Loading...
HomeMy WebLinkAboutDrain Layers Permit Rosemary Lane (5) MEMORANDUM December 6, 1977 To: Allan Young Re: T.V. viewing and air testing two (2) sections of Rosemary Lane On Monday, December 5, air testing, T.V. viewing and sealing was conducted on Rosemary Lane. Present during the operations were: Mr. Bill Dobbins, D.E.P. Mr. Dave Tomey, State Health Dept. Mr. Daniel Savino, State Health Dept. The work was done by the Wethersfield Sweeping Service. Results were as follows: From M.H. Sta. 5 + 0 to (8 + 35 = 2 + 95) (E. to W. ) 134' from M.H. - water bubbling in at bottom of pipe joint this was sealed. 284' from M.H. - Lateral to "Parcel G" leaks excessively - has to be repaired. 285'. from M.H. - broken pipe - water pouring in - has to be repaired. From M.H. 5 + 40 to 2 + 95 = 8 + 35 (W. to E. ) 192' from M.H. (Bloom lateral) leaking more now than last July has to be repaired. Also, broken piece of pipe at 3 o'clock opposite lateral. These findings are of a nature that have to be taken care of immediately. See enclosed approximate costs. One. other note, the manhold cover was removed on Rosemary at .Sta. 5 + 0 to 2 + 0 (end) and initially, very little running water was observed. However, later during operations, water build-up moved plug at M.H. Sta.. 5 + 0 and water came to top of brick invert work. No time was taken today to determine the cause, but this should be looked into. There was only one house in this area that could have introduced water, so it seems that conditions may be more involved. The State also wants the easement Section (442' ) to be T.V. , but with no laterals here, an air to would be fficient. Frank/ C. Messenger / g G FCI,,I/ml cc: B. Page Enclosure I i I 1 E I i I f if i i i j a j f i �� i i i i i o �e