Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Drain Layers Permit 1451 John Fitch Boul
TOWN OF SOUTH WI N DSOR DEPARTMENT OF PUBLIC WORKS BUREAU OF POLLUTION CONTROL DRAIN LAYER'S PERMIT o 6 4 O 1 A: 199� Pursuant to written application, permission is hereby granted to the Licensed Drain Layer named herein to perform it worJ indicated below at /L/ s/ ,-)k at premises owned by whose address is and to Lay House Drain, Repair House Drain, Lay Main, Other , for occupancy or use, with Family Units, with acres. Type of Sewage to be connected under this permit: SANITARY SEWAGE (y;INDUSTRIAL WASTES ( ), OR ( ) Connection will be made with Show sketch of proposed work or furnish two (2) copies of separate draw' gs. f� la, s �v �m, P � CP SPECIAL CONDITIONS Desired Starting Date Estimated Time for Completion Permit to be issued to the holder of Drain Layer's License No. Permit will expire thirty (30) days after date of issuance. The undersigned Drain Layer hereby agrees to all the terms and conditions set forth in the permit and the reverse side thereof. Applicant has received Town Permit No. and/or CHD Permit No. Signed Licensed Drain Layer The above named Drain Layer has a valid license issued by the /�tate of Connecticut and has filed a satisfactory bond and insurance polio in 1the name o .6he Town of South Windsor: I ngfne t' g Department Date ti Connection Charge Paid " '� Permit Fee:-'Paid $ , C� -~'\\ELC` Check lqumber D Als 513J 1A CC Issued by Tax Office INSPECTION Date work started Date completed Sufficient notification received: Yes No Special Conditions APPROVED Inspector Date 520/5 WGL= 20 2 HP Grinder Pump For Residential, Commercial, Industrial and Municipal Wastewater Applications The Myers versatile 2 horsepower WGL-20 submersible centrifugal grinder pumps wastewater at capacities up to 40 gallons e and heads Up to 105 feet. It features Myers'patented cutter mechanism and recessed impeller design to effectively mascerate typical sewage solids into a fine slurry. The slurry or wastewater can then be pumped to a treatment plant,lagoon,or gravity man- hole through a discharge g g pipe as small as 1%a" in diameter. The Myers WGL-20 can be installed with a variety of package systems.A simplex or duplex,quick-disconnect fiberglass rail system can be used for depths up to 16 feet.In areas with mild climates and shallow frost lines,the grinder pump can be mounted on legs for Union system installation.A suspended type package system is also available for indoor applications. The WGL-20 grinder pump is not recommended for heavy duty applications. Instead,use a Myers 3,5 or 7-1/2 horsepower grinder pump. RE,Myers manufactures a complete line of sump,sewage,effluent,grinder and non-clog submersible wastewater pumps. Myers also manufacturers a companion line of control panels,controls,and fiberglass basins. For additional information,please contact your local Myers Representative or the Ashland, Ohio office. Myers WHEREINNOVATIONMEETS TRADITION MYIWS° .. WGL= 20 P GrinderPump For - •- i•l, Commercial, �I1111Industrial • • Municipal Wastewater Applications 1. STATOR.Rating is 2HP 3450 RPM 60Hz available in 200&230 volt single phase and 230&460 volt three 9 phase.Stator is pressed in for perfect alignment and best 20 20 heat transfer.Oil conducts heat and lubricates bearings r� and seal. 2. HEAT SENSOR.Protects motor from burnout due / to excessive -. from any overload condition. _ \�\ -_MEN MIRA MEMO \ \� ��I • - -- • •- -• • • •� • V?AF �► 1101 • • • • • • n _ •.: •• • • �- - • - -• Z MR :��=�-• 'm■ ■a■vu.mu■i..u■.............. ................. ■ ■muuuuruuuuuuuuuue■uun ��/ � i ■ ■nnuoomuuunnuuuum Imo/ ■i�iae. ■9.9■■■■■■.9C99■.....9�...99.... I� uu.�uun. uuu..■..............■uo 00000 i \ EE.. .■mmom o.0 ME MO uuouuouu.yuuuouuu■.uu..uu .m ■.u.■...■....►_�u■■.■uuu■u..S.. ME ■m..■u.e■u�.�.mm.u........■.. ME i■■.__ ■■■■uumM.u■uouu000uv L S uuuM._ ■...■r.umcv.uuuuuuuu 'i...........4 :�iiiiiiiiiii uuuuuuuu.au. uOEEauuuuuuu uuunuuuuu.am.■000un.�o■oouuo ■ _ ■nu.■■.u■uu;vunnncuvnn.nME ■ ■m■.■.m■■■..■.M.■■..■■.■.�u■u.■■■■■ 1 ■■SEEM-_ ■■..■.■.■EECV■mOO•`■mSEEEE■■ iie:i:eii:G.._ MXMMMMM u■.u■■..um.._ ouuuuum►vuEE.vuEE. .•.ouuououo..uuuovo.]u■■■\7.■.O SEE■■SEE■■..■u■SEEM au nnn ON"'u.■.vm..■ u.Su■■m■u■■■uOEE►..n...