Loading...
HomeMy WebLinkAboutDrain Layers Permit 53 Carson Way ' •.x _ , < ' t: yv < . a TOWN OF SOUTH WINDSOR DEPARTMENT OF PUBLIC WORKS BUREAU OF POLLUTION CONTROL DRAIN LAYER'S PERMIT 5985 I I 91:L Pursuant to written application, permission is hereby granted to the �`` Licensed Drain����L��yer named re n to perform the work indicated below t Ls+7��Ci4rS oy't�iyRG .T, 4V 1; premises ,owped by �' S S SZ IQ l.'�,� r, krf Le d whose address is Jh s^ /^ aid_ to Lay. House Drain, Repaillvtiouse Drain, Lay Main, Other for t occupancy or use, with Family Units," Vith acres.,. . . Type of Sewage to be connected under this permit : SANITARY SEWAGE INDUSTRIAL WASTES ( . "'OR Connection will be made with SnR St�4JPr !�/ate Show sketch of proposed workor furnish 'two (2) copies of separate drawings. SPECIAL CONDITIONS. OSHA REQUIREMENTS MUST BE FOLLOWED Desired Starting Date Estimated Time for Completion / Permit to be issued to �Q�1r/1 J9G'6CjE'S the holder of Drain Layer's License No. WVg30 Permit will expire thirty (30) days after date of issuance. The undersigned Drain Layer hereby agrees to all the terms and conditions set . forth in the permit and the reverse side thereof. Applicant has' r'eceived' Town. Permit No. and/or CHD Permit No.. SignedY A ce6- Ale d D in Layer The above named Drain Layer has a valid license issued by the State of Connecticut and has filed a satisfactory and and insurance policy in the name of the Town of South Windsor: J��i 1.l� ngie in Dept. Date Permit Fee Paid $'` Z,f�O� Chec Number Connection Charge Receipt No. _ 33. Dated `711z/9 S Issued by INSPECTION Date work started 7 — 9 93; Date completed 7- Sufficient notification rece3 ve es No Special Conditions Of APPROVED• Inspector Date TOWN OF SOUM W33WOR SANIM Y SERER INSPECTION CHECKLIST FUNCTION F. NO YES N/A DATE INSPECTED 1. Is Permit On Job Site `�� <� 2. Police Notified 3 . Safety Items In Place a. Shoring, Trench Box, Ladder b. Hard Hats C . Pumps 4. Proper Material a. Pipe v b. Pipe Bedding ✓ c. Backfill d. Warning Tape ✓ e. Pipe Cap or Plug ✓ f . Cleanouts g. Fittings - h. Manhole !/ i. Cover & Frame ✓ 5 . Existing Lateral Cap Removed in Presence of Inspector 6 . Lateral probed and found / to be clear 7 . Pavement Cut Properly ✓ 8 . Trench & Bedding OK 9 . Joints Properly Done 10 . Backfilling (12" Lifts ) ✓ & Compaction 11. Manhole Inverts Built 12. Subbase Material Placed 1/ 13 . Base Material Placed 14 . Blacktop (Temp) w/Proper Grades & Slopes 15 . Pressure Test 16: Mandrel Test 17 . Installation agrees with plan 18. As-Built plans recorded _