2 (Site Plans ) 4 . Plot Plan : A layout map of the proposed site drawn to a scale of 1 inch equals 40 feet on either of the following size sheets : ( 1 ) 24" X 36" with a 3/4" ruled margin ; ( 2) 18" X 24" with a 1/2" ruled margin , containing the following data : a. Distance and bearings of all boundary lines and acreage of site . Iron pins required at all property angle points and shown on map. N 4 b . Proposed streets and street lines with center line stations , curve data , and parking spaces . V c . Buildingline in s accordance with zoning / regulations . J d . Proposed buildings and other structures , including signs , outside- lighting , and dumpsters (on concrete pad and screened) N e. Easements , noting grantors , grantees , and purpose . ✓ f . Names of abutting property owners . N d g . Monuments will be indicated at corners and angles of all streets and at all points of curvature and tangency . In areas accessible to Metropolitan District Commission points , or other coordinated points , the monumented points within proposed site shall be coordinated . These coordinates shall appear in tabular form on the plot plan . The accessibility of these MDC points shall be determined by the Town Engineer . N/A. h . All open space or other common or public land uses shall be indicated . i . A-2 certification ; P . E. /L. S . Seal . 5 . Topographic Ma : A p map drawn to a scale of 1 inch to 40 feet . on sheets not exceeding 24 inches by 36 inches , including ruled margins shall in addition to the requirements of the plot plans show the following : a. All existing and proposed buitdi ngs . b . Curb lines and pavement width , sidewalks . C . Existing and proposed sanitary sewers . d . Existing and proposed water and Y gas main systems . / e. Present wooded area indicated by foliage lines . Any individual trees to be saved should be shown . L'doe ( J 1 u.,e r' L a n s f . Existing and proposed contours shall be shown in not less than two-foot intervals , but in cases of relatively level land , the contours shall be one-foot intervals and spot elevations . / g . Regulated wetlands and 100-year floodplain or note that none are present . h. Proposed storm drainage system, g y showing all catch basins , endwalls , manholes , lengths and sizes of pipes . (Minimum distance between catch basins shall be 300 feet and minimum size of storm drain lines shall be 15 inches . ) N*s i . Connections of all springs into proposed storm drainage system as needed . j . Location and indications of existing brook channels , and 100-year flood limits . v/ k A-2 Certification ; P . E. /L. S , Seal . 6 . Landscaping plan . y 7 . Drainage calculations - Zero Runoff Increase per attached guidelines . . -_ 8 . Traffic report . JV 4 9 . Plans and Profiles : A plan and profile of the proposed streets drawn on plan/profile paper of scales 1 inch to 40 feet horizontally , and 1 inch to 4 feet vertically on sheets not exceeding 24 inches by 36 inches , including ruled margins and containing the following : a. . Layout of streets in sections coordinated by stations with the profile . b . Street plan showing roadways and drainage . C . Sight line at driveway & street intersections . d . Profile of roadway showing existing and finished grades . Roadway profile will show all tangent grade and all vertical curve information . e . Profile will show all catch basins and all drainage lines between catch basins with all invert and top of frame elevations . Drainage lines will be shown and described as to material . f . Where any storm drainage line discharges into an existing brook sufficient profile of this brook will be shown to determine conditions . g . Metropolitan District Commission datum shall be used on all sites accessible to these controls . The Town Engineer shall , based on standard engineering practices , determine the accessibility of these controls . Page 4 (Sine Pians ) h. Profiles shall show all sanitary sewer lines and manholes , including elevations , sizes , lengths , and slopes of pipes . Top of foundation .elevations for building shall be shown . N_ 10. Open Space Site Improvement Plans : For sites which require or include a provision for open spaces , a plan which contains data for site improvement may be required . This map shall be drawn to a scale of 1 inch equals 40 feet . - NA_ 11 . Sanitary Report: Where individual sanitary sewage disposal systems are proposed , the final plans shall