■rmEE■.e MEN on . . , ■■ ■.0..=■m �.....■■■m.\■.m■■EEEE �■ .m..mO .m.m .■:►:•m■■■■■■.�\■■t■■SEE I1�11 uuuunouEE..uuum►unnn .uuuuu._ nuouumucu■■.■.Im.■■■ uuuu■u■■M. u■uo■oEEu■rvueur.uu '.■■■M.■uEE■..■■.:■�oouu.nucvm.■u.■m. u■uu■■■m■.■■um._.ououvuum►vouu■■ ■ u■mmmm■■o■uM.uuu■u.o■►vn.u.e / ■ uu..uoni:uuu■enu.►u.uu■ SEE■o..■..►......uu..■ru u■u �' uounu.. . uumuuv.u.eu■nuuto ..■■■..mou.- ouu.u..•uu.uuuuuu ■ma__� nuouu ...►. ■ouuoocuoouu.u.o ■.EE■r..m...EE■..n I u1t■■. .■■SEE V i■■.mEE■OO uu.u■..............vuu.■eo rre■uu a■u � .■■■.o■e.■.uu■EEEE e■.vo.ro.. ���. 'o■e.o.onoou.000..uuo■■EEneuuuu■ .. umunooEEsuoum 1■uo■n■mmMeum ■�—�� • �� •1 1 1 1 e oll 0 ;. M1 ` - 520/7-1 M"M 2HP Residential Grinder Pump Rail System Package Structural Polypropylene Cover 41 I% Guide Rails GRADE.. Control Panel and Visual High Water Alarm Structural \ Lifting Chain Plastic Junction Box PVC Ball Type Shut Off Valve and Handle I - i PVC Discharge Pipe�z i High Water Alarm Mercury Level Control Inlet Hub , (Field Mounted) ON and OFF r I \ Mercury Level Controls 2 HP Grinder Pumplip b Diameter 60"Fiberglass / Fiberglass Basin • o B: Concrete .Q ^P • 1 • 520/7-2 CA M"M _ ------- ------ 2HP Residential Grinder Pump Rail System Package y cfl Basin Assembly v Basin Assembly Top View & Side View 54 45 1 1/4 DISCHARGE FLANGE 0 TOP VIEW ° ° ° ° yy1 1/4 BALL VALVE I 1 'J 5 4 0 O 0 0 BASIN COV)CORROSIONRESISTANT 0 ° 1 1/4 SUPPORT FLANGE STRUCTURENE PUMP GUIDE AND RAIL SUPPORT YOKE LIFTING PLATE JUNCTION BOX FLCW MTG. BRACKET SIDE VIEW 11/4 BALL VALVE 48"MAX. 1 1/4 PVC DISCHARGE PIPE 1GUIDE RAILS LIFTING CHAIN F1 1 INLET ELEV. L.,� HIGH WATER ALARM PUMP "ON" 24'DIA. FIBERGLASS j/ BASIN PUMP "OFF" BASIN DEPTH JL 2 520/7-3 M"M 2HP Residential Grinder Pump Rail System Package Basin Assembly Technical Specifications Ball Shut Off Valve E The manufacturer shall furnish and deliver Efully assembled grinder pump stations to the contractor or owner. Simplex units, containing I4 NPTone grinder pump and all necessary parts and o equipment, shall be installed in fiberglass rein- o 0 forced polyester tanks for outside installation. All equipment shall be factory installed, except PVC BALL AGAINST `-l4 PVC TRUE VALVE ION for externally mounted control panel, gravity TEFLON SEATS CORROSION RESISTANT sewer inlet hubs and pump assembly, which are to be installed in the field. 4. Rail Assembly Each pre-assembled simplex station shall include the basin, basin cover, grinder pump and All guides, brackets and hold-downs will be of non-sparking, corrosion resistant structural motor, quick disconnect rail system, check valve, junction box, start-stop level controls, motor plastic. high temperature shutoff, motor seal leak alarm, A lift-out guide rail assembly shall permit easy removal and installation of the pump and lower high water alarm, all internal wiring terminating check valve without the necessity of personnel into the junction box, shutoff valve and Schedule entering the basin. Structural guide brackets 80 PVC discharge piping. In addition, an external alarm and pump control panel is to be provided with guide yokes of sufficient bearing strength -- for each unit. to prevent binding shall bolt to the pump. The yokes shall mate over guide rails of a minimum of 1 inch fiberglass pipe running between an 1. Basin upper rail support and the discharge case. A lower discharge nozzle, downstream from the The basin shall be 24" diameter with depth as check valve, shall be guided into a chamfered shown on the plans. The basin shall be molded cavity in the discharge case. A shoulder on the of fiberglass reinforced polyester resin manufac- nozzle shall bottom on the discharge case when tured by the lay-up and spray technique to assure the pump is properly located and shims shall not that the interior surface is smooth and resin rich. be required to insure alignment for a leak tight The basin shall have a minimum wall thickness seal. Dual "O" rings shall effect a hydraulic seal of % inch. A steel anti-flotation plate shall be around the nozzle when it is in its operating molded into the bottom of the basin. position. A brace, easily removable from the top of the basin, shall be provided to lock the parts together, preventing line surges from breaking 2. Basin Cover the seal and allowing leakage. The discharge The cover shall be of %" polypropylene. The case shall have a discharge opening with piping cover shall be bolted to the basin with stainless to a coupling through the basin wall. steel cap screws. Cadmium plated nuts for the The discharge case shall be securely bolted to screws shall be embedded in the fiberglass to the basin floor and arranged in such a way that prevent turning and for corrosion resistance. slight deflection caused by the discharge pipe will not cause the quick-connect pump flange to leak. 3. Shutoff Valve A lifting chain shall be securely fastened to the top of the pump and to the top of the basin A PVC true union ball type shutoff valve with to facilitate removal of the pump. The chain teflon seats shall be furnished and installed in shall be minimum of welded link type, or of the discharge piping, as shown on the plans. If adequate strength, required to effectively sup- the discharge depth is more than 2 feet from the port the weight of the pump assembly while surface, a handle extension shall be supplied. removing and installing. 3 A 520/7-4 M"M 2HP Residential Grinder Pump Rail System Package Basin Assembly Technical Specifications 5. Piping �=�% Schedule 80 PVC discharge piping shall connect to the stationary discharge assembly and terminate at a 1 V discharge u ssem y flange mounted on the basin at the height shown GHAING on the drawing. HOLD"N BRACKET Cast Iron Check Valve F.NOT RAIL SUPPORT - -OViDE RAILS DISCHARGE i SST SCREWS .__. HOLDOM II BRACKET D RUBBER FLAPPER CAST IRON BODY \ - EPDXY COATED C ( _ (II GUIDE PLATE ---.-I I/4"PT L A I I/4 NPT L CNECK VALVE ' 6. Check Valve V A heavy duty spring loaded.all rubber flapper OUKK CONNECT iLANGE ORIHG type check valve with cast iron body shall be an SEAL integral part of the discharge seal assembly and RAISED POSITION shall lift out with the pump assembly. The valve design shall be such to allow for operation when A negative heads, of up to 5 feet, are encountered. _ The valve shall be designed to operate at all pressures in the sewer system created by the grinder pumps. A flat set stainless steel spring, integrally molded into the Buna N rubber flapper, shall be BASIN WALL furnished in order to prevent collection of debris in the check valve. All fasteners shall be stainless 5"HOLE REQ'D steel. SEALING FLANGE (SELF•SEAL ING) /• 7. Inlet Flange A basin inlet flange for 4" SCH 40 plastic pipe shall be included, but not mounted on the basin. The flange to be mounted in the field at inlet height required by the installation, or as shown V INLET PIPE on the drawing. 2- (SCH.4O) Inlet Sealing Flange 4 520/7-5 M"M° 2HP Residential Grinder Pump Rail System Package Basin Assembly Technical Specifications 8. Anti-Siphon Valve The basin assembly shall be arranged for quick and easy acceptance of an anti siphon valve in the field when required. A riser pipe shall extend from the pump Anti Siphon Valve discharge between the check valve and the gate valve to within two feet of the surface of the basin. The riser shall be capped. An anti-siphon valve kit shall be supplied to easily assemble to the riser pipe. The valve assembly shall include all materials required to complete the assembly. The anti-siphon valve shall mount horizontally, shall be made of PVC and will not interfere with pump removal or installation. 5 1 M"M ■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■ 8:�9E68�E8B�69m��EEBE::� Residential Gri • ' Pump Rail System Package iiiiiiiiiiii■iiiiiiiiiii ■■■■r�1��r�r���rr11�����r Grinder Pump Grinder • CONSTRUCTION FEATURES ��■■n ••• • • • • • • • M . %��/ice��i�iiiii%j=_� • nea 3amwt�-6,i]IVJWti ni;L�.w iJ -� c.-wtf ..n..:a.3 nrver7a®mm7.o®■vnnrc®rv7®MmaElaY®mvotln.