include a Sanitary Report certified by a Professional Engineer . The report shall demonstrate the feasibility of the proposed individual systems ; the report should deal with the area as a whole , discussing the following points : a. General nature and development of surrounding area . b . Topography and natural drainage pattern . C . Subsurface conditions as shown by subsurface investigation , including soil absorption characteristics , ground water level conditions , ledge rock , and general nature of soil . d . General description of type of development contemplated . e . Detailed description of proposed sanitary sewage disposal facilities , indicating sizes for various ground conditions , materials to be used , and the general layout pattern to be used , etc . f . Special precautions that may be necessary to provide proper functioning of the proposed disposal systems'. g . Map of general area with locations of all tests shown on proposed layout . h. Flood heights of any nearby streams , brooks , or rivers . i . Test results and engineering evaluation per Section 4 . 13 . 5 . All information required above is included in this application at the time of submission . AIM7 . E DATE ;November ,, - , ' 87 .......... AUG .�o 1988 �ndsor Commission {; NO. is �` SS ON Al t xrs}"�n t 'CA Y)a � C -5) (6.1� IIJ-1 C�s C, ... O. P. Are-CA ecJ- n Y--.ck f3 0. 7 Q 077-- (�3-2) C0- 7)CG.IJ JSS. �s.a f , ' s tEnv Ir11�,� 7-To zs va u►v1-e., a 3,p /5 /oo 1 `i) 7 L4 $ i - ZZ 8 '4 .o /S, qoo mCot Iv,nvwt � ��p� - o�- �� rofIt�+ 1 Gt z .S9Z 1q -7y8 X O. � qq! 'Ir,),�,pll{{ ,�1•� k a ay�ti S�`7g.���'�'J ti;,ti; ,a„ g f}A,ter { r} 1�.1.•�, �,,� dDi� f4� tttS� `;�;1f;'��!;S�`� f!�fj�+, •(y. ,ri.`�M� I"P�6' S _ , ��.F�y��a.."n;lY. „a;•'T,`f,,.�:•�,;.3':i�.J{fC1�:'Kst, '��!i a' ��;�'nl�p}i:�;;i`,r (Y) Mpi Q�rv�. log fir', ��� 1 }'Y c w i id �S G11 •rr Y�' 3 Z Z) (. 79) (0, 87,) 3 . ? Cis 5 c e\j e,opm eY)V iS Cis Aill i �• v����;�1�"'�'a'`�y,',f �-,^`���#f� ..V� � ,._ L1 ", '�y ,5'�.�,t� `�i .�� V r� T '' • o �'r"4���`,:tit ol cv m�n�` .i September 30, 1988 M E M O R A N D U M TO: Marcia A. Banach, Director of Planning FROM: Michael J. Gantick, Director of Public Works RE: Engineering Review Sheridan Industrial Park Please find attached the SEA review of the subject application. Additionally, the following comments are noteworthy: 1. Hydraulics of the swale has not been demonstrated. Also, how will it be built (appears to encroach on abutting property) , right to drain from abutter needed, profile of swale needed, outlet structure elevation is in question. High groundwater in area will present problems. 2. Protection of vehicles along swale needed. 3. Spot elevations/contours needed along adjoining properties. 4 . Use of site relative to turning radius - site circulation is questionable. 5 . Capacity of existing storm system in Sullivan Avenue should be evaluated relative to this application. 6 . Track pad is mislabeled as "truck" pad. 7 . DOT construction permit needed. Would not recommend two street cuts/driveways for site. 8 . Reverse filter design needed for riprap. 9 . Concrete walk detail not correct. Should be 5 inches of concrete and compacted ravel base. ENGINEERING REVIEW SHERIDAN INDUSTRIAL PARK 10 . It appears from the SCS soil survey that the soils in the area of the proposed project are not suitable for road fill and there is a seasonably high groundwater table at or near the surface. The proposed driveway parking area should consider these soil conditions. Present base proposal appears to be insufficient. It is recommended that no action be taken on this application by the Commission until such time as the noted items have been resolved and this Department has reviewed same. Should you have any questions please contact me. MJG/jsv cc: Project File �.M SEA Consultants Inc. September. 26, 1988 -` Engineers/Architects Principals Mr. Michael J. Gantick, P.E. Arnold B.Goldstein,P.E. Director of Public Works Frederick G.Aufiero,P.E. Robert M Brandon,A.I A. Town of South Windsor Stephen H.Geribo,P.E. 1540 Sullivan Avenue David T.Goodemote,RE South Windsor CT 06074 Bruce E.Soule,P.E. Kenneth M.Stewart,RE Anthony J.Zuena,PE. Re: Sheridan Industrial Park y Associates Job No. 88126.43 Steven L.Bernstein,PE. Task Order No. 43 Paul F.Gabriel,P.E. Mark Gould,P.E. Joseph A.Murphy,PE. Dear Mr. Gantick: Michael S.Schultz,PE. Paul C.Showstead,P.E. As requested, S E A Consultants Inc. has reviewed the Arthur A.Spruch,PE. following for the above referenced project: Paul C Ross,P.E. Sheet No. Title Prepared By Date 1 of 5 Key Map Luzzi 3/88 2 of 5 Plot & Conservation it Plan 3 of 5 Utility & Topographic Plan 4 of 5 Architectural Elevations 5 of 5 Landscape Plans & Details --- Storm Drainage Calcula- tions This information was reviewed for compliance with the Town of South Windsor Subdivision and Zoning Regulations dated July 24, 1972 and standard engineering practice. We note the .following: Section 4 . 