>; \!IB rrr®®rrm®®®BrrRm®M0d®®p®0®®OB®©eef®e®B®CfG} ■� �■ � vrav®® mnc]�ve7El®v®ao®�.aiacetmr]GYc7utevr,amnr.. 1 "ay.n®®v®. mvuuvreE,�W®vWr�von�loF�F3c�uu®ums�uEe �'� `\I � ow- / noo®avcGEs®® mnEi€FeaEuar�nveaoF�s®aar�m�c9vtaavu tl YFaRn&7�i1€] 21OB -{7.d[]F C m 7F'm GFJ FI3FiF71l Cl Pi CiL9mm� ®7unamW4)F]3:-,EIS'Eplw ®Wt9Ci1S(lllE't3f.5La633PIF34l[lGti.S°JnLE37GfL no Yr.1,11, Bmt3 onkl g.klgo SIC gug2om4omllmmmai]E omnt A ® rran®®civtlnorl. a®mvvuamnYmavrravmmvrvra �u\\\ ; ■ � `"\` /�'� _ �Fl®v�ec 3G �me ®:EatiOut�oc.c3m�7nuc]9�E]EgntJE� ►► \\\\\� ►�\\\\\\�/ �/ emo 6f lrlm® wtl® v®GES1� ! allay alaL -/-/- // / Bne®av® J1Ratd�l V3(3 k➢m® ®Y®m�G][il{EVG 7WuHM w Nu r; :1 P3PItlF3 Li®n©F3®® ®[IF3 Pl Ele7F3 Pltltlm\ ounn.fmY rums m 4"flau � �i iiiiiiJl���iiiiiiii� ®av®muuvGra€36a7® vve.lvrlvm©mF3o ®nE'.elrElnE7murJvalv�. a m WL9:UUMU4`t3LIMMU Gf3 ® RCd& LU Ely ©FitluM UC N4DF uE: ®m mFl kt®....Cl©GWE].. F"6i]�G fS '] '1f'E9 ®bi]❑].] l.liak Ct fpWm&1(a F,74�69©f13L1W9€on ®NbmP3@tfWtl� 763E GZiP®l3Li'EV 6f3®t3an Non UEi1,1'mC3 Fi❑vas®mEs7W t7L7]F3 GClGGt`E6'bm�-'3m7i GL1E3GGPIPJGE7e: E3 -e_ 3Lf[]u"L'.7aP.®Eiu..Lv:is®.©mE1 F7v..;ui - mmY®.®EiF9rs- ,p61❑©F767®E3 E:70?■m91E761ma.eO mnFimm[iL ay..........." vvYvvtlnmmmr;®oavmtlswvvvm® ruvuvvrvvvu►- ■uYmvYvvvvv■wsrvosmrvvvuavu •'erurursurrrur.�uuruurrswrorcuury er®rrr®®p@I r.m®mGrrr\_rrr rmr tlorrr��rr.rr.\rrr7rl C `�\\�.�•\ �` -/ mm7rar..®nnY19Y]9®mmn0m.-r®®®®mmmm®ElkF3®®l rmmF3G � •r r®.®tiBt,mnilGmmm Ymao..®mnnmW®Bn®lrm HIM'all • ■rmY.r■rurrnmerrr�®rrenumrso.®re•/ momum®v®.vo.mmmtivv®r®�7Yvravvr►aruv®;�rz 1-� I/ i�i . `_�� ver®®._ v.n.m6acsGdaucs®rs.ero©P7nvv.•rYvt1F;51:: �■ rrr■rr■®.- ue]mvmveYvv®mr?rm®®vvv.�Y®.mis. nisiiiiss®ioGr. .®woclYa®�rooa®via�aosmi�i°enmm" 1®tlrrtlrBrr Yrtl®OG®w�®rraY®tl®rr!]®pl.®voomsINN. .is F,f®tlG1©mElt]t3 Cf 3lA5t]fdB€ISfmA�aL]mt37 L)i]Cd E]33SG'E3[iidEi[7 FJB CiF31:r1_: lF L.[3 Ltd ©Ap© n®C37'.(3 ..1 9E F �1019■mE.G,J. 1 m -�Fln L3r JLJE]CA l3 L�IG VLi 6 !� F,1 .I F.VY\'Yf�Y mC.].A.. mt3 311LEI F'u E(A V61[J e3 L9 (Jp9.l❑m\.•6q{E: vaf3Fli7© ,;, f FittL EI® tl4J C 1 c]fJt�il(5 BEIGI❑EI �3€8l.FJ l34lb ®sFlL .... a4!!n€1G71.9FM, El L7 L kCl EIGO FIE t,11 It3 L[IEf1 GC-i,; aahlDb-,w', Fu 1...,ilm®_atl(3[a E.il E]:3:7:217gs 7u LUFv t:t...:fi�.Y BmE-i&.:' id auLl1=4111A0 Liu P]U L]fl•lD a us "I L'u L i mf3;d.1 Clbia F'[]GP L41-F]E7 E]0.®C7 [Mll u'Bi]m F] Pe L167::.�!L]130 Pi:e+; WBmnf967K Gf9GIFJOnc3nmv0\\®mEf uf)N13uC1©9uui3L']P]m'dp G€Imo<. 0>➢maC9E1GE Fl P3 mFl EleimtlGlm Wnm® e]e3!inq BPC]Ei®'F3 E7 nnl'Jtev DEA.71%i, rrrrrmrr®u®3�nortivmmtlre�rmmrrarrr•rrro.rr•arrFai] ®®neeamaOamaF]maF�rl�tt3uwo®®®maaaev©Y®maevtlmY vf;a.e]r i.©nmL]43ilF%Pl tl Cl launuf'u'l�l fl E:mLIWYI 7nG' OC'.RY YI9E73(Fla®•YE9GnC' F3 E3E§7Gmtl6f Limf:4:[3 t3F^.Wlim i]F]El L`m.IGt7 GFi GFII�p E!:!!"!P:S:E1(;p tl(JI)G:_ 6tW tlf9r i394]Pd E3 t]Pl b'6i7 mu C9t:7[(mmn IE567Cki 69]ILiO®®G3LiiiE]F7p tlL.'z3W[: u[n......ki F30t7Wnat7:3!7tl(067n'Im;l ml3a®p:Y Y7vmnCItlY.Flf3 EI E3 1 i]�-'r[Ii7iJ t•,.C7 iV9f3:'=`]®L t.;49 C3n�I] .11PPR[:t 1 520/7-7 M"M 2HP Residential Grinder Pump Rail System Package Grinder Pump Technical Specifications 1. Operating Conditions The motor shall have two bearings to support Each grinder pump shall be of the centrifugal the rotor; an upper ball bearing to accommodate design and be capable of delivering a minim ... thrust loads and a lower ball bearingto take of 25 GPM at 84 feet head. The shutoff head radial loads. Ball bearings shall be designed for shall be no less than 105 feet. a LB-10 life (50,000 hours). A heat sensor thermostat and overload shall 2. Pump be attached to the top end of the motor windings and shall stop the motor if the motor winding The pump shall have an integrally built in temperature reaches 200°F. The high tempera- grinder unit and submersible type motor. The ture shutoff will cause the pump to cease pump shall be suspended in the basin by two (2) operation, should a control failure cause the 1" guide rails and quick disconnect lift out pump to run in a dry wet well. The thermostat mounting assembly. Solids shall be fed in an up- shall reset automatically when the motor cools flow direction to the grinder mechanism with no to a safe operating temperature. obstructions below the grinder inlet. The grinder unit shall be capable of cutting 4. Power Cord solid material found in normal domestic sewage, The motor power cord shall be 14-5 SOW/SOW-A including reasonable amounts of foreign objects, and shall be fastened by means of a cord grip in such as wood, plastic, glass., rubber, sanitary the top of the pump. The top of the pump shall napkins, disposable diapers and panty hose into contain a waterproof junction box which will a fine slurry that will pass freely through the provide space to connect the power cord to the pump, service line and force main. motor leads. The motor leads shall seal between 3. Motor the motor housing and junction box by means of The pump motor shall be of the submersible a rubber compression fitting around each wire. type rated for 2 horsepower at 3450 RPM. Motor 5. Seal Chamber shall be single phase, 230 volt, 60 Hertz. Single phase motors shall be of the capacitor start- The motor shall be protected by two (2) rotary capacitor run type for high starting torque. shaft seals mounted in tandem with an oil filled The stator winding shall be the open type with chamber separating the seals. The seals shall Class A insulation rated for 105°C. maximum have carbon and ceramic seal faces diamond operating temperature. The winding housing lapped to a tolerance of one tight band. Metal will be filled with clean dielectric oil that will parts and springs for seals shall be stainless lubricate bearings, seals and transfer heat from steel. An electrical sensing probe shall be the windings to the outer shell. The motor stator mounted in the seal chamber to detect any water leakage past the lower seal. is to be pressed into the motor housing for optimum concentricity and alignment, and maximum heat transfer. The motor shall be capable of operating over full range of perform- ance curve without overloading motor and causing any objectional noise or vibration. 7 520/7-8 M"M 2HP Residential Grinder Pump Rail System Package Grinder Pump Technical Specifications 6. Pump Impeller holes so that screws can be used to push the The pump impeller shall be of the recessed shredding ring from the housing. Both the radial type to provide an open unobstructed passage cutter and shreddinq rinq shall be removable through the volute for the ground solids. The from the outside without dismantling pump. impeller shall be constructed of cast iron and Grinder assembly shall be of such construction shall have pump out vanes on the back side of that no clearance adjustments are required when the impeller to keep solids from lower seal and assembling. All grinding of solids shall be from reduce pressure at the seal faces. Impeller shall the action of the radial cutter against the be threaded onto the stainless steel shaft. shredding ring. The radial cutter and shredding ring shall be of#440 stainless steel hardened to 7. Grinder Assembly & Construction 58-60 Rockwell C. The grinder assembly shall consist of a 8. Pump & Motor Castings rotating radial cutter and a stationary shredding All iron castingshall be of high tensile cast ring, and shall be mounted directly below the iron and shall b properly cleaned, pre-treated volute passage. The rotating cutter shall be with chromic rinse, and ainted with a high threaded onto the stainless steel shaft and p 9 shall be locked with a screw and washer. The quality enamel paint. All pump components stationary shredding ring shall be pressed onto that are not cast iron or stainless steel shall be an iron holding flange for easy removal. The galvanized or painted with baked-on epoxy. flange shall be provided with tapped back-off All fasteners shall be#302 stainless steel. 8 520/7-9 M"M - - - - - 2HP Residential Grinder Pump Rail System Package Electrical 2HP 230V 10 Control Panel I _ 230V SI NGLE PHASE WITH 1NGLE GROUND 'NOTE:OVERLOAD IS AN : 20 AMP ON WINDING OVERLOAD. I I CIRCUIT BREAKER I L1 12 ( PUMP MOTOR 12 I23/ N ��-y BLACK I BLACK — q - I - �'- I 'OVERLOAD B BLACK MIWH �� WH � y 5 5 2 RED R RED IYEL RUN CAPACITOR I2 6 BLUE 1 WH/GPAY YEL START CAPACITOR WHITF SH-SIAHT RELAY OVERALL AND MOUNTING 6 WH/REp F A WHITE A-HIGH WATER ALARM DIMENSION$ HIGH WATER o—o—ll� 3AMP ALARM FUSE F-THERMAL FLASHER 0 OR WH/YEL TO SEAL LEAK R 7 ----- R-SEAL LEAK LIGHT 0 o w PROBEIN PUMP RED NEON 6 B O❑ z Y-RUN LIGHT(YELLOW) ORANGE HAND F-07 SLP-SEAL LEAK PROBE 0 I♦OI ° OFF WH/VIO MI WN IIIIII,IIIffLLL'y�dl]],JJJII(II' �p� MI-MOTOR CONTACTOR O ty-• AUTO VIOLET ORANGE 1 2 GRAvMI PUMP OFF ORANGE 0 VIOLET 3 q TERMINAL BLOCK WIRING R 1 2 9 4 g 6 T R W 8 ■ 2HP 230V 10 Control Panel PUMP ON Y g 5 S G G-GROUND BAR O o ¢ E o 14 2HP 230V 10 w m w C� Schematic Diagram Plug-in Connector � A waterproof male plug shall be supplied on the pum p p power and control cord and shall mate to a female socket mounted in the junction box. I- The plug and cord shall be of the proper size to handle the voltage and current requirements of the pump. The plug and receptacle shall be of the molded to cable and double face design. The °�°•.E, female half shall fit like a cork into the flexible shroud portion of the male. In addition, individual neoprene shoulders around contacts 44.-�,4 shall fit into recesses in female section. The cable shall be neoprene molded, one- piece design, and the connector shall have threaded coupling for positive tight connection and quick release. The mating connectors shall Plug-In Connector I have an indexing tab to insure proper alignment. 9 520/7-10 M"M ---- 2HP Residential Grinder Pump Rail System Package Electrical Technical Specifications Control Panel Junction Box A NEMA 3R control panel shall be furnished The junction box shall be constructed of with each pumping unit to be installed as shown structural plastic for corrosion resistance, stability on the plans. and mechanical strength. The enclosure shall be This panel shall include a two-pole, 20 amp, of adequate thickness and properly reinforced to main disconnect breaker, seal failure light, pump provide good mechanical strength. The junction hand-off auto switch, pump run light, start relay, box shall have a fully gasketed cover that is held run capacitor, start capacitor, terminal blocks, in place by four (4) captive stainless steel screws contactor, ground bar and all necessary wiring that can not be removed from the cover, with heads and brackets. totally encapsulated so that no metal parts are The control panel shall be housed in a fully- exposed. The screw heads shall be of adequate gasketed NEMA 313 enclosure with a hinged size so that they may easily be installed and door. The enclosure shall be a minimum of 16 removed without the use of special tools. The gauge for 12 x 12 x 6 or smaller, and 14 gauge for cover shall be fastened to the main body of the up to 20 x 20 x 6 enclosures. The enclosure shall junction box by means of totally corrosion- be gray enamel paint applied over treated steel resistant tether to prevent dropping the cover and shall have exterior mounting feet on the top into the basin during service. and bottom of the enclosure. Each enclosure An adequate number of sealing-type cord shall have a closing latch/locking hasp. grips shall be supplied for incoming pump and The back panel shall be painted 14 gauge steel switch cords. The cord grips shall be made of held in place by four (4) #10 screws mated to non-corrosive material, such as PVC or nylon, four (4) threaded standoffs which are welded to and shall make an effective seal around the wire the back of the enclosure. jacket. The cord grip shall also seal to the The control enclosure shall be fitted with a red junction box wall with an "0" ring, gasket, or lexan (polycarbonate) alarm light. The light shall other effective means. be approximately 3" high by 31/2" diameter. The The junction box shall have a PVC solvent globe shall'be mounted on top of the enclosure weld socket type conduit hub mounted in the with a neoprene gasket. The lens cannot be bottom of the enclosure. The hub shall be of a removed from the exterior of the enclosure. The corrosion resistant material and shall be of lens may be removed by entering the interior of adequate size to accommodate the number of the enclosure and removing four (4) #8 screws. wires required to operate the pump. The bulb shall be 40 watt, high-intensity, A method for sealing the incoming wires shall medium-base type. The bulb shall be easily be supplied so that condensation from the con- replaced by removing a thumb screw from the duit or ground water will not enter the enclosure. support bracket on the interior of the panel. The sealing method shall be offered as a kit con- The alarm shall have bright glow and flash taining all necessary mixing, measuring, stirring during high water conditions. The alarm light and potting material required for an effective in- will go out when the water level drops. field seal. The interior of the enclosure shall be All internal wiring shall be neat and color- of adequate size to accommodate the wires and coded (each wire a different color or strip, connections required to operate the pump. except for ground). All incoming wires shall The wires running between the control panel terminate into a box clamp type terminal block, and the junction box shall be color-coded and except incoming power. fastened to the pump and switch controls by A schematic diagram (showing wire color means of adequately sized and insulated twist where practical) shall be permanently fastened lock or crimp connectors. to the inside of the enclosure. The junction box shall be designed to NEMA 6 standards for occasional submergence. 10 520/7-11 M"M 2HP Residential Grinder Pump Rail System Package Electrical Optional Fiberglass Enclosures Fiberglass Enclosures The control panel enclosures shall be molded of glass reinforced polyester resins which are chemically resistant to corrosive atmospheres. � The resin system shall be pigmented to impart a gray color to the enclosures and be resistant to ultra-violet light. The resin system also shall include a flame a retardant to obtain a flammability rating which meets UL 94V-0. Heat distortion temperature shall be 350°F. The enclosure shall be of one-piece, weather- �.. proof construction with smooth, rounded a corners and shall be constructed to have a smooth exterior and interior. The enclosure shall be fitted with a closed cell neoprene gasketed cover. The enclosure shall be provided with back panel mounting provisions. The cover shall be hinged with a stainless steel piano hinge. The cover shall be lockable by means of two (2) high quality combination - stainless steel latches and padlock hasps. The enclosure will be provided with external mounting feet on the top and bottom of the 15 Z 14 e enclosure. These mounting feet shall be of fiberglass and molded as an integral part of the enclosure. L 6 13 16 OVERALL AND MOUNTING DIMENSIONS FOR FIBERGLASS JUNCTION ENCLOSURE LA x I x 58 ((INSIDE DIMENSIONS 11 %526/7-12 M"M 2HP Residential Grinder Pump Rail System Package Prices Subject to change without notice WGL20-21 Series Grinder Pump Basin Packages All Parts Factory Mounted Simplex 24" Diameter Basin Packaged Basin Units with Lift-Out Rail System with Control Panel Mounted in a NEMA 3R Metal Enclosure, Basin and Cover Designed for Off-Set Mounting of Control Box BASIN CATALOG ENGINEERING SHIPPING LIST DEPTH NUMBER NUMBER WT.LBS. PRICE 5 Ft. BP12RO-2460P 23905A200 325 $2897.00 6 Ft. BP12RO-2472P 23905A201 345 $2953.00 7 Ft. BP12RO-2484P 23905A202 365 $3080.00 8 Ft. BP12RO-2496P 23905A203 385 $3236.00 Complete package consisting of all items shown in this brochure can be obtained by placing an order for one of the catalog numbers above.. All Parts Factory Mounted Simplex 24" Diameter Basin Packaged Basin Units with Lift-Out Rail System with Control Panel Mounted in a NEMA 4X Fiberglass Enclosure, Basin and Cover Designed for Off-Set Mounting of Control Box BASIN CATALOG ENGINEERING SHIPPING LIST DEPTH NUMBER NUMBER WT.LBS. PRICE 5 Ft. BP12RO-246OPFG 23905A204 320 $2957.00 6 Ft. BP12RO-2472PFG 23905A205 340 $3013.00 7 Ft. BP12RO-2484PFG 23905A206 360 $3140.00 8 Ft. tR12R0-2496PFCi' 23905A207 380 $3296.00 Complete package consisting of all items shown in this brochure can be obtained by placing an order for one of the catalog numbers above. C rJ �- M"M F.E.Myers,A Pentair Company 1101 Electric Ave.,Ashland,OH 44805-1923 K3170 419/289-1144, FAX:419/289-6658,TLX:98-7443 12/87 Printed in U.S.A. Structural Polypropylene Cover iw Il�J b � 1 r, IIII,, m"I y y Guide Rails Y.,Imo----... GRADE... r!f \ b% Control Panel and Visual High Water Alarm Structural Lifting Chain Plastic Junction Box PVC Ball Type Shut Off Valve and Handle ° i PVC Discharge Pipe High Water Alarm Mercury I Level Control inlet Hub Quick Disconnect (Field Mounted) i Flange ON and OFF t I \ Mercury Level Controls r i 2 Grinder i Check Valve Pump � _ Anti-Flotation Hold Down Flange 24"Diameter by 60" / Fiberglass Basin .• ° Concrete MYMI Typical Simplex 2 HP Residential Grinder Pump Rail System Package for Pressure Sewer System Applications 522/29 1/2/89 M"rS LIST PRICES Subject to change without notice "TURNKEY" SIMPLEX 2 HP 230V 10 60- CONTROL PANEL 230V SINGLE PHASE WITH 115V TO GROUND 'NOTE: DING OVERLOAD A i I I pp AMp ON WINDING OVERLOAD. i I I CIRCUIT BRA I L1 L2 I, PUMPMOTOR 2 y N � MI — - I 'OVERLOAD BLACK B �( �IWHWH a Q Imo—12 4...— 5 SR 2 RED R _ 10—.� 6 BLUE RED vEl RUN CAPACITOR WH/GRAY YEL I START CAPACITOR WHITE OVERALL AND MOUNTING ,. � F SR-START RELAY DIMENSIONS I'1 WH/REDf-]y_O WHITE A-HIGH WATER ALARM 3 AM!' III(iII WAI LII ,1 FUSE ALARM �� F-THERMAL FLASHER 0 OR WH/YEL T_O SEAL_LEAK f1 PRORE IN PUMP R-SEAL LEAK LIGHT RED NEON 0 0 OO O Y-RUN LIGHT(YELLOW) ORANGE HAND Y SLP-SEAL LEAK PROBE 0 0 OFF WH/VIO MI WH MI-MOTOR CONTACTOR AUTO VIOLET ORANGE 1 2 GggYMI PUMPOFF -- ORANGE 0 3 4 VIOLET TERMINAL BLOCK WIRING 2HP 230V 10 Control Panel 2 D 4 5 6 III ]R W R PUMPON S i F g e I a _ G G-GROUNDBAP G G ¢ f 3 O 2HP 230V 10 a /-- - Schematic Diagram 3 ¢ u 3 w — o ,n / scx,ws rc.on.o •,• E. Plug-in Connector sr'° A waterproof male plug shall be supplied on the pump power and control cord and shall mate _ to a female socket mounted in the junction box. The plug and cord shall be of the proper size to handle the voltage and current requirements of the pump. The plug and receptacle shall be of the molded to cable and double face design. The female half shall fit like a cork into the flexible shroud portion of the male. In addition, individual neoprene shoulders around contacts shall fit into recesses in female section. The cable shall be neoprene molded, one- -_ i piece design, and the connector shall have threaded coupling for positive tight connection and quick release. The mating connectors shall Plug-In Connector i have an indexing tab to insure proper alignment. F.E.Myers reserves the right to substitute and/or improve product materials whenever necessary. F.E.Myers,A Pentair Company 1101 Myers Parkway,Ashland,Ohio 44805-1923 419/289-1144 FAX 419/289-6658 Telex 98-7443 522/30 1/2/89 y Myem LIST PRICES Subject to change without notice -- - ---------- inn imn-mbil-tall OPTIONAL FIBERGLASS ENCLOSURES Fiberglass Enclosures The control panel enclosures shall be molded of glass reinforced polyester resins which are chemically resistant to corrosive atmospheres. � The resin system shall be pigmented to impart a gray color to the enclosures and be resistant to ultra-violet light. The resin system also shall include a flame ° retardant to obtain a flammability rating which meets UL 94V-0. Heat distortion temperature shall be 350°F. The enclosure shall be of one-piece, weather- �.. proof construction with smooth, rounded ° corners and shall be constructed to have a smooth exterior and interior. The enclosure shall be fitted with a closed cell neoprene gasketed cover. The enclosure shall be provided with back panel mounting provisions. The cover shall be hinged with a stainless steel piano hinge. The cover shall be lockable by means of two (2) high quality combination stainless steel latches and padlock hasps. The enclosure will be provided with external mounting feet on the top and bottom of the 15 2 14 e enclosure. These mounting feet shall be of fiberglass and molded as an integral part of the enclosure. L13 16 OVERALL AND MOUNTING DIMENSIONS FOR FIBERGLASS JUNCTION ENCLOSURE 14 x 12 x 5Z (INSIDE DIMENSIONS F.E.Myers reserves the right to substitute and/or improve product materials whenever necessary. F.E.Myers,A Pentair Company 1101 Myers Parkway,Ashland,Ohio 44805-1923 419/289-1144 FAX 419/289-6658 Telex 98-7443 • a 17 12 4 15 it 0., s.p•.. G. • e e o° �P o� 0 o a-7 ° o� ,yBELOW MAX U a ° °goon osP�0 FROST DEPTH 14 3 10 g 2 �\ a 5 0 4 � 4 0' 16 I 1 16 1 TERMINAL FLUSHING INLINE FLUSHING CONNECTION CONNECTION 1 FIG. 9 FLUSHING CONNECTIONS- L LOW PRESSURE SEWER SYSTEM (LPSS) IL METER BOX or concrete, steel or aluminum MAIN corrugated pipe, etc. 2. GATE VALVE-fully ported,size of LPSS main. 12. COVER-concrete,steel, etc. weatherproof 3. VALVE BOX-length as required. vandalproof._ 4.CONCRETE COLLAR T 137CiR-;V'EL-BEDDING - for box support and surface water leaching. 5. TEE or SADDLE-size of LPSS main. 14. CONCRETE PAD - if installed in traffic area, 6. REDUCER —2"x size of LPSS main. concrete should be used in place of gravel bedding. 7. 2"RISER 15.INSULATION-may be required in severe climates. 8. THREADED ADAPTER 9. 2"GATE VALVE-wrench operated. 16. CONCRETE THRUST BLOCK 10. ELBOW-450 17. FINISHED GRADE 23 CAP. _.�` . . . 4M E T E R :'BOX . BALL OR GATE VA LV E BALL OR GATE VALVE FIGURE 4- 1 IN LINE CLEANOUT METER BOX CAP BALL OR GATE VALVE FIGURE 4 -2 TERMINAL CLEANOUT 4-3