13 .2 . 1 KEY MAP D. Arrows indicating proposed drainage should be labeled. E. Lines indicating sanitary sewer systems should be 850 Silas Deane Highway designated on the map. Wethersfield,CT 06109-3412 (203)721-7993 Section 4 . 13 .24 TOPOGRAPHIC MAP 485 Massachusetts Avenue Cambridge,MA02139-4018 C. The flow line elevation for the sanitary lateral at the (617)497-7800 existing 21-inch sanitary sewer on Sullivan Avenue should 1537 Main Street be indicated. Springfield,MA 01103-1420 (413)731-9662 Citicorp Park West 100 Foden Road South Portland,ME 04106-2319 (207)775-2281 r Lima SEA C nsultants Inc. Mr. Michael J. Gantick, P.E. Engineers/Architects September 26, 1988 Page Two Section 4. 13 .2 .2 ARCHITECTURAL ELEVATIONS Architectural plans and elevations should be drawn to a scale of 1/8"=1'-0" and provide sufficient detail of exterior building materials. Section 4 . 13 . 6 CONSERVATION PLAN Soil classifications and boundaries should be delineated on the plan. Section 8 OFF STREET PARKING A parking waiver of twenty (20) spaces has been requested and 4 �- is indicated in the data block. GENERAL COMMENTS Y 1. Two (2) handicap parking spaces have been shown on the Plot Plan. However, three (3) spaces are required in accordance with the Town of South Windsor's regulations. 2 . Handicap parking spaces should be labeled on the Plot Plan. 3 . The detention basin has been analyzed for a 10-year storm. However, South Windsor's regulations require zero net increases for post-development conditions during the 21 25, 50, and 100-year storm frequencies. 4 . Proposed contour elevation 84 at the southwest corner of the property has been drawn incorrectly. If you have any questions, please do not hesitate to call me. Very truly yours, S E A Consultants Inc. d hn T. Holland JTH:ap C T_0 a-P S-0 ?O&U&1at V 1540 SULLIVAN AVENUE • SOUTH WINDSOR. CONN. 06074 �'►'osOR-CO AREA CODE 203/644-2511 October 8, 1988 4' Mr. Robert Sheridan 25 Oakland Road South Windsor, CT 06074 Re: Application #88-85, Sheridan Industrial Park Site Plan Dear Mr. Sheridan: Attached is a copy of comments from the Planning and Engineering Departments regarding the above-referenced application. Please make the necessary revisions to the plans and submit 6 complete sets (including architectural elevations, landscaping plans, etc. ) to the Planning Department. If you have any questions regarding the comments or the procedure, please contact me. Very truly yours, Marcia A. Banach Director of Planning cc: Town Engineer v SHERIDAN INDUSTRIAL PARK - PLANNING DEPT. REVIEW COMMENTS Key Map - show surrounding driveway cuts Zoning Data Table - parking seems low for number of units Plot Plan - Where is required buffer along RR property (south boundary) . Must be in accordance with Section 5.4 of zoning regulations Topographic Plan - show regulated wetlands - foliage line required, or note that site is not wooded Landscape Plan - Plantings along west boundary appear to be in the riprap ditch - small plantings in all islands adjacent to buildings might be appropriate be sure buffer plantings conform to Section 5.4 if-V NOV I9 CREATIVE DEVELOPMENT DEVELAPMENT GROUP,INC., 25 Oakland Road/South Wincfn% �bQkQhsi 17 ; November 21 , 1988 Planning & Zoning Commission Town of South Windsor, CT �! Re: 589 Sullivan We wish to request a sixty-five day extension. Sincerely, e% • d' Dennis Moy Than NER December 27, 1988 Town of South Windsor Town Planning Commission 1540 Sullivan Avenue South Windsor, CT 06074 ATTN: Marcia Banach Director of Planning RE: Sheridan Industrial Park, Sullivan Avenue, South Windsor Dear Ms. Banach: Upon advice of our engineer, James Luzzi, we hereby request that our application in the above-captioned to the Town Planning Commission be withdrawn. Mr. Luzzi will resubmit at a later date. Very truly yours, SHERIDAN PARK ASSOCIATES By David S. St6ner Partner DSS:jjm file 65 Louis Street Newington,CT 06111 (203)